1
|
Hu Y, Liu X, Zhang W, Chen J, Chen X, Tan S. Inulin Can Improve Red Blood Cell Cryopreservation by Promoting Vitrification, Stabilizing Cell Membranes, and Inhibiting Ice Recrystallization. ACS Biomater Sci Eng 2024; 10:851-862. [PMID: 38176101 DOI: 10.1021/acsbiomaterials.3c01463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2024]
Abstract
In transfusion medicine, the cryopreservation of red blood cells (RBCs) is of major importance. The organic solvent glycerol (Gly) is considered the current gold-standard cryoprotectant (CPA) for RBC cryopreservation, but the deglycerolization procedure is complex and time-consuming, resulting in severe hemolysis. Therefore, it remains a research hotspot to find biocompatible and effective novel CPAs. Herein, the natural and biocompatible inulin, a polysaccharide, was first employed as a CPA for RBC cryopreservation. The presence of inulin could improve the thawed RBC recovery from 11.83 ± 1.40 to 81.86 ± 0.37%. It was found that inulin could promote vitrification because of its relatively high viscosity and glass transition temperature (Tg'), thus reducing the damage during cryopreservation. Inulin possessed membrane stability, which also had beneficial effects on RBC recovery. Moreover, inulin could inhibit the mechanical damage induced by ice recrystallization during thawing. After cryopreservation, the RBC properties were maintained normally. Mathematical modeling analysis was adopted to compare the performance of inulin, Gly, and hydroxyethyl starch (HES) in cryopreservation, and inulin presented the best efficiency. This work provides a promising CPA for RBC cryopreservation and may be beneficial for transfusion therapy in the clinic.
Collapse
Affiliation(s)
- Yuying Hu
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, Hunan 410013, China
| | - Xiangjian Liu
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, Hunan 410013, China
| | - Wenqian Zhang
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, Hunan 410013, China
| | - Jiangming Chen
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, Hunan 410013, China
| | - Xiaoxiao Chen
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, Hunan 410013, China
| | - Songwen Tan
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, Hunan 410013, China
| |
Collapse
|
2
|
Stilgoe AB, Kashchuk AV, Balanant MA, Santangelo D, Nieminen TA, Sauret E, Flower R, Rubinsztein-Dunlop H. Tired and stressed: direct holographic quasi-static stretching of aging echinocytes and discocytes in plasma using optical tweezers [Invited]. BIOMEDICAL OPTICS EXPRESS 2024; 15:656-671. [PMID: 38404345 PMCID: PMC10890887 DOI: 10.1364/boe.504779] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/23/2023] [Accepted: 11/26/2023] [Indexed: 02/27/2024]
Abstract
Red blood cells (RBCs) undergo a progressive morphological transformation from smooth biconcave discocytes into rounder echinocytes with spicules on their surface during cold storage. The echinocytic morphology impacts RBCs' ability to flow through narrow sections of the circulation and therefore transfusion of RBC units with a high echinocytic content are thought to have a reduced efficiency. We use an optical tweezers-based technique where we directly trap and measure linear stiffness of RBCs under stress without the use of attached spherical probe particles or microfluidic flow to induce shear. We study RBC deformability with over 50 days of storage performing multiple stretches in blood plasma (serum with cold agglutinins removed to eliminate clotting). In particular, we find that discocytes and echinocytes do not show significant changes in linear stiffness in the small strain limit (∼ 20 % change in length) up to day 30 of the storage period, but do find differences between repeated stretches. By day 50 the linear stiffness of discocytes had increased to approximately that measured for echinocytes throughout the entire period of measurements. These changes in stiffness corresponded to recorded morphological changes in the discocytes as they underwent storage lesion. We believe our holographic trapping and direct measurement technique has applications to directly control and quantify forces that stretch other types of cells without the use of attached probes.
Collapse
Affiliation(s)
- Alexander B. Stilgoe
- School of Mathematics and Physics, The University of Queensland, St. Lucia, Brisbane, QLD, 4072, Australia
- Australian Research Council Centre of Excellence for Engineered Quantum Systems, School of Mathematics and Physics, University of Queensland, St. Lucia, QLD, 4072, Australia
| | - Anatolii V. Kashchuk
- School of Mathematics and Physics, The University of Queensland, St. Lucia, Brisbane, QLD, 4072, Australia
- Currently with LENS, European Laboratory for Non-Linear Spectroscopy, Via Nello Carrara 1, Sesto Fiorentino, 50019, Italy, and Department of Physics and Astronomy, University of Florence, Via Sansone 1, Sesto Fiorentino, 50019, Italy
| | - Marie-Anne Balanant
- Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, 4000, Australia
- Australian Red Cross Lifeblood, Brisbane, QLD, 4059, Australia
| | - Deborah Santangelo
- Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, 4000, Australia
- Australian Red Cross Lifeblood, Brisbane, QLD, 4059, Australia
| | - Timo A. Nieminen
- School of Mathematics and Physics, The University of Queensland, St. Lucia, Brisbane, QLD, 4072, Australia
| | - Emilie Sauret
- Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, 4000, Australia
| | - Robert Flower
- Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, 4000, Australia
- Australian Red Cross Lifeblood, Brisbane, QLD, 4059, Australia
| | - Halina Rubinsztein-Dunlop
- School of Mathematics and Physics, The University of Queensland, St. Lucia, Brisbane, QLD, 4072, Australia
- Australian Research Council Centre of Excellence for Engineered Quantum Systems, School of Mathematics and Physics, University of Queensland, St. Lucia, QLD, 4072, Australia
| |
Collapse
|
3
|
Kang YJ. Biomechanical Investigation of Red Cell Sedimentation Using Blood Shear Stress and Blood Flow Image in a Capillary Chip. MICROMACHINES 2023; 14:1594. [PMID: 37630130 PMCID: PMC10456426 DOI: 10.3390/mi14081594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 08/01/2023] [Accepted: 08/11/2023] [Indexed: 08/27/2023]
Abstract
Blood image intensity has been used to detect erythrocyte sedimentation rate (ESR). However, it does not give information on the biophysical properties of blood samples under continuous ESR. In this study, to quantify mechanical variations of blood under continuous ESR, blood shear stress and blood image intensity were obtained by analyzing blood flows in the capillary channel. A blood sample is loaded into a driving syringe to demonstrate the proposed method. The blood flow rate is set in a periodic on-off pattern. A blood sample is then supplied into a capillary chip, and microscopic blood images are captured at specific intervals. Blood shear stress is quantified from the interface of the bloodstream in the coflowing channel. τ0 is defined as the maximum shear stress obtained at the first period. Simultaneously, ESRτ is then obtained by analyzing temporal variations of blood shear stress for every on period. AII is evaluated by analyzing the temporal variation of blood image intensity for every off period. According to the experimental results, a shorter period of T = 4 min and no air cavity contributes to the high sensitivity of the two indices (ESRτ and AII). The τ0 exhibits substantial differences with respect to hematocrits (i.e., 30-50%) as well as diluents. The ESRτ and AII showed a reciprocal relationship with each other. Three suggested properties represented substantial differences for suspended blood samples (i.e., hardened red blood cells, different concentrations of dextran solution, and fibrinogen). In conclusion, the present method can detect variations in blood samples under continuous ESR effectively.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
4
|
Hu Y, Liu X, Ekpo MD, Chen J, Chen X, Zhang W, Zhao R, Xie J, He Y, Tan S. Dimethylglycine Can Enhance the Cryopreservation of Red Blood Cells by Reducing Ice Formation and Oxidative Damage. Int J Mol Sci 2023; 24:ijms24076696. [PMID: 37047668 PMCID: PMC10095525 DOI: 10.3390/ijms24076696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/15/2023] [Accepted: 03/31/2023] [Indexed: 04/14/2023] Open
Abstract
The cryopreservation of red blood cells (RBCs) holds great potential for ensuring timely blood transfusions and maintaining an adequate RBC inventory. The conventional cryoprotectants (CPAs) have a lot of limitations, and there is an obvious need for novel, efficient, and biocompatible CPAs. Here, it is shown for the first time that the addition of dimethylglycine (DMG) improved the thawed RBC recovery from 11.55 ± 1.40% to 72.15 ± 1.22%. We found that DMG could reduce the mechanical damage by inhibiting ice formation and recrystallization during cryopreservation. DMG can also scavenge reactive oxygen species (ROS) and maintain endogenous antioxidant enzyme activities to decrease oxidative damage during cryopreservation. Furthermore, the properties of thawed RBCs were found to be similar to the fresh RBCs in the control. Finally, the technique for order performance by similarity to ideal solution (TOPSIS) was used to compare the performance of glycerol (Gly), hydroxyethyl starch (HES), and DMG in cryopreservation, and DMG exhibited the best efficiency. This work confirms the use of DMG as a novel CPA for cryopreservation of RBCs and may promote clinical transfusion therapy.
Collapse
Affiliation(s)
- Yuying Hu
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Xiangjian Liu
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Marlene Davis Ekpo
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Jiangming Chen
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Xiaoxiao Chen
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Wenqian Zhang
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Rui Zhao
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Jingxian Xie
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| | - Yongju He
- School of Materials Science and Engineering, Central South University, Changsha 410013, China
| | - Songwen Tan
- Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China
| |
Collapse
|
5
|
Laha S, Kar S, Chakraborty S. Cellular aggregation dictates universal spreading behaviour of a whole-blood drop on a paper strip. J Colloid Interface Sci 2023; 640:309-319. [PMID: 36867927 DOI: 10.1016/j.jcis.2023.02.048] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2022] [Revised: 01/26/2023] [Accepted: 02/11/2023] [Indexed: 02/21/2023]
Abstract
HYPOTHESIS The complex spreading dynamics of blood on paper matrix is likely to be quantitatively altered with variations in the fractional occupancy of red blood cells in the whole blood (haematocrit). Here, we presented an apparently surprising observation that a finite volume blood drop undergoes a universal time-dependent spreading on a filter paper strip that is virtually invariant with its hematocrit level within physiologically healthy regime, though distinctively distinguishable from the spreading laws of blood plasma and water. EXPERIMENTS Our hypothesis was ascertained by performing controlled wicking experiments on filter papers of different grades. Spreading of human blood samples of different haematocrit levels ranging between 15% and 51% and the plasma separated from therein were traced by combined high-speed imaging and microscopy. These experiments were complemented with a semi-analytical theory to decipher the key physics of interest. RESULTS Our results unveiled the exclusive influence of the obstructing cellular aggregates in the randomly distributed hierarchically structured porous pathways and deciphered the role of the networked structures of the various plasma proteins that induced hindered diffusion. The resulting universal signatures of spontaneous dynamic spreading, delving centrally on the fractional reduction in the interlaced porous passages, provide novel design basis for paper-microfluidic kits in medical diagnostics and beyond.
Collapse
Affiliation(s)
- Sampad Laha
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur 721302, India
| | - Shantimoy Kar
- Advanced Technology Development Centre, Indian Institute of Technology, Kharagpur 721302, India; Department of Medical Devices, National Institute of Pharmaceutical Education and Research (NIPER) Hyderabad, Telangana 500037, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur 721302, India; Advanced Technology Development Centre, Indian Institute of Technology, Kharagpur 721302, India.
| |
Collapse
|
6
|
Grigorev GV, Lebedev AV, Wang X, Qian X, Maksimov GV, Lin L. Advances in Microfluidics for Single Red Blood Cell Analysis. BIOSENSORS 2023; 13:117. [PMID: 36671952 PMCID: PMC9856164 DOI: 10.3390/bios13010117] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/04/2022] [Accepted: 12/23/2022] [Indexed: 05/24/2023]
Abstract
The utilizations of microfluidic chips for single RBC (red blood cell) studies have attracted great interests in recent years to filter, trap, analyze, and release single erythrocytes for various applications. Researchers in this field have highlighted the vast potential in developing micro devices for industrial and academia usages, including lab-on-a-chip and organ-on-a-chip systems. This article critically reviews the current state-of-the-art and recent advances of microfluidics for single RBC analyses, including integrated sensors and microfluidic platforms for microscopic/tomographic/spectroscopic single RBC analyses, trapping arrays (including bifurcating channels), dielectrophoretic and agglutination/aggregation studies, as well as clinical implications covering cancer, sepsis, prenatal, and Sickle Cell diseases. Microfluidics based RBC microarrays, sorting/counting and trapping techniques (including acoustic, dielectrophoretic, hydrodynamic, magnetic, and optical techniques) are also reviewed. Lastly, organs on chips, multi-organ chips, and drug discovery involving single RBC are described. The limitations and drawbacks of each technology are addressed and future prospects are discussed.
Collapse
Affiliation(s)
- Georgii V. Grigorev
- Data Science and Information Technology Research Center, Tsinghua Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
- School of Information Technology, Cherepovets State University, 162600 Cherepovets, Russia
| | - Alexander V. Lebedev
- Machine Building Department, Bauman Moscow State University, 105005 Moscow, Russia
| | - Xiaohao Wang
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Xiang Qian
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - George V. Maksimov
- Faculty of Biology, Lomonosov Moscow State University, 119991 Moscow, Russia
- Physical metallurgy Department, Federal State Autonomous Educational Institution of Higher Education National Research Technological University “MISiS”, 119049 Moscow, Russia
| | - Liwei Lin
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
| |
Collapse
|
7
|
Kang YJ. Biosensing of Haemorheological Properties Using Microblood Flow Manipulation and Quantification. SENSORS (BASEL, SWITZERLAND) 2022; 23:408. [PMID: 36617006 PMCID: PMC9823650 DOI: 10.3390/s23010408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 06/17/2023]
Abstract
The biomechanical properties of blood have been used to detect haematological diseases and disorders. The simultaneous measurement of multiple haemorheological properties has been considered an important aspect for separating the individual contributions of red blood cells (RBCs) and plasma. In this study, three haemorheological properties (viscosity, time constant, and RBC aggregation) were obtained by analysing blood flow, which was set to a square-wave profile (steady and transient flow). Based on a simplified differential equation derived using a discrete circuit model, the time constant for viscoelasticity was obtained by solving the governing equation rather than using the curve-fitting technique. The time constant (λ) varies linearly with respect to the interface in the coflowing channel (β). Two parameters (i.e., average value: <λ>, linear slope: dλdβ) were newly suggested to effectively represent linearly varying time constant. <λ> exhibited more consistent results than dλdβ. To detect variations in the haematocrit in blood, we observed that the blood viscosity (i.e., steady flow) is better than the time constant (i.e., transient flow). The blood viscosity and time constant exhibited significant differences for the hardened RBCs. The present method was then successfully employed to detect continuously varying haematocrit resulting from RBC sedimentation in a driving syringe. The present method can consistently detect variations in blood in terms of the three haemorheological properties.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
8
|
Kim H, Zhbanov A, Yang S. Microfluidic Systems for Blood and Blood Cell Characterization. BIOSENSORS 2022; 13:13. [PMID: 36671848 PMCID: PMC9856090 DOI: 10.3390/bios13010013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
A laboratory blood test is vital for assessing a patient's health and disease status. Advances in microfluidic technology have opened the door for on-chip blood analysis. Currently, microfluidic devices can reproduce myriad routine laboratory blood tests. Considerable progress has been made in microfluidic cytometry, blood cell separation, and characterization. Along with the usual clinical parameters, microfluidics makes it possible to determine the physical properties of blood and blood cells. We review recent advances in microfluidic systems for measuring the physical properties and biophysical characteristics of blood and blood cells. Added emphasis is placed on multifunctional platforms that combine several microfluidic technologies for effective cell characterization. The combination of hydrodynamic, optical, electromagnetic, and/or acoustic methods in a microfluidic device facilitates the precise determination of various physical properties of blood and blood cells. We analyzed the physical quantities that are measured by microfluidic devices and the parameters that are determined through these measurements. We discuss unexplored problems and present our perspectives on the long-term challenges and trends associated with the application of microfluidics in clinical laboratories. We expect the characterization of the physical properties of blood and blood cells in a microfluidic environment to be considered a standard blood test in the future.
Collapse
Affiliation(s)
- Hojin Kim
- Department of Mechatronics Engineering, Dongseo University, Busan 47011, Republic of Korea
| | - Alexander Zhbanov
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
| | - Sung Yang
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
- Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
| |
Collapse
|
9
|
Kang YJ, Serhrouchni S, Makhro A, Bogdanova A, Lee SS. Simple Assessment of Red Blood Cell Deformability Using Blood Pressure in Capillary Channels for Effective Detection of Subpopulations in Red Blood Cells. ACS OMEGA 2022; 7:38576-38588. [PMID: 36340168 PMCID: PMC9631408 DOI: 10.1021/acsomega.2c04027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 10/07/2022] [Indexed: 06/16/2023]
Abstract
Assessment of red blood cell (RBC) deformability as a biomarker requires expensive equipment to induce and monitor deformation. In this study, we present a simple method for quantifying RBC deformability. We designed a microfluidic channel consisting of a micropillar channel and a coflowing channel connected in series. When blood (loading volume = 100 μL) was injected continuously into the device under constant pressure (1 bar), we monitored the boundary position of the blood and the reference flow in the coflowing channel. A decrease in the deformability of RBCs results in a growing pressure drop in the micropillar channel, which is mirrored by a decrease in blood pressure in the coflowing channel. Analysis of this temporal variation in blood pressure allowed us to define the clogging index (CI) as a new marker of RBC deformability. As a result of the analytical study and numerical simulation, we have demonstrated that the coflowing channel may serve as a pressure sensor that allows the measurement of blood pressure with accuracy. We have shown experimentally that a higher hematocrit level (i.e., more than 40%) does not have a substantial influence on CI. The CI tended to increase to a higher degree in glutaraldehyde-treated hardened RBCs. Furthermore, we were able to resolve the difference in deformability of RBCs between two different RBC density subfractions in human blood. In summary, our approach using CI provides reliable information on the deformability of RBCs, which is comparable to the readouts obtained by ektacytometry. We believe that our microfluidic device would be a useful tool for evaluating the deformability of RBCs, which does not require expensive instruments (e.g., high-speed camera) or time-consuming micro-PIV analysis.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department
of Mechanical Engineering, Chosun University, Gwangju501-759, Republic of Korea
| | - Sami Serhrouchni
- Institute
of Veterinary Physiology, University of
Zürich, Zürich8057, Switzerland
| | - Asya Makhro
- Institute
of Veterinary Physiology, University of
Zürich, Zürich8057, Switzerland
| | - Anna Bogdanova
- Institute
of Veterinary Physiology, University of
Zürich, Zürich8057, Switzerland
- Center
for Clinical Studies (ZKS), Vetsuisse Faculty, University of Zürich, Zürich8006, Switzerland
| | - Sung Sik Lee
- Scientific
Center for Optical and Electron Microscopy, ETH Zürich, Zürich8093, Switzerland
- Department
of Biology, Institute of Biochemistry, ETH
Zürich, Zürich8093, Switzerland
| |
Collapse
|
10
|
Kang YJ. Red Blood Cell Sedimentation Index Using Shear Stress of Blood Flow in Microfluidic Channel. BIOSENSORS 2022; 12:bios12070547. [PMID: 35884350 PMCID: PMC9312500 DOI: 10.3390/bios12070547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 07/19/2022] [Accepted: 07/19/2022] [Indexed: 11/30/2022]
Abstract
Red blood cell sedimentation has been used as a promising indicator of hematological diseases and disorders. However, to address several issues (i.e., syringe installation direction, blood on-off flow control, image-based quantification, and hemodilution) raised by the previous methods, it is necessary to devise a new method for the effective quantification of red blood cell sedimentation under a constant blood flow. In this study, the shear stress of a blood flow is estimated by analyzing an interface in a co-flowing channel to quantify the red blood cell sedimentation in blood syringes filled with blood (hematocrit = 50%). A red blood cell sedimentation index is newly suggested by analyzing the temporal variations in the shear stress. According to the experimental investigation, the sedimentation index tends to decrease at a higher flow rate. A higher level of hematocrit has a negative influence on the sedimentation index. As a performance demonstration of the present method, the red blood cell sedimentation processes of various test bloods were quantitatively compared in terms of the shear stress, image intensity, and sedimentation velocity. It was found that the proposed index provided a more than 10-fold increase in sensitivity over the previous method (i.e., image intensity). Additionally, it provided more consistent results than another conventional sedimentation method (sedimentation velocity). In conclusion, the present index can be effectively adopted to monitor the red blood cell sedimentation in a 10-min blood delivery.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
| |
Collapse
|
11
|
Kang YJ. Contributions of Red Blood Cell Sedimentation in a Driving Syringe to Blood Flow in Capillary Channels. MICROMACHINES 2022; 13:mi13060909. [PMID: 35744523 PMCID: PMC9229591 DOI: 10.3390/mi13060909] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 06/02/2022] [Accepted: 06/06/2022] [Indexed: 12/18/2022]
Abstract
The erythrocyte sedimentation rate (ESR), which has been commonly used to detect physiological and pathological diseases in clinical settings, has been quantified using an interface in a vertical tube. However, previous methods do not provide biophysical information on blood during the ESR test. Therefore, it is necessary to quantify the individual contributions in terms of viscosity and pressure. In this study, to quantify RBC sedimentation, the image intensity (Ib) and interface (β) were obtained by analyzing the blood flow in the microfluidic channels. Based on threshold image intensity, the corresponding interfaces of RBCs (Ib > 0.15) and diluent (Ib < 0.15) were employed to obtain the viscosities (µb, µ0) and junction pressures (Pb, P0). Two coefficients (CH1, CH2) obtained from the empirical formulas (µb = µ0 [1 + CH1], Pb = P0 [1 + CH2]) were calculated to quantify RBC sedimentation. The present method was then adopted to detect differences in RBC sedimentation for various suspended blood samples (healthy RBCs suspended in dextran solutions or plasma). Based on the experimental results, four parameters (µ0, P0, CH1, and CH2) are considered to be effective for quantifying the contributions of the hematocrit and diluent. Two coefficients exhibited more consistent trends than the conventional ESR method. In conclusion, the proposed method can effectively detect RBC sedimentation.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
| |
Collapse
|
12
|
Kang YJ. Sequential quantification of blood and diluent using red cell sedimentation-based separation and pressure-induced work in a microfluidic channel. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1194-1207. [PMID: 35234222 DOI: 10.1039/d1ay02178h] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The erythrocyte sedimentation method has been widely used to detect inflammatory diseases. However, this conventional method still has several drawbacks, such as a large blood volume (∼1 mL) and difficulty in continuous monitoring. Most importantly, image-based methods cannot quantify RBC-rich blood (blood) and RBC-free blood (diluent) simultaneously. In this study, instead of visualizing interface movement in the blood syringe, a simple method is proposed to quantify blood and diluent in microfluidic channels sequentially. The hematocrit was set to 25% to enhance RBC sedimentation and form two layers (blood and diluent) in the blood syringe. An air cavity (∼300 μL) inside the blood syringe was secured to completely remove dead volumes (∼200 μL) in fluidic paths (syringe needle and tubing). Thus, a small blood volume (Vb = 50 μL) suctioned into the blood syringe is sufficient for supplying blood and diluent in the blood channel sequentially. The relative ratio of blood resident time (RBC-to-diluent separation) was quantified using λb, which was obtained by quantifying the image intensity of blood flow. After the junction pressure (Pj) and blood volume (V) were obtained by analyzing the interface in the coflowing channel, the averaged work (Wp [Pa mm3]) was calculated and adopted to detect blood and diluent, respectively. The proposed method was then applied with various concentrations of dextran solution to detect aggregation-elevated blood. The Wp of blood and diluent exhibited substantial differences with respect to dextran solutions ranging from Cdex = 10 to Cdex = 40 mg mL-1. Moreover, λb did not exhibit substantial differences in blood with Cdex > 10 mg mL-1. The variations in λb were comparable to those of the previous method based on interface movement in the blood syringe. In conclusion, the WP could detect blood as well as diluents more effectively than λb. Furthermore, the proposed method substantially reduced the blood volume from 1 mL to 50 μL.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, Republic of Korea.
| |
Collapse
|
13
|
Kang YJ. Blood rheometer based on microflow manipulation of continuous blood flows using push-and-back mechanism. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4871-4883. [PMID: 34586112 DOI: 10.1039/d1ay00948f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
To understand the contributions of rheological properties to microcirculation, the simultaneous measurement of multiple rheological properties under continuous blood flows has been emphasized. However, existing methods exhibit limitations in terms of continuous and simultaneous monitoring. In this study, a simple method is suggested for simultaneously measuring four rheological properties (i.e., red blood cell (RBC) aggregation, blood viscosity, blood junction pressure, and RBC sedimentation) under a continuous blood flow. Using the push-and-back mechanism, which comprises a co-flowing channel, a test chamber, and an air compliance unit (ACU), blood is supplied to the test chamber and restored into the co-flowing channel periodically and reversely. First, RBC aggregation is quantified based on the intensity of the blood image in the test chamber. Second, blood viscosity and blood junction pressure are determined by analyzing the interface in the co-flowing channel. Lastly, RBC sedimentation is evaluated by analyzing the intensity of the blood image in the blood chamber. Based on quantitative studies involving several vital factors, the tubing length of ACU is set to L = 30 mm. The reference fluid (glycerin [20%]) is controlled in a periodic on-off manner (period = 240 s, and flow rate = 1 mL h-1). The blood flow rate is maintained at 1 mL h-1. Subsequently, the present method is used to determine the rheological properties of several blood samples with different hematocrits or diluents. Compared with previous studies, the present method yields sufficiently consistent trends with respect to the hematocrit level or concentration of dextran solution. The experimental results imply that the present method enables simultaneous and consistent measurements of four rheological properties of blood under continuous blood flows. This method can be regarded as a promising method for monitoring multiple rheological properties of blood circulating under an in vitro closed fluidic circuit.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, South Korea.
| |
Collapse
|
14
|
Kim G, Jeong S, Kang YJ. Ultrasound Standing Wave-Based Cell-to-liquid Separation for Measuring Viscosity and Aggregation of Blood Sample. SENSORS 2020; 20:s20082284. [PMID: 32316446 PMCID: PMC7219585 DOI: 10.3390/s20082284] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 04/12/2020] [Accepted: 04/15/2020] [Indexed: 11/16/2022]
Abstract
When quantifying mechanical properties of blood samples flowing in closed fluidic circuits, blood samples are collected at specific intervals. Centrifugal separation is considered as a required procedure for preparing blood samples. However, the use of centrifuge is associated with several issues, including the potential for red blood cell (RBC) lysis, clotting activation, and RBC adhesions in the tube. In this study, an ultrasonic transducer is employed to separate RBCs or diluent from blood sample. The ultrasonic radiation force is much smaller than the centrifugal force acting in centrifuge, it can avoid critical issues occurring under centrifuge. Then, the RBC aggregation and blood viscosity of the blood sample are obtained using the microfluidic technique. According to the numerical results, ultrasonic transducers exhibited a maximum quality factor at an excitation frequency of 2.1 MHz. Periodic pattern of acoustic pressure fields were visualized experimentally as a column mode. The half wavelength obtained was as 0.5 λ = 0.378 ± 0.07 mm. The experimental results agreed with the analytical estimation sufficiently. An acoustic power of 2 W was selected carefully for separating RBCs or diluent from various blood samples (i.e., Hct = 20% ~ 50%; diluent: plasma, 1x phosphate-buffered saline (PBS), and dextran solution). The present method was employed to separate fixed blood samples which tended to stack inside the tube while using the centrifuge. Fixed RBCs were collected easily with an ultrasonic transducer. After various fixed blood samples with different base solutions (i.e., glutaraldehyde solution, 1x PBS, and dextran solution) were prepared using the present method, RBC aggregation and the viscosity of the blood sample are successfully obtained. In the near future, the present method will be integrated into ex vivo or in vitro fluidic circuit for measuring multiple mechanical properties of blood samples for a certain longer period.
Collapse
Affiliation(s)
- Gwangho Kim
- PROTECHKOREA, 120-3 Nanosandan-ro, Samtae-ri, Nam-myeon, Jangseong-gun, Jeollanam-do 57248, Korea;
| | - Sanghwa Jeong
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
- Correspondence: (S.J.); (Y.J.K.); Tel.: +82-62-230-7178 (S.J.); +82-62-230-7052 (Y.J.K.); Fax: +82-62-230-7055 (S.J. & Y.J.K.)
| | - Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
- Correspondence: (S.J.); (Y.J.K.); Tel.: +82-62-230-7178 (S.J.); +82-62-230-7052 (Y.J.K.); Fax: +82-62-230-7055 (S.J. & Y.J.K.)
| |
Collapse
|
15
|
Kang YJ. Simultaneous measurement method of erythrocyte sedimentation rate and erythrocyte deformability in resource-limited settings. Physiol Meas 2020; 41:025009. [PMID: 32000147 DOI: 10.1088/1361-6579/ab71f3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE The individual effects of plasma and red blood cells (RBCs) on the biophysical properties of blood can be monitored by measuring the erythrocyte sedimentation rate (ESR) and RBC deformability simultaneously. However, the previous methods require bulky and expensive facilities (i.e. microscope, high-speed camera, and syringe pump) to deliver blood or capture blood flows. APPROACH To resolve these issues, a simple method for sequential measurement of the ESR and RBC deformability is demonstrated by quantifying the cell-free volume (V CF ), cell-rich volume (V CR ), and blood volume (V B ) inside an air-compressed syringe (ACS). A microfluidic device consists of multiple micropillar channels, an inlet, and outlet. After the ACS is filled with air (V air = 0.4 ml) and a blood sample (V B = 0.6 ml, hematocrit = 30%) sequentially, the ACS is fitted into the inlet. The cavity inside the ACS is compressed to V comp = 0.4 ml after closing the outlet with a stopper. A smartphone camera is employed to capture variations in the V CF , V CR , and V B inside the ACS. The ESR index suggested in this study (ESR PM ) is obtained by dividing the V CF (t = t 1) with an elapse of t 1. By removing the stopper, ΔV B (ΔV B = V B [t = t 1] - V B ) is obtained and fitted as a two-term exponential model ([Formula: see text]. As a performance demonstration, the proposed method is employed to detect an ESR-enhanced blood sample, homogeneous hardened blood sample, and heterogeneous blood sample. MAIN RESULTS From the experimental results, it is found that the proposed method has the ability to detect various bloods by quantifying the ESR PM and two coefficients (a, b) simultaneously. SIGNIFICANCE In conclusion, the present method can be effectively used to measure the ESR and RBC deformability in resource-limited settings.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
16
|
Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows. MICROMACHINES 2019; 10:mi10090577. [PMID: 31480325 PMCID: PMC6780160 DOI: 10.3390/mi10090577] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 08/23/2019] [Accepted: 08/28/2019] [Indexed: 12/18/2022]
Abstract
Aggregation of red blood cells (RBCs) varies substantially depending on changes of several factors such as hematocrit, membrane deformability, and plasma proteins. Among these factors, hematocrit has a strong influence on the aggregation of RBCs. Thus, while measuring RBCs aggregation, it is necessary to monitor hematocrit or, additionally, the effect of hematocrit (i.e., blood viscosity or pressure). In this study, the sequential measurement method of pressure and RBC aggregation is proposed by quantifying blood flow (i.e., velocity and image intensity) through a microfluidic device, in which an air-compressed syringe (ACS) is used to control the sample injection. The microfluidic device used is composed of two channels (pressure channel (PC), and blood channel (BC)), an inlet, and an outlet. A single ACS (i.e., air suction = 0.4 mL, blood suction = 0.4 mL, and air compression = 0.3 mL) is employed to supply blood into the microfluidic channel. At an initial time (t < 10 s), the pressure index (PI) is evaluated by analyzing the intensity of microscopy images of blood samples collected inside PC. During blood delivery with ACS, shear rates of blood flows vary continuously over time. After a certain amount of time has elapsed (t > 30 s), two RBC aggregation indices (i.e., SEAI: without information on shear rate, and erythrocyte aggregation index (EAI): with information on shear rate) are quantified by analyzing the image intensity and velocity field of blood flow in BC. According to experimental results, PI depends significantly on the characteristics of the blood samples (i.e., hematocrit or base solutions) and can be used effectively as an alternative to blood viscosity. In addition, SEAI and EAI also depend significantly on the degree of RBC aggregation. In conclusion, on the basis of three indices (two RBC aggregation indices and pressure index), the proposed method is capable of measuring RBCs aggregation consistently using a microfluidic device.
Collapse
|
17
|
Kang YJ, Lee SJ. In vitro and ex vivo measurement of the biophysical properties of blood using microfluidic platforms and animal models. Analyst 2019; 143:2723-2749. [PMID: 29740642 DOI: 10.1039/c8an00231b] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Haemorheologically impaired microcirculation, such as blood clotting or abnormal blood flow, causes interrupted blood flows in vascular networks. The biophysical properties of blood, including blood viscosity, blood viscoelasticity, haematocrit, red blood bell (RBC) aggregation, erythrocyte sedimentation rate and RBC deformability, have been used to monitor haematological diseases. In this review, we summarise several techniques for measuring haemorheological properties, such as blood viscosity, RBC deformability and RBC aggregation, using in vitro microfluidic platforms. Several methodologies for the measurement of haemorheological properties with the assistance of an extracorporeal rat bypass loop are also presented. We briefly discuss several emerging technologies for continuous, long-term, multiple measurements of haemorheological properties under in vitro or ex vivo conditions.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, Gwangju, Republic of Korea
| | | |
Collapse
|
18
|
Quantitative Measurement and Evaluation of Red Blood Cell Aggregation in Normal Blood Based on a Modified Hanai Equation. SENSORS 2019; 19:s19051095. [PMID: 30836669 PMCID: PMC6427202 DOI: 10.3390/s19051095] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 02/26/2019] [Accepted: 02/27/2019] [Indexed: 02/06/2023]
Abstract
The aggregation of red blood cells (RBCs) in normal blood (non-coagulation) has been quantitatively measured by blood pulsatile flow based on multiple-frequency electrical impedance spectroscopy. The relaxation frequencies fc under static and flowing conditions of blood pulsatile flow are utilized to evaluate the RBC aggregation quantitatively with the consideration of blood flow factors (RBC orientation, deformation, thickness of electrical double layer (EDL)). Both porcine blood and bovine blood are investigated in experiments, for the reason that porcine blood easily forms RBC aggregates, while bovine blood does not. The results show that the relaxation frequencies fc of porcine blood and bovine blood present opposite performance, which indicates that the proposed relaxation frequency fc is efficient to measure RBCs aggregation. Furthermore, the modified Hanai equation is proposed to quantitatively calculate the influence of RBCs aggregation on relaxation frequency fc. The study confirms the feasibility of a high speed, on-line RBC aggregation sensing method in extracorporeal circulation systems.
Collapse
|
19
|
Kang YJ. Simultaneous measurement of blood pressure and RBC aggregation by monitoring on–off blood flows supplied from a disposable air-compressed pump. Analyst 2019; 144:3556-3566. [DOI: 10.1039/c9an00025a] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
A simple method for simultaneously measuring RBC aggregation and blood pressure is demonstrated by analyzing blood flows supplied from a disposable air-compressed pump.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering
- Chosun University
- Gwangju
- Republic of Korea
| |
Collapse
|
20
|
Lee Y, Kim B, Oh I, Choi S. Optofluidic Modular Blocks for On-Demand and Open-Source Prototyping of Microfluidic Systems. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1802769. [PMID: 30375722 DOI: 10.1002/smll.201802769] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 10/17/2018] [Indexed: 05/24/2023]
Abstract
Rapid prototyping of microfluidic devices has advanced greatly, along with the development of 3D printing and micromachining technologies. However, peripheral systems for microfluidics still rely on conventional equipment, such as bench-top microscopy and syringe pumps, which limit system modification and further improvements. Herein, optofluidic modular blocks are presented as discrete elements to modularize peripheral optical and fluidic systems and are used for on-demand and open-source prototyping of whole microfluidic systems. Each modular block is fabricated by embedding optical or fluidic devices into the corresponding 3D-printed housing. The self-interlocking structure of the modular blocks enables easy assembly and reconfiguration of the blocks in an intuitive manner, while also providing precise optical and fluidic alignment between the blocks. With the library of standardized modular blocks developed here, how the blocks can be easily assembled to build whole microfluidic systems for blood compatibility testing, droplet microfluidics, and cell migration assays is demonstrated. Based on the simplicity of assembling the optofluidic blocks, the prototyping platform can be easily used for open-source sharing of digital design files, assembly and operation instructions, and block specifications, thereby making it easy for nonexperts to implement microfluidic ideas as physical systems.
Collapse
Affiliation(s)
- Yujin Lee
- Department of Biomedical Engineering, Kyung Hee University, Yongin-si, Gyeonggi-do, 17104, Republic of Korea
| | - Byeongyeon Kim
- Department of Biomedical Engineering, Kyung Hee University, Yongin-si, Gyeonggi-do, 17104, Republic of Korea
| | - Insung Oh
- Department of Biomedical Engineering, Kyung Hee University, Yongin-si, Gyeonggi-do, 17104, Republic of Korea
| | - Sungyoung Choi
- Department of Biomedical Engineering, Kyung Hee University, Yongin-si, Gyeonggi-do, 17104, Republic of Korea
| |
Collapse
|
21
|
Kang YJ. A Disposable Blood-on-a-Chip for Simultaneous Measurement of Multiple Biophysical Properties. MICROMACHINES 2018; 9:E475. [PMID: 30424408 PMCID: PMC6215101 DOI: 10.3390/mi9100475] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Revised: 09/15/2018] [Accepted: 09/17/2018] [Indexed: 12/11/2022]
Abstract
Biophysical properties are widely used to detect pathophysiological processes of vascular diseases or clinical states. For early detection of cardiovascular diseases, it is necessary to simultaneously measure multiple biophysical properties in a microfluidic environment. However, a microfluidic-based technique for measuring multiple biophysical properties has not been demonstrated. In this study, a simple measurement method was suggested to quantify three biophysical properties of blood, including red blood cell (RBC) deformability, RBC aggregation, and hematocrit. To demonstrate the suggested method, a microfluidic device was constructed, being composed of a big-sized channel (BC), a parallel micropillar (MP), a main channel, a branch channel, inlet, and outlets. By operating a single syringe pump, blood was supplied into the inlet of the microfluidic device, at a periodic on-off profile (i.e., period = 240 s). The RBC deformability index (DI) was obtained by analyzing the averaged blood velocity in the branch channel. Additionally, the RBC aggregation index (AIN) and the hematocrit index (HiBC) were measured by analyzing the image intensity of blood flows in the MP and the BC, respectively. The corresponding contributions of three influencing factors, including the turn-on time (Ton), the amplitude of blood flow rate (Q₀), and the hematocrit (Hct) on the biophysical indices (DI, AIN, and HiBC) were evaluated quantitatively. As the three biophysical indices varied significantly with respect to the three factors, the following conditions (i.e., Ton = 210 s, Q₀ = 1 mL/h, and Hct = 50%) were maintained for consistent measurement of biophysical properties. The proposed method was employed to detect variations of biophysical properties depending on the concentrations of autologous plasma, homogeneous hardened RBCs, and heterogeneous hardened RBCs. Based on the observations, the proposed method exhibited significant differences in biophysical properties depending on base solutions, homogeneous hardened RBCs (i.e., all RBCs fixed with the same concentration of glutaraldehyde solution), and heterogeneous hardened RBCs (i.e., partially mixed with normal RBCs and homogeneous hardened RBCs). Additionally, the suggested indices (i.e., DI, AIN, and HiBC) were effectively employed to quantify three biophysical properties, including RBC deformability, RBC aggregation, and hematocrit.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea.
| |
Collapse
|
22
|
Kang YJ. Microfluidic-Based Technique for Measuring RBC Aggregation and Blood Viscosity in a Continuous and Simultaneous Fashion. MICROMACHINES 2018; 9:E467. [PMID: 30424400 PMCID: PMC6187833 DOI: 10.3390/mi9090467] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 09/06/2018] [Accepted: 09/11/2018] [Indexed: 01/04/2023]
Abstract
Hemorheological properties such as viscosity, deformability, and aggregation have been employed to monitor or screen patients with cardiovascular diseases. To effectively evaluate blood circulating within an in vitro closed circuit, it is important to quantify its hemorheological properties consistently and accurately. A simple method for measuring red blood cell (RBC) aggregation and blood viscosity is proposed for analyzing blood flow in a microfluidic device, especially in a continuous and simultaneous fashion. To measure RBC aggregation, blood flows through three channels: the left wide channel, the narrow channel and the right wide channel sequentially. After quantifying the image intensity of RBCs aggregated in the left channel () and the RBCs disaggregated in the right channel (), the RBC aggregation index (AIPM) is obtained by dividing by . Simultaneously, based on a modified parallel flow method, blood viscosity is obtained by detecting the interface between two fluids in the right wide channel. RBC aggregation and blood viscosity were first evaluated under constant and pulsatile blood flows. AIPM varies significantly with respect to blood flow rate (for both its amplitude and period) and the concentration of the dextran solution used. According to our quantitative comparison between the proposed aggregation index (AIPM) and the conventional aggregation index (AICM), it is found that AIPM provides consistent results. Finally, the suggested method is employed to obtain the RBC aggregation and blood viscosity of blood circulating within an in vitro fluidic circuit. The experimental results lead to the conclusion that the proposed method can be successfully used to measure RBC aggregation and blood viscosity, especially in a continuous and simultaneous fashion.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea.
| |
Collapse
|
23
|
Kang YJ, Kim BJ. Multiple and Periodic Measurement of RBC Aggregation and ESR in Parallel Microfluidic Channels under On-Off Blood Flow Control. MICROMACHINES 2018; 9:mi9070318. [PMID: 30424251 PMCID: PMC6082273 DOI: 10.3390/mi9070318] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Revised: 06/13/2018] [Accepted: 06/21/2018] [Indexed: 01/25/2023]
Abstract
Red blood cell (RBC) aggregation causes to alter hemodynamic behaviors at low flow-rate regions of post-capillary venules. Additionally, it is significantly elevated in inflammatory or pathophysiological conditions. In this study, multiple and periodic measurements of RBC aggregation and erythrocyte sedimentation rate (ESR) are suggested by sucking blood from a pipette tip into parallel microfluidic channels, and quantifying image intensity, especially through single experiment. Here, a microfluidic device was prepared from a master mold using the xurography technique rather than micro-electro-mechanical-system fabrication techniques. In order to consider variations of RBC aggregation in microfluidic channels due to continuous ESR in the conical pipette tip, two indices (aggregation index (AI) and erythrocyte-sedimentation-rate aggregation index (EAI)) are evaluated by using temporal variations of microscopic, image-based intensity. The proposed method is employed to evaluate the effect of hematocrit and dextran solution on RBC aggregation under continuous ESR in the conical pipette tip. As a result, EAI displays a significantly linear relationship with modified conventional ESR measurement obtained by quantifying time constants. In addition, EAI varies linearly within a specific concentration of dextran solution. In conclusion, the proposed method is able to measure RBC aggregation under continuous ESR in the conical pipette tip. Furthermore, the method provides multiple data of RBC aggregation and ESR through a single experiment. A future study will involve employing the proposed method to evaluate biophysical properties of blood samples collected from cardiovascular diseases.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea.
| | - Byung Jun Kim
- Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| |
Collapse
|
24
|
Kang YJ. Periodic and simultaneous quantification of blood viscosity and red blood cell aggregation using a microfluidic platform under in-vitro closed-loop circulation. BIOMICROFLUIDICS 2018; 12:024116. [PMID: 29682144 PMCID: PMC5891346 DOI: 10.1063/1.5017052] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Accepted: 03/29/2018] [Indexed: 05/13/2023]
Abstract
To evaluate variations of blood circulating in closed loops, hemorheological properties including blood viscosity and red blood cells (RBCs) are quantitatively measured with independent in-vitro instruments after collecting blood from a closed loop. But, most previous methods require periodic blood collections which induce several problems such as geometric differences between the fluidic channel and the in-vitro method, hemodilution, storage time, and unspecific blood flow rates. To resolve these issues, in this study, blood viscosity and RBC aggregation of blood circulating within a closed loop are measured with a microfluidic platform periodically and simultaneously. To demonstrate the proposed method, in-vitro closed-loop circulation is established by connecting several components (peristaltic pump, air compliance unit, fluid divider, and reservoir) in series. In addition, to measure blood viscosity and RBC aggregation, a microfluidic platform composed of a microfluidic device, pinch valve, and syringe pump is created. During each period, blood viscosity and RBC aggregation are measured by monitoring blood flow at constant blood flow, and image intensity at stationary blood flow. The proposed method is first employed to evaluate the effect of hematocrits and dextran concentrations on the RBC aggregation and blood viscosity by using a syringe pump (i.e., specific blood flow-rate). The method is then applied to detect the blood viscosity and RBC aggregation under in-vitro closed-loop circulation (i.e., unspecific blood flow-rate). From these experimental demonstrations, it is found that the suggested method can be effectively used to monitor the RBC aggregation and blood viscosity under in-vitro closed-loop circulation. Since this method does not require periodic collection from closed-loop circulation or an additional procedure for estimating blood flow-rate with a syringe pump, it will be effectively used to monitor variations of blood circulating in extracorporeal bypass loops.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, South Korea
| |
Collapse
|