1
|
Grangeat P, Duval Comsa MP, Koenig A, Phlypo R. Dynamic Modeling of Carbon Dioxide Transport through the Skin Using a Capnometry Wristband. SENSORS (BASEL, SWITZERLAND) 2023; 23:6096. [PMID: 37447945 DOI: 10.3390/s23136096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/26/2023] [Accepted: 06/28/2023] [Indexed: 07/15/2023]
Abstract
The development of a capnometry wristband is of great interest for monitoring patients at home. We consider a new architecture in which a non-dispersive infrared (NDIR) optical measurement is located close to the skin surface and is combined with an open chamber principle with a continuous circulation of air flow in the collection cell. We propose a model for the temporal dynamics of the carbon dioxide exchange between the blood and the gas channel inside the device. The transport of carbon dioxide is modeled by convection-diffusion equations. We consider four compartments: blood, skin, the measurement cell and the collection cell. We introduce the state-space equations and the associated transition matrix associated with a Markovian model. We define an augmented system by combining a first-order autoregressive model describing the supply of carbon dioxide concentration in the blood compartment and its inertial resistance to change. We propose to use a Kalman filter to estimate the carbon dioxide concentration in the blood vessels recursively over time and thus monitor arterial carbon dioxide blood pressure in real time. Four performance factors with respect to the dynamic quantification of the CO2 blood concentration are considered, and a simulation is carried out based on data from a previous clinical study. These demonstrate the feasibility of such a technological concept.
Collapse
Affiliation(s)
- Pierre Grangeat
- CEA, Leti, MINATEC Campus, Université Grenoble Alpes, F-38000 Grenoble, France
| | | | - Anne Koenig
- CEA, Leti, MINATEC Campus, Université Grenoble Alpes, F-38000 Grenoble, France
| | - Ronald Phlypo
- CNRS, Grenoble INP, GIPSA-Lab, Université Grenoble Alpes, F-38000 Grenoble, France
| |
Collapse
|
2
|
Dervieux E, Théron M, Uhring W. Carbon Dioxide Sensing-Biomedical Applications to Human Subjects. SENSORS (BASEL, SWITZERLAND) 2021; 22:188. [PMID: 35009731 PMCID: PMC8749784 DOI: 10.3390/s22010188] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/13/2021] [Accepted: 12/20/2021] [Indexed: 02/06/2023]
Abstract
Carbon dioxide (CO2) monitoring in human subjects is of crucial importance in medical practice. Transcutaneous monitors based on the Stow-Severinghaus electrode make a good alternative to the painful and risky arterial "blood gases" sampling. Yet, such monitors are not only expensive, but also bulky and continuously drifting, requiring frequent recalibrations by trained medical staff. Aiming at finding alternatives, the full panel of CO2 measurement techniques is thoroughly reviewed. The physicochemical working principle of each sensing technique is given, as well as some typical merit criteria, advantages, and drawbacks. An overview of the main CO2 monitoring methods and sites routinely used in clinical practice is also provided, revealing their constraints and specificities. The reviewed CO2 sensing techniques are then evaluated in view of the latter clinical constraints and transcutaneous sensing coupled to a dye-based fluorescence CO2 sensing seems to offer the best potential for the development of a future non-invasive clinical CO2 monitor.
Collapse
Affiliation(s)
- Emmanuel Dervieux
- BiOSENCY, 1137a Avenue des Champs Blancs, 35510 Cesson-Sévigné, France
| | - Michaël Théron
- ORPHY, Université de Bretagne Occidentale, 6 Avenue Victor le Gorgeu, 29238 Brest, France;
| | - Wilfried Uhring
- ICube, University of Strasbourg and CNRS, 23 rue du Loess, CEDEX, 67037 Strasbourg, France;
| |
Collapse
|
3
|
Esfahani S, Tiele A, Agbroko SO, Covington JA. Development of a Tuneable NDIR Optical Electronic Nose. SENSORS 2020; 20:s20236875. [PMID: 33271862 PMCID: PMC7729477 DOI: 10.3390/s20236875] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 11/22/2020] [Accepted: 11/27/2020] [Indexed: 01/01/2023]
Abstract
Electronic nose (E-nose) technology provides an easy and inexpensive way to analyse chemical samples. In recent years, there has been increasing demand for E-noses in applications such as food safety, environmental monitoring and medical diagnostics. Currently, the majority of E-noses utilise an array of metal oxide (MOX) or conducting polymer (CP) gas sensors. However, these sensing technologies can suffer from sensor drift, poor repeatability and temperature and humidity effects. Optical gas sensors have the potential to overcome these issues. This paper reports on the development of an optical non-dispersive infrared (NDIR) E-nose, which consists of an array of four tuneable detectors, able to scan a range of wavelengths (3.1–10.5 μm). The functionality of the device was demonstrated in a series of experiments, involving gas rig tests for individual chemicals (CO2 and CH4), at different concentrations, and discriminating between chemical standards and complex mixtures. The optical gas sensor responses were shown to be linear to polynomial for different concentrations of CO2 and CH4. Good discrimination was achieved between sample groups. Optical E-nose technology therefore demonstrates significant potential as a portable and low-cost solution for a number of E-nose applications.
Collapse
|
4
|
Dospinescu VM, Tiele A, Covington JA. Sniffing Out Urinary Tract Infection-Diagnosis Based on Volatile Organic Compounds and Smell Profile. BIOSENSORS 2020; 10:E83. [PMID: 32717983 PMCID: PMC7460005 DOI: 10.3390/bios10080083] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/19/2020] [Accepted: 07/20/2020] [Indexed: 02/08/2023]
Abstract
Current available methods for the clinical diagnosis of urinary tract infection (UTI) rely on a urine dipstick test or culturing of pathogens. The dipstick test is rapid (available in 1-2 min), but has a low positive predictive value, while culturing is time-consuming and delays diagnosis (24-72 h between sample collection and pathogen identification). Due to this delay, broad-spectrum antibiotics are often prescribed immediately. The over-prescription of antibiotics should be limited, in order to prevent the development of antimicrobial resistance. As a result, there is a growing need for alternative diagnostic tools. This paper reviews applications of chemical-analysis instruments, such as gas chromatography-mass spectrometry (GC-MS), selected ion flow tube mass spectrometry (SIFT-MS), ion mobility spectrometry (IMS), field asymmetric ion mobility spectrometry (FAIMS) and electronic noses (eNoses) used for the diagnosis of UTI. These methods analyse volatile organic compounds (VOCs) that emanate from the headspace of collected urine samples to identify the bacterial pathogen and even determine the causative agent's resistance to different antibiotics. There is great potential for these technologies to gain wide-spread and routine use in clinical settings, since the analysis can be automated, and test results can be available within minutes after sample collection. This could significantly reduce the necessity to prescribe broad-spectrum antibiotics and allow the faster and more effective use of narrow-spectrum antibiotics.
Collapse
Affiliation(s)
| | - Akira Tiele
- School of Engineering, University of Warwick, Coventry CV4 7AL, UK;
| | | |
Collapse
|
5
|
Grangeat P, Gharbi S, Accensi M, Grateau H. First Evaluation of a Transcutaneous Carbon Dioxide Monitoring Wristband Device during a Cardiopulmonary Exercise Test .. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:3352-3355. [PMID: 31946599 DOI: 10.1109/embc.2019.8857020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We introduce an innovative wristband wireless device based on a dual wavelength NDIR optical measurement and an optimized thermo-fluidic channel to improve the extraction of the carbon dioxide gas from the blood within the heated skin region. We describe a signal processing model combining an innovative linear quadratic model of the optical measurement and a fluidic model. The evaluation is achieved using a cardiopulmonary exercise test (CPET). We compare carbon dioxide tension measurement at the forearm level using our device, with an electrochemical measurement at the forearm level, and an optical measurement of the end-tidal exhaled breath. These curves demonstrate a significant reduction of the variability of carbon dioxide pressure measurement with respect to the pressure dynamic range during the test.
Collapse
|
6
|
Abstract
In this paper, we report on an in-house developed electronic nose (E-nose) for use with breath analysis. The unit consists of an array of 10 micro-electro-mechanical systems (MEMS) metal oxide (MOX) gas sensors produced by seven manufacturers. Breath sampling of end-tidal breath is achieved using a heated sample tube, capable of monitoring sampling-related parameters, such as carbon dioxide (CO2), humidity, and temperature. A simple mobile app was developed to receive real-time data from the device, using Wi-Fi communication. The system has been tested using chemical standards and exhaled breath samples from healthy volunteers, before and after taking a peppermint capsule. Results from chemical testing indicate that we can separate chemical standards (acetone, isopropanol and 1-propanol) and different concentrations of isobutylene. The analysis of exhaled breath samples demonstrate that we can distinguish between pre- and post-consumption of peppermint capsules; area under the curve (AUC): 0.81, sensitivity: 0.83 (0.59–0.96), specificity: 0.72 (0.47–0.90), p-value: <0.001. The functionality of the developed device has been demonstrated with the testing of chemical standards and a simplified breath study using peppermint capsules. It is our intention to deploy this system in a UK hospital in an upcoming breath research study.
Collapse
|
7
|
A Gas Mixture Prediction Model Based on the Dynamic Response of a Metal-Oxide Sensor. MICROMACHINES 2019; 10:mi10090598. [PMID: 31514357 PMCID: PMC6780764 DOI: 10.3390/mi10090598] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 08/29/2019] [Accepted: 09/10/2019] [Indexed: 11/25/2022]
Abstract
Metal-oxide (MOX) gas sensors are widely used for gas concentration estimation and gas identification due to their low cost, high sensitivity, and stability. However, MOX sensors have low selectivity to different gases, which leads to the problem of classification for mixtures and pure gases. In this study, a square wave was applied as the heater waveform to generate a dynamic response on the sensor. The information of the dynamic response, which includes different characteristics for different gases due to temperature changes, enhanced the selectivity of the MOX sensor. Moreover, a polynomial interaction term mixture model with a dynamic response is proposed to predict the concentration of the binary mixtures and pure gases. The proposed method improved the classification accuracy to 100%. Moreover, the relative error of quantification decreased to 1.4% for pure gases and 13.0% for mixtures.
Collapse
|
8
|
Application of an Array of Metal-Oxide Semiconductor Gas Sensors in an Assistant Personal Robot for Early Gas Leak Detection. SENSORS 2019; 19:s19091957. [PMID: 31027330 PMCID: PMC6540054 DOI: 10.3390/s19091957] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 04/15/2019] [Accepted: 04/23/2019] [Indexed: 11/23/2022]
Abstract
This paper proposes the application of a low-cost gas sensor array in an assistant personal robot (APR) in order to extend the capabilities of the mobile robot as an early gas leak detector for safety purposes. The gas sensor array is composed of 16 low-cost metal-oxide (MOX) gas sensors, which are continuously in operation. The mobile robot was modified to keep the gas sensor array always switched on, even in the case of battery recharge. The gas sensor array provides 16 individual gas measurements and one output that is a cumulative summary of all measurements, used as an overall indicator of a gas concentration change. The results of preliminary experiments were used to train a partial least squares discriminant analysis (PLS-DA) classifier with air, ethanol, and acetone as output classes. Then, the mobile robot gas leak detection capabilities were experimentally evaluated in a public facility, by forcing the evaporation of (1) ethanol, (2) acetone, and (3) ethanol and acetone at different locations. The positive results obtained in different operation conditions over the course of one month confirmed the early detection capabilities of the proposed mobile system. For example, the APR was able to detect a gas leak produced inside a closed room from the external corridor due to small leakages under the door induced by the forced ventilation system of the building.
Collapse
|
9
|
Zhang H, Qin H, Gao C, Hu J. An Ultrahigh Sensitivity Acetone Sensor Enhanced by Light Illumination. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2318. [PMID: 30018252 PMCID: PMC6068944 DOI: 10.3390/s18072318] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 07/13/2018] [Accepted: 07/15/2018] [Indexed: 11/22/2022]
Abstract
Au:SmFe0.9Zn0.1O₃ is synthesized by a sol-gel method and annealed at 750 °C. Through XRD, SEM and XPS analysis methods, the microstructure of the material has been observed. The average particle size is about 50 nm. The sensor shows a high sensitivity toward acetone vapor. As the relative humidity increases, the resistance and sensitivity of the sensor decline. To obtain a low optimum operating temperature, light illumination with different wavelengths has been introduced. The sensitivity toward acetone is improved at lower operating temperature when the sensor is irradiated by light. The smaller the wavelengths, the better the sensitivity of the sensor. Compared with other gases, the sensor shows excellent selectivity to acetone vapor, with better sensitivity, selectivity and stability when under light illumination.
Collapse
Affiliation(s)
- Heng Zhang
- School of Physics, State Key Laboratory for Crystal Materials, Shandong University, Jinan 250100, China.
| | - Hongwei Qin
- School of Physics, State Key Laboratory for Crystal Materials, Shandong University, Jinan 250100, China.
| | - Chengyong Gao
- School of Physics, State Key Laboratory for Crystal Materials, Shandong University, Jinan 250100, China.
| | - Jifan Hu
- School of Physics, State Key Laboratory for Crystal Materials, Shandong University, Jinan 250100, China.
| |
Collapse
|