1
|
Zhou J, Li Y, Zhang J, Cai F. Developing a Portable Autofluorescence Detection System and Its Application in Biological Samples. SENSORS (BASEL, SWITZERLAND) 2024; 24:3351. [PMID: 38894145 PMCID: PMC11174582 DOI: 10.3390/s24113351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Revised: 05/14/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024]
Abstract
Advanced glycation end-products (AGEs) are complex compounds closely associated with several chronic diseases, especially diabetes mellitus (DM). Current methods for detecting AGEs are not suitable for screening large populations, or for long-term monitoring. This paper introduces a portable autofluorescence detection system that measures the concentration of AGEs in the skin based on the fluorescence characteristics of AGEs in biological tissues. The system employs a 395 nm laser LED to excite the fluorescence of AGEs, and uses a photodetector to capture the fluorescence intensity. A model correlating fluorescence intensity with AGEs concentration facilitates the detection of AGEs levels. To account for the variation in optical properties of different individuals' skin, the system includes a 520 nm light source for calibration. The system features a compact design, measuring only 60 mm × 50 mm × 20 mm, and is equipped with a miniature STM32 module for control and a battery for extended operation, making it easy for subjects to wear. To validate the system's effectiveness, it was tested on 14 volunteers to examine the correlation between AGEs and glycated hemoglobin, revealing a correlation coefficient of 0.49. Additionally, long-term monitoring of AGEs' fluorescence and blood sugar levels showed a correlation trend exceeding 0.95, indicating that AGEs reflect changes in blood sugar levels to some extent. Further, by constructing a multivariate predictive model, the study also found that AGEs levels are correlated with age, BMI, gender, and a physical activity index, providing new insights for predicting AGEs content and blood sugar levels. This research supports the early diagnosis and treatment of chronic diseases such as diabetes, and offers a potentially useful tool for future clinical applications.
Collapse
Affiliation(s)
| | - Yunfei Li
- School of Biomedical Engineering, Hainan University, Sanya 572000, China; (J.Z.); (J.Z.); (F.C.)
| | | | | |
Collapse
|
2
|
Hassan RO, Othman HO, Ali DS. New spectrophotometric and smartphone-based colorimetric methods for determination of atenolol in pharmaceutical formulations. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 302:123009. [PMID: 37330334 DOI: 10.1016/j.saa.2023.123009] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/25/2023] [Accepted: 06/10/2023] [Indexed: 06/19/2023]
Abstract
Novel spectrophotometric and smartphone-based colorimetric methods were developed and validated for the estimation of atenolol (ATE) in pharmaceutical formulations. The measurement procedure is based on the de-diazotization reaction, in which ATE is able to inhibit the diazotized sulfanilic acid from reacting with 8-hydroxy quinoline (8-HQ) in a basic medium. As a result, the formation of red-orange color azo-dye is hindered, and the color intensity is decreased proportionally to concentration of ATE. In spectrophotometric method the azo-dye color fate was monitored at 495 nm. While in smartphone-based colorimetric (SBC) method the captured image in the design processed by RGB App and transferred to the absorbance. The reactant concentrations were optimized using a central composite design (CCD) and response surface method. The methods exhibit good linearity in the 8.0 to 60.0 µg mL-1 range with no significant effect of interferences. The spectrophotometric method yields a linear equation with a slope of 0.0187 (R2 = 0.9993), a limit of detection (LOD) of 1.28 µg mL-1, and a limit of quantification (LOQ) of 4.28 µg mL-1. On the other hand, the smartphone-based colorimetric (SBC) method demonstrates a linear equation with a slope of 0.0127 (R2 = 0.9965), an LOD of 2.13 µg mL-1, and an LOQ of 7.09 µg mL-1. Analyzing ATE in pharmaceutical tablets was utilized to validate the applicability of the developed methods, and the results were statistically compared with those obtained by the HPLC method using the t-test and F-test.
Collapse
Affiliation(s)
- Rebwar Omar Hassan
- Department of Chemistry, College of Science, Salahaddin University, Erbil-Kurdistan Region, Iraq.
| | - Hazha Omar Othman
- Department of Chemistry, College of Science, Salahaddin University, Erbil-Kurdistan Region, Iraq; Pharmacy Department, Faculty of Pharmacy, Tishk International University, Erbil-Kurdistan Region, Iraq
| | - Diyar Salahuddin Ali
- Department of Chemistry, College of Science, Salahaddin University, Erbil-Kurdistan Region, Iraq; Department of Medical Laboratory Science, College of Science, Knowledge University, Erbil-Kurdistan Region, Iraq
| |
Collapse
|
3
|
Mao Y, Betters CH, Garske S, Randle J, Wong KC, Cairns IH, Evans BJ. A Customisable Data Acquisition System for Open-Source Hyperspectral Imaging. SENSORS (BASEL, SWITZERLAND) 2023; 23:8622. [PMID: 37896715 PMCID: PMC10611323 DOI: 10.3390/s23208622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Revised: 10/17/2023] [Accepted: 10/17/2023] [Indexed: 10/29/2023]
Abstract
Hyperspectral imagers, or imaging spectrometers, are used in many remote sensing environmental studies in fields such as agriculture, forestry, geology, and hydrology. In recent years, compact hyperspectral imagers were developed using commercial-off-the-shelf components, but there are not yet any off-the-shelf data acquisition systems on the market to deploy them. The lack of a self-contained data acquisition system with navigation sensors is a challenge that needs to be overcome to successfully deploy these sensors on remote platforms such as drones and aircraft. Our work is the first successful attempt to deploy an entirely open-source system that is able to collect hyperspectral and navigation data concurrently for direct georeferencing. In this paper, we describe a low-cost, lightweight, and deployable data acquisition device for the open-source hyperspectral imager (OpenHSI). We utilised commercial-off-the-shelf hardware and open-source software to create a compact data acquisition device that can be easily transported and deployed. The device includes a microcontroller and a custom-designed PCB board to interface with ancillary sensors and a Raspberry Pi 4B/NVIDIA Jetson. We demonstrated our data acquisition system on a Matrice M600 drone at a beach in Sydney, Australia, collecting timestamped hyperspectral, navigation, and orientation data in parallel. Using the navigation and orientation data, the hyperspectral data were georeferenced. While the entire system including the pushbroom hyperspectral imager and housing weighed 735 g, it was designed to be easy to assemble and modify. This low-cost, customisable, deployable data acquisition system provides a cost-effective solution for the remote sensing of hyperspectral data for everyone.
Collapse
Affiliation(s)
- Yiwei Mao
- School of Physics, The University of Sydney, Sydney, NSW 2006, Australia; (Y.M.); (C.H.B.)
- ARC Training Centre for CubeSats UAVs and Their Applications, The University of Sydney, Sydney, NSW 2006, Australia; (S.G.); (K.C.W.); (B.J.E.)
| | - Christopher H. Betters
- School of Physics, The University of Sydney, Sydney, NSW 2006, Australia; (Y.M.); (C.H.B.)
- ARC Training Centre for CubeSats UAVs and Their Applications, The University of Sydney, Sydney, NSW 2006, Australia; (S.G.); (K.C.W.); (B.J.E.)
| | - Samuel Garske
- ARC Training Centre for CubeSats UAVs and Their Applications, The University of Sydney, Sydney, NSW 2006, Australia; (S.G.); (K.C.W.); (B.J.E.)
| | - Jeremy Randle
- Australian Centre for Field Robotics, The University of Sydney, Sydney, NSW 2006, Australia;
| | - K. C. Wong
- ARC Training Centre for CubeSats UAVs and Their Applications, The University of Sydney, Sydney, NSW 2006, Australia; (S.G.); (K.C.W.); (B.J.E.)
| | - Iver H. Cairns
- School of Physics, The University of Sydney, Sydney, NSW 2006, Australia; (Y.M.); (C.H.B.)
- ARC Training Centre for CubeSats UAVs and Their Applications, The University of Sydney, Sydney, NSW 2006, Australia; (S.G.); (K.C.W.); (B.J.E.)
| | - Bradley J. Evans
- ARC Training Centre for CubeSats UAVs and Their Applications, The University of Sydney, Sydney, NSW 2006, Australia; (S.G.); (K.C.W.); (B.J.E.)
- School of Environment and Rural Science, University of New England, Armidale, NSW 2351, Australia
| |
Collapse
|
4
|
OpenHSI: A Complete Open-Source Hyperspectral Imaging Solution for Everyone. REMOTE SENSING 2022. [DOI: 10.3390/rs14092244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OpenHSI is an initiative to lower the barriers of entry and bring compact pushbroom hyperspectral imaging spectrometers to a wider audience. We present an open-source optical design that can be replicated with readily available commercial-off-the-shelf components, and an open-source software platform openhsi that simplifies the process of capturing calibrated hyperspectral datacubes. Some of the features that the software stack provides include: an ISO 19115-2 metadata editor, wavelength calibration, a fast smile correction method, radiance conversion, atmospheric correction using 6SV (an open-source radiative transfer code), and empirical line calibration. A pipeline was developed to customise the desired processing and make openhsi practical for real-time use. We used the OpenHSI optical design and software stack successfully in the field and verified the performance using calibration tarpaulins. By providing all the tools needed to collect documented hyperspectral datasets, our work empowers practitioners who may not have the financial or technical capability to operate commercial hyperspectral imagers, and opens the door for applications in new problem domains.
Collapse
|
5
|
Wang T, Shen F, Deng H, Cai F, Chen S. Smartphone imaging spectrometer for egg/meat freshness monitoring. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:508-517. [PMID: 35050274 DOI: 10.1039/d1ay01726h] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Data transmission between spectroscopy equipment and mobile terminals is critical to realising hand-held field-level monitoring. Currently, on-the-go (OTG) communication technology is a convenient and efficient method of data transmission for mobile devices. However, few people associate spectroscopy equipment with smartphones through the OTG port. This study developed a portable imaging spectrometer with a spectral resolution of approximately 12 nm in the visible-near-infrared band (400-1000 nm). It can be connected to a smartphone through the USB-OTG port to process the spectral signal through the smartphone's system on a chip (SoC). It also displays real-time spectral images of the food samples through the smartphone's screen. Using a support vector machine (SVM) to classify the spectra of the various experimental samples (e.g. eggs and pork), the model prediction accuracy rate is approximately 90%. This further proves the reliability of the proposed smartphone imaging spectrometer for monitoring the freshness of food samples onsite.
Collapse
Affiliation(s)
- Tianci Wang
- Mechanical and Electrical Engineering College, School of Biomedical Engineering, Key Laboratory of Biomedical Engineering of Hainan Province, Hainan University, Haikou 570228, China.
| | - Fuzhou Shen
- Mechanical and Electrical Engineering College, School of Biomedical Engineering, Key Laboratory of Biomedical Engineering of Hainan Province, Hainan University, Haikou 570228, China.
| | - Hancheng Deng
- Mechanical and Electrical Engineering College, School of Biomedical Engineering, Key Laboratory of Biomedical Engineering of Hainan Province, Hainan University, Haikou 570228, China.
| | - Fuhong Cai
- Mechanical and Electrical Engineering College, School of Biomedical Engineering, Key Laboratory of Biomedical Engineering of Hainan Province, Hainan University, Haikou 570228, China.
| | - Shufen Chen
- Hainan General Hospital (Hainan Affiliated Hospital of Hainan Medical University), Haikou, Hainan, China
| |
Collapse
|
6
|
Luo L, Li S, Yao X, He S. Rotational hyperspectral scanner and related image reconstruction algorithm. Sci Rep 2021; 11:3296. [PMID: 33558585 PMCID: PMC7870810 DOI: 10.1038/s41598-021-82819-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 01/25/2021] [Indexed: 12/25/2022] Open
Abstract
We design and implement a compact and lightweight hyperspectral scanner. Based on this, a novel rotational hyperspectral scanner was demonstrated. Different from translational scanning, rotational scanning is a moveless and stable scanning method. We also designed a relevant image algorithm to reconstruct the image from an angular recorded hyperspectral data cube. The algorithm works well even with uncertain radial and tangential offset, which is caused by mechanical misalignment. The system shown a spectral resolution of 5 nm after calibration. Finally, spatial accuracy and spectral precision were discussed, based on some additional experiments.
Collapse
Affiliation(s)
- Longqiang Luo
- College of Optical Science and Engineering, Zhejiang University, 866 Yuhangtang Rd, Hangzhou, 310058, China
| | - Shuo Li
- College of Optical Science and Engineering, Zhejiang University, 866 Yuhangtang Rd, Hangzhou, 310058, China.,Ningbo Research Institute, Zhejiang University, Ningbo, 315100, China
| | - Xinli Yao
- College of Optical Science and Engineering, Zhejiang University, 866 Yuhangtang Rd, Hangzhou, 310058, China
| | - Sailing He
- College of Optical Science and Engineering, Zhejiang University, 866 Yuhangtang Rd, Hangzhou, 310058, China. .,Ningbo Research Institute, Zhejiang University, Ningbo, 315100, China. .,Department of Electromagnetic Engineering, School of Electrical Engineering, KTH Royal Institute of Technology, 100 44, Stockholm, Sweden.
| |
Collapse
|
7
|
Yao X, Cai F, Zhu P, Fang H, Li J, He S. Non-invasive and rapid pH monitoring for meat quality assessment using a low-cost portable hyperspectral scanner. Meat Sci 2019; 152:73-80. [DOI: 10.1016/j.meatsci.2019.02.017] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Revised: 02/22/2019] [Accepted: 02/22/2019] [Indexed: 01/28/2023]
|
8
|
Yeong TJ, Pin Jern K, Yao LK, Hannan MA, Hoon STG. Applications of Photonics in Agriculture Sector: A Review. Molecules 2019; 24:E2025. [PMID: 31137897 PMCID: PMC6571790 DOI: 10.3390/molecules24102025] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 05/10/2019] [Accepted: 05/12/2019] [Indexed: 11/17/2022] Open
Abstract
The agricultural industry has made a tremendous contribution to the foundations of civilization. Basic essentials such as food, beverages, clothes and domestic materials are enriched by the agricultural industry. However, the traditional method in agriculture cultivation is labor-intensive and inadequate to meet the accelerating nature of human demands. This scenario raises the need to explore state-of-the-art crop cultivation and harvesting technologies. In this regard, optics and photonics technologies have proven to be effective solutions. This paper aims to present a comprehensive review of three photonic techniques, namely imaging, spectroscopy and spectral imaging, in a comparative manner for agriculture applications. Essentially, the spectral imaging technique is a robust solution which combines the benefits of both imaging and spectroscopy but faces the risk of underutilization. This review also comprehends the practicality of all three techniques by presenting existing examples in agricultural applications. Furthermore, the potential of these techniques is reviewed and critiqued by looking into agricultural activities involving palm oil, rubber, and agro-food crops. All the possible issues and challenges in implementing the photonic techniques in agriculture are given prominence with a few selective recommendations. The highlighted insights in this review will hopefully lead to an increased effort in the development of photonics applications for the future agricultural industry.
Collapse
Affiliation(s)
- Tan Jin Yeong
- Institute of Power Engineering, College of Engineering, Universiti Tenaga Nasional, Kajang 43000, Selangor, Malaysia.
| | - Ker Pin Jern
- Institute of Power Engineering, College of Engineering, Universiti Tenaga Nasional, Kajang 43000, Selangor, Malaysia.
| | - Lau Kuen Yao
- Institute of Power Engineering, College of Engineering, Universiti Tenaga Nasional, Kajang 43000, Selangor, Malaysia.
| | - M A Hannan
- Institute of Power Engineering, College of Engineering, Universiti Tenaga Nasional, Kajang 43000, Selangor, Malaysia.
| | - Shirley Tang Gee Hoon
- Microbiology Unit, Department of Pre-clinical, International Medical School, Management and Science University, University Drive, Off Persiaran Olahraga, Seksyen 13, Shah Alam 40100, Selangor, Malaysia.
| |
Collapse
|
9
|
Fluorescence Hyperspectral Imaging of Oil Samples and Its Quantitative Applications in Component Analysis and Thickness Estimation. SENSORS 2018; 18:s18124415. [PMID: 30551646 PMCID: PMC6308509 DOI: 10.3390/s18124415] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Revised: 12/08/2018] [Accepted: 12/08/2018] [Indexed: 12/16/2022]
Abstract
The fast response and analysis of oil spill accidents is important but remains challenging. Here, a compact fluorescence hyperspectral system based on a grating-prism structure able to perform component analysis of oil as well as make a quantitative estimation of oil film thickness is developed. The spectrometer spectral range is 366⁻814 nm with a spectral resolution of 1 nm. The feasibility of the spectrometer system is demonstrated by determining the composition of three types of crude oil and various mixtures of them. The relationship between the oil film thickness and the fluorescent hyperspectral intensity is furthermore investigated and found to be linear, which demonstrates the feasibility of using the fluorescence data to quantitatively measure oil film thickness. Capable of oil identification, distribution analysis, and oil film thickness detection, the fluorescence hyperspectral imaging system presented is promising for use during oil spill accidents by mounting it on, e.g., an unmanned aerial vehicle.
Collapse
|