1
|
Choi S, Woo SH, Park I, Lee S, Yeo KI, Lee SH, Lee SY, Yang S, Lee G, Chang WJ, Bashir R, Kim YS, Lee SW. Cellular subpopulations identified using an ensemble average of multiple dielectrophoresis measurements. Comput Biol Med 2024; 170:108011. [PMID: 38271838 DOI: 10.1016/j.compbiomed.2024.108011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 01/11/2024] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
While the average value measurement approach can successfully analyze and predict the general behavior and biophysical properties of an isogenic cell population, it fails when significant differences among individual cells are generated in the population by intracellular changes such as the cell cycle, or different cellular responses to certain stimuli. Detecting such single-cell differences in a cell population has remained elusive. Here, we describe an easy-to-implement and generalizable platform that measures the dielectrophoretic cross-over frequency of individual cells by decreasing measurement noise with a stochastic method and computing ensemble average statistics. This platform enables multiple, real-time, label-free detection of individual cells with significant dielectric variations over time within an isogenic cell population. Using a stochastic method in combination with the platform, we distinguished cell subpopulations from a mixture of drug-untreated and -treated isogenic cells. Furthermore, we demonstrate that our platform can identify drug-treated isogenic cells with different recovery rates.
Collapse
Affiliation(s)
- Seungyeop Choi
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea; School of Biomedical Engineering, Korea University, Seoul, 02481, Republic of Korea; BK21 Four Institute of Precision Public Health, Korea University, Seoul, 02841, Republic of Korea
| | - Sung-Hun Woo
- Department of Biomedical Laboratory Science, Yonsei University, Wonju, 26493, Republic of Korea
| | - Insu Park
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Department of Biomedical Engineering, Konyang University, Daejeon, 35365, Republic of Korea
| | - Sena Lee
- Department of Precision Medicine, Wonju College of Medicine, Yonsei University, Wonju, 26426, Republic of Korea
| | - Kang In Yeo
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea
| | - Sang Hyun Lee
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea
| | - Sei Young Lee
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea; Department of Medical Informatics and Biostatistics, Graduate School, Yonsei University, Wonju, 26426, Republic of Korea
| | - Sejung Yang
- Department of Precision Medicine, Wonju College of Medicine, Yonsei University, Wonju, 26426, Republic of Korea
| | - Gyudo Lee
- Department of Biotechnology and Bioinformatics, Korea University, Sejong, 30019, Republic of Korea; Interdisciplinary Graduate Program for Artificial Intelligence Smart Convergence Technology, Korea University, Sejong, 30019, Republic of Korea
| | - Woo-Jin Chang
- Mechanical Engineering Department, University of Wisconsin-Milwaukee, Milwaukee, WI, 53211, USA
| | - Rashid Bashir
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Yoon Suk Kim
- Department of Biomedical Laboratory Science, Yonsei University, Wonju, 26493, Republic of Korea.
| | - Sang Woo Lee
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea.
| |
Collapse
|
2
|
Choi S, Park I, Lee SH, Yeo KI, Min G, Woo SH, Kim YS, Lee SY, Lee SW. On-Chip Single-Cell Bioelectrical Analysis for Identification of Cell Electrical Phenotyping in Response to Sequential Electric Signal Modulation. BIOSENSORS 2022; 12:1037. [PMID: 36421154 PMCID: PMC9688586 DOI: 10.3390/bios12111037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 11/12/2022] [Accepted: 11/12/2022] [Indexed: 06/16/2023]
Abstract
In recent years, an interesting biomarker called membrane breakdown voltage has been examined using artificial planar lipid bilayers. Even though they have great potential to identify cell electrical phenotyping for distinguishing similar cell lines or cells under different physiological conditions, the biomarker has not been evaluated in the context of living cell electrical phenotyping. Herein, we present a single-cell analysis platform to continuously measure the electric response in a large number of cells in parallel using electric frequency and voltage variables. Using this platform, we measured the direction of cell displacement and transparent cell image alteration as electric polarization of the cell responds to signal modulation, extracting the dielectrophoretic crossover frequency and membrane breakdown voltage for each cell, and utilizing the measurement results in the same spatiotemporal environment. We developed paired parameters using the dielectrophoretic crossover frequency and membrane breakdown voltage for each cell and evaluated the paired parameter efficiency concerning the identification of two different breast cancer cells and cell drug response. Moreover, we showed that the platform was able to identify cell electrical phenotyping, which was generated by subtle changes in cholesterol depletion-induced cell membrane integrity disruption when the paired parameter was used. Our platform introduced in this paper is extremely useful for facilitating more accurate and efficient evaluation of cell electrical phenotyping in a variety of applications, such as cell biology and drug discovery.
Collapse
Affiliation(s)
- Seungyeop Choi
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Insu Park
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Biomedical Engineering, Konyang University, Daejeon 35365, Republic of Korea
| | - Sang Hyun Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Kang In Yeo
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Gyeongjun Min
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Sung-Hun Woo
- Department of Biomedical Laboratory Science, Yonsei University, Wonju 26493, Republic of Korea
| | - Yoon Suk Kim
- Department of Biomedical Laboratory Science, Yonsei University, Wonju 26493, Republic of Korea
| | - Sei Young Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Sang Woo Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| |
Collapse
|
3
|
Yeo KI, Park I, Lee SH, Lee SY, Chang WJ, Bashir R, Choi S, Lee SW. Ultra-sensitive dielectrophoretic surface charge multiplex detection inside a micro-dielectrophoretic device. Biosens Bioelectron 2022; 210:114235. [PMID: 35483112 DOI: 10.1016/j.bios.2022.114235] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 03/22/2022] [Accepted: 03/28/2022] [Indexed: 12/23/2022]
Abstract
Label-free dielectrophoretic force-based surface charge detection has shown great potential for highly sensitive and selective sensing of metal ions and small biomolecules. However, this method suffers from a complex calibration process and measurement signal interference in simultaneous multi-analyte detection, thus creating difficulties in multiplex detection. We have developed a method to overcome these issues based on the optical discrimination of the dielectrophoretic behaviors of multiple microparticle probes considering the surface charge difference before and after self-assembling conjugation. In this report, we demonstrate and characterize this dielectrophoretic force-based surface charge detection method with particle probes functionalized by various biomolecules. This technique achieved an attomolar limit of detection (LOD) for Hg2+ in distilled water and a femtomolar LOD in drinking water using DNA aptamer-functionalized particle probes. More importantly, using two different DNA aptamer-functionalized particle probes for Hg2+ and Ag+, label-free dielectrophoretic multiplex detection of these species in drinking water with a femtomolar and a nanomolar LOD was achieved for the first time.
Collapse
Affiliation(s)
- Kang In Yeo
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea
| | - Insu Park
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Sang Hyun Lee
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea
| | - Sei Young Lee
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea
| | - Woo-Jin Chang
- Mechanical Engineering Department, University of Wisconsin-Milwaukee, Milwaukee, WI, 53211, USA
| | - Rashid Bashir
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Seungyeop Choi
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea.
| | - Sang Woo Lee
- Department of Biomedical Engineering, Yonsei University, Wonju, 26493, Republic of Korea.
| |
Collapse
|
4
|
Rahman MRU, Kwak TJ, Woehl JC, Chang WJ. Effect of geometry on dielectrophoretic trap stiffness in microparticle trapping. Biomed Microdevices 2021; 23:33. [PMID: 34185161 DOI: 10.1007/s10544-021-00570-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/11/2021] [Indexed: 10/21/2022]
Abstract
Dielectrophoresis, an electrokinetic technique, can be used for contactless manipulation of micro- and nano-size particles suspended in a fluid. We present a 3-D microfluidic DEP device with an orthogonal electrode configuration that uses negative dielectrophoresis to trap spherical polystyrene micro-particles. Traps with three different basic geometric shapes, i.e. triangular, square, and circular, and a fixed trap area of around 900 μm2 were investigated to determine the effect of trap shape on dynamics and strength of particle trapping. Effects of trap geometry were quantitatively investigated by means of trap stiffness, with applied electric potentials from 6 VP-P to 10 VP-P at 1 MHz. Analyzing the trap stiffness with a trapped 4.42 μm spherical particle showed that the triangular trap is the strongest, while the square shape trap is the weakest. The trap stiffness grew more than eight times in triangular traps and six times in both square and circular traps when the potential of the applied electric field was increased from 6 VP-P to 10 VP-P at 1 MHz. With the maximum applied potential, i.e. 10 VP-P at 1 MHz, the stiffness of the triangular trap was 60% and 26% stronger than the square and circular trap, respectively. A finite element model of the microfluidic DEP device was developed to numerically compute the DEP force for these trap shapes. The findings from the numerical computation demonstrate good agreement with the experimental analysis. The analysis of three different trap shapes provides important insights to predict trapping location, strength of the trapping zone, and optimized geometry for high throughput particle trapping.
Collapse
Affiliation(s)
| | - Tae Joon Kwak
- Center for Systems Biology, Massachusetts General Hospital, Boston, MA, 02114, USA
| | - Jörg C Woehl
- Department of Chemistry and Biochemistry, University of Wisconsin-Milwaukee, Milwaukee, WI, 53211, USA
| | - Woo-Jin Chang
- Department of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, 53211, USA. .,School of Freshwater Sciences, University of Wisconsin-Milwaukee, Milwaukee, WI, 53204, USA.
| |
Collapse
|
5
|
Rahman MRU, Kwak TJ, Woehl JC, Chang WJ. Quantitative analysis of the three-dimensional trap stiffness of a dielectrophoretic corral trap. Electrophoresis 2021; 42:644-655. [PMID: 33340119 DOI: 10.1002/elps.202000222] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 12/07/2020] [Accepted: 12/14/2020] [Indexed: 11/08/2022]
Abstract
Dielectrophoresis is a robust approach for the manipulation and separation of (bio)particles using microfluidic platforms. We developed a dielectrophoretic corral trap in a microfluidic device that utilizes negative dielectrophoresis to capture single spherical polystyrene particles. Circular-shaped micron-size traps were employed inside the device and the three-dimensional trap stiffness (restoring trapping force from equilibrium trapping location) was analyzed using 4.42 μm particles and 1 MHz of an alternating electric field from 6 VP-P to 10 VP-P . The trap stiffness increased exponentially in the x- and y-direction, and linearly in the z-direction. Image analysis of the trapped particle movements revealed that the trap stiffness is increased 608.4, 539.3, and 79.7% by increasing the voltage from 6 VP-P to 10 VP-P in the x-, y-, and z-direction, respectively. The trap stiffness calculated from a finite element simulation of the device confirmed the experimental results. This analysis provides important insights to predict the trapping location, strength of the trapping, and optimum geometry for single particle trapping and its applications such as single-molecule analysis and drug discovery.
Collapse
Affiliation(s)
| | - Tae Joon Kwak
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA
| | - Jörg C Woehl
- Department of Chemistry and Biochemistry, University of Wisconsin-Milwaukee, Milwaukee, WI, USA
| | - Woo-Jin Chang
- Department of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, USA.,School of Freshwater Sciences, University of Wisconsin-Milwaukee, Milwaukee, WI, USA
| |
Collapse
|
6
|
Ramirez-Murillo CJ, de Los Santos-Ramirez JM, Perez-Gonzalez VH. Toward low-voltage dielectrophoresis-based microfluidic systems: A review. Electrophoresis 2020; 42:565-587. [PMID: 33166414 DOI: 10.1002/elps.202000213] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 10/27/2020] [Accepted: 11/02/2020] [Indexed: 12/13/2022]
Abstract
Dielectrophoretically driven microfluidic devices have demonstrated great applicability in biomedical engineering, diagnostic medicine, and biological research. One of the potential fields of application for this technology is in point-of-care (POC) devices, ideally allowing for portable, fully integrated, easy to use, low-cost diagnostic platforms. Two main approaches exist to induce dielectrophoresis (DEP) on suspended particles, that is, electrode-based DEP and insulator-based DEP, each featuring different advantages and disadvantages. However, a shared concern lies in the input voltage used to generate the electric field necessary for DEP to take place. Therefore, input voltage can determine portability of a microfluidic device. This review outlines the recent advances in reducing stimulation voltage requirements in DEP-driven microfluidics.
Collapse
|
7
|
Choi S, Lee H, Lee S, Park I, Kim YS, Key J, Lee SY, Yang S, Lee SW. A novel automatic segmentation and tracking method to measure cellular dielectrophoretic mobility from individual cell trajectories for high throughput assay. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 195:105662. [PMID: 32712504 DOI: 10.1016/j.cmpb.2020.105662] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Accepted: 07/09/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE The dielectrophoresis (DEP) technique is increasingly being recognised as a potentially valuable tool for non-contact manipulation of numerous cells as well as for biological single cell analysis with non-invasive characterisation of a cell's electrical properties. Several studies have attempted to track multiple cells to characterise their cellular DEP mobility. However, they encountered difficulties in simultaneously tracking the movement of a large number of individual cells in a bright-field image sequence because of interference from the background electrode pattern. Consequently, this present study aims to develop an automatic system for imaging-based characterisation of cellular DEP mobility, which enables the simultaneous tracking of several hundred of cells inside a microfluidic device. METHODS The proposed method for segmentation and tracking of cells consists of two main stages: pre-processing and particle centre localisation. In the pre-processing stage, background subtraction and contrast enhancement were performed to distinguish the cell region from the background image. In the particle centre localisation stage, the unmarked cell was automatically detected via graph-cut algorithm-based K-means clustering. RESULTS Our algorithm enabled segmentation and tracking of numerous Michigan Cancer Foundation-7 (MCF-7) cell trajectories while the DEP force was oscillated between positive and negative. The cell tracking accuracy and cell count capability was at least 90% of the total number of cells with the newly developed algorithm. In addition, the cross-over frequency was measured by analysing the segmented and tracked trajectory data of the cellular movements caused by the positive and negative DEP force. The measured cross-over frequency was compared with previous results. The multi-cellular movements investigation based on the measured cross-over frequency was repeated until the viability of cells was unchanged in the same environment as in a microfluidic device. The results were statistically consistent, indicating that the developed algorithm was reliable for the investigation of DEP cellular mobility. CONCLUSION This study developed a powerful platform to simultaneously measure the DEP-induced trajectories of numerous cells, and to investigate in a robust, efficient, and accurate manner the DEP properties at both the single cell and cell ensemble level.
Collapse
Affiliation(s)
- Seungyeop Choi
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Hyunwoo Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Sena Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Insu Park
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois, Urbana, IL, USA
| | - Yoon Suk Kim
- Department of Biomedical Laboratory Science, Yonsei University, Wonju 26493, Republic of Korea
| | - Jaehong Key
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Sei Young Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea
| | - Sejung Yang
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
| | - Sang Woo Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
| |
Collapse
|
8
|
Park I, Lim JW, Kim SH, Choi S, Ko KH, Son MG, Chang WJ, Yoon YR, Yang S, Key J, Kim YS, Eom K, Bashir R, Lee SY, Lee SW. Variable Membrane Dielectric Polarization Characteristic in Individual Live Cells. J Phys Chem Lett 2020; 11:7197-7203. [PMID: 32813536 DOI: 10.1021/acs.jpclett.0c01427] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Investigation of the dielectric properties of cell membranes plays an important role in understanding the biological activities that sustain cellular life and realize cellular functionalities. Herein, the variable dielectric polarization characteristics of cell membranes are reported. In controlling the dielectric polarization of a cell using dielectrophoresis force spectroscopy, different cellular crossover frequencies were observed by modulating both the direction and sweep rate of the frequency. The crossover frequencies were used for the extraction of the variable capacitance, which is involved in the dielectric polarization across the cell membranes. In addition, this variable phenomenon was investigated by examining cells whose membranes were cholesterol-depleted with methyl-β-cyclodextrin, which verified a strong correlation between the variable dielectric polarization characteristics and membrane composition changes. This study presented the dielectric polarization properties in live cells' membranes that can be modified by the regulation of external stimuli and provided a powerful platform to explore cellular membrane dielectric polarization.
Collapse
Affiliation(s)
- Insu Park
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Jong Won Lim
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Sung Hoon Kim
- Department of Biomedical Laboratory Science, Yonsei University, Wonju 26493, Korea
- Department of Biomedical Laboratory Science, Korea Nazarene University, Chungnam 31172, Korea
| | - Seungyeop Choi
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Kwan Hwi Ko
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Myung Gu Son
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Woo-Jin Chang
- Mechanical Engineering Department, University of Wisconsin-Milwaukee, Milwaukee, Wisconsin 53211, United States
| | - Young Ro Yoon
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Sejung Yang
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Jaehong Key
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Yoon Suk Kim
- Department of Biomedical Laboratory Science, Yonsei University, Wonju 26493, Korea
| | - Kilho Eom
- Biomechanics Laboratory, College of Sport Science, Sungkyunkwan University, Suwon 16419, Korea
| | - Rashid Bashir
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Carle Illinois College of Medicine, Urbana, Illinois 61801, United States
- Mayo-Illinois Alliance for Technology Based Healthcare, Urbana, Illinois 61801, United States
| | - Sei Young Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| | - Sang Woo Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea
| |
Collapse
|
9
|
Abstract
Cancer drug resistance mechanisms such as tumor heterogeneity and adaptable feedback loops are prevalent issues facing cancer therapy development. Drug resistance can be unique to a cancer type and, most importantly, to each individual cancer patient. Consequently, testing different dosages and therapeutics directly on each individual patient sample (i.e., tumor and cancer cells) has compelling advantages compared to large scale in vitro drug testing and is a step toward personalized drug selection and effective treatment development. Recently, microfluidic-based chemo-sensitivity assays on patient biopsies have been proposed. Despite their novelty, these platforms usually rely on optical labels, optical equipment, or complex microfabricated channel geometries and structures. In this work, we proposed a novel lab on a chip platform capable of real-time and continuous screening of drug efficacy on (cancer) cell subpopulations without the need of labels or bulky readout optical equipment. In this platform, several label-free and rapid techniques have been implemented for the precise capturing of cells of interest in parallel with the real-time measurement and characterization of the effectiveness of candidate therapeutic agents. To demonstrate the utility of the platform, the effect of an apoptotic inducer, topoisomerase I inhibitor, 7-ethyl-10-hydrocamptothecin (SN38) on human colorectal carcinoma cancer cells (HCT 116) was used as a study model. Additionally, electrical results were optically verified to examine the continuous measurements of the biological mechanisms, specifically, apoptosis and necrosis, during therapeutic agent characterizations. The proposed device is a versatile platform which can also be easily redesigned for the automated and arrayed analysis of cell-drug interaction down to the single cell level. Our platform is another step toward enabling the personalized screening of drug efficacy on individual patients' samples that potentially leads to a better understanding of drug resistance and the optimization of patients' treatments.
Collapse
Affiliation(s)
- Vanessa Velasco
- Biochemistry Department , Stanford University , Palo Alto , California 94305 , United States
| | - Kushal Joshi
- Department of Biomedical Engineering , University of California Irvine , Irvine , California 92617 , United States
| | - Jiamin Chen
- Department of Medicine, Division of Oncology , Stanford University School of Medicine , Palo Alto , California 94305 , United States
| | - Rahim Esfandyarpour
- Department of Electrical Engineering , University of California Irvine , Irvine , California 92617 , United States.,Department of Biomedical Engineering , University of California Irvine , Irvine , California 92617 , United States.,Henry Samueli School of Engineering , University of California Irvine , Irvine , California 92617 , United States
| |
Collapse
|