1
|
Jochumsen M, Lavesen ER, Griem AB, Falkenberg-Andersen C, Jensen SKG. The Effect of Caffeine on Movement-Related Cortical Potential Morphology and Detection. SENSORS (BASEL, SWITZERLAND) 2024; 24:4030. [PMID: 38931814 PMCID: PMC11209428 DOI: 10.3390/s24124030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Revised: 06/15/2024] [Accepted: 06/18/2024] [Indexed: 06/28/2024]
Abstract
Movement-related cortical potential (MRCP) is observed in EEG recordings prior to a voluntary movement. It has been used for e.g., quantifying motor learning and for brain-computer interfacing (BCIs). The MRCP amplitude is affected by various factors, but the effect of caffeine is underexplored. The aim of this study was to investigate if a cup of coffee with 85 mg caffeine modulated the MRCP amplitude and the classification of MRCPs versus idle activity, which estimates BCI performance. Twenty-six healthy participants performed 2 × 100 ankle dorsiflexion separated by a 10-min break before a cup of coffee was consumed, followed by another 100 movements. EEG was recorded during the movements and divided into epochs, which were averaged to extract three average MRCPs that were compared. Also, idle activity epochs were extracted. Features were extracted from the epochs and classified using random forest analysis. The MRCP amplitude did not change after consuming caffeine. There was a slight increase of two percentage points in the classification accuracy after consuming caffeine. In conclusion, a cup of coffee with 85 mg caffeine does not affect the MRCP amplitude, and improves MRCP-based BCI performance slightly. The findings suggest that drinking coffee is only a minor confounder in MRCP-related studies.
Collapse
Affiliation(s)
- Mads Jochumsen
- Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark
| | | | | | | | | |
Collapse
|
2
|
Alder G, Taylor D, Rashid U, Olsen S, Brooks T, Terry G, Niazi IK, Signal N. A Brain Computer Interface Neuromodulatory Device for Stroke Rehabilitation: Iterative User-Centered Design Approach. JMIR Rehabil Assist Technol 2023; 10:e49702. [PMID: 38079202 PMCID: PMC10750233 DOI: 10.2196/49702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 09/03/2023] [Accepted: 09/27/2023] [Indexed: 12/28/2023] Open
Abstract
BACKGROUND Rehabilitation technologies for people with stroke are rapidly evolving. These technologies have the potential to support higher volumes of rehabilitation to improve outcomes for people with stroke. Despite growing evidence of their efficacy, there is a lack of uptake and sustained use in stroke rehabilitation and a call for user-centered design approaches during technology design and development. This study focuses on a novel rehabilitation technology called exciteBCI, a complex neuromodulatory wearable technology in the prototype stage that augments locomotor rehabilitation for people with stroke. The exciteBCI consists of a brain computer interface, a muscle electrical stimulator, and a mobile app. OBJECTIVE This study presents the evaluation phase of an iterative user-centered design approach supported by a qualitative descriptive methodology that sought to (1) explore users' perspectives and experiences of exciteBCI and how well it fits with rehabilitation, and (2) facilitate modifications to exciteBCI design features. METHODS The iterative usability evaluation of exciteBCI was conducted in 2 phases. Phase 1 consisted of 3 sprint cycles consisting of single usability sessions with people with stroke (n=4) and physiotherapists (n=4). During their interactions with exciteBCI, participants used a "think-aloud" approach, followed by a semistructured interview. At the end of each sprint cycle, device requirements were gathered and the device was modified in preparation for the next cycle. Phase 2 focused on a "near-live" approach in which 2 people with stroke and 1 physiotherapist participated in a 3-week program of rehabilitation augmented by exciteBCI (n=3). Participants completed a semistructured interview at the end of the program. Data were analyzed from both phases using conventional content analysis. RESULTS Overall, participants perceived and experienced exciteBCI positively, while providing guidance for iterative changes. Five interrelated themes were identified from the data: (1) "This is rehab" illustrated that participants viewed exciteBCI as having a good fit with rehabilitation practice; (2) "Getting the most out of rehab" highlighted that exciteBCI was perceived as a means to enhance rehabilitation through increased engagement and challenge; (3) "It is a tool not a therapist," revealed views that the technology could either enhance or disrupt the therapeutic relationship; and (4) "Weighing up the benefits versus the burden" and (5) "Don't make me look different" emphasized important design considerations related to device set-up, use, and social acceptability. CONCLUSIONS This study offers several important findings that can inform the design and implementation of rehabilitation technologies. These include (1) the design of rehabilitation technology should support the therapeutic relationship between the patient and therapist, (2) social acceptability is a design priority in rehabilitation technology but its importance varies depending on the use context, and (3) there is value in using design research methods that support understanding usability in the context of sustained use.
Collapse
Affiliation(s)
- Gemma Alder
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| | - Denise Taylor
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| | - Usman Rashid
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| | - Sharon Olsen
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| | - Thonia Brooks
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| | - Gareth Terry
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| | - Imran Khan Niazi
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
- Centre for Chiropractic Research, New Zealand College of Chiropractic, Auckland, New Zealand
- Sensory Motor Integration, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Nada Signal
- Rehabilitation Innovation Centre, Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| |
Collapse
|
3
|
Belkacem AN, Jamil N, Khalid S, Alnajjar F. On closed-loop brain stimulation systems for improving the quality of life of patients with neurological disorders. Front Hum Neurosci 2023; 17:1085173. [PMID: 37033911 PMCID: PMC10076878 DOI: 10.3389/fnhum.2023.1085173] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 03/06/2023] [Indexed: 04/11/2023] Open
Abstract
Emerging brain technologies have significantly transformed human life in recent decades. For instance, the closed-loop brain-computer interface (BCI) is an advanced software-hardware system that interprets electrical signals from neurons, allowing communication with and control of the environment. The system then transmits these signals as controlled commands and provides feedback to the brain to execute specific tasks. This paper analyzes and presents the latest research on closed-loop BCI that utilizes electric/magnetic stimulation, optogenetic, and sonogenetic techniques. These techniques have demonstrated great potential in improving the quality of life for patients suffering from neurodegenerative or psychiatric diseases. We provide a comprehensive and systematic review of research on the modalities of closed-loop BCI in recent decades. To achieve this, the authors used a set of defined criteria to shortlist studies from well-known research databases into categories of brain stimulation techniques. These categories include deep brain stimulation, transcranial magnetic stimulation, transcranial direct-current stimulation, transcranial alternating-current stimulation, and optogenetics. These techniques have been useful in treating a wide range of disorders, such as Alzheimer's and Parkinson's disease, dementia, and depression. In total, 76 studies were shortlisted and analyzed to illustrate how closed-loop BCI can considerably improve, enhance, and restore specific brain functions. The analysis revealed that literature in the area has not adequately covered closed-loop BCI in the context of cognitive neural prosthetics and implanted neural devices. However, the authors demonstrate that the applications of closed-loop BCI are highly beneficial, and the technology is continually evolving to improve the lives of individuals with various ailments, including those with sensory-motor issues or cognitive deficiencies. By utilizing emerging techniques of stimulation, closed-loop BCI can safely improve patients' cognitive and affective skills, resulting in better healthcare outcomes.
Collapse
Affiliation(s)
- Abdelkader Nasreddine Belkacem
- Department of Computer and Network Engineering, College of Information Technology, UAE University, Al-Ain, United Arab Emirates
- *Correspondence: Abdelkader Nasreddine Belkacem
| | - Nuraini Jamil
- Department of Computer Science and Software Engineering, College of Information Technology, UAE University, Al-Ain, United Arab Emirates
| | - Sumayya Khalid
- Department of Computer Science and Software Engineering, College of Information Technology, UAE University, Al-Ain, United Arab Emirates
| | - Fady Alnajjar
- Department of Computer Science and Software Engineering, College of Information Technology, UAE University, Al-Ain, United Arab Emirates
- Center for Brain Science, RIKEN, Saitama, Japan
- Fady Alnajjar
| |
Collapse
|
4
|
Jochumsen M, Hougaard BI, Kristensen MS, Knoche H. Implementing Performance Accommodation Mechanisms in Online BCI for Stroke Rehabilitation: A Study on Perceived Control and Frustration. SENSORS (BASEL, SWITZERLAND) 2022; 22:9051. [PMID: 36501753 PMCID: PMC9738420 DOI: 10.3390/s22239051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 11/16/2022] [Accepted: 11/18/2022] [Indexed: 06/17/2023]
Abstract
Brain-computer interfaces (BCIs) are successfully used for stroke rehabilitation, but the training is repetitive and patients can lose the motivation to train. Moreover, controlling the BCI may be difficult, which causes frustration and leads to even worse control. Patients might not adhere to the regimen due to frustration and lack of motivation/engagement. The aim of this study was to implement three performance accommodation mechanisms (PAMs) in an online motor imagery-based BCI to aid people and evaluate their perceived control and frustration. Nineteen healthy participants controlled a fishing game with a BCI in four conditions: (1) no help, (2) augmented success (augmented successful BCI-attempt), (3) mitigated failure (turn unsuccessful BCI-attempt into neutral output), and (4) override input (turn unsuccessful BCI-attempt into successful output). Each condition was followed-up and assessed with Likert-scale questionnaires and a post-experiment interview. Perceived control and frustration were best predicted by the amount of positive feedback the participant received. PAM-help increased perceived control for poor BCI-users but decreased it for good BCI-users. The input override PAM frustrated the users the most, and they differed in how they wanted to be helped. By using PAMs, developers have more freedom to create engaging stroke rehabilitation games.
Collapse
Affiliation(s)
- Mads Jochumsen
- Department of Health Science and Technology, Aalborg University, 9000 Aalborg, Denmark
| | - Bastian Ilsø Hougaard
- Department of Architecture, Design and Media Technology, Aalborg University, 9000 Aalborg, Denmark
| | - Mathias Sand Kristensen
- Department of Architecture, Design and Media Technology, Aalborg University, 9000 Aalborg, Denmark
| | - Hendrik Knoche
- Department of Architecture, Design and Media Technology, Aalborg University, 9000 Aalborg, Denmark
| |
Collapse
|
5
|
Niazi IK, Navid MS, Rashid U, Amjad I, Olsen S, Haavik H, Alder G, Kumari N, Signal N, Taylor D, Farina D, Jochumsen M. Associative cued asynchronous BCI induces cortical plasticity in stroke patients. Ann Clin Transl Neurol 2022; 9:722-733. [PMID: 35488791 PMCID: PMC9082379 DOI: 10.1002/acn3.51551] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 02/14/2022] [Accepted: 03/12/2022] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVE We propose a novel cue-based asynchronous brain-computer interface(BCI) for neuromodulation via the pairing of endogenous motor cortical activity with the activation of somatosensory pathways. METHODS The proposed BCI detects the intention to move from single-trial EEG signals in real time, but, contrary to classic asynchronous-BCI systems, the detection occurs only during time intervals when the patient is cued to move. This cue-based asynchronous-BCI was compared with two traditional BCI modes (asynchronous-BCI and offline synchronous-BCI) and a control intervention in chronic stroke patients. The patients performed ankle dorsiflexion movements of the paretic limb in each intervention while their brain signals were recorded. BCI interventions decoded the movement attempt and activated afferent pathways via electrical stimulation. Corticomotor excitability was assessed using motor-evoked potentials in the tibialis-anterior muscle induced by transcranial magnetic stimulation before, immediately after, and 30 min after the intervention. RESULTS The proposed cue-based asynchronous-BCI had significantly fewer false positives/min and false positives/true positives (%) as compared to the previously developed asynchronous-BCI. Linear-mixed-models showed that motor-evoked potential amplitudes increased following all BCI modes immediately after the intervention compared to the control condition (p <0.05). The proposed cue-based asynchronous-BCI resulted in the largest relative increase in peak-to-peak motor-evoked potential amplitudes(141% ± 33%) among all interventions and sustained it for 30 min(111% ± 33%). INTERPRETATION These findings prove the high performance of a newly proposed cue-based asynchronous-BCI intervention. In this paradigm, individuals receive precise instructions (cue) to promote engagement, while the timing of brain activity is accurately detected to establish a precise association with the delivery of sensory input for plasticity induction.
Collapse
Affiliation(s)
- Imran Khan Niazi
- Health and Rehabilitation Research Institute and BioDesign LabAuckland University of TechnologyAucklandNew Zealand
- SMI, Department of Health Science and TechnologyAalborg UniversityAalborgDenmark
- Centre for Chiropractic ResearchNew Zealand College of ChiropracticAucklandNew Zealand
| | - Muhammad Samran Navid
- Centre for Chiropractic ResearchNew Zealand College of ChiropracticAucklandNew Zealand
| | - Usman Rashid
- Health and Rehabilitation Research Institute and BioDesign LabAuckland University of TechnologyAucklandNew Zealand
| | - Imran Amjad
- Centre for Chiropractic ResearchNew Zealand College of ChiropracticAucklandNew Zealand
- Riphah International UniversityIslamabadPakistan
| | - Sharon Olsen
- Health and Rehabilitation Research Institute and BioDesign LabAuckland University of TechnologyAucklandNew Zealand
| | - Heidi Haavik
- Centre for Chiropractic ResearchNew Zealand College of ChiropracticAucklandNew Zealand
| | - Gemma Alder
- Health and Rehabilitation Research Institute and BioDesign LabAuckland University of TechnologyAucklandNew Zealand
| | - Nitika Kumari
- Health and Rehabilitation Research Institute and BioDesign LabAuckland University of TechnologyAucklandNew Zealand
- Centre for Chiropractic ResearchNew Zealand College of ChiropracticAucklandNew Zealand
| | - Nada Signal
- Health and Rehabilitation Research Institute and BioDesign LabAuckland University of TechnologyAucklandNew Zealand
| | - Denise Taylor
- Health and Rehabilitation Research Institute and BioDesign LabAuckland University of TechnologyAucklandNew Zealand
| | - Dario Farina
- Department of BioengineeringImperial College LondonLondonUK
| | - Mads Jochumsen
- SMI, Department of Health Science and TechnologyAalborg UniversityAalborgDenmark
| |
Collapse
|
6
|
Alder G, Signal N, Vandal AC, Olsen S, Jochumsen M, Niazi IK, Taylor D. Investigating the Intervention Parameters of Endogenous Paired Associative Stimulation (ePAS). Brain Sci 2021; 11:brainsci11020224. [PMID: 33673171 PMCID: PMC7918620 DOI: 10.3390/brainsci11020224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Revised: 01/20/2021] [Accepted: 02/04/2021] [Indexed: 11/16/2022] Open
Abstract
Advances in our understanding of neural plasticity have prompted the emergence of neuromodulatory interventions, which modulate corticomotor excitability (CME) and hold potential for accelerating stroke recovery. Endogenous paired associative stimulation (ePAS) involves the repeated pairing of a single pulse of peripheral electrical stimulation (PES) with endogenous movement-related cortical potentials (MRCPs), which are derived from electroencephalography. However, little is known about the optimal parameters for its delivery. A factorial design with repeated measures delivered four different versions of ePAS, in which PES intensities and movement type were manipulated. Linear mixed models were employed to assess interaction effects between PES intensity (suprathreshold (Hi) and motor threshold (Lo)) and movement type (Voluntary and Imagined) on CME. ePAS interventions significantly increased CME compared to control interventions, except in the case of Lo-Voluntary ePAS. There was an overall main effect for the Hi-Voluntary ePAS intervention immediately post-intervention (p = 0.002), with a sub-additive interaction effect at 30 min’ post-intervention (p = 0.042). Hi-Imagined and Lo-Imagined ePAS significantly increased CME for 30 min post-intervention (p = 0.038 and p = 0.043 respectively). The effects of the two PES intensities were not significantly different. CME was significantly greater after performing imagined movements, compared to voluntary movements, with motor threshold PES (Lo) 15 min post-intervention (p = 0.012). This study supports previous research investigating Lo-Imagined ePAS and extends those findings by illustrating that ePAS interventions that deliver suprathreshold intensities during voluntary or imagined movements (Hi-Voluntary and Hi-Imagined) also increase CME. Importantly, our findings indicate that stimulation intensity and movement type interact in ePAS interventions. Factorial designs are an efficient way to explore the effects of manipulating the parameters of neuromodulatory interventions. Further research is required to ensure that these parameters are appropriately refined to maximise intervention efficacy for people with stroke and to support translation into clinical practice.
Collapse
Affiliation(s)
- Gemma Alder
- Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland 0627, New Zealand; (N.S.); (S.O.); (I.K.N.); (D.T.)
- Correspondence:
| | - Nada Signal
- Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland 0627, New Zealand; (N.S.); (S.O.); (I.K.N.); (D.T.)
| | - Alain C. Vandal
- Department of Statistics, University of Auckland, Auckland 1142, New Zealand;
- Ko Awatea, Counties Manukau Health, Auckland 2025, New Zealand
| | - Sharon Olsen
- Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland 0627, New Zealand; (N.S.); (S.O.); (I.K.N.); (D.T.)
| | - Mads Jochumsen
- Department of Health Science and Technology, Aalborg University, 9000 Aalborg, Denmark;
| | - Imran Khan Niazi
- Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland 0627, New Zealand; (N.S.); (S.O.); (I.K.N.); (D.T.)
- Department of Health Science and Technology, Aalborg University, 9000 Aalborg, Denmark;
- Centre for Chiropractic Research, New Zealand College of Chiropractic, Auckland 1060, New Zealand
| | - Denise Taylor
- Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland 0627, New Zealand; (N.S.); (S.O.); (I.K.N.); (D.T.)
| |
Collapse
|
7
|
Induction of Neural Plasticity Using a Low-Cost Open Source Brain-Computer Interface and a 3D-Printed Wrist Exoskeleton. SENSORS 2021; 21:s21020572. [PMID: 33467420 PMCID: PMC7830618 DOI: 10.3390/s21020572] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/08/2021] [Accepted: 01/12/2021] [Indexed: 11/16/2022]
Abstract
Brain-computer interfaces (BCIs) have been proven to be useful for stroke rehabilitation, but there are a number of factors that impede the use of this technology in rehabilitation clinics and in home-use, the major factors including the usability and costs of the BCI system. The aims of this study were to develop a cheap 3D-printed wrist exoskeleton that can be controlled by a cheap open source BCI (OpenViBE), and to determine if training with such a setup could induce neural plasticity. Eleven healthy volunteers imagined wrist extensions, which were detected from single-trial electroencephalography (EEG), and in response to this, the wrist exoskeleton replicated the intended movement. Motor-evoked potentials (MEPs) elicited using transcranial magnetic stimulation were measured before, immediately after, and 30 min after BCI training with the exoskeleton. The BCI system had a true positive rate of 86 ± 12% with 1.20 ± 0.57 false detections per minute. Compared to the measurement before the BCI training, the MEPs increased by 35 ± 60% immediately after and 67 ± 60% 30 min after the BCI training. There was no association between the BCI performance and the induction of plasticity. In conclusion, it is possible to detect imaginary movements using an open-source BCI setup and control a cheap 3D-printed exoskeleton that when combined with the BCI can induce neural plasticity. These findings may promote the availability of BCI technology for rehabilitation clinics and home-use. However, the usability must be improved, and further tests are needed with stroke patients.
Collapse
|
8
|
The Effects of Spinal Manipulation on Motor Unit Behavior. Brain Sci 2021; 11:brainsci11010105. [PMID: 33466707 PMCID: PMC7828823 DOI: 10.3390/brainsci11010105] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/08/2021] [Accepted: 01/12/2021] [Indexed: 12/05/2022] Open
Abstract
Over recent years, a growing body of research has highlighted the neural plastic effects of spinal manipulation on the central nervous system. Recently, it has been shown that spinal manipulation improved outcomes, such as maximum voluntary force and limb joint position sense, reflecting improved sensorimotor integration and processing. This study aimed to further evaluate how spinal manipulation can alter neuromuscular activity. High density electromyography (HD sEMG) signals from the tibialis anterior were recorded and decomposed in order to study motor unit changes in 14 subjects following spinal manipulation or a passive movement control session in a crossover study design. Participants were asked to produce ankle dorsiflexion at two force levels, 5% and 10% of maximum voluntary contraction (MVC), following two different patterns of force production (“ramp” and “ramp and maintain”). A significant decrease in the conduction velocity (p = 0.01) was observed during the “ramp and maintain” condition at 5% MVC after spinal manipulation. A decrease in conduction velocity suggests that spinal manipulation alters motor unit recruitment patterns with an increased recruitment of lower threshold, lower twitch torque motor units.
Collapse
|
9
|
Khaliq Fard M, Fallah A, Maleki A. Neural decoding of continuous upper limb movements: a meta-analysis. Disabil Rehabil Assist Technol 2020; 17:731-737. [PMID: 33186068 DOI: 10.1080/17483107.2020.1842919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE EEG-based motion trajectory decoding makes a promising approach for neurotechnology which can be used for neural control of motion reconstruction and neurorehabilitation tools. However, the feasibility and validity of continuous motion decoding by non-invasive brain activity are not clear. The main aim of this study was to perform a meta-analysis across studies that examined the ability of EEG-based continuous motion decoding of upper limb movements. APPROACH Pearson's correlation coefficient (CC) was used to evaluate the model performance of the studies and considered as an effect size. To estimate the overall effect size of neural decoding of motion trajectory across studies, characteristics of included studies were addressed and the random effect model was applied to the heterogeneous studies which estimated overall effect size distribution. Furthermore, the significant difference between the two subgroups of imagined and executed movements was analysed. MAIN RESULTS The mean of the overall effect size was computed 0.46 across the nonhomogeneous studies. The results showed no significant difference between imagined and executed movements (Chi2=0.28, df = 1, p = 0.60). SIGNIFICANCE Meta-analysis results confirm that imagination like execution movements can be used for neural decoding of motion trajectory in neural motor control systems. Also, nonlinear compare with linear model statistically confirmed to be more beneficial for complex movements. Furthermore, a new approach of synergy-based motion decoding can be significantly effective to increase model performance and more research needs to evaluate this method for different levels of complexity of movements.IMPLICATIONS FOR REHABILITATIONNeural decoding methods base on EEG as a non-invasive brain activity, are more user friendly for neurorehabilitation than invasive methods that developing of it makes it more applicable for reconstructing activities of daily living.Neurotechnology for neural control of motion reconstruction, makes the rehabilitation tools to be more synchrony with human intentional movement that can be used to improve the brain neuroplastisity in stroke or other paralysed people.The feasibility and validity of imagined movements equal with executed movements show that amputee people also can benefit EEG-based motion decoding for controling rehabilitation tools just by imagination of their intentional movements.For neurorehabilitation tools, comparing the study outcomes illucidate that the approach of synergy-based motor control in brain activities concluded significantly high performance that highlighted the need it to more investigated in future research.
Collapse
Affiliation(s)
- Mahdie Khaliq Fard
- Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | - Ali Fallah
- Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | | |
Collapse
|
10
|
Carson RG, Buick AR. Neuromuscular electrical stimulation-promoted plasticity of the human brain. J Physiol 2019; 599:2375-2399. [PMID: 31495924 DOI: 10.1113/jp278298] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Accepted: 08/16/2019] [Indexed: 12/21/2022] Open
Abstract
The application of neuromuscular electrical stimulation (NMES) to paretic limbs has demonstrated utility for motor rehabilitation following brain injury. When NMES is delivered to a mixed peripheral nerve, typically both efferent and afferent fibres are recruited. Muscle contractions brought about by the excitation of motor neurons are often used to compensate for disability by assisting actions such as the formation of hand aperture, or by preventing others including foot drop. In this context, exogenous stimulation provides a direct substitute for endogenous neural drive. The goal of the present narrative review is to describe the means through which NMES may also promote sustained adaptations within central motor pathways, leading ultimately to increases in (intrinsic) functional capacity. There is an obvious practical motivation, in that detailed knowledge concerning the mechanisms of adaptation has the potential to inform neurorehabilitation practice. In addition, responses to NMES provide a means of studying CNS plasticity at a systems level in humans. We summarize the fundamental aspects of NMES, focusing on the forms that are employed most commonly in clinical and experimental practice. Specific attention is devoted to adjuvant techniques that further promote adaptive responses to NMES thereby offering the prospect of increased therapeutic potential. The emergent theme is that an association with centrally initiated neural activity, whether this is generated in the context of NMES triggered by efferent drive or via indirect methods such as mental imagery, may in some circumstances promote the physiological changes that can be induced through peripheral electrical stimulation.
Collapse
Affiliation(s)
- Richard G Carson
- Trinity College Institute of Neuroscience and School of Psychology, Trinity College Dublin, Dublin 2, Ireland.,School of Psychology, Queen's University Belfast, Belfast, BT7 1NN, UK.,School of Human Movement and Nutrition Sciences, University of Queensland, Brisbane, QLD 4072, Australia
| | - Alison R Buick
- School of Psychology, Queen's University Belfast, Belfast, BT7 1NN, UK
| |
Collapse
|
11
|
Jochumsen M, Navid MS, Rashid U, Haavik H, Niazi IK. EMG- Versus EEG-Triggered Electrical Stimulation for Inducing Corticospinal Plasticity. IEEE Trans Neural Syst Rehabil Eng 2019; 27:1901-1908. [PMID: 31380763 DOI: 10.1109/tnsre.2019.2932104] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Brain-computer interfaces have been proposed for stroke rehabilitation. Motor cortical activity derived from the electroencephalography (EEG) can trigger external devices that provide congruent sensory feedback. However, many stroke patients regain residual muscle (EMG: electromyography) control due to spontaneous recovery and rehabilitation; therefore, EEG may not be necessary as a control signal. In this paper, a direct comparison was made between the induction of corticospinal plasticity using either EEG- or EMG-controlled electrical nerve stimulation. Twenty healthy participants participated in two intervention sessions consisting of EEG- and EMG-controlled electrical stimulation. The sessions consisted of 50 pairings between foot dorsiflexion movements (decoded through either EEG or EMG) and electrical stimulation of the common peroneal nerve. Before, immediately after and 30 minutes after the intervention, 15 motor evoked potentials (MEPs) were elicited in tibialis anterior through transcranial magnetic stimulation. Increased MEPs were observed immediately after (62 ± 26%, 73 ± 27% for EEG- and EMG-triggered electrical stimulation, respectively) and 30 minutes after each of the two interventions (79 ± 26% and 72 ± 27%) compared to the pre-intervention measurement. There was no difference between the interventions. Both EEG- and EMG-controlled electrical stimulation can induce corticospinal plasticity which suggests that stroke patients with residual EMG can use that modality instead of EEG to trigger stimulation.
Collapse
|
12
|
Self-Paced Online vs. Cue-Based Offline Brain-Computer Interfaces for Inducing Neural Plasticity. Brain Sci 2019; 9:brainsci9060127. [PMID: 31159454 PMCID: PMC6627467 DOI: 10.3390/brainsci9060127] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 05/23/2019] [Accepted: 05/28/2019] [Indexed: 02/01/2023] Open
Abstract
: Brain-computer interfaces (BCIs), operated in a cue-based (offline) or self-paced (online) mode, can be used for inducing cortical plasticity for stroke rehabilitation by the pairing of movement-related brain activity with peripheral electrical stimulation. The aim of this study was to compare the difference in cortical plasticity induced by the two BCI modes. Fifteen healthy participants participated in two experimental sessions: cue-based BCI and self-paced BCI. In both sessions, imagined dorsiflexions were extracted from continuous electroencephalogram (EEG) and paired 50 times with the electrical stimulation of the common peroneal nerve. Before, immediately after, and 30 minutes after each intervention, the cortical excitability was measured through the motor-evoked potentials (MEPs) of tibialis anterior elicited through transcranial magnetic stimulation. Linear mixed regression models showed that the MEP amplitudes increased significantly (p < 0.05) from pre- to post- and 30-minutes post-intervention in terms of both the absolute and relative units, regardless of the intervention type. Compared to pre-interventions, the absolute MEP size increased by 79% in post- and 68% in 30-minutes post-intervention in the self-paced mode (with a true positive rate of ~75%), and by 37% in post- and 55% in 30-minutes post-intervention in the cue-based mode. The two modes were significantly different (p = 0.03) at post-intervention (relative units) but were similar at both post timepoints (absolute units). These findings suggest that immediate changes in cortical excitability may have implications for stroke rehabilitation, where it could be used as a priming protocol in conjunction with another intervention; however, the findings need to be validated in studies involving stroke patients.
Collapse
|
13
|
The effects of chiropractic spinal manipulation on central processing of tonic pain - a pilot study using standardized low-resolution brain electromagnetic tomography (sLORETA). Sci Rep 2019; 9:6925. [PMID: 31061511 PMCID: PMC6502880 DOI: 10.1038/s41598-019-42984-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 04/08/2019] [Indexed: 02/06/2023] Open
Abstract
The objectives of the study were to investigate changes in pain perception and neural activity during tonic pain due to altered sensory input from the spine following chiropractic spinal adjustments. Fifteen participants with subclinical pain (recurrent spinal dysfunction such as mild pain, ache or stiffness but with no pain on the day of the experiment) participated in this randomized cross-over study involving a chiropractic spinal adjustment and a sham session, separated by 4.0 ± 4.2 days. Before and after each intervention, 61-channel electroencephalography (EEG) was recorded at rest and during 80 seconds of tonic pain evoked by the cold-pressor test (left hand immersed in 2 °C water). Participants rated the pain and unpleasantness to the cold-pressor test on two separate numerical rating scales. To study brain sources, sLORETA was performed on four EEG frequency bands: delta (1–4 Hz), theta (4–8 Hz), alpha (8–12 Hz) and beta (12–32 Hz). The pain scores decreased by 9% after the sham intervention (p < 0.05), whereas the unpleasantness scores decreased by 7% after both interventions (p < 0.05). sLORETA showed decreased brain activity following tonic pain in all frequency bands after the sham intervention, whereas no change in activity was seen after the chiropractic spinal adjustment session. This study showed habituation to pain following the sham intervention, with no habituation occurring following the chiropractic intervention. This suggests that the chiropractic spinal adjustments may alter central processing of pain and unpleasantness.
Collapse
|