1
|
Jarosińska E, Zambrowska Z, Witkowska Nery E. Methods of Protection of Electrochemical Sensors against Biofouling in Cell Culture Applications. ACS OMEGA 2024; 9:4572-4580. [PMID: 38313548 PMCID: PMC10831843 DOI: 10.1021/acsomega.3c07660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 11/28/2023] [Accepted: 12/01/2023] [Indexed: 02/06/2024]
Abstract
In this work, we evaluated more than 10 antifouling layers presenting different modes of action for application in electrochemical sensors. These layers included porous materials, permselective membranes, hydrogels, silicate sol-gels, proteins, and sp3 hybridized carbon. To evaluate the protective effects of the antifouling modification as well as its impact on the catalyst, we adsorbed a redox mediator on the electrode surface. Five of the tested coatings allowed us to preserve the electrochemical properties of the tested mediator. Later studies showed that sol-gel silicate layer, poly-l-lactic acid, and poly(l-lysine)-g-poly(ethylene glycol) were the only ones capable of sustaining the catalyst's performance during prolonged incubation in a cell culture medium. The highest signal deterioration was observed, as expected during the first few hours of incubation in a cell culture environment. Tested layers exhibited different dynamics of the protective effect. The poly-l-lactic acid layer presented lower changes in the first hours of the study but suffered complete signal deterioration after 72 h. Whereas the signal intensity of the silicate layer was lowered by half after just 3 h but was still visible after 6 weeks of constant incubation of the electrode in the cell culture.
Collapse
Affiliation(s)
- Elżbieta Jarosińska
- Institute of Physical Chemistry,
Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland
| | | | - Emilia Witkowska Nery
- Institute of Physical Chemistry,
Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland
| |
Collapse
|
2
|
Navarro-Nateras L, Diaz-Gonzalez J, Aguas-Chantes D, Coria-Oriundo LL, Battaglini F, Ventura-Gallegos JL, Zentella-Dehesa A, Oza G, Arriaga LG, Casanova-Moreno JR. Development of a Redox-Polymer-Based Electrochemical Glucose Biosensor Suitable for Integration in Microfluidic 3D Cell Culture Systems. BIOSENSORS 2023; 13:582. [PMID: 37366947 DOI: 10.3390/bios13060582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/23/2023] [Accepted: 05/23/2023] [Indexed: 06/28/2023]
Abstract
The inclusion of online, in situ biosensors in microfluidic cell cultures is important to monitor and characterize a physiologically mimicking environment. This work presents the performance of second-generation electrochemical enzymatic biosensors to detect glucose in cell culture media. Glutaraldehyde and ethylene glycol diglycidyl ether (EGDGE) were tested as cross-linkers to immobilize glucose oxidase and an osmium-modified redox polymer on the surface of carbon electrodes. Tests employing screen printed electrodes showed adequate performance in a Roswell Park Memorial Institute (RPMI-1640) media spiked with fetal bovine serum (FBS). Comparable first-generation sensors were shown to be heavily affected by complex biological media. This difference is explained in terms of the respective charge transfer mechanisms. Under the tested conditions, electron hopping between Os redox centers was less vulnerable than H2O2 diffusion to biofouling by the substances present in the cell culture matrix. By employing pencil leads as electrodes, the incorporation of these electrodes in a polydimethylsiloxane (PDMS) microfluidic channel was achieved simply and at a low cost. Under flow conditions, electrodes fabricated using EGDGE presented the best performance with a limit of detection of 0.5 mM, a linear range up to 10 mM, and a sensitivity of 4.69 μA mM-1 cm-2.
Collapse
Affiliation(s)
- L Navarro-Nateras
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Jancarlo Diaz-Gonzalez
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Diana Aguas-Chantes
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Lucy L Coria-Oriundo
- Instituto de Química Física de los Materiales, Medio Ambiente y Energía, CONICET-Departamento de Química Inorgánica, Analítica y Química Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires C1428EGA, Argentina
| | - Fernando Battaglini
- Instituto de Química Física de los Materiales, Medio Ambiente y Energía, CONICET-Departamento de Química Inorgánica, Analítica y Química Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires C1428EGA, Argentina
| | - José Luis Ventura-Gallegos
- Departamento de Medicina Genómica y Toxicología Ambiental, Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico
| | - Alejandro Zentella-Dehesa
- Departamento de Medicina Genómica y Toxicología Ambiental, Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico
- Unidad de Bioquímica, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Ciudad de México 14080, Mexico
| | - Goldie Oza
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - L G Arriaga
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Jannu R Casanova-Moreno
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| |
Collapse
|
3
|
Xie Z, Pu H, Sun DW. Computer simulation of submicron fluid flows in microfluidic chips and their applications in food analysis. Compr Rev Food Sci Food Saf 2021; 20:3818-3837. [PMID: 34056852 DOI: 10.1111/1541-4337.12766] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 03/24/2021] [Accepted: 04/15/2021] [Indexed: 01/01/2023]
Abstract
In recent years, countries around the world have maintained a zero-tolerance attitude toward safety problems in the food industry. In order to ensure human health, a fast, sensitive, and high-throughput analysis of food contaminants is necessary to ensure safe food products on the market. Microfluidics, as a high-efficiency and sensitive detection technology, has many advantages in the detection of food contaminants, including foodborne pathogens, pesticides, heavy metal ions, toxic substances, and so forth, especially in conjunction with a variety of submicron fluid driving methods, making food detection and analysis more efficient and accurate. This review introduces the principle of submicron fluid driving modes and discusses the driving simulation of submicron fluid in microfluidic chips. In addition, the latest developments in the application of simulation in food analysis from 2006 to 2020 are discussed, and the computer simulation of submicron fluid flow in microfluidic chips and its application and development trend in food analysis are also highlighted. The review indicates that microfluidic technology, using numerical simulation as an auxiliary tool, combined with traditional methods has greatly improved the detection and analysis of food products. In addition, microfluidics combined with a variety of control methods embodies the ability of specific, multifunctional, and sensitive detection and analysis of food products. The development of high-sensitivity, high-throughput, portable, integrated microfluidic chips will enable the technology to be applied in practice.
Collapse
Affiliation(s)
- Zhaoda Xie
- School of Mechanical and Electrical Engineering, Zhongkai University of Agriculture and Engineering, Guangzhou, China.,Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou, China
| | - Hongbin Pu
- School of Food Science and Engineering, South China University of Technology, Guangzhou, China.,Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou, China.,Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, China
| | - Da-Wen Sun
- School of Food Science and Engineering, South China University of Technology, Guangzhou, China.,Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou, China.,Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, China.,Food Refrigeration and Computerized Food Technology, School of Agriculture and Food Science Centre, University College Dublin, National University of Ireland, Dublin, Ireland
| |
Collapse
|
4
|
Polymer pencil leads as a porous nanocomposite graphite material for electrochemical applications: The impact of chemical and thermal treatments. Electrochem commun 2021. [DOI: 10.1016/j.elecom.2021.107018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
5
|
Electrochemical Determination of Lead Using A Composite Sensor Obtained from Low-Cost Green Materials:Graphite/Cork. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11052355] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The purpose of this study was to develop an inexpensive, simple, and highly selective cork-modified carbon paste electrode for the determination of Pb(II) by differential pulse anodic stripping voltammetry (DPASV) and square-wave anodic stripping voltammetry (SWASV). Among the cork–graphite electrodes investigated, the one containing 70% w/w carbon showed the highest sensitivity for the determination of Pb(II) in aqueous solutions. Under SWASV conditions, its linear range and relative standard deviation are equal to 1–25 µM and 1.4%, respectively; the limit of detection complies with the value recommended by the World Health Organization. To optimize the operating conditions, the selectivity and accuracy of the analysis were further investigated by SWASV in acidic media. Finally, the electrode was successfully applied for the determination of Pb(II) in natural water samples, proving to be a sensitive electrochemical sensor that meets the stringent environmental control requirements.
Collapse
|
6
|
Podrażka M, Maciejewska J, Adamiak W, Witkowska Nery E, Jönsson-Niedziółka M. Facilitated cation transfer at a three-phase junction and its applicability for ionophore evaluation. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.03.201] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|