1
|
Promsri A, Pitiwattanakulchai P, Saodan S, Thiwan S. Age-Related Changes in Postural Stability in Response to Varying Surface Instability in Young and Middle-Aged Adults. SENSORS (BASEL, SWITZERLAND) 2024; 24:6846. [PMID: 39517743 PMCID: PMC11548703 DOI: 10.3390/s24216846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Academic Contribution Register] [Received: 09/21/2024] [Revised: 10/12/2024] [Accepted: 10/18/2024] [Indexed: 11/16/2024]
Abstract
As individuals transition into middle age, subtle declines in postural control may occur due to gradual reductions in neuromuscular control. The current study aimed to examine the effect of age on bipedal postural control across three support surfaces with varying degrees of instability: a firm surface, a foam pad, and a multiaxial balance board. The effect of surface stability was also assessed. Postural accelerations were recorded using a tri-axial accelerometer placed over the lumbar spine (L5) in 24 young female adults (23.9 ± 5.3 years) and 24 middle-aged female adults (51.4 ± 5.9 years). Sample entropy (SampEn) was used to analyze the complexity of postural control by measuring the regularity of postural acceleration. The main results show significant age-related differences in the mediolateral and anteroposterior acceleration directions (p ≤ 0.012). Young adults exhibit more irregular fluctuations in postural acceleration (high SampEn), reflecting greater efficiency or automaticity in postural control compared to middle-aged adults. Increased surface instability also progressively decreases SampEn in the mediolateral direction (p < 0.001), reflecting less automaticity with increased instability. However, no interaction effects are observed. These findings imply that incorporating balance training on unstable surfaces might help middle-aged adults maintain postural control and prevent future falls.
Collapse
Affiliation(s)
- Arunee Promsri
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 5600, Thailand; (P.P.); (S.S.); (S.T.)
- Department of Sport Science, University of Innsbruck, A-6020 Innsbruck, Austria
| | - Punnakan Pitiwattanakulchai
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 5600, Thailand; (P.P.); (S.S.); (S.T.)
| | - Siwaporn Saodan
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 5600, Thailand; (P.P.); (S.S.); (S.T.)
| | - Salinrat Thiwan
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 5600, Thailand; (P.P.); (S.S.); (S.T.)
| |
Collapse
|
2
|
Contreras C, Stanley EC, Deschamps-Prescott C, Burnap S, Hopkins M, Browning B, Christensen JC. Evaluation of Smartphone Technology on Spatiotemporal Gait in Older and Diseased Adult Populations. SENSORS (BASEL, SWITZERLAND) 2024; 24:5839. [PMID: 39275750 PMCID: PMC11397937 DOI: 10.3390/s24175839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Academic Contribution Register] [Received: 07/12/2024] [Revised: 08/23/2024] [Accepted: 08/27/2024] [Indexed: 09/16/2024]
Abstract
Objective: Advancements in smartphone technology provide availability to evaluate movement in a more practical and feasible manner, improving clinicians' ability to diagnose and treat adults at risk for mobility loss. The purpose of this study was to evaluate the validity and reliability of a smartphone application to measure spatiotemporal outcomes during level (primary) and uphill/downhill (secondary) walking with and without an assistive device for older adults (OAs), Parkinson's Disease (PD) and cerebrovascular accident (CVA) populations. Methods: A total of 50 adults (OA = 20; PD = 15; CVA = 15) underwent gait analysis at self-selected gait speeds under 0-degree, 5-degree uphill and 5-degree downhill environments. The validity and reliability of the smartphone outcomes were compared to a motion-capture laboratory. Bland-Altman analysis was used to evaluate limits of agreement between the two systems. Intraclass correlation coefficients (ICCs) were used to determine absolute agreement, and Pearson correlation coefficients (r) were used to assess the strength of the association between the two systems. Results: For level walking, Bland-Altman analysis revealed relatively equal estimations of spatiotemporal outcomes between systems for OAs without an assistive device and slight to mild under- and overestimations of outcomes between systems for PD and CVA with and without an assistive device. Moderate to very high correlations between systems (without an assistive device: OA r-range, 0.72-0.99; PD r-range, 0.87-0.97; CVA r-range, 0.56-0.99; with an assistive device: PD r-range, 0.35-0.98; CVA r-range, 0.50-0.99) were also observed. Poor to excellent ICCs for reliability between systems (without an assistive device: OA ICC range, 0.71-0.99; PD ICC range, 0.73-0.97; CVA ICC range, 0.56-0.99; with an assistive device: PD ICC range, 0.22-0.98; CVA ICC range, 0.44-0.99) were observed across all outcomes. Conclusions: This smartphone application can be clinically useful in detecting most spatiotemporal outcomes in various walking environments for older and diseased adults at risk for mobility loss.
Collapse
Affiliation(s)
- Coby Contreras
- Veterans Affairs Salt Lake City Health Care System, Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, USA
| | - Ethan C Stanley
- Veterans Affairs Salt Lake City Health Care System, Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, USA
| | - Chanc Deschamps-Prescott
- Veterans Affairs Salt Lake City Health Care System, Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, USA
| | - Susan Burnap
- Veterans Affairs Salt Lake City Health Care System, Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, USA
| | - Madison Hopkins
- Veterans Affairs Salt Lake City Health Care System, Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, USA
| | - Bennett Browning
- Veterans Affairs Salt Lake City Health Care System, Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, USA
| | - Jesse C Christensen
- Veterans Affairs Salt Lake City Health Care System, Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, USA
| |
Collapse
|
3
|
Promsri A, Deedphimai S, Promthep P, Champamuang C. Effects of Different Wearable Resistance Placements on Running Stability. Sports (Basel) 2024; 12:45. [PMID: 38393265 PMCID: PMC10892856 DOI: 10.3390/sports12020045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 12/27/2023] [Revised: 01/28/2024] [Accepted: 01/31/2024] [Indexed: 02/25/2024] Open
Abstract
Stability during running has been recognized as a crucial factor contributing to running performance. This study aimed to investigate the effects of wearable equipment containing external loads on different body parts on running stability. Fifteen recreational male runners (20.27 ± 1.23 years, age range 19-22 years) participated in five treadmill running conditions, including running without loads and running with loads equivalent to 10% of individual body weight placed on four different body positions: forearms, lower legs, trunk, and a combination of all three (forearms, lower legs, and trunk). A tri-axial accelerometer-based smartphone sensor was attached to the participants' lumbar spine (L5) to record body accelerations. The largest Lyapunov exponent (LyE) was applied to individual acceleration data as a measure of local dynamic stability, where higher LyE values suggest lower stability. The effects of load distribution appear in the mediolateral (ML) direction. Specifically, running with loads on the lower legs resulted in a lower LyE_ML value compared to running without loads (p = 0.001) and running with loads on the forearms (p < 0.001), trunk (p = 0.001), and combined segments (p = 0.005). These findings suggest that running with loads on the lower legs enhances side-to-side local dynamic stability, providing valuable insights for training.
Collapse
Affiliation(s)
- Arunee Promsri
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand; (S.D.); (P.P.); (C.C.)
| | | | | | | |
Collapse
|
4
|
Peters J, Abou L, Wong E, Dossou MS, Sosnoff JJ, Rice LA. Smartphone-based gait and balance assessment in survivors of stroke: a systematic review. Disabil Rehabil Assist Technol 2024; 19:177-187. [PMID: 35584288 DOI: 10.1080/17483107.2022.2072527] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 12/22/2021] [Accepted: 04/21/2022] [Indexed: 01/28/2023]
Abstract
PURPOSE Gait and balance impairments are associated with falls and reduced quality of life among survivors of stroke (SS). Effective methods to assess these impairments at-home and in-clinic can help reduce fall risks and improve functional outcomes. Smartphone technology may be able to evaluate these impairments. This review aims to summarize the validity, reliability, sensitivity, and specificity of smartphone applications for determining gait and balance disorders in SS. METHOD Database search through PubMed, Web of Science, Scopus, CINAHL, and SportDiscuss was conducted to retrieve studies that explored the use of smartphone-based applications for assessing gait and balance disorders in SS. Two independent reviewers screened potential articles to determine eligibility for inclusion. Eligible studies were summarized for participant and study characteristics, validity, reliability, sensitivity, and specificity of smartphone assessments. Methodological quality assessment of studies was performed using the NIH Quality Assessment Tool. RESULTS Seven cross-sectional studies were included in the review. Quality assessment revealed all studies had low risk of bias. Three of the included studies examined the validity, four examined the reliability, and two examined the specificity and sensitivity of smartphone-based application assessments of gait and balance in SS. Studies revealed that smartphones were valid, reliable, specific, and sensitive. Six of the seven included studies intended their use for SS and one study for clinicians. CONCLUSION Preliminary evidence supports that smartphone-based gait and balance assessments are valid, reliable, sensitive, and specific in SS in laboratory settings. Future research is needed to test smartphone-based gait and balance assessments in home settings and determine optimal wear sites for assessments.IMPLICATIONS FOR REHABILITATIONSmartphone-based gait and balance assessments are feasible, valid and reliable for survivors of strokeThe findings may guide future research to standardize the use of smartphone to assess gait and balance in this population.The remote use of smartphone-based assessments to predict fall risk in survivors of stroke needs to be explored.
Collapse
Affiliation(s)
- Joseph Peters
- Department of Kinesiology and Community Health, College of Applied Health Sciences, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Libak Abou
- Department of Kinesiology and Community Health, College of Applied Health Sciences, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Ellyce Wong
- Department of Kinesiology and Community Health, College of Applied Health Sciences, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | | | - Jacob J Sosnoff
- Department of Physical Therapy and Rehabilitation Science, School of Health Professions, University of Kansas Medical Center, Kansas City, KS, USA
- Illinois Multiple Sclerosis Research Collaborative, University of Illinois at Urbana Champaign, Urbana, IL, USA
| | - Laura A Rice
- Department of Kinesiology and Community Health, College of Applied Health Sciences, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Illinois Multiple Sclerosis Research Collaborative, University of Illinois at Urbana Champaign, Urbana, IL, USA
| |
Collapse
|
5
|
Devecchi V, Saunders M, Galaiya S, Shaw M, Gallina A. Remote assessment of pelvic kinematics during single leg squat using smartphone sensors: Between-day reliability and identification of acute changes in motor performance. PLoS One 2023; 18:e0288760. [PMID: 37992071 PMCID: PMC10664960 DOI: 10.1371/journal.pone.0288760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 04/28/2023] [Accepted: 07/04/2023] [Indexed: 11/24/2023] Open
Abstract
The biomechanical assessment of pelvic kinematics during a single leg squat (SLS) commonly relies on expensive equipment, which precludes its wider implementation in ecological settings. Smartphone sensors could represent an effective solution to objectively quantify pelvic kinematics remotely, but their measure properties need to be evaluated before advocating their use in practice. This study aimed to assess whether measures of pelvic kinematics collected remotely using smartphones during SLS are repeatable between days, and if changes in pelvic kinematics can be identified during an endurance task. Thirty-three healthy young adults were tested remotely on two different days using their own smartphones placed on the lumbosacral region. Pelvic orientation and acceleration were collected during three sets of seven SLS and an endurance task of twenty consecutive SLS. The intersession reliability was assessed using Intraclass Correlation Coefficient (ICC2,k), Standard Error of Measurement, and Minimal Detectable Change. T-tests were used to identify pelvic kinematics changes during the endurance task and to assess between-day bias. Measures of pelvic orientation and frequency features of the acceleration signals showed good to excellent reliability (multiple ICC2,k ≥ 0.79), and a shift of the power spectrum to lower frequencies on the second day (multiple p<0.05). The endurance task resulted in larger contralateral pelvic drop and rotation (multiple p<0.05) and increased spectral entropy (multiple p<0.05). Our findings demonstrate that reliable measures of pelvic kinematics can be obtained remotely using participants' smartphones during SLS. Smartphone sensors can also identify changes in motor control, such as contralateral pelvic drop during an endurance task.
Collapse
Affiliation(s)
- Valter Devecchi
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Michelle Saunders
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Sajni Galaiya
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Millie Shaw
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Alessio Gallina
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom
| |
Collapse
|
6
|
Promsri A, Bangkomdet K, Jindatham I, Jenchang T. Leg Dominance—Surface Stability Interaction: Effects on Postural Control Assessed by Smartphone-Based Accelerometry. Sports (Basel) 2023; 11:sports11040075. [PMID: 37104149 PMCID: PMC10145104 DOI: 10.3390/sports11040075] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 03/04/2023] [Revised: 03/19/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023] Open
Abstract
The preferential use of one leg over another in performing lower-limb motor tasks (i.e., leg dominance) is considered to be one of the internal risk factors for sports-related lower-limb injuries. The current study aimed to investigate the effects of leg dominance on postural control during unipedal balancing on three different support surfaces with increasing levels of instability: a firm surface, a foam pad, and a multiaxial balance board. In addition, the interaction effect between leg dominance and surface stability was also tested. To this end, a tri-axial accelerometer-based smartphone sensor was placed over the lumbar spine (L5) of 22 young adults (21.5 ± 0.6 years) to record postural accelerations. Sample entropy (SampEn) was applied to acceleration data as a measure of postural sway regularity (i.e., postural control complexity). The results show that leg dominance (p < 0.001) and interaction (p < 0.001) effects emerge in all acceleration directions. Specifically, balancing on the dominant (kicking) leg shows more irregular postural acceleration fluctuations (high SampEn), reflecting a higher postural control efficiency or automaticity than balancing on the non-dominant leg. However, the interaction effects suggest that unipedal balancing training on unstable surfaces is recommended to reduce interlimb differences in neuromuscular control for injury prevention and rehabilitation.
Collapse
Affiliation(s)
- Arunee Promsri
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
- Unit of Excellence in Neuromechanics, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
- Correspondence: ; Tel.: +66-54-466-666 (ext. 3817)
| | - Kotchakorn Bangkomdet
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
| | - Issariya Jindatham
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
| | - Thananya Jenchang
- Department of Physical Therapy, School of Allied Health Sciences, University of Phayao, Phayao 56000, Thailand
| |
Collapse
|
7
|
Rodrigues LA, Santos EGR, Santos PSA, Igarashi Y, Oliveira LKR, Pinto GHL, Santos Lobato BL, Cabral AS, Belgamo A, Costa e Silva AA, Callegari B, Souza GS. Wearable Devices and Smartphone Inertial Sensors for Static Balance Assessment: A Concurrent Validity Study in Young Adult Population. J Pers Med 2022; 12:jpm12071019. [PMID: 35887516 PMCID: PMC9316197 DOI: 10.3390/jpm12071019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 05/21/2022] [Revised: 06/17/2022] [Accepted: 06/18/2022] [Indexed: 11/25/2022] Open
Abstract
Falls represent a public health issue around the world and prevention is an important part of the politics of many countries. The standard method of evaluating balance is posturography using a force platform, which has high financial costs. Other instruments, such as portable devices and smartphones, have been evaluated as low-cost alternatives to the screening of balance control. Although smartphones and wearables have different sizes, shapes, and weights, they have been systematically validated for static balance control tasks. Different studies have applied different experimental configurations to validate the inertial measurements obtained by these devices. We aim to evaluate the concurrent validity of a smartphone and a portable device for the evaluation of static balance control in the same group of participants. Twenty-six healthy and young subjects comprised the sample. The validity for static balance control evaluation of built-in accelerometers inside portable smartphone and wearable devices was tested considering force platform recordings as a gold standard for comparisons. A linear correlation (r) between the quantitative variables obtained from the inertial sensors and the force platform was used as an indicator of the concurrent validity. Reliability of the measures was calculated using Intraclass correlation in a subsample (n = 14). Smartphones had 11 out of 12 variables with significant moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables in open eyes, closed eyes, and unipedal conditions, while wearable devices had 8 out of 12 variables with moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables under the same task conditions. Significant reliabilities were found in closed eye conditions for smartphones and wearables. The smartphone and wearable devices had concurrent validity for the static balance evaluation and the smartphone had better validity results than the wearables for the static balance evaluation.
Collapse
Affiliation(s)
| | - Enzo Gabriel Rocha Santos
- Instituto de Ciências Exatas e Naturais, Universidade Federal do Pará, Belém 66050-540, Brazil; (E.G.R.S.); (G.H.L.P.)
| | | | - Yuzo Igarashi
- Núcleo de Medicina Tropical, Universidade Federal do Pará, Belém 66050-540, Brazil; (L.A.R.); (Y.I.)
| | - Luana Karine Resende Oliveira
- Instituto de Ciências da Saúde, Universidade Federal do Pará, Belém 66050-540, Brazil; (L.K.R.O.); (B.L.S.L.); (A.A.C.e.S.); (B.C.)
| | - Gustavo Henrique Lima Pinto
- Instituto de Ciências Exatas e Naturais, Universidade Federal do Pará, Belém 66050-540, Brazil; (E.G.R.S.); (G.H.L.P.)
| | - Bruno Lopes Santos Lobato
- Instituto de Ciências da Saúde, Universidade Federal do Pará, Belém 66050-540, Brazil; (L.K.R.O.); (B.L.S.L.); (A.A.C.e.S.); (B.C.)
| | - André Santos Cabral
- Centro de Ciências Biológicas e da Saúde, Universidade do Estado do Pará, Belém 66087-670, Brazil;
| | - Anderson Belgamo
- Departamento de Ciência da Computação, Instituto Federal de São Paulo, Piracicaba 08021-090, Brazil;
| | - Anselmo Athayde Costa e Silva
- Instituto de Ciências da Saúde, Universidade Federal do Pará, Belém 66050-540, Brazil; (L.K.R.O.); (B.L.S.L.); (A.A.C.e.S.); (B.C.)
- Instituto de Ciências da Educação, Universidade Federal do Pará, Belém 66050-540, Brazil
| | - Bianca Callegari
- Instituto de Ciências da Saúde, Universidade Federal do Pará, Belém 66050-540, Brazil; (L.K.R.O.); (B.L.S.L.); (A.A.C.e.S.); (B.C.)
| | - Givago Silva Souza
- Núcleo de Medicina Tropical, Universidade Federal do Pará, Belém 66050-540, Brazil; (L.A.R.); (Y.I.)
- Instituto de Ciências Biológicas, Universidade Federal do Pará, Belém 66050-540, Brazil;
- Correspondence: ; Tel.: +55-91-982653131
| |
Collapse
|
8
|
Ross JD, Hoch MC, Malvasi SR, Cameron KL, Roach MH. The Relationship Between Human-rated Errors and Tablet-based Postural Sway During the Balance Error Scoring System in Military Cadets. Sports Health 2022; 15:427-432. [PMID: 35658667 PMCID: PMC10170225 DOI: 10.1177/19417381221093566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The Balance Error Scoring System (BESS) is commonly accepted as a valid measure of postural stability. However, reliability values have varied, and subtle changes undetectable with the human eye may exist postinjury. The inertial measurement unit in commercially available tablets has been used to quantify postural sway (instrumented Balance Error Scoring System [iBESS] volume). However, iBESS has not been validated in a military population, and the stability of the tests beyond 1 week is unknown. HYPOTHESIS iBESS volume is capable of objectively measuring postural sway during the traditional BESS. STUDY DESIGN Prospective repeated-measures study. LEVEL OF EVIDENCE Level 3. METHODS Eighty-three cadets (40.96% women; age 20.0 ± 1.44 years; height 68.7 ± 4.1 inches; weight 166.7 ± 30.2 lb) with no history of concussion or lower extremity injury agreed to participate. All participants completed the BESS at baseline and 6 months post baseline. During testing, a tablet equipped with an inertial measurement unit was positioned on the participant's sacrum to capture postural sway. RESULTS Moderate to strong correlations were exhibited between baseline measurements for single-limb (SL)-firm (r = 0.84; P < 0.01), tandem (TAN)-firm (r = 0.85; P < 0.01), double-limb (DL)-foam (r = 0.50; P < 0.01), SL-foam (r = 0.59; P < 0.01), and TAN-foam (r = 0.79; P < 0.01). Balance improved significantly at 6 months for SL-firm human-rated errors (Effect Size [ES] = 0.32) and for SL-firm (ES = 0.38), DL-foam (ES = 0.21), and SL-foam iBESS volume (ES = 0.35). Moderate to strong correlations were exhibited between human-rated and iBESS change scores for SL-firm (r = 0.71; P < 0.01), TAN-firm (r = 0.75; P < 0.01), and TAN-foam (r = 0.71; P < 0.01), and a weak correlation was exhibited for DL-foam (r = 0.29; P < 0.01) and SL-foam (r = 0.40; P < 0.01). CONCLUSION Moderate to strong correlations existed between human-rated BESS errors and iBESS volume at baseline and between change scores. In addition, iBESS volume may be more sensitive to balance changes than the human-rated BESS. CLINICAL RELEVANCE This evidence supports the use of iBESS volume as a valid measure of postural stability in military cadets. iBESS volume may provide clinicians with an objective and more sensitive measure of postural stability than the traditional human-rated BESS.
Collapse
|
9
|
Saalfield J, Piersol KL, Monaco R, Womack J, Weismiller SA, Esopenko C, Todaro SM, Conway FN, Brostrand K, Buckman JF. Comparison of Concurrent and Same-Day Balance Measurement Approaches in a Large Sample of Uninjured Collegiate Athletes. Int J Sports Phys Ther 2022; 17:228-236. [PMID: 35136692 PMCID: PMC8805106 DOI: 10.26603/001c.31178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 06/18/2021] [Accepted: 11/23/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Measures of postural stability are useful in assisting the diagnosing and managing of athlete concussion. Error counting using the Balance Error Scoring System (BESS) is the clinical standard, but has notable limitations. New technologies offer the potential to increase precision and optimize testing protocols; however, whether these devices enhance clinical assessment remains unclear. PURPOSE To examine the relationships between metrics of balance performance using different measurement systems in uninjured, healthy collegiate athletes. STUDY DESIGN Cross-sectional. METHODS Five hundred and thirty uninjured collegiate athletes were tested using the C3Logix app, which computes ellipsoid volume as a measure of postural stability during the six standard BESS conditions, while concurrently, errors were manually counted during each condition per standard BESS protocols. The association between concurrently measured ellipsoid volumes and error counts were examined with Spearman's correlations. From this sample, 177 participants also performed two double-leg conditions on the Biodex BioSway force plate system on the same day. This system computes Sway Index as a measure of postural stability. The association of ellipsoid volume (C3Logix) and Sway Index (Biodex) was examined with Spearman's correlations. Individual-level data were plotted to visually depict the relationships. RESULTS C3Logix ellipsoid volume and concurrently recorded error counts were significantly correlated in five of the six BESS conditions (rs:.22-.62; p< 0.0001). C3Logix ellipsoid volume and Biodex Sway Index were significantly correlated in both conditions (rs=.22-.27, p< 0.004). However, substantial variability was shown in postural stability across all three measurement approaches. CONCLUSION Modest correlation coefficients between simultaneous and same-day balance assessments in uninjured collegiate athletes suggest a need to further optimize clinical protocols for concussion diagnosis. LEVEL OF EVIDENCE 2b.
Collapse
Affiliation(s)
- Jessica Saalfield
- Department of Kinesiology and HealthRutgers University, New Brunswick, NJ, USA
| | - Kelsey L. Piersol
- Department of Kinesiology and HealthRutgers University, New Brunswick, NJ, USA
| | | | - Jason Womack
- Department of Family Medicine & Community Health, Robert Wood Johnson Medical School, Rutgers University, New Brunswick, NJ, USA; Department of Athletics, Rutgers University, New Brunswick, NJ, USA
| | - Scott A Weismiller
- Dept. of Internal Medicine, Penn State Health, Milton S. Hersey Medical Center, Hershey, PA, US
| | - Carrie Esopenko
- Department of Rehabilitation and Movement SciencesRutgers Biomedical and Health Sciences, Newark, NJ, USA
| | - Sabrina M Todaro
- Center of Alcohol and Substance Use StudiesRutgers University, New Brunswick, NJ, USA
| | - Fiona N Conway
- Steve Hicks School of Social WorkUniversity of Texas at Austin, Austin, TX, USA
| | - Kyle Brostrand
- Robert Wood Johnson Barnabas Health – Rutgers Sports MedicineRutgers University, New Brunswick, NJ, USA
| | - Jennifer F. Buckman
- Department of Kinesiology and Health, Rutgers University, New Brunswick, NJ, USA; Center of Alcohol and Substance Use Studies, Rutgers University, New Brunswick, NJ, USA
| |
Collapse
|
10
|
Jansen CP, Gordt-Oesterwind K, Schwenk M. Wearable Motion Sensors in Older Adults: On the Cutting Edge of Health and Mobility Research. SENSORS 2022; 22:s22030973. [PMID: 35161719 PMCID: PMC8837998 DOI: 10.3390/s22030973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Academic Contribution Register] [Received: 01/14/2022] [Accepted: 01/21/2022] [Indexed: 11/16/2022]
Affiliation(s)
- Carl-Philipp Jansen
- Department of Clinical Gerontology and Geriatric Rehabilitation, Robert Bosch Hospital, 70376 Stuttgart, Germany
- Institute of Sports and Sports Sciences, Heidelberg University, 69120 Heidelberg, Germany;
- Correspondence:
| | | | - Michael Schwenk
- Network Aging Research (NAR), Heidelberg University, 69115 Heidelberg, Germany;
- Human Performance Research Centre, Department of Sport Science, University of Konstanz, 78457 Konstanz, Germany
| |
Collapse
|
11
|
Validity and Reliability of a Smartphone App for Gait and Balance Assessment. SENSORS 2021; 22:s22010124. [PMID: 35009667 PMCID: PMC8747233 DOI: 10.3390/s22010124] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Academic Contribution Register] [Received: 12/01/2021] [Revised: 12/17/2021] [Accepted: 12/22/2021] [Indexed: 12/28/2022]
Abstract
Advances in technology provide an opportunity to enhance the accuracy of gait and balance assessment, improving the diagnosis and rehabilitation processes for people with acute or chronic health conditions. This study investigated the validity and reliability of a smartphone-based application to measure postural stability and spatiotemporal aspects of gait during four static balance and two gait tasks. Thirty healthy participants (aged 20–69 years) performed the following tasks: (1) standing on a firm surface with eyes opened, (2) standing on a firm surface with eyes closed, (3) standing on a compliant surface with eyes open, (4) standing on a compliant surface with eyes closed, (5) walking in a straight line, and (6) walking in a straight line while turning their head from side to side. During these tasks, the app quantified the participants’ postural stability and spatiotemporal gait parameters. The concurrent validity of the smartphone app with respect to a 3D motion capture system was evaluated using partial Pearson’s correlations (rp) and limits of the agreement (LoA%). The within-session test–retest reliability over three repeated measures was assessed with the intraclass correlation coefficient (ICC) and the standard error of measurement (SEM). One-way repeated measures analyses of variance (ANOVAs) were used to evaluate responsiveness to differences across tasks and repetitions. Periodicity index, step length, step time, and walking speed during the gait tasks and postural stability outcomes during the static tasks showed moderate-to-excellent validity (0.55 ≤ rp ≤ 0.98; 3% ≤ LoA% ≤ 12%) and reliability scores (0.52 ≤ ICC ≤ 0.92; 1% ≤ SEM% ≤ 6%) when the repetition effect was removed. Conversely, step variability and asymmetry parameters during both gait tasks generally showed poor validity and reliability except step length asymmetry, which showed moderate reliability (0.53 ≤ ICC ≤ 0.62) in both tasks when the repetition effect was removed. Postural stability and spatiotemporal gait parameters were found responsive (p < 0.05) to differences across tasks and test repetitions. Along with sound clinical judgement, the app can potentially be used in clinical practice to detect gait and balance impairments and track the effectiveness of rehabilitation programs. Further evaluation and refinement of the app in people with significant gait and balance deficits is needed.
Collapse
|
12
|
Baker N, Gough C, Gordon SJ. Inertial Sensor Reliability and Validity for Static and Dynamic Balance in Healthy Adults: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:5167. [PMID: 34372404 PMCID: PMC8348903 DOI: 10.3390/s21155167] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Academic Contribution Register] [Received: 06/06/2021] [Revised: 07/25/2021] [Accepted: 07/26/2021] [Indexed: 12/15/2022]
Abstract
Compared to laboratory equipment inertial sensors are inexpensive and portable, permitting the measurement of postural sway and balance to be conducted in any setting. This systematic review investigated the inter-sensor and test-retest reliability, and concurrent and discriminant validity to measure static and dynamic balance in healthy adults. Medline, PubMed, Embase, Scopus, CINAHL, and Web of Science were searched to January 2021. Nineteen studies met the inclusion criteria. Meta-analysis was possible for reliability studies only and it was found that inertial sensors are reliable to measure static standing eyes open. A synthesis of the included studies shows moderate to good reliability for dynamic balance. Concurrent validity is moderate for both static and dynamic balance. Sensors discriminate old from young adults by amplitude of mediolateral sway, gait velocity, step length, and turn speed. Fallers are discriminated from non-fallers by sensor measures during walking, stepping, and sit to stand. The accuracy of discrimination is unable to be determined conclusively. Using inertial sensors to measure postural sway in healthy adults provides real-time data collected in the natural environment and enables discrimination between fallers and non-fallers. The ability of inertial sensors to identify differences in postural sway components related to altered performance in clinical tests can inform targeted interventions for the prevention of falls and near falls.
Collapse
Affiliation(s)
- Nicky Baker
- Flinders Digital Health Research Centre, Flinders University, Adelaide, SA 5042, Australia; (C.G.); (S.J.G.)
| | | | | |
Collapse
|
13
|
Marques DL, Neiva HP, Pires IM, Zdravevski E, Mihajlov M, Garcia NM, Ruiz-Cárdenas JD, Marinho DA, Marques MC. An Experimental Study on the Validity and Reliability of a Smartphone Application to Acquire Temporal Variables during the Single Sit-to-Stand Test with Older Adults. SENSORS 2021; 21:s21062050. [PMID: 33803927 PMCID: PMC8000467 DOI: 10.3390/s21062050] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Academic Contribution Register] [Received: 01/22/2021] [Revised: 02/17/2021] [Accepted: 03/11/2021] [Indexed: 12/26/2022]
Abstract
Smartphone sensors have often been proposed as pervasive measurement systems to assess mobility in older adults due to their ease of use and low-cost. This study analyzes a smartphone-based application’s validity and reliability to quantify temporal variables during the single sit-to-stand test with institutionalized older adults. Forty older adults (20 women and 20 men; 78.9 ± 8.6 years) volunteered to participate in this study. All participants performed the single sit-to-stand test. Each sit-to-stand repetition was performed after an acoustic signal was emitted by the smartphone app. All data were acquired simultaneously with a smartphone and a digital video camera. The measured temporal variables were stand-up time and total time. The relative reliability and systematic bias inter-device were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plots. In contrast, absolute reliability was assessed using the standard error of measurement and coefficient of variation (CV). Inter-device concurrent validity was assessed through correlation analysis. The absolute percent error (APE) and the accuracy were also calculated. The results showed excellent reliability (ICC = 0.92–0.97; CV = 1.85–3.03) and very strong relationships inter-devices for the stand-up time (r = 0.94) and the total time (r = 0.98). The APE was lower than 6%, and the accuracy was higher than 94%. Based on our data, the findings suggest that the smartphone application is valid and reliable to collect the stand-up time and total time during the single sit-to-stand test with older adults.
Collapse
Affiliation(s)
- Diogo Luís Marques
- Department of Sport Sciences, University of Beira Interior, 6201-001 Covilhã, Portugal; (D.L.M.); (H.P.N.); (D.A.M.)
| | - Henrique Pereira Neiva
- Department of Sport Sciences, University of Beira Interior, 6201-001 Covilhã, Portugal; (D.L.M.); (H.P.N.); (D.A.M.)
- Research Center in Sports Sciences, Health Sciences and Human Development, CIDESD, 6201-001 Covilhã, Portugal
| | - Ivan Miguel Pires
- Instituto de Telecomunicações, Universidade da Beira Interior, 6200-001 Covilhã, Portugal; (I.M.P.); (N.M.G.)
- Computer Science Department, Polytechnic Institute of Viseu, 3504-510 Viseu, Portugal
- Health Sciences Research Unit: Nursing, School of Health, Polytechnic Institute of Viseu, 3504-510 Viseu, Portugal
| | - Eftim Zdravevski
- Faculty of Computer Science and Engineering, University Ss Cyril and Methodius, 1000 Skopje, North Macedonia;
| | - Martin Mihajlov
- Laboratory for Open Systems and Networks, Jozef Stefan Institute, 1000 Ljubljana, Slovenia;
| | - Nuno M. Garcia
- Instituto de Telecomunicações, Universidade da Beira Interior, 6200-001 Covilhã, Portugal; (I.M.P.); (N.M.G.)
| | - Juan Diego Ruiz-Cárdenas
- Physiotherapy Department, Faculty of Health Sciences, Catholic University of Murcia, 30107 Murcia, Spain;
| | - Daniel Almeida Marinho
- Department of Sport Sciences, University of Beira Interior, 6201-001 Covilhã, Portugal; (D.L.M.); (H.P.N.); (D.A.M.)
- Research Center in Sports Sciences, Health Sciences and Human Development, CIDESD, 6201-001 Covilhã, Portugal
| | - Mário Cardoso Marques
- Department of Sport Sciences, University of Beira Interior, 6201-001 Covilhã, Portugal; (D.L.M.); (H.P.N.); (D.A.M.)
- Research Center in Sports Sciences, Health Sciences and Human Development, CIDESD, 6201-001 Covilhã, Portugal
- Correspondence:
| |
Collapse
|
14
|
De Groote F, Vandevyvere S, Vanhevel F, Orban de Xivry JJ. Validation of a smartphone embedded inertial measurement unit for measuring postural stability in older adults. Gait Posture 2021; 84:17-23. [PMID: 33260077 DOI: 10.1016/j.gaitpost.2020.11.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Academic Contribution Register] [Received: 01/20/2020] [Revised: 11/12/2020] [Accepted: 11/15/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Identifying older adults with increased fall risk due to poor postural control on a large scale is only possible through omnipresent and low cost measuring devices such as the inertial measurement units (IMU) embedded in smartphones. However, the correlation between smartphone measures of postural stability and state-of-the-art force plate measures has never been assessed in a large sample allowing us to take into account age as a covariate. RESEARCH QUESTION How reliably can postural stability be measured with a smartphone embedded IMU in comparison to a force plate? METHODS We assessed balance in 97 adults aged 50-90 years in four different conditions (eyes open, eyes closed, semi-tandem and dual-task) in the anterio-posterior and medio-lateral directions. We used six different parameters (root mean square and average absolute value of COP displacement, velocity and acceleration) for the force plate and two different parameters (root mean square and average absolute value of COM acceleration) for the smartphone. RESULTS Test-retest reliability was smaller for the smartphone than for the force plate (intra class correlation) but both devices could equally well detect differences between conditions (similar Cohen's d). Parameters from the smartphone and the force plate, with age regressed out, were moderately correlated (robust correlation coefficients of around 0.5). SIGNIFICANCE This study comprehensively documents test-retest reliability and effect sizes for stability measures obtained with a force plate and smartphone as well as correlations between force plate and smartphone measures based on a large sample of older adults. Our large sample size allowed us to reliably determine the strength of the correlations between force plate and smartphone measures. The most important practical implication of our results is that more repetitions or longer trials are required when using a smartphone instead of a force plate to assess balance.
Collapse
Affiliation(s)
- Friedl De Groote
- KU Leuven, Department of Movement Sciences, B-3000 Leuven, Belgium.
| | - Stefanie Vandevyvere
- KU Leuven, Faculty of Rehabilitation and Movement Sciences, B-3000 Leuven, Belgium
| | - Florian Vanhevel
- KU Leuven, Faculty of Rehabilitation and Movement Sciences, B-3000 Leuven, Belgium
| | - Jean-Jacques Orban de Xivry
- KU Leuven, Department of Movement Sciences, B-3000 Leuven, Belgium; KU Leuven, Leuven Brain Institute, B-3000 Leuven, Belgium
| |
Collapse
|
15
|
Gawronska A, Pajor A, Zamyslowska-Szmytke E, Rosiak O, Jozefowicz-Korczynska M. Usefulness of Mobile Devices in the Diagnosis and Rehabilitation of Patients with Dizziness and Balance Disorders: A State of the Art Review. Clin Interv Aging 2020; 15:2397-2406. [PMID: 33376315 PMCID: PMC7764625 DOI: 10.2147/cia.s289861] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 11/01/2020] [Accepted: 12/09/2020] [Indexed: 11/23/2022] Open
Abstract
Objective The gold standard for objective body posture examination is posturography. Body movements are detected through the use of force platforms that assess static and dynamic balance (conventional posturography). In recent years, new technologies like wearable sensors (mobile posturography) have been applied during complex dynamic activities to diagnose and rehabilitate balance disorders. They are used in healthy people, especially in the aging population, for detecting falls in the older adults, in the rehabilitation of different neurological, osteoarticular, and muscular system diseases, and in vestibular disorders. Mobile devices are portable, lightweight, and less expensive than conventional posturography. The vibrotactile system can consist of an accelerometer (linear acceleration measurement), gyroscopes (angular acceleration measurement), and magnetometers (heading measurement, relative to the Earth’s magnetic field). The sensors may be mounted to the trunk (most often in the lumbar region of the spine, and the pelvis), wrists, arms, sternum, feet, or shins. Some static and dynamic clinical tests have been performed with the use of wearable sensors. Smartphones are widely used as a mobile computing platform and to evaluate the results or monitor the patient during the movement and rehabilitation. There are various mobile applications for smartphone-based balance systems. Future research should focus on validating the sensitivity and reliability of mobile device measurements compared to conventional posturography. Conclusion Smartphone based mobile devices are limited to one sensor lumbar level posturography and offer basic clinical evaluation. Single or multi sensor mobile posturography is available from different manufacturers and offers single to multi-level measurements, providing more data and in some instances even performing sophisticated clinical balance tests.
Collapse
Affiliation(s)
- Anna Gawronska
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Anna Pajor
- Department of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Ewa Zamyslowska-Szmytke
- Balance Disorders Unit, Department of Audiology and Phoniatrics, Nofer Institute of Occupational Medicine, Lodz, Poland
| | - Oskar Rosiak
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Magdalena Jozefowicz-Korczynska
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| |
Collapse
|
16
|
Papi E, Chiou SY, McGregor AH. Feasibility and acceptability study on the use of a smartphone application to facilitate balance training in the ageing population. BMJ Open 2020; 10:e039054. [PMID: 33268409 PMCID: PMC7713209 DOI: 10.1136/bmjopen-2020-039054] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Academic Contribution Register] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVES This study aims to investigate the feasibility and acceptability of using an app-based technology to train balance in the older population. DESIGN Prospective feasibility study. SETTING The study was conducted in a university setting and participants' homes. PARTICIPANTS Thirty-five volunteers ≥55 years old were recruited. INTERVENTION Participants were asked to follow a balance exercise programme 7 days a week for 3 weeks using a phone application. Seventeen participants trained for a further 3 weeks. OUTCOME MEASURES Postural sway measures during quiet standing with feet at shoulder width apart and feet together, one leg standing and tandem stance were measured at baseline, and at the end of the 3 and 6 training weeks; the International Physical Activity Questionnaire (IPAQ) assessed participants' physical activity level before training; and app acceptability was recorded using a user experience questionnaire. RESULTS Participants on the 3 and 6-week programme on average completed 20 (±5) and 38 (±11) days of training, respectively, and all scored moderate to high on the IPAQ. Between baseline and the 3-week assessments, statistically significant improvements were observed for anteroposterior sway, mediolateral sway, sway area during tandem stance, for anteroposterior sway during one leg standing and for sway area during feet together stance. Improvements were observed at 6 week compared with baseline but those between 3 and 6 weeks were not significant. Based on the questionnaire, participants reported that the app is an appropriate tool for balance training (77%), they reported benefits from the training (50%) and found it easy to fit it into daily routine (88%). CONCLUSION The high level of adherence and improvements observed in the analysed measures demonstrate the feasibility of using an app to train balance in moderately to highly physically active older participants. This demonstrates that given appropriate tools the older population is positive towards and receptive of digital interventions aimed to improve balance.
Collapse
Affiliation(s)
- Enrica Papi
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, UK
- Bioengineering Department, Imperial College London, London, UK
| | - Shin-Yi Chiou
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, UK
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, UK
| | - Alison H McGregor
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, UK
| |
Collapse
|