1
|
Feng J, Jiang Y, Wang K, Li J, Zhang J, Tian M, Chen G, Hu L, Zhan Y, Qin Y. An Energy-Efficient Flexible Multi-Modal Wireless Sweat Sensing System Based on Laser Induced Graphene. SENSORS (BASEL, SWITZERLAND) 2023; 23:4818. [PMID: 37430732 DOI: 10.3390/s23104818] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 05/10/2023] [Accepted: 05/15/2023] [Indexed: 07/12/2023]
Abstract
Real-time sweat monitoring is vital for athletes in order to reflect their physical conditions, quantify their exercise loads, and evaluate their training results. Therefore, a multi-modal sweat sensing system with a patch-relay-host topology was developed, which consisted of a wireless sensor patch, a wireless data relay, and a host controller. The wireless sensor patch can monitor the lactate, glucose, K+, and Na+ concentrations in real-time. The data is forwarded via a wireless data relay through Near Field Communication (NFC) and Bluetooth Low Energy (BLE) technology and it is finally available on the host controller. Meanwhile, existing enzyme sensors in sweat-based wearable sports monitoring systems have limited sensitivities. To improve their sensitivities, this paper proposes a dual enzyme sensing optimization strategy and demonstrates Laser-Induced Graphene (LIG)-based sweat sensors decorated with Single-Walled Carbon Nanotubes (SWCNT). Manufacturing an entire LIG array takes less than one minute and costs about 0.11 yuan in materials, making it suitable for mass production. The in vitro test result showed sensitivities of 0.53 μA/mM and 3.9 μA/mM for lactate and glucose sensing, and 32.5 mV/decade and 33.2 mV/decade for K+ and Na+ sensing, respectively. To demonstrate the ability to characterize personal physical fitness, an ex vivo sweat analysis test was also performed. Overall, the high-sensitivity lactate enzyme sensor based on SWCNT/LIG can meet the requirements of sweat-based wearable sports monitoring systems.
Collapse
Affiliation(s)
- Jiuqing Feng
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Yizhou Jiang
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Kai Wang
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Jianzheng Li
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Jialong Zhang
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Mi Tian
- Huashan Hospital, Shanghai 200040, China
| | - Guoping Chen
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Laigui Hu
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Yiqiang Zhan
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Yajie Qin
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| |
Collapse
|
2
|
Sun J, Liu G, Sun Y, Lin K, Zhou Z, Cai J. Application of Surface Electromyography in Exercise Fatigue: A Review. Front Syst Neurosci 2022; 16:893275. [PMID: 36032326 PMCID: PMC9406287 DOI: 10.3389/fnsys.2022.893275] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 06/07/2022] [Indexed: 11/13/2022] Open
Abstract
Exercise fatigue is a common physiological phenomenon in human activities. The occurrence of exercise fatigue can reduce human power output and exercise performance, and increased the risk of sports injuries. As physiological signals that are closely related to human activities, surface electromyography (sEMG) signals have been widely used in exercise fatigue assessment. Great advances have been made in the measurement and interpretation of electromyographic signals recorded on surfaces. It is a practical way to assess exercise fatigue with the use of electromyographic features. With the development of machine learning, the application of sEMG signals in human evaluation has been developed. In this article, we focused on sEMG signal processing, feature extraction, and classification in exercise fatigue. sEMG based multisource information fusion for exercise fatigue was also introduced. Finally, the development trend of exercise fatigue detection is prospected.
Collapse
|
3
|
Triantafyllopoulos A, Ottl S, Gebhard A, Rituerto-Gonzalez E, Jaumann M, Huttner S, Dieter V, Schneeweiss P, Krauss I, Gerczuk M, Amiriparian S, Schuller BW. Fatigue Prediction in Outdoor Running Conditions using Audio Data. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:2623-2626. [PMID: 36086314 DOI: 10.1109/embc48229.2022.9871225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Although running is a common leisure activity and a core training regiment for several athletes, between 29% and 79% of runners sustain an overuse injury each year. These injuries are linked to excessive fatigue, which alters how someone runs. In this work, we explore the feasibility of modelling the Borg received perception of exertion (RPE) scale (range: [6]-[19] [20]), a well-validated subjective measure of fatigue, using audio data captured in realistic outdoor environments via smartphones attached to the runners' arms. Using convolutional neural networks (CNNs) on log-Mel spectrograms, we obtain a mean absolute error (MAE) of 2.35 in subject-dependent experiments, demonstrating that audio can be effectively used to model fatigue, while being more easily and non-invasively acquired than by signals from other sensors.
Collapse
|
4
|
王 君, 孙 少, 孙 怡, 陈 竟, 彭 伟, 李 磊. [Research on muscle fatigue recognition model based on improved wavelet denoising and long short-term memory]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2022; 39:507-515. [PMID: 35788520 PMCID: PMC10950773 DOI: 10.7507/1001-5515.202107024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 03/03/2022] [Indexed: 06/15/2023]
Abstract
The automatic recognition technology of muscle fatigue has widespread application in the field of kinesiology and rehabilitation medicine. In this paper, we used surface electromyography (sEMG) to study the recognition of leg muscle fatigue during circuit resistance training. The purpose of this study was to solve the problem that the sEMG signals have a lot of noise interference and the recognition accuracy of the existing muscle fatigue recognition model is not high enough. First, we proposed an improved wavelet threshold function denoising algorithm to denoise the sEMG signal. Then, we build a muscle fatigue state recognition model based on long short-term memory (LSTM), and used the Holdout method to evaluate the performance of the model. Finally, the denoising effect of the improved wavelet threshold function denoising method proposed in this paper was compared with the denoising effect of the traditional wavelet threshold denoising method. We compared the performance of the proposed muscle fatigue recognition model with that of particle swarm optimization support vector machine (PSO-SVM) and convolutional neural network (CNN). The results showed that the new wavelet threshold function had better denoising performance than hard and soft threshold functions. The accuracy of LSTM network model in identifying muscle fatigue was 4.89% and 2.47% higher than that of PSO-SVM and CNN, respectively. The sEMG signal denoising method and muscle fatigue recognition model proposed in this paper have important implications for monitoring muscle fatigue during rehabilitation training and exercise.
Collapse
Affiliation(s)
- 君洪 王
- 中国科学院合肥物质科学研究院 智能机械研究所(合肥 230031)Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, P. R. China
- 中国科学技术大学(合肥 230026)University of Science and Technology of China, Hefei 230026, P. R. China
| | - 少明 孙
- 中国科学院合肥物质科学研究院 智能机械研究所(合肥 230031)Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, P. R. China
| | - 怡宁 孙
- 中国科学院合肥物质科学研究院 智能机械研究所(合肥 230031)Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, P. R. China
| | - 竟成 陈
- 中国科学院合肥物质科学研究院 智能机械研究所(合肥 230031)Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, P. R. China
- 中国科学技术大学(合肥 230026)University of Science and Technology of China, Hefei 230026, P. R. China
| | - 伟 彭
- 中国科学院合肥物质科学研究院 智能机械研究所(合肥 230031)Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, P. R. China
- 中国科学技术大学(合肥 230026)University of Science and Technology of China, Hefei 230026, P. R. China
| | - 磊 李
- 中国科学院合肥物质科学研究院 智能机械研究所(合肥 230031)Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, P. R. China
- 中国科学技术大学(合肥 230026)University of Science and Technology of China, Hefei 230026, P. R. China
| |
Collapse
|
5
|
Ni Z, Sun F, Li Y. Heart Rate Variability-Based Subjective Physical Fatigue Assessment. SENSORS 2022; 22:s22093199. [PMID: 35590889 PMCID: PMC9100264 DOI: 10.3390/s22093199] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/19/2022] [Accepted: 04/20/2022] [Indexed: 02/04/2023]
Abstract
Accurate assessment of physical fatigue is crucial to preventing physical injury caused by excessive exercise, overtraining during daily exercise and professional sports training. However, as a subjective feeling of an individual, physical fatigue is difficult for others to objectively evaluate. Heart rate variability (HRV), which is derived from electrocardiograms (ECG) and controlled by the autonomic nervous system, has been demonstrated to be a promising indicator for physical fatigue estimation. In this paper, we propose a novel method for the automatic and objective classification of physical fatigue based on HRV. First, a total of 24 HRV features were calculated. Then, a feature selection method was proposed to remove useless features that have a low correlation with physical fatigue and redundant features that have a high correlation with the selected features. After feature selection, the best 11 features were selected and were finally used for physical fatigue classifying. Four machine learning algorithms were trained to classify fatigue using the selected features. The experimental results indicate that the model trained using the selected 11 features could classify physical fatigue with high accuracy. More importantly, these selected features could provide important information regarding the identification of physical fatigue.
Collapse
Affiliation(s)
- Zhiqiang Ni
- Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Z.N.); (F.S.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fangmin Sun
- Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Z.N.); (F.S.)
| | - Ye Li
- Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Z.N.); (F.S.)
- Correspondence:
| |
Collapse
|
6
|
Adão Martins NR, Annaheim S, Spengler CM, Rossi RM. Fatigue Monitoring Through Wearables: A State-of-the-Art Review. Front Physiol 2022; 12:790292. [PMID: 34975541 PMCID: PMC8715033 DOI: 10.3389/fphys.2021.790292] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 11/22/2021] [Indexed: 11/13/2022] Open
Abstract
The objective measurement of fatigue is of critical relevance in areas such as occupational health and safety as fatigue impairs cognitive and motor performance, thus reducing productivity and increasing the risk of injury. Wearable systems represent highly promising solutions for fatigue monitoring as they enable continuous, long-term monitoring of biomedical signals in unattended settings, with the required comfort and non-intrusiveness. This is a p rerequisite for the development of accurate models for fatigue monitoring in real-time. However, monitoring fatigue through wearable devices imposes unique challenges. To provide an overview of the current state-of-the-art in monitoring variables associated with fatigue via wearables and to detect potential gaps and pitfalls in current knowledge, a systematic review was performed. The Scopus and PubMed databases were searched for articles published in English since 2015, having the terms "fatigue," "drowsiness," "vigilance," or "alertness" in the title, and proposing wearable device-based systems for non-invasive fatigue quantification. Of the 612 retrieved articles, 60 satisfied the inclusion criteria. Included studies were mainly of short duration and conducted in laboratory settings. In general, researchers developed fatigue models based on motion (MOT), electroencephalogram (EEG), photoplethysmogram (PPG), electrocardiogram (ECG), galvanic skin response (GSR), electromyogram (EMG), skin temperature (Tsk), eye movement (EYE), and respiratory (RES) data acquired by wearable devices available in the market. Supervised machine learning models, and more specifically, binary classification models, are predominant among the proposed fatigue quantification approaches. These models were considered to perform very well in detecting fatigue, however, little effort was made to ensure the use of high-quality data during model development. Together, the findings of this review reveal that methodological limitations have hindered the generalizability and real-world applicability of most of the proposed fatigue models. Considerably more work is needed to fully explore the potential of wearables for fatigue quantification as well as to better understand the relationship between fatigue and changes in physiological variables.
Collapse
Affiliation(s)
- Neusa R Adão Martins
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland.,Exercise Physiology Lab, Institute of Human Movement Sciences and Sport, ETH Zurich, Zurich, Switzerland
| | - Simon Annaheim
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland
| | - Christina M Spengler
- Exercise Physiology Lab, Institute of Human Movement Sciences and Sport, ETH Zurich, Zurich, Switzerland.,Zurich Center for Integrative Human Physiology (ZIHP), University of Zurich, Zurich, Switzerland
| | - René M Rossi
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland
| |
Collapse
|
7
|
A Muscle Fatigue Classification Model Based on LSTM and Improved Wavelet Packet Threshold. SENSORS 2021; 21:s21196369. [PMID: 34640689 PMCID: PMC8512101 DOI: 10.3390/s21196369] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 09/10/2021] [Accepted: 09/16/2021] [Indexed: 11/29/2022]
Abstract
Previous studies have used the anaerobic threshold (AT) to non-invasively predict muscle fatigue. This study proposes a novel method for the automatic classification of muscle fatigue based on surface electromyography (sEMG). The sEMG data were acquired from 20 participants during an incremental test on a cycle ergometer using sEMG sensors placed on the vastus rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), and gastrocnemius (GA) muscles of the left leg. The ventilation volume (VE), oxygen uptake (VO2), and carbon dioxide production (VCO2) data of each participant were collected during the test. Then, we extracted the time-domain and frequency-domain features of the sEMG signal denoised by the improved wavelet packet threshold denoising algorithm. In this study, we propose a new muscle fatigue recognition model based on the long short-term memory (LSTM) network. The LSTM network was trained to classify muscle fatigue using sEMG signal features. The results showed that the improved wavelet packet threshold function has better performance in denoising sEMG signals than hard threshold and soft threshold functions. The classification performance of the muscle fatigue recognition model proposed in this paper is better than that of CNN (convolutional neural network), SVM (support vector machine), and the classification models proposed by other scholars. The best performance of the LSTM network was achieved with 70% training, 10% validation, and 20% testing rates. Generally, the proposed model can be used to monitor muscle fatigue.
Collapse
|
8
|
Wang J, Cao D, Wang J, Liu C. Action Recognition of Lower Limbs Based on Surface Electromyography Weighted Feature Method. SENSORS (BASEL, SWITZERLAND) 2021; 21:6147. [PMID: 34577352 PMCID: PMC8470121 DOI: 10.3390/s21186147] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 09/03/2021] [Accepted: 09/08/2021] [Indexed: 11/16/2022]
Abstract
To improve the recognition rate of lower limb actions based on surface electromyography (sEMG), an effective weighted feature method is proposed, and an improved genetic algorithm support vector machine (IGA-SVM) is designed in this paper. First, for the problem of high feature redundancy and low discrimination in the surface electromyography feature extraction process, the weighted feature method is proposed based on the correlation between muscles and actions. Second, to solve the problem of the genetic algorithm selection operator easily falling into a local optimum solution, the improved genetic algorithm-support vector machine is designed by championship with sorting method. Finally, the proposed method is used to recognize six types of lower limb actions designed, and the average recognition rate reaches 94.75%. Experimental results indicate that the proposed method has definite potentiality in lower limb action recognition.
Collapse
Affiliation(s)
- Jiashuai Wang
- School of Engineering, Qufu Normal University, Rizhao 276826, China; (J.W.); (J.W.)
| | - Dianguo Cao
- School of Engineering, Qufu Normal University, Rizhao 276826, China; (J.W.); (J.W.)
| | - Jinqiang Wang
- School of Engineering, Qufu Normal University, Rizhao 276826, China; (J.W.); (J.W.)
| | - Chengyu Liu
- School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China;
| |
Collapse
|
9
|
Orejel Bustos A, Belluscio V, Camomilla V, Lucangeli L, Rizzo F, Sciarra T, Martelli F, Giacomozzi C. Overuse-Related Injuries of the Musculoskeletal System: Systematic Review and Quantitative Synthesis of Injuries, Locations, Risk Factors and Assessment Techniques. SENSORS (BASEL, SWITZERLAND) 2021; 21:2438. [PMID: 33916269 PMCID: PMC8037357 DOI: 10.3390/s21072438] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 03/24/2021] [Accepted: 03/30/2021] [Indexed: 12/19/2022]
Abstract
Overuse-related musculoskeletal injuries mostly affect athletes, especially if involved in preseason conditioning, and military populations; they may also occur, however, when pathological or biological conditions render the musculoskeletal system inadequate to cope with a mechanical load, even if moderate. Within the MOVIDA (Motor function and Vitamin D: toolkit for risk Assessment and prediction) Project, funded by the Italian Ministry of Defence, a systematic review of the literature was conducted to support the development of a transportable toolkit (instrumentation, protocols and reference/risk thresholds) to help characterize the risk of overuse-related musculoskeletal injury. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) approach was used to analyze Review papers indexed in PubMed and published in the period 2010 to 2020. The search focused on stress (overuse) fracture or injuries, and muscle fatigue in the lower limbs in association with functional (biomechanical) or biological biomarkers. A total of 225 Review papers were retrieved: 115 were found eligible for full text analysis and led to another 141 research papers derived from a second-level search. A total of 183 papers were finally chosen for analysis: 74 were classified as introductory to the topics, 109 were analyzed in depth. Qualitative and, wherever possible, quantitative syntheses were carried out with respect to the literature review process and quality, injury epidemiology (type and location of injuries, and investigated populations), risk factors, assessment techniques and assessment protocols.
Collapse
Affiliation(s)
- Amaranta Orejel Bustos
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, 00135 Rome, Italy; (A.O.B.); (V.B.); (V.C.); (L.L.)
| | - Valeria Belluscio
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, 00135 Rome, Italy; (A.O.B.); (V.B.); (V.C.); (L.L.)
| | - Valentina Camomilla
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, 00135 Rome, Italy; (A.O.B.); (V.B.); (V.C.); (L.L.)
| | - Leandro Lucangeli
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, 00135 Rome, Italy; (A.O.B.); (V.B.); (V.C.); (L.L.)
| | - Francesco Rizzo
- Joint Veterans Defence Center, Army Medical Center, 00184 Rome, Italy; (F.R.); (T.S.)
| | - Tommaso Sciarra
- Joint Veterans Defence Center, Army Medical Center, 00184 Rome, Italy; (F.R.); (T.S.)
| | - Francesco Martelli
- Department of Cardiovascular and Endocrine-Metabolic Diseases and Aging, Italian National Institute of Health, 00161 Rome, Italy;
| | - Claudia Giacomozzi
- Department of Cardiovascular and Endocrine-Metabolic Diseases and Aging, Italian National Institute of Health, 00161 Rome, Italy;
| |
Collapse
|
10
|
Fatigue Monitoring in Running Using Flexible Textile Wearable Sensors. SENSORS 2020; 20:s20195573. [PMID: 33003316 PMCID: PMC7582404 DOI: 10.3390/s20195573] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 09/22/2020] [Accepted: 09/23/2020] [Indexed: 12/22/2022]
Abstract
Fatigue is a multifunctional and complex phenomenon that affects how individuals perform an activity. Fatigue during running causes changes in normal gait parameters and increases the risk of injury. To address this problem, wearable sensors have been proposed as an unobtrusive and portable system to measure changes in human movement as a result of fatigue. Recently, a category of wearable devices that has gained attention is flexible textile strain sensors because of their ability to be woven into garments to measure kinematics. This study uses flexible textile strain sensors to continuously monitor the kinematics during running and uses a machine learning approach to estimate the level of fatigue during running. Five female participants used the sensor-instrumented garment while running to a state of fatigue. In addition to the kinematic data from the flexible textile strain sensors, the perceived level of exertion was monitored for each participant as an indication of their actual fatigue level. A stacked random forest machine learning model was used to estimate the perceived exertion levels from the kinematic data. The machine learning algorithm obtained a root mean squared value of 0.06 and a coefficient of determination of 0.96 in participant-specific scenarios. This study highlights the potential of flexible textile strain sensors to objectively estimate the level of fatigue during running by detecting slight perturbations in lower extremity kinematics. Future iterations of this technology may lead to real-time biofeedback applications that could reduce the risk of running-related overuse injuries.
Collapse
|
11
|
Qin P, Shi X. Evaluation of Feature Extraction and Classification for Lower Limb Motion Based on sEMG Signal. ENTROPY 2020; 22:e22080852. [PMID: 33286623 PMCID: PMC7517453 DOI: 10.3390/e22080852] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 07/29/2020] [Accepted: 07/30/2020] [Indexed: 12/12/2022]
Abstract
The real-time and accuracy of motion classification plays an essential role for the elderly or frail people in daily activities. This study aims to determine the optimal feature extraction and classification method for the activities of daily living (ADL). In the experiment, we collected surface electromyography (sEMG) signals from thigh semitendinosus, lateral thigh muscle, and calf gastrocnemius of the lower limbs to classify horizontal walking, crossing obstacles, standing up, going down the stairs, and going up the stairs. Firstly, we analyzed 11 feature extraction methods, including time domain, frequency domain, time-frequency domain, and entropy. Additionally, a feature evaluation method was proposed, and the separability of 11 feature extraction algorithms was calculated. Then, combined with 11 feature algorithms, the classification accuracy and time of 55 classification methods were calculated. The results showed that the Gaussian Kernel Linear Discriminant Analysis (GK-LDA) with WAMP had the highest classification accuracy rate (96%), and the calculation time was below 80 ms. In this paper, the quantitative comparative analysis of feature extraction and classification methods was a benefit to the application for the wearable sEMG sensor system in ADL.
Collapse
Affiliation(s)
| | - Xin Shi
- Correspondence: (P.Q.); (X.S.)
| |
Collapse
|
12
|
Change-Point Detection of Peak Tibial Acceleration in Overground Running Retraining. SENSORS 2020; 20:s20061720. [PMID: 32204499 PMCID: PMC7147709 DOI: 10.3390/s20061720] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 03/06/2020] [Accepted: 03/10/2020] [Indexed: 12/17/2022]
Abstract
A method is presented for detecting changes in the axial peak tibial acceleration while adapting to self-discovered lower-impact running. Ten runners with high peak tibial acceleration were equipped with a wearable auditory biofeedback system. They ran on an athletic track without and with real-time auditory biofeedback at the instructed speed of 3.2 m·s-1. Because inter-subject variation may underline the importance of individualized retraining, a change-point analysis was used for each subject. The tuned change-point application detected major and subtle changes in the time series. No changes were found in the no-biofeedback condition. In the biofeedback condition, a first change in the axial peak tibial acceleration occurred on average after 309 running gait cycles (3'40"). The major change was a mean reduction of 2.45 g which occurred after 699 running gait cycles (8'04") in this group. The time needed to achieve the major reduction varied considerably between subjects. Because of the individualized approach to gait retraining and its relatively quick response due to a strong sensorimotor coupling, we want to highlight the potential of a stand-alone biofeedback system that provides real-time, continuous, and auditory feedback in response to the axial peak tibial acceleration for lower-impact running.
Collapse
|