1
|
Wieser HP, Huang Y, Schauer J, Lascaud J, Würl M, Lehrack S, Radonic D, Vidal M, Hérault J, Chmyrov A, Ntziachristos V, Assmann W, Parodi K, Dollinger G. Experimental demonstration of accurate Bragg peak localization with ionoacoustic tandem phase detection (iTPD). Phys Med Biol 2021; 66. [PMID: 34847532 DOI: 10.1088/1361-6560/ac3ead] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 11/30/2021] [Indexed: 11/12/2022]
Abstract
Accurate knowledge of the exact stopping location of ions inside the patient would allow full exploitation of their ballistic properties for patient treatment. The localized energy deposition of a pulsed particle beam induces a rapid temperature increase of the irradiated volume and leads to the emission of ionoacoustic (IA) waves. Detecting the time-of-flight (ToF) of the IA wave allows inferring information on the Bragg peak location and can henceforth be used forin-vivorange verification. A challenge for IA is the poor signal-to-noise ratio at clinically relevant doses and viable machines. We present a frequency-based measurement technique, labeled as ionoacoustic tandem phase detection (iTPD) utilizing lock-in amplifiers. The phase shift of the IA signal to a reference signal is measured to derive theToF. Experimental IA measurements with a 3.5 MHz lead zirconate titanate (PZT) transducer and lock-in amplifiers were performed in water using 22 MeV proton bursts. A digital iTPD was performedin-silicoat clinical dose levels on experimental data obtained from a clinical facility and secondly, on simulations emulating a heterogeneous geometry. For the experimental setup using 22 MeV protons, a localization accuracy and precision obtained through iTPD deviates from a time-based reference analysis by less than 15μm. Several methodological aspects were investigated experimentally in systematic manner. Lastly, iTPD was evaluatedin-silicofor clinical beam energies indicating that iTPD is in reach of sub-mm accuracy for fractionated doses < 5 Gy. iTPD can be used to accurately measure theToFof IA signals online via its phase shift in frequency domain. An application of iTPD to the clinical scenario using a single pulsed beam is feasible but requires further development to reach <1 Gy detection capabilities.
Collapse
Affiliation(s)
- H P Wieser
- Department for Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, D-85748 Garching b. München, Germany
| | - Y Huang
- Chair of Biological Imaging (CBI) and Center for Translational Cancer Research (TranslaTUM) Technical University Munich, D-81675 Munich, Germany.,Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, D-85764 Neuherberg, Germany
| | - J Schauer
- Institute for Applied Physics and Metrology, Department of Aerospace Engineering, Universität der Bundeswehr München, D-85577 Neubiberg, Germany
| | - J Lascaud
- Department for Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, D-85748 Garching b. München, Germany
| | - M Würl
- Department for Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, D-85748 Garching b. München, Germany
| | - S Lehrack
- Department for Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, D-85748 Garching b. München, Germany
| | - D Radonic
- Department for Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, D-85748 Garching b. München, Germany
| | - M Vidal
- Centre Antoine Lacassagne-Fédération Claude Lalanne, 227 avenue de Lanterne, F-06200 Nice, France
| | - J Hérault
- Centre Antoine Lacassagne-Fédération Claude Lalanne, 227 avenue de Lanterne, F-06200 Nice, France
| | - A Chmyrov
- Chair of Biological Imaging (CBI) and Center for Translational Cancer Research (TranslaTUM) Technical University Munich, D-81675 Munich, Germany.,Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, D-85764 Neuherberg, Germany
| | - V Ntziachristos
- Chair of Biological Imaging (CBI) and Center for Translational Cancer Research (TranslaTUM) Technical University Munich, D-81675 Munich, Germany.,Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, D-85764 Neuherberg, Germany
| | - W Assmann
- Department for Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, D-85748 Garching b. München, Germany
| | - K Parodi
- Department for Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, D-85748 Garching b. München, Germany
| | - G Dollinger
- Institute for Applied Physics and Metrology, Department of Aerospace Engineering, Universität der Bundeswehr München, D-85577 Neubiberg, Germany
| |
Collapse
|