1
|
Yang G, Hong J, Park SB. Wearable device for continuous sweat lactate monitoring in sports: a narrative review. Front Physiol 2024; 15:1376801. [PMID: 38638276 PMCID: PMC11025537 DOI: 10.3389/fphys.2024.1376801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 03/22/2024] [Indexed: 04/20/2024] Open
Abstract
In sports science, the use of wearable technology has facilitated the development of new approaches for tracking and assessing athletes' performance. This narrative review rigorously explores the evolution and contemporary state of wearable devices specifically engineered for continuously monitoring lactate levels in sweat, an essential biomarker for appraising endurance performance. Lactate threshold tests have traditionally been integral in tailoring training intensity for athletes, but these tests have relied on invasive blood tests that are impractical outside a laboratory setting. The transition to noninvasive, real-time monitoring through wearable technology introduces an innovative approach, facilitating continuous assessment without the constraints inherent in traditional methodologies. We selected 34 products from a pool of 246 articles found through a meticulous search of articles published up to January 2024 in renowned databases: PubMed, Web of Science, and ScienceDirect. We used keywords such as "sweat lactate monitoring," "continuous lactate monitoring," and "wearable devices." The findings underscore the capabilities of noninvasive sweat lactate monitoring technologies to conduct long-term assessments over a broad range of 0-100 mM, providing a safer alternative with minimal infection risks. By enabling real-time evaluations of the lactate threshold (LT) and maximal lactate steady state (MLSS), these technologies offer athletes various device options tailored to their specific sports and preferences. This review explores the mechanisms of currently available lactate monitoring technologies, focusing on electrochemical sensors that have undergone extensive research and show promise for commercialization. These sensors employ amperometric reactions to quantify lactate levels and detect changes resulting from enzymatic activities. In contrast, colorimetric sensors offer a more straightforward and user-friendly approach by displaying lactate concentrations through color alterations. Despite significant advancements, the relationship between sweat lactate and blood lactate levels remains intricate owing to various factors such as environmental conditions and the lag between exercise initiation and sweating. Furthermore, there is a marked gap in research on sweat lactate compared to blood lactate across various sports disciplines. This review highlights the need for further research to address these shortcomings and substantiate the performance of lactate sweat monitoring technologies in a broader spectrum of sports environments. The tremendous potential of these technologies to supplant invasive blood lactate tests and pioneer new avenues for athlete management and performance optimization in real-world settings heralds a promising future for integrating sports science and wearable technology.
Collapse
Affiliation(s)
| | - Junggi Hong
- *Correspondence: Seung-Bo Park, ; Junggi Hong,
| | | |
Collapse
|
2
|
Lafuente JL, González S, Aibar C, Rivera D, Avilés E, Beunza JJ. Continuous and Non-Invasive Lactate Monitoring Techniques in Critical Care Patients. BIOSENSORS 2024; 14:148. [PMID: 38534255 DOI: 10.3390/bios14030148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 03/05/2024] [Accepted: 03/09/2024] [Indexed: 03/28/2024]
Abstract
Lactate, once merely regarded as an indicator of tissue hypoxia and muscular fatigue, has now gained prominence as a pivotal biomarker across various medical disciplines. Recent research has unveiled its critical role as a high-value prognostic marker in critical care medicine. The current practice of lactate detection involves periodic blood sampling. This approach is invasive and confined to measurements at six-hour intervals, leading to resource expenditure, time consumption, and patient discomfort. This review addresses non-invasive sensors that enable continuous monitoring of lactate in critical care patients. After the introduction, it discusses the iontophoresis system, followed by a description of the structural materials that are universally employed to create an interface between the integumentary system and the sensor. Subsequently, each method is detailed according to its physical principle, outlining its advantages, limitations, and pertinent aspects. The study concludes with a discussion and conclusions, aiming at the design of an intelligent sensor (Internet of Medical Things or IoMT) to facilitate continuous lactate monitoring and enhance the clinical decision-making support system in critical care medicine.
Collapse
Affiliation(s)
- Jose-Luis Lafuente
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Samuel González
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Intensive Care Unit, Hospital Universitario HLA Moncloa, 28008 Madrid, Spain
| | - Clara Aibar
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Desirée Rivera
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Eva Avilés
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Juan-Jose Beunza
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Research and Doctorate School, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Department of Medicine, Health and Sports, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| |
Collapse
|
3
|
Thongkhao P, Numnuam A, Khongkow P, Sangkhathat S, Phairatana T. Disposable Polyaniline/ m-Phenylenediamine-Based Electrochemical Lactate Biosensor for Early Sepsis Diagnosis. Polymers (Basel) 2024; 16:473. [PMID: 38399851 PMCID: PMC10892424 DOI: 10.3390/polym16040473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/26/2024] [Accepted: 02/06/2024] [Indexed: 02/25/2024] Open
Abstract
Lactate serves as a crucial biomarker that indicates sepsis assessment in critically ill patients. A rapid, accurate, and portable analytical device for lactate detection is required. This work developed a stepwise polyurethane-polyaniline-m-phenylenediamine via a layer-by-layer based electrochemical biosensor, using a screen-printed gold electrode for lactate determination in blood samples. The developed lactate biosensor was electrochemically fabricated with layers of m-phenylenediamine, polyaniline, a crosslinking of a small amount of lactate oxidase via glutaraldehyde, and polyurethane as an outer membrane. The lactate determination using amperometry revealed the biosensor's performance with a wide linear range of 0.20-5.0 mmol L-1, a sensitivity of 12.17 ± 0.02 µA·mmol-1·L·cm-2, and a detection limit of 7.9 µmol L-1. The developed biosensor exhibited a fast response time of 5 s, high selectivity, excellent long-term storage stability over 10 weeks, and good reproducibility with 3.74% RSD. Additionally, the determination of lactate in human blood plasma using the developed lactate biosensor was examined. The results were in agreement with the enzymatic colorimetric gold standard method (p > 0.05). Our developed biosensor provides efficiency, reliability, and is a great potential tool for advancing lactate point-of-care testing applications in the early diagnosis of sepsis.
Collapse
Affiliation(s)
- Piromya Thongkhao
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
| | - Apon Numnuam
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Songkhla 90110, Thailand
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Songkhla 90110, Thailand
| | - Pasarat Khongkow
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
- Translational Medicine Research Center, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
- Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
| | - Surasak Sangkhathat
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
- Translational Medicine Research Center, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
- Department of Surgery, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
| | - Tonghathai Phairatana
- Department of Biomedical Sciences and Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
- Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
| |
Collapse
|
4
|
Mishi RD, Stokes MA, Campbell CA, Plaxco KW, Stocker SL. Real-Time Monitoring of Antibiotics in the Critically Ill Using Biosensors. Antibiotics (Basel) 2023; 12:1478. [PMID: 37887179 PMCID: PMC10603738 DOI: 10.3390/antibiotics12101478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 08/14/2023] [Accepted: 09/11/2023] [Indexed: 10/28/2023] Open
Abstract
By ensuring optimal dosing, therapeutic drug monitoring (TDM) improves outcomes in critically ill patients by maximizing effectiveness while minimizing toxicity. Current methods for measuring plasma drug concentrations, however, can be challenging, time-consuming, and slow to return an answer, limiting the extent to which TDM is used to optimize drug exposure. A potentially promising solution to this dilemma is provided by biosensors, molecular sensing devices that employ biorecognition elements to recognize and quantify their target molecules rapidly and in a single step. This paper reviews the current state of the art for biosensors regarding their application to TDM of antibiotics in the critically ill, both as ex vivo point-of-care devices supporting single timepoint measurements and in vivo devices supporting continuous real-time monitoring in situ in the body. This paper also discusses the clinical development of biosensors for TDM, including regulatory challenges and the need for standardized performance evaluation. We conclude by arguing that, through precise and real-time monitoring of antibiotics, the application of biosensors in TDM holds great promise for enhancing the optimization of drug exposure in critically ill patients, offering the potential for improved outcomes.
Collapse
Affiliation(s)
- Ruvimbo Dephine Mishi
- Department of Human Biology, Division of Cell Biology, University of Cape Town, Cape Town 7925, South Africa
| | - Michael Andrew Stokes
- Paediatric Critical Care Unit, Department of Pharmacy, The Children’s Hospital at Westmead, Sydney, NSW 2031, Australia
| | - Craig Anthony Campbell
- NSW Health Pathology, Department of Chemical Pathology, Prince of Wales Hospital, Sydney, NSW 2031, Australia
| | - Kevin William Plaxco
- Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, CA 93106, USA
- Center for Bioengineering, University of California Santa Barbara, Santa Barbara, CA 93106, USA
- Biomolecular Sciences and Engineering, University of California, Santa Barbara, CA 93106, USA
| | - Sophie Lena Stocker
- School of Pharmacy, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW 2006, Australia
- Department of Clinical Pharmacology and Toxicology, St. Vincent’s Hospital, Sydney, NSW 2010, Australia
- Sydney Institute for Infectious Diseases, University of Sydney, Sydney, NSW 2006, Australia
| |
Collapse
|
5
|
Roberto de Oliveira P, Crapnell RD, Garcia-Miranda Ferrari A, Wuamprakhon P, Hurst NJ, Dempsey-Hibbert NC, Sawangphruk M, Janegitz BC, Banks CE. Low-cost, facile droplet modification of screen-printed arrays for internally validated electrochemical detection of serum procalcitonin. Biosens Bioelectron 2023; 228:115220. [PMID: 36924686 DOI: 10.1016/j.bios.2023.115220] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 02/27/2023] [Accepted: 03/07/2023] [Indexed: 03/13/2023]
Abstract
This manuscript presents the design and facile production of screen-printed arrays (SPAs) for the internally validated determination of raised levels of serum procalcitonin (PCT). The screen-printing methodology produced SPAs with six individual working electrodes that exhibit an inter-array reproducibility of 3.64% and 5.51% for the electrochemically active surface area and heterogenous electrochemical rate constant respectively. The SPAs were modified with antibodies specific for the detection of PCT through a facile methodology, where each stage simply uses droplets incubated on the surface, allowing for their mass-production. This platform was used for the detection of PCT, achieving a linear dynamic range between 1 and 10 ng mL-1 with a sensor sensitivity of 1.35 × 10-10 NIC%/ng mL-1. The SPA produced an intra- and inter-day %RSD of 4.00 and 5.05%, with a material cost of £1.14. Internally validated human serum results (3 sample measurements, 3 control) for raised levels of PCT (>2 ng mL-1) were obtained, with no interference effects seen from CRP and IL-6. This SPA platform has the potential to offer clinicians vital information to rapidly begin treatment for "query sepsis" patients while awaiting results from more lengthy remote laboratory testing methods. Analytical ranges tested make this an ideal approach for rapid testing in specific patient populations (such as neonates or critically ill patients) in which PCT ranges are inherently wider. Due to the facile modification methods, we predict this could be used for various analytes on a single array, or the array increased further to maintain the internal validation of the system.
Collapse
Affiliation(s)
- Paulo Roberto de Oliveira
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, United Kingdom; Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras, 13600-970, Brazil
| | - Robert D Crapnell
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, United Kingdom
| | | | - Phatsawit Wuamprakhon
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, United Kingdom; Centre of Excellence for Energy Storage Technology (CEST), Department of Chemical and Biomolecular Engineering, School of Energy Science and Engineering, Vidyasirimedhi Institute of Science and Technology, Rayong, 21210, Thailand
| | - Nicholas J Hurst
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, United Kingdom
| | - Nina C Dempsey-Hibbert
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, United Kingdom
| | - Montree Sawangphruk
- Centre of Excellence for Energy Storage Technology (CEST), Department of Chemical and Biomolecular Engineering, School of Energy Science and Engineering, Vidyasirimedhi Institute of Science and Technology, Rayong, 21210, Thailand
| | - Bruno Campos Janegitz
- Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras, 13600-970, Brazil
| | - Craig E Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, United Kingdom.
| |
Collapse
|
6
|
Hyperlactatemia and other perioperative metabolic disturbances in neuroanesthesia. Curr Opin Anaesthesiol 2022; 35:537-542. [PMID: 35942723 PMCID: PMC9594138 DOI: 10.1097/aco.0000000000001180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE OF REVIEW The concept of 'brain-body cross-talking' has gained growing interest in the last years. The understanding of the metabolic disturbances (e.g., hypernatraemia/hyponatraemia and hyperlactatemia) in neurosurgical patients has improved during the last years. RECENT FINDINGS The impact of elevated lactate without acidosis in neurosurgical patients remains controversial. The pathophysiology of inappropriate secretion of antidiuretic hormone (SIADH) has become clearer, whereas the diagnosis of cerebral salt wasting should be used more carefully. SUMMARY These findings will contribute to a better understanding of the pathophysiology involved and enable better prevention and therapy where possible in clinical practice.
Collapse
|