1
|
Xu Q, Xi Y, Wang L, Xu M, Ruan T, Du Z, Jiang C, Cao J, Zhu X, Wang X, Yang B, Liu J. In situ self-referenced intracellular two-electrode system for enhanced accuracy in single-cell analysis. Biosens Bioelectron 2024; 253:116173. [PMID: 38432075 DOI: 10.1016/j.bios.2024.116173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 02/19/2024] [Accepted: 02/26/2024] [Indexed: 03/05/2024]
Abstract
Since the emergence of single-cell electroanalysis, the two-electrode system has become the predominant electrochemical system for real-time behavioral analysis of single-cell and multicellular populations. However, due to the transmembrane placement of the two electrodes, cellular activities can be interrupted by the transmembrane potentials, and the test results are susceptible to influences from factors such as intracellular solution, membrane, and bulk solution. These limitations impede the advancement of single-cell analysis. Here, we propose a highly miniaturized and integrated in situ self-referenced intracellular two-electrode system (IS-SRITES), wherein both the working and reference electrodes are positioned inside the cell. Additionally, we demonstrated the stability (0.28 mV/h) of the solid-contact in situ Ag/AgCl reference electrode and the ability of the system to conduct standard electrochemical testing in a wide pH range (pH 6.0-8.0). Cell experiments confirmed the non-destructive performance of the electrode system towards cells and its capacity for real-time monitoring of intra- and extracellular pH values. Moreover, through equivalent circuits, finite element simulations, and drug delivery experiments, we illustrated that the IS-SRITES can yield more accurate test results and exhibit enhanced resistance to interference from the extracellular environment. Our proposed system holds the potential to enable the precise detection of intracellular substances and optimize the existing model of the electrode system for intracellular signal detection, thereby spearheading advancements in single-cell analysis.
Collapse
Affiliation(s)
- Qingda Xu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Ye Xi
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Longchun Wang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Mengfei Xu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Tao Ruan
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Zhiyuan Du
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Chunpeng Jiang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Jiawei Cao
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Xiantao Zhu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Xiaolin Wang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Bin Yang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Jingquan Liu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China.
| |
Collapse
|