1
|
Fu H, Guo Y, Gao W, Lou S, Chu PK, Sheng Z. Ultra-high sensitivity weak magnetic field detecting magnetic fluid surface plasmon resonance sensor based on a single-hole fiber. OPTICS EXPRESS 2024; 32:15025-15040. [PMID: 38859163 DOI: 10.1364/oe.520047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 03/22/2024] [Indexed: 06/12/2024]
Abstract
An ultra-high sensitivity weak magnetic field detecting magnetic fluid surface plasmon resonance (SPR) sensor based on a single-hole fiber (SHF) is proposed for detecting weak magnetic fields. The sensor is constructed with a single-hole fiber in which an exclusive air hole in the cladding is embedded with a metal wire and filled with a magnetic fluid (MF) to enhance the magnetic field sensitivity. The effects of the structural parameters, embedded metals, and refractive index difference between the core and cladding on the magnetic field sensitivity and peak loss are investigated and optimized. The sensitivity, resolution, figure of merit (FOM), and other characteristics of the sensor are analyzed systematically. The numerical results reveal a maximum magnetic field sensitivity of 451,000 pm/mT and FOM of 15.03 mT-1. The ultra-high magnetic field sensitivity renders the sensor capable of detecting weak magnetic fields at the pT level for the first time, in addition to a detection range from 3.5 mT to 17 mT. The SHF-SPR magnetic field sensor featuring high accuracy, simple structure, and ease of filling has immense potential in applications such as mineral resource exploration as well as geological and environmental assessment.
Collapse
|
2
|
Zhang Y, Ma X, Xu B, Li J, Chen H, Kang J, Zhao C, Jin S. All-solid highly sensitive fiber-tip magnetic field sensor based on a Fabry-Perot interferometer with a breakpoint structure. OPTICS LETTERS 2024; 49:2197-2200. [PMID: 38621110 DOI: 10.1364/ol.521138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 03/22/2024] [Indexed: 04/17/2024]
Abstract
An all-solid fiber-tip Fabry-Perot interferometer (FPI) coated with a nickel film is proposed and experimentally verified for magnetic field sensing with high sensitivity. It is fabricated by splicing a segment of a thin-wall capillary tube to a standard single-mode fiber (SMF), then inserting a tiny segment of fiber with a smaller diameter into the capillary tube, and creating an ultra-narrow air-gap at the SMF end to form an FPI. When the device is exposed to magnetic field, the capillary tube is strained due to the magnetostrictive effect of the nickel film coated on its outer surface. In addition, owing to the unique breakpoint sensitivity-enhancement structure of the air-gap FPI, the elongation of the capillary tube whose length is over 100 times longer than the air-gap width is entirely transferred to the cavity length change of the FPI, and the sensor is extremely sensitive to the magnetic field as proved by our experiments, achieving a high sensitivity of up to 2.236 nm/mT for a linear magnetic field range from 40 to 60 mT, as well as a low-temperature cross-sensitivity of 56 µT/°C. The all-solid stable structure, compact size (total length of ∼3.0 mm), and reflective working mode with high magnetic field sensitivity indicate that this sensor has good application prospects.
Collapse
|
3
|
Wang R, Yang P, Huang D, Bao G, Zhang W. Atom-based optical polarization modulator. OPTICS EXPRESS 2024; 32:7583-7593. [PMID: 38439436 DOI: 10.1364/oe.514173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 02/07/2024] [Indexed: 03/06/2024]
Abstract
In this work, we employ 87Rb atoms as rotation media to manipulate the polarization of optical fields in both magnetic and magnetic-free environments. Employing the nonlinear magneto-optical rotation mechanism, we achieve a state-of-the-art magneto-optical rotation coefficient of 1.74×108 rad⋅T-1⋅m-1 which is four orders of magnitude higher than commonly employed materials. Additionally, in a magnetic-free environment, we achieve all-optical cross-polarization modulation between the pump and probe light via Rb atoms. The nonlinear magneto-optical rotation configuration introduces inventive techniques for a new type of magneto-optical modulator while the all-optical configuration paves the way for exploring photonic integrated circuit (PIC) devices free from disruptions caused by electrical or magnetic crosstalk.
Collapse
|
4
|
Žurauskienė N. Engineering of Advanced Materials for High Magnetic Field Sensing: A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:2939. [PMID: 36991646 PMCID: PMC10059877 DOI: 10.3390/s23062939] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 03/04/2023] [Accepted: 03/05/2023] [Indexed: 06/19/2023]
Abstract
Advanced scientific and industrial equipment requires magnetic field sensors with decreased dimensions while keeping high sensitivity in a wide range of magnetic fields and temperatures. However, there is a lack of commercial sensors for measurements of high magnetic fields, from ∼1 T up to megagauss. Therefore, the search for advanced materials and the engineering of nanostructures exhibiting extraordinary properties or new phenomena for high magnetic field sensing applications is of great importance. The main focus of this review is the investigation of thin films, nanostructures and two-dimensional (2D) materials exhibiting non-saturating magnetoresistance up to high magnetic fields. Results of the review showed how tuning of the nanostructure and chemical composition of thin polycrystalline ferromagnetic oxide films (manganites) can result in a remarkable colossal magnetoresistance up to megagauss. Moreover, by introducing some structural disorder in different classes of materials, such as non-stoichiometric silver chalcogenides, narrow band gap semiconductors, and 2D materials such as graphene and transition metal dichalcogenides, the possibility to increase the linear magnetoresistive response range up to very strong magnetic fields (50 T and more) and over a large range of temperatures was demonstrated. Approaches for the tailoring of the magnetoresistive properties of these materials and nanostructures for high magnetic field sensor applications were discussed and future perspectives were outlined.
Collapse
Affiliation(s)
- Nerija Žurauskienė
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania;
- Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania
| |
Collapse
|
5
|
Sakowicz B, Kamiński M, Dudek M, Kurzych AT, Jaroszewicz LR. Post-Processing of Raw Data Recorded Continuously Using a FORS-Fibre-Optic Rotational Seismograph. SENSORS (BASEL, SWITZERLAND) 2022; 22:8673. [PMID: 36433269 PMCID: PMC9695366 DOI: 10.3390/s22228673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/07/2022] [Accepted: 11/08/2022] [Indexed: 06/16/2023]
Abstract
Modern optoelectronic devices use the advantage of digital systems for data processing aimed at delivering reliable information. However, since commonly used DACs have limited accuracy, some artefacts can be observed in data streams, especially in systems designed for continuous, long-term process monitoring. In this paper, the authors' experience with data enhancement using a fibre-optic rotational seismograph (FORS) operating in a closed-loop mode is presented and discussed. Generally, two kinds of enhancement are described. The first one uses suitable filtering techniques adequate for FORS noise investigation, as well as a suitable data resampling method for transmitted data file size reduction. The second one relates to the artefacts observed during data recording in real time. The recording starting point is triggered when the detected signal exceeds a middle signal level and, therefore, the existence of artefacts generally disturbs the recording process. Although the artefacts are easily recognised by human eyes even at first sight, their automatic elimination is not so easy. In this paper, the authors propose a new concept of signal filtering to solve the above problem.
Collapse
Affiliation(s)
- Bartosz Sakowicz
- Department of Microelectronics and Computer Science, Lodz University of Technology, 221 Wólczanska St., 93-005 Lodz, Poland
| | - Marek Kamiński
- Department of Microelectronics and Computer Science, Lodz University of Technology, 221 Wólczanska St., 93-005 Lodz, Poland
| | - Michał Dudek
- Institute of Applied Physics, Military University of Technology, 2 gen. Sylwestra Kaliskiego St., 00-908 Warsaw, Poland
- Elproma Elektronika Sp. z o. o., 2A Duńska St., 05-152 Czosnow, Poland
| | - Anna T. Kurzych
- Institute of Applied Physics, Military University of Technology, 2 gen. Sylwestra Kaliskiego St., 00-908 Warsaw, Poland
- Elproma Elektronika Sp. z o. o., 2A Duńska St., 05-152 Czosnow, Poland
| | - Leszek R. Jaroszewicz
- Institute of Applied Physics, Military University of Technology, 2 gen. Sylwestra Kaliskiego St., 00-908 Warsaw, Poland
- Elproma Elektronika Sp. z o. o., 2A Duńska St., 05-152 Czosnow, Poland
| |
Collapse
|
6
|
Zhou S, Tang H, Pan B, Zhang W. Abnormal handling mechanism and improvement measures of optical DC current transformer in smart grid environment. PeerJ Comput Sci 2022; 8:e1132. [PMID: 36426256 PMCID: PMC9680881 DOI: 10.7717/peerj-cs.1132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 09/23/2022] [Indexed: 06/16/2023]
Abstract
An optical DC current transformer anomaly handling mechanism is proposed to address the problem that the conventional DC current transformer anomaly handling mechanism cannot compensate for the defect of capacitor anomaly blocking. First, the implementation principle, modulation loop, demodulation method and its anomaly warning mechanism of the sine-wave modulated all-fibre-optic current transformer (FOCT) are investigated, and the effects of light source intensity and modulation voltage on current decoding are explained. The modulation loop is then simulated and modelled and a FOCT anomaly handling mechanism is proposed based on the Bessel function with real-time dynamic current compensation for small changes in modulation depth. Finally, an integrated dynamic test system for DC current transformers and DC protection is designed, and the actual system operation and fault model is established using the RTDS simulation system. The experiments demonstrate that the proposed FOCT anomaly handling and improvement measures can effectively improve the transient performance of FOCT, and at the same time provide a complete set of testing means for the engineering application and later upgrade and replacement of FOCT.
Collapse
Affiliation(s)
- Shihao Zhou
- Electric Power Research Institute of State Grid Jiangxi Electric Power Co., Ltd, Nanchang, Jiangxi, China
| | - Hansong Tang
- Jiangsu LingChuang Electric Automation Co., Ltd, Zhenjiang, Jiangsu, China
| | - Benren Pan
- Electric Power Research Institute of State Grid Jiangxi Electric Power Co., Ltd, Nanchang, Jiangxi, China
| | - Wei Zhang
- Jiangsu LingChuang Electric Automation Co., Ltd, Zhenjiang, Jiangsu, China
| |
Collapse
|
7
|
Wu J, Zhang X, Chen L. Research on the Dual Modulation of All-Fiber Optic Current Sensor. SENSORS 2022; 22:s22020430. [PMID: 35062391 PMCID: PMC8781253 DOI: 10.3390/s22020430] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 12/31/2021] [Accepted: 01/01/2022] [Indexed: 02/01/2023]
Abstract
Acousto-optic modulator (AOM) and electro-optical modulator (EOM) are applied to realize the all-fiber current sensor with a pulsed light source. The pulsed light is realized by amplitude modulation with AOM. The reflected interferometer current sensor is constructed by the mirror and phase modulation with EOM to improve the anti-interference ability. A correlation demodulation algorithm is applied for data processing. The influence of the modulation frequency and duty cycle of AOM on the optical system is determined by modeling and experiment. The duty cycle is the main factor affecting the normalized scale factor of the system. The modulation frequency mainly affects the output amplitude of the correlation demodulation and the system signal-to-noise ratio. The frequency multiplication factor links AOM and EOM, primarily affecting the ratio error. When the frequency multiplication factor is equal to the duty cycle of AOM and it is an integer multiple of 0.1, the ratio error of the system is less than 1.8% and the sensitivity and the resolution of AFOCS are 0.01063 mV/mA and 3 mA, respectively. The measurement range of AFOCS is from 11 mA to 196.62 A, which is excellent enough to meet the practical requirements for microcurrent measurement.
Collapse
|