1
|
Wang Z, Ding Y, Yuan W, Chen H, Chen W, Chen C. Active Claw-Shaped Dry Electrodes for EEG Measurement in Hair Areas. Bioengineering (Basel) 2024; 11:276. [PMID: 38534550 DOI: 10.3390/bioengineering11030276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 03/01/2024] [Accepted: 03/07/2024] [Indexed: 03/28/2024] Open
Abstract
EEG, which can provide brain alteration information via recording the electrical activity of neurons in the cerebral cortex, has been widely used in neurophysiology. However, conventional wet electrodes in EEG monitoring typically suffer from inherent limitations, including the requirement of skin pretreatment, the risk of superficial skin infections, and signal performance deterioration that may occur over time due to the air drying of the conductive gel. Although the emergence of dry electrodes has overcome these shortcomings, their electrode-skin contact impedance is significantly high and unstable, especially in hair-covered areas. To address the above problems, an active claw-shaped dry electrode is designed, moving from electrode morphological design, slurry preparation, and coating to active electrode circuit design. The active claw-shaped dry electrode, which consists of a claw-shaped electrode and active electrode circuit, is dedicated to offering a flexible solution for elevating electrode fittings on the scalp in hair-covered areas, reducing electrode-skin contact impedance and thus improving the quality of the acquired EEG signal. The performance of the proposed electrodes was verified by impedance, active electrode circuit, eyes open-closed, steady-state visually evoked potential (SSVEP), and anti-interference tests, based on EEG signal acquisition. Experimental results show that the proposed claw-shaped electrodes (without active circuit) can offer a better fit between the scalp and electrodes, with a low electrode-skin contact impedance (18.62 KΩ@1 Hz in the hairless region and 122.15 KΩ@1 Hz in the hair-covered region). In addition, with the active circuit, the signal-to-noise ratio (SNR) of the acquiring EEG signal was improved and power frequency interference was restrained, therefore, the proposed electrodes can yield an EEG signal quality comparable to wet electrodes.
Collapse
Affiliation(s)
- Zaihao Wang
- Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Yuhao Ding
- Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Wei Yuan
- Center for Intelligent Medical Equipment and Devices, Institute for Innovative Medical Devices, School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou 215123, China
| | - Hongyu Chen
- Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Wei Chen
- School of Biomedical Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Chen Chen
- Human Phenome Institute, Fudan University, Shanghai 201203, China
| |
Collapse
|
2
|
Fiedler P, Graichen U, Zimmer E, Haueisen J. Simultaneous Dry and Gel-Based High-Density Electroencephalography Recordings. SENSORS (BASEL, SWITZERLAND) 2023; 23:9745. [PMID: 38139591 PMCID: PMC10747542 DOI: 10.3390/s23249745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/06/2023] [Accepted: 12/08/2023] [Indexed: 12/24/2023]
Abstract
Evaluations of new dry, high-density EEG caps have only been performed so far with serial measurements and not with simultaneous (parallel) measurements. For a first comparison of gel-based and dry electrode performance in simultaneous high-density EEG measurements, we developed a new EEG cap comprising 64 gel-based and 64 dry electrodes and performed simultaneous measurements on ten volunteers. We analyzed electrode-skin impedances, resting state EEG, triggered eye blinks, and visual evoked potentials (VEPs). To overcome the issue of different electrode positions in the comparison of simultaneous measurements, we performed spatial frequency analysis of the simultaneously measured EEGs using spatial harmonic analysis (SPHARA). The impedances were 516 ± 429 kOhm (mean ± std) for the dry electrodes and 14 ± 8 kOhm for the gel-based electrodes. For the dry EEG electrodes, we obtained a channel reliability of 77%. We observed no differences between dry and gel-based recordings for the alpha peak frequency and the alpha power amplitude, as well as for the VEP peak amplitudes and latencies. For the VEP, the RMSD and the correlation coefficient between the gel-based and dry recordings were 1.7 ± 0.7 μV and 0.97 ± 0.03, respectively. We observed no differences in the cumulative power distributions of the spatial frequency components for the N75 and P100 VEP peaks. The differences for the N145 VEP peak were attributed to the different noise characteristics of gel-based and dry recordings. In conclusion, we provide evidence for the equivalence of simultaneous dry and gel-based high-density EEG measurements.
Collapse
Affiliation(s)
- Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Uwe Graichen
- Department of Biostatistics and Data Science, Karl Landsteiner University of Health Sciences, 3500 Krems an der Donau, Austria
| | - Ellen Zimmer
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| |
Collapse
|
3
|
Warsito IF, Komosar M, Bernhard MA, Fiedler P, Haueisen J. Flower electrodes for comfortable dry electroencephalography. Sci Rep 2023; 13:16589. [PMID: 37789022 PMCID: PMC10547758 DOI: 10.1038/s41598-023-42732-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 09/14/2023] [Indexed: 10/05/2023] Open
Abstract
Dry electroencephalography (EEG) electrodes provide rapid, gel-free, and easy EEG preparation, but with limited wearing comfort. We propose a novel dry electrode comprising multiple tilted pins in a flower-like arrangement. The novel Flower electrode increases wearing comfort and contact area while maintaining ease of use. In a study with 20 volunteers, we compare the performance of a novel 64-channel dry Flower electrode cap to a commercial dry Multipin electrode cap in sitting and supine positions. The wearing comfort of the Flower cap was rated as significantly improved both in sitting and supine positions. The channel reliability and average impedances of both electrode systems were comparable. Averaged VEP components showed no considerable differences in global field power amplitude and latency, as well as in signal-to-noise ratio and topography. No considerable differences were found in the power spectral density of the resting state EEGs between 1 and 40 Hz. Overall, our findings provide evidence for equivalent channel reliability and signal characteristics of the compared cap systems in the sitting and supine positions. The reliability, signal quality, and significantly improved wearing comfort of the Flower electrode allow new fields of applications for dry EEG in long-term monitoring, sensitive populations, and recording in supine position.
Collapse
Affiliation(s)
- Indhika Fauzhan Warsito
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Milana Komosar
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Maria Anne Bernhard
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany.
- Department of Neurology, Biomagnetic Center, University Hospital Jena, Jena, Germany.
| |
Collapse
|
4
|
Pontifex MB, Coffman CA. Validation of the g.tec Unicorn Hybrid Black wireless EEG system. Psychophysiology 2023; 60:e14320. [PMID: 37171024 DOI: 10.1111/psyp.14320] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 02/17/2023] [Accepted: 04/03/2023] [Indexed: 05/13/2023]
Abstract
Although dry and hybrid-style electrode technology has been well validated, systems utilizing these electrodes have not been widely adopted. One reason for this may be that the systems incorporating such technology present limitations that are fundamental to the EEG approach. The g.tec Unicorn Hybrid Black system, a low density Bluetooth EEG amplifier, however, attempts to address many of these limitations to allow greater flexibility to replicate methods used with traditional EEG amplifiers and extend them to more novel applications. The aim of the present investigation was to validate the g.tec Unicorn Hybrid Black amplifier to determine if it provides comparable data to a traditional laboratory-based system when no electrode preparation is utilized or if a saline-based solution is necessary to obtain sufficient signal quality. Stimulus-locked ERPs and EEG power spectrum data were concurrently recorded using both the Unicorn Hybrid Black amplifier and a traditional high-end laboratory-based low-impedance wired system. Findings suggest that the Unicorn Hybrid Black provides valid measures for investigations of frequency spectra even with no conductive solution applied. However, to obtain valid assessments of event-related brain potentials, it appears necessary to use a conductive solution for electrode preparation. This system appears well suited to allow for high-quality and flexible EEG measures available outside of traditional laboratory environments.
Collapse
Affiliation(s)
- Matthew B Pontifex
- Department of Kinesiology, Michigan State University, East Lansing, Michigan, USA
| | - Colt A Coffman
- Department of Kinesiology, Michigan State University, East Lansing, Michigan, USA
| |
Collapse
|
5
|
Gwon D, Won K, Song M, Nam CS, Jun SC, Ahn M. Review of public motor imagery and execution datasets in brain-computer interfaces. Front Hum Neurosci 2023; 17:1134869. [PMID: 37063105 PMCID: PMC10101208 DOI: 10.3389/fnhum.2023.1134869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Accepted: 03/10/2023] [Indexed: 04/18/2023] Open
Abstract
The demand for public datasets has increased as data-driven methodologies have been introduced in the field of brain-computer interfaces (BCIs). Indeed, many BCI datasets are available in various platforms or repositories on the web, and the studies that have employed these datasets appear to be increasing. Motor imagery is one of the significant control paradigms in the BCI field, and many datasets related to motor tasks are open to the public already. However, to the best of our knowledge, these studies have yet to investigate and evaluate the datasets, although data quality is essential for reliable results and the design of subject- or system-independent BCIs. In this study, we conducted a thorough investigation of motor imagery/execution EEG datasets recorded from healthy participants published over the past 13 years. The 25 datasets were collected from six repositories and subjected to a meta-analysis. In particular, we reviewed the specifications of the recording settings and experimental design, and evaluated the data quality measured by classification accuracy from standard algorithms such as Common Spatial Pattern (CSP) and Linear Discriminant Analysis (LDA) for comparison and compatibility across the datasets. As a result, we found that various stimulation types, such as text, figure, or arrow, were used to instruct subjects what to imagine and the length of each trial also differed, ranging from 2.5 to 29 s with a mean of 9.8 s. Typically, each trial consisted of multiple sections: pre-rest (2.38 s), imagination ready (1.64 s), imagination (4.26 s, ranging from 1 to 10 s), the post-rest (3.38 s). In a meta-analysis of the total of 861 sessions from all datasets, the mean classification accuracy of the two-class (left-hand vs. right-hand motor imagery) problem was 66.53%, and the population of the BCI poor performers, those who are unable to reach proficiency in using a BCI system, was 36.27% according to the estimated accuracy distribution. Further, we analyzed the CSP features and found that each dataset forms a cluster, and some datasets overlap in the feature space, indicating a greater similarity among them. Finally, we checked the minimal essential information (continuous signals, event type/latency, and channel information) that should be included in the datasets for convenient use, and found that only 71% of the datasets met those criteria. Our attempts to evaluate and compare the public datasets are timely, and these results will contribute to understanding the dataset's quality and recording settings as well as the use of using public datasets for future work on BCIs.
Collapse
Affiliation(s)
- Daeun Gwon
- Department of Computer Science and Electrical Engineering, Handong Global University, Pohang, Republic of Korea
| | - Kyungho Won
- School of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju, Republic of Korea
| | - Minseok Song
- Department of Computer Science and Electrical Engineering, Handong Global University, Pohang, Republic of Korea
| | - Chang S. Nam
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, NC, United States
- Department of Industrial and Management Systems Engineering, Kyung Hee University, Yongin-si, Republic of Korea
| | - Sung Chan Jun
- School of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju, Republic of Korea
- AI Graudate School, Gwangju Institute of Science and Technology, Gwangju, Republic of Korea
| | - Minkyu Ahn
- Department of Computer Science and Electrical Engineering, Handong Global University, Pohang, Republic of Korea
- School of Computer Science and Electrical Engineering, Handong Global University, Pohang, Republic of Korea
| |
Collapse
|
6
|
Baum U, Kühn F, Lichters M, Baum AK, Deike R, Hinrichs H, Neumann T. Neurological Outpatients Prefer EEG Home-Monitoring over Inpatient Monitoring-An Analysis Based on the UTAUT Model. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:13202. [PMID: 36293783 PMCID: PMC9603390 DOI: 10.3390/ijerph192013202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/07/2022] [Accepted: 10/09/2022] [Indexed: 06/16/2023]
Abstract
Home monitoring examinations offer diagnostic and economic advantages compared to inpatient monitoring. In addition, these technical solutions support the preservation of health care in rural areas in the absence of local care providers. The acceptance of patients is crucial for the implementation of home monitoring concepts. The present research assesses the preference for a health service that is to be introduced, namely an EEG home-monitoring of neurological outpatients-using a mobile, dry-electrode EEG (electroencephalography) system-in comparison to the traditional long-time EEG examination in a hospital. Results of a representative study for Germany (n = 421) reveal a preference for home monitoring. Importantly, this preference is partially driven by a video explaining the home monitoring system. We subsequently analyzed factors that influence the behavioral intention (BI) to use the new EEG system, drawing on an extended Unified Theory of Acceptance and Use of Technology (UTAUT) model. The strongest positive predictor of BI is the belief that EEG home-monitoring will improve health quality, while computer anxiety and effort expectancy represent the strongest barriers. Furthermore, we find the UTAUT model's behavioral intention construct to predict the patients' decision for or against home monitoring more strongly than any other patient's characteristic such as gender, health condition, or age, underlying the model's usefulness.
Collapse
Affiliation(s)
- Ulrike Baum
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Frauke Kühn
- Institute for Sensory and Innovation Research (ISI GmbH), Ascherberg 2, 37124 Rosdorf, Germany
| | - Marcel Lichters
- Chair of Marketing and Retailing, Faculty of Economics and Business Administration, Chemnitz University of Technology, Reichenhainer Straße 39, 09126 Chemnitz, Germany
| | - Anne-Katrin Baum
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Renate Deike
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Hermann Hinrichs
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
- Leibniz Institute for Neurobiology, Brenneckestraße 6, 39118 Magdeburg, Germany
- Center for Behavioral Brain Sciences (CBBS), Universitätsplatz 2, 39106 Magdeburg, Germany
| | - Thomas Neumann
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
- Chair in Health Services Research, School of Life Sciences, University of Siegen, Am Eichenhang 50, 57076 Siegen, Germany
- Chair in Empirical Economics, Otto-von-Guericke-University Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany
- Research Campus STIMULATE, Otto-von-Guericke-University Magdeburg, Sandtorstraße 23, 39106 Magdeburg, Germany
| |
Collapse
|
7
|
Me-Doped Ti-Me Intermetallic Thin Films Used for Dry Biopotential Electrodes: A Comparative Case Study. SENSORS 2021; 21:s21238143. [PMID: 34884159 PMCID: PMC8662430 DOI: 10.3390/s21238143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 11/26/2021] [Accepted: 12/01/2021] [Indexed: 11/23/2022]
Abstract
In a new era for digital health, dry electrodes for biopotential measurement enable the monitoring of essential vital functions outside of specialized healthcare centers. In this paper, a new type of nanostructured titanium-based thin film is proposed, revealing improved biopotential sensing performance and overcoming several of the limitations of conventional gel-based electrodes such as reusability, durability, biocompatibility, and comfort. The thin films were deposited on stainless steel (SS) discs and polyurethane (PU) substrates to be used as dry electrodes, for non-invasive monitoring of body surface biopotentials. Four different Ti–Me (Me = Al, Cu, Ag, or Au) metallic binary systems were prepared by magnetron sputtering. The morphology of the resulting Ti–Me systems was found to be dependent on the chemical composition of the films, specifically on the type and amount of Me. The existence of crystalline intermetallic phases or glassy amorphous structures also revealed a strong influence on the morphological features developed by the different systems. The electrodes were tested in an in-vivo study on 20 volunteers during sports activity, allowing study of the application-specific characteristics of the dry electrodes, based on Ti–Me intermetallic thin films, and evaluation of the impact of the electrode–skin impedance on biopotential sensing. The electrode–skin impedance results support the reusability and the high degree of reliability of the Ti–Me dry electrodes. The Ti–Al films revealed the least performance as biopotential electrodes, while the Ti–Au system provided excellent results very close to the Ag/AgCl reference electrodes.
Collapse
|