1
|
Rodríguez-Palma CE, Herráez-Hernández R, Campíns-Falcó P. A modified micro-solid phase extraction device for in-port elution and injection into portable liquid chromatography: A proof-of-concept study. J Chromatogr A 2023; 1705:464216. [PMID: 37480726 DOI: 10.1016/j.chroma.2023.464216] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 07/11/2023] [Accepted: 07/13/2023] [Indexed: 07/24/2023]
Abstract
A micro-solid phase extraction (micro-SPE) device packed with a C18 sorbent (10 mg) has been developed for the enrichment and purification of organic water pollutants prior to their analysis using a portable liquid chromatograph with a dual UV detector. To this end, the sorbent was immobilized at the inlet of a 4 mm syringe filter (0.20 µm), which was modified to reduce its internal volume. The filter was coupled to the needle of the chromatograph. After loading the sample and cleaning the sorbent for analyte purification, the device was installed into the injection port of the chromatograph, and the target compounds were desorbed and transferred directly to the chromatographic column with a small volume of organic solvent. Under optimized conditions, sample volumes as large as 50 mL could be processed with the micro-SPE device, while the analytes were desorbed with only 60 µL of methanol. As a result, efficient preconcentration could be reached, as demonstrated for different water contaminants, namely aclonifen, bifenox, tritosulfuron, triflusulfuron-methyl and caffeine. The proposed micro-SPE device was applied to the analysis of different types of water (river, well, sea, ditch and wastewater). The recoveries of the target compounds in samples ranged from 76 % to 109 %, which allowed their detection at low to sub µg/L levels. All operations were carried out manually, and thus, no additional laboratory instruments such as centrifuges, stirrers or evaporators were required. This proof-of-concept study shows that the proposed micro-SPE approach can be considered a reliable and effective option for the on-site analysis of pollutants in environmental water samples by portable liquid chromatography.
Collapse
Affiliation(s)
- C E Rodríguez-Palma
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| |
Collapse
|
2
|
Sartore DM, Vargas Medina DA, Bocelli MD, Jordan-Sinisterra M, Santos-Neto ÁJ, Lanças FM. Modern automated microextraction procedures for bioanalytical, environmental, and food analyses. J Sep Sci 2023; 46:e2300215. [PMID: 37232209 DOI: 10.1002/jssc.202300215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/02/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
Sample preparation frequently is considered the most critical stage of the analytical workflow. It affects the analytical throughput and costs; moreover, it is the primary source of error and possible sample contamination. To increase efficiency, productivity, and reliability, while minimizing costs and environmental impacts, miniaturization and automation of sample preparation are necessary. Nowadays, several types of liquid-phase and solid-phase microextractions are available, as well as different automatization strategies. Thus, this review summarizes recent developments in automated microextractions coupled with liquid chromatography, from 2016 to 2022. Therefore, outstanding technologies and their main outcomes, as well as miniaturization and automation of sample preparation, are critically analyzed. Focus is given to main microextraction automation strategies, such as flow techniques, robotic systems, and column-switching approaches, reviewing their applications to the determination of small organic molecules in biological, environmental, and food/beverage samples.
Collapse
Affiliation(s)
- Douglas M Sartore
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Deyber A Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcio D Bocelli
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcela Jordan-Sinisterra
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Álvaro J Santos-Neto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Fernando M Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| |
Collapse
|
3
|
Rodríguez-Palma CE, Herráez-Hernández R, Campíns-Falcó P. Study of the degradation of diphenyl-ether herbicides aclonifen and bifenox in different environmental waters. CHEMOSPHERE 2023; 336:139238. [PMID: 37330060 DOI: 10.1016/j.chemosphere.2023.139238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 06/13/2023] [Accepted: 06/14/2023] [Indexed: 06/19/2023]
Abstract
The degradation of the diphenyl-ether herbicides aclonifen (ACL) and bifenox (BF) in water samples has been studied under different laboratory conditions, using in-tube solid-phase microextraction (IT-SPME) coupled to capillary liquid chromatography (capLC). The working conditions were selected in order to detect also bifenox acid (BFA), a compound formed as a result of the hydroxylation of BF. Samples (4 mL) were processed without any previous treatment, which allowed the detection of the herbicides at low ppt levels. The effects of temperature, light and pH on the degradation of ACL and BF have been tested using standard solutions prepared in nanopure water. The effect of the sample matrix has been evaluated by analysing different environmental waters spiked with the herbicides, namely ditch water, river water and seawater. The kinetics of the degradation have been studied and the half-life times (t1/2) have been calculated. The results obtained have demonstrated that the sample matrix is the most important parameter affecting the degradation of the tested herbicides. The degradation of both ACL and BF was much faster in ditch and river water samples, where t1/2 values of only a few days were observed. However, both compounds showed a better stability in seawater samples, where they can persist for several months. In all matrices ACL was found to be more stable than BF. In samples where BF had been substantially degraded, BFA was also detected, although the stability of this compound was also limited. Other degradation products have been detected along the study.
Collapse
Affiliation(s)
- C E Rodríguez-Palma
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100, Burjassot, València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100, Burjassot, València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100, Burjassot, València, Spain
| |
Collapse
|
4
|
Kataoka H. In-tube solid-phase microextraction: Current trends and future perspectives. J Chromatogr A 2020; 1636:461787. [PMID: 33359971 DOI: 10.1016/j.chroma.2020.461787] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 01/01/2023]
Abstract
In-tube solid-phase microextraction (IT-SPME) was developed about 24 years ago as an effective sample preparation technique using an open tubular capillary column as an extraction device. IT-SPME is useful for micro-concentration, automated sample cleanup, and rapid online analysis, and can be used to determine the analytes in complex matrices simple sample processing methods such as direct sample injection or filtration. IT-SPME is usually performed in combination with high-performance liquid chromatography using an online column switching technology, in which the entire process from sample preparation to separation to data analysis is automated using the autosampler. Furthermore, IT-SPME minimizes the use of harmful organic solvents and is simple and labor-saving, making it a sustainable and environmentally friendly green analytical technique. Various operating systems and new sorbent materials have been developed to improve its extraction efficiency by, for example, enhancing its sorption capacity and selectivity. In addition, IT-SPME methods have been widely applied in environmental analysis, food analysis and bioanalysis. This review describes the present state of IT-SPME technology and summarizes its current trends and future perspectives, including method development and strategies to improve extraction efficiency.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan.
| |
Collapse
|
5
|
Ponce-Rodríguez HD, Verdú-Andrés J, Herráez-Hernández R, Campíns-Falcó P. Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 747:140966. [PMID: 32768766 DOI: 10.1016/j.scitotenv.2020.140966] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 07/12/2020] [Accepted: 07/12/2020] [Indexed: 06/11/2023]
Abstract
Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established for in place analysis. Methylxanthines: caffeine, theophylline and theobromine were selected as target analytes. A fast lab method based on IT-SPME coupled on line with capillary liquid chromatograph (CapLC) with diode array detection (DAD) was employed for comparative studies. IT-SPME and solid phase extraction were coupled off-line to NanoLC for improving instrumental parameters, mainly detection capacity and selectivity. IT-SPME or SPE/portable NanoLC based methods were superior in terms of chromatographic resolution and organic solvent consumption per sample, around 200 μL vs 10 mL for IT-SPME-CapLC-DAD. Limits of detection (LODs) obtained with the SPE/portable NanoLC were 2-10 ng/mL, which can be suitable for testing the presence of the analytes in several environmental waters in the field. As predictable, the lab method provided better LODs, between 0.1 and 0.5 ng/mL. Good linearity was achieved for both methods and precision was similar for them (≤7%). Both systems were tested for the analysis of real water samples with suitable results.
Collapse
Affiliation(s)
- H D Ponce-Rodríguez
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain; Departamento de Control Químico, Facultad de Química y Farmacia, Universidad Nacional Autónoma de Honduras, Ciudad Universitaria, Tegucigalpa, Honduras
| | - J Verdú-Andrés
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain.
| |
Collapse
|
6
|
Serra-Mora P, Herráez-Hernández R, Campíns-Falcó P. Minimizing the impact of sample preparation on analytical results: In-tube solid-phase microextraction coupled on-line to nano-liquid chromatography for the monitoring of tribenuron methyl in environmental waters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 721:137732. [PMID: 32172115 DOI: 10.1016/j.scitotenv.2020.137732] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 02/19/2020] [Accepted: 03/02/2020] [Indexed: 06/10/2023]
Abstract
The degradation kinetics and residual levels of the sulfonylurea herbicide tribenuron-methyl (TBM) in different environmental waters were studied using in tube-solid phase microextraction (IT-SPME) coupled on-line to nano-liquid chromatography (nanoLC) and UV diode array detection (DAD). This approach combines the high extraction efficiency of IT-SPME using polymeric coatings reinforced with metal oxide nanoparticles and the high sensitivity attainable by nanoLC, making possible the determination of TBM at low ppb levels (limit of detection, 0.25 ppb) without altering the sample matrix. The present study demonstrated that the preservation of the sample properties is essential to ensure accurate results at these concentration levels due to the high tendency of TBM to hydrolyze, particularly under the acidic conditions involved in most protocols used for sample treatment. The approach used in the present study was applied to evaluate the degradation of this herbicide under different conditions (UV radiation, pH), as well as to study the evolution of its concentration in different environmental waters, namely sea, river, ditch and transition waters. When the samples were exposed to identical conditions, significant differences in the degradation rate of TBM were found depending on the water matrix. The results obtained indicate that this herbicide can persist from several days to weeks depending on the type of water.
Collapse
Affiliation(s)
- P Serra-Mora
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| |
Collapse
|
7
|
Fused-silica capillary internally modified with nanostructured octadecyl silica for dynamic in-tube solid-phase microextraction of polycyclic aromatic hydrocarbons from aqueous media. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104672] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
8
|
Innovations in Extractive Phases for In-Tube Solid-Phase Microextraction Coupled to Miniaturized Liquid Chromatography: A Critical Review. Molecules 2020; 25:molecules25102460. [PMID: 32466305 PMCID: PMC7287690 DOI: 10.3390/molecules25102460] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 05/19/2020] [Accepted: 05/22/2020] [Indexed: 02/06/2023] Open
Abstract
Over the past years, a great effort has been devoted to the development of new sorbents that can be used to pack or to coat extractive capillaries for in-tube solid-phase microextraction (IT-SPME). Many of those efforts have been focused on the preparation of capillaries for miniaturized liquid chromatography (LC) due to the reduced availability of capillary columns with appropriate dimensions for this kind of system. Moreover, many of the extractive capillaries that have been used for IT-SPME so far are segments of open columns from the gas chromatography (GC) field, but the phase nature and dimensions are very limited. In particular, polar compounds barely interact with stationary GC phases. Capillary GC columns may also be unsuitable when highly selective extractions are needed. In this work, we provide an overview of the extractive capillaries that have been specifically developed for capillary LC (capLC) and nano LC (nanoLC) to enhance the overall performance of the IT-SPME, the chromatographic separation, and the detection. Different monolithic polymers, such as silica C18 and C8 polymers, molecularly imprinted polymers (MIPs), polymers functionalized with antibodies, and polymers reinforced with different types of carbon nanotubes, metal, and metal oxide nanoparticles (including magnetic nanoparticles), and restricted access materials (RAMs) will be presented and critically discussed.
Collapse
|
9
|
Serra-Mora P, Herráez-Hernández R, Campíns-Falcó P. Bimodal copper oxide nanoparticles doped phase for the extraction of highly polar compounds by in-tube solid-phase microextraction coupled on-line to nano-liquid chromatography. J Chromatogr A 2020; 1617:460819. [DOI: 10.1016/j.chroma.2019.460819] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 11/25/2019] [Accepted: 12/18/2019] [Indexed: 10/25/2022]
|
10
|
Exploring New Extractive Phases for In-Tube Solid Phase Microextraction Coupled to Miniaturized Liquid Chromatography. SEPARATIONS 2019. [DOI: 10.3390/separations6010012] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
In-tube solid-phase microextraction (IT-SPME) coupled on-line to miniaturized liquid chromatography (LC) has emerged as a powerful tool to address a variety of analytical problems. However, in order to expand its applicability, the development of new sorbents that enhance the efficiency and specificity of the extraction is highly desirable. In this respect, the employment of capillary columns coated with sorbents functionalized with nanoparticles (NPs) replacing the loop of the injection valve (in-valve IT-SPME) is one of the most attractive options. In this work, polymers of tetraethyl orthosilicate (TEOS) and trimethoxyethylsilane (MTEOS) modified with SiO2 and TiO2 NPs have been synthetized and used for the extraction of a variety of water pollutants, using both Capillary-LC and Nano-LC. Compounds with different chemical structures and polarities such as the artificial sweetener saccharine, the polycyclic aromatic hydrocarbons (PAHs) naphthalene and fluoranthene, and some phenylurea and organophosphorous herbicides have been used as target analytes. The extraction efficiencies found with the synthetized capillaries have been compared to those obtained with commercially available capillaries coated with polydiphenyl-polydimethylsiloxane (PDMS), nitroterephthalic acid modified polyetilenglicol (FFAP), and polystyrene-divinylbenzene (PS-DVB) phases. The results obtained in this preliminary study showed that, although PS-DVB phase has the strongest affinity for compounds with two or more aromatic rings, the extraction with TEOS-MTEOS coatings modified with NPs is the best option for a majority of the tested compounds. Examples of application are given.
Collapse
|
11
|
Jornet-Martínez N, Ortega-Sierra A, Verdú-Andrés J, Herráez-Hernández R, Campíns-Falcó P. Analysis of Contact Traces of Cannabis by In-Tube Solid-Phase Microextraction Coupled to Nanoliquid Chromatography. Molecules 2018; 23:molecules23092359. [PMID: 30223565 PMCID: PMC6225310 DOI: 10.3390/molecules23092359] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Revised: 09/06/2018] [Accepted: 09/13/2018] [Indexed: 01/08/2023] Open
Abstract
Because of its inherent qualities, in-tube solid-phase microextraction (IT-SPME) coupled on-line to nanoliquid chromatography (nanoLC) can be a very powerful tool to address the new challenges of analytical laboratories such as the analysis of traces of complex samples. This is the case of the detection of contact traces of drugs, especially cannabis. The main difficulties encountered in the analysis of traces of cannabis plants on surfaces are the low amount of sample available (typically < 1 mg), the complexity of the matrix, and the low percentages of cannabinoic compounds in the samples. In this work, a procedure is described for the detection of residues of cannabis on different surfaces based on the responses obtained by IT-SPME coupled to nanoLC with UV diode array detection (DAD) for the cannabinoids Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), and cannabinol (CBN); the proposed conditions can also be applied for quantitative purposes through the measurement of the percentage of THC, the most abundant cannabinoid in plants. The method is based on collecting the suspected drug samples with cotton swabs, followed by the extraction of the target compounds by ultrasound assisted extraction. The extracts are then separated and processed by IT-SPME-nanoLC. The proposed approach has been applied to the detection of traces of cannabis in different kind of items (plastic bags, office paper, aluminum foil, cotton cloths, and hand skin). Sample amounts as low as 0.08 mg have been collected and analysed for THC. The selectivity and effect of the storage conditions on the levels of THC have also been evaluated. The percentages of THC in the samples typically ranged from 0.6% to 2.8%, which means that amounts of this compound as low as 1–2 µg were adequately detected and quantified. For the first time, the reliability of IT-SPME-nanoLC for the analysis of complex matrices such as cannabis plant extracts has been demonstrated.
Collapse
Affiliation(s)
- Neus Jornet-Martínez
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Adrián Ortega-Sierra
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Jorge Verdú-Andrés
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Rosa Herráez-Hernández
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| | - Pilar Campíns-Falcó
- MINTOTA Research Group, Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain.
| |
Collapse
|