1
|
Alawadi M, Fakhari AR, Bayatloo MR, Nojavan S. Carboxymethylated maltodextrin as a chiral selector for the separation of some basic drug enantiomers using capillary electrophoresis. J Chromatogr A 2023; 1708:464335. [PMID: 37696127 DOI: 10.1016/j.chroma.2023.464335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 08/17/2023] [Accepted: 08/26/2023] [Indexed: 09/13/2023]
Abstract
In this work, carboxymethylated maltodextrin (Cm-MD) was successfully synthesized as an efficient anionic chiral selector and applied for the enantiomer separation of some basic drugs including tramadol, venlafaxine, verapamil, hydroxyzine, citalopram, fluoxetine, and amlodipine by capillary electrophoresis (CE). The synthesized chiral selector was characterized by the nuclear magnetic resonance and Fourier transform infrared spectrophotometry. Under the optimized Cm-MD modified CE conditions (background electrolyte: phosphate buffer (pH 5.0, 50 mM) containing 5% (w/v) Cm-MD; applied voltage: 20 kV; and capillary column temperature: 25 °C), successful enantiomer separation of all studied chiral drugs were observed. By comparison of Cm-MD and MD for enantiomer separation of the model drugs, it was revealed that Cm-MD exhibits a higher resolution in comparison to the MD modified CE. This enhanced resolution could be attributed to the electrostatic interactions between the cationic drugs and anionic Cm-MD and opposite direction mobility of the host-guest complex relative to the chiral analyte. The optimized Cm-MD modified CE method was successfully used for the assay of the enantiomers of citalopram and venlafaxine in commercial tablets. The proposed method showed the linear range of 5.0-150.0 mg/L and 10.0-150.0 mg/L for both enantiomers of citalopram and venlafaxine, respectively. The limits of quantification were 5.0 and 10.0 mg/L for the enantiomers of citalopram and venlafaxine, respectively. The limit of detection for all enantiomers was found to be < 3.0 mg/L. Intra- and inter-day RSDs (n = 4) were less than 9.7%. The relative errors were less than 9.4% for all enantiomers. The obtained results in this research show that Cm-MD as a new, efficient and inexpensive chiral selector can be used for enantiomer separation of basic drugs using the CE technique.
Collapse
Affiliation(s)
- Mustafa Alawadi
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, Tehran, Iran
| | - Ali Reza Fakhari
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, Tehran, Iran.
| | - Mohammad Reza Bayatloo
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, Tehran, Iran
| | - Saeed Nojavan
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, Tehran, Iran.
| |
Collapse
|
2
|
Aredes RS, Lima IDP, Faillace AP, Madriaga VGC, Lima TDM, Vaz FAS, Marques FFDC, Duarte LM. From capillaries to microchips, green electrophoretic features for enantiomeric separations: A decade review (2013-2022). Electrophoresis 2023; 44:1471-1518. [PMID: 37667860 DOI: 10.1002/elps.202200178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 06/28/2023] [Accepted: 07/12/2023] [Indexed: 09/06/2023]
Abstract
Enantioseparation by the electromigration-based method is well-established and widely discussed in the literature. Electrophoretic strategies have been used to baseline resolve complex enantiomeric mixtures, typically using a selector substance into the background electrolyte (BGE) from capillaries to microchips. Along with developing new materials/substances for enantioseparations, it is the concern about the green analytical chemistry (GAC) principles for method development and application. This review article brings a last decade's update on the publications involving enantioseparation by electrophoresis for capillary and microchip systems. It also brings a critical discussion on GAC principles and new green metrics in the context of developing an enantioseparation method. Chemical and green features of native and modified cyclodextrins are discussed. Still, given the employment of greener substances, ionic liquids and deep-eutectic solvents are highlighted, and some new selectors are proposed. For all the mentioned selectors, green features about their production, application, and disposal are considered. Sample preparation and BGE composition in GAC perspective, as well as greener derivatization possibilities, were also addressed. Therefore, one of the goals of this review is to aid the electrophoretic researchers to look where they have not.
Collapse
Affiliation(s)
- Rafaella S Aredes
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Isabela de P Lima
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Amanda P Faillace
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Vinicius G C Madriaga
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Thiago de M Lima
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Fernando A S Vaz
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Flávia F de C Marques
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Lucas M Duarte
- Programa, de Pós-Graduação em Química, Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| |
Collapse
|
3
|
Recent Advances on Chiral Mobile Phase Additives: A Critical Review. JOURNAL OF ANALYSIS AND TESTING 2022. [DOI: 10.1007/s41664-022-00222-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
4
|
Application of Experimental Design Methodologies in the Enantioseparation of Pharmaceuticals by Capillary Electrophoresis: A Review. Molecules 2021; 26:molecules26154681. [PMID: 34361834 PMCID: PMC8348688 DOI: 10.3390/molecules26154681] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 07/28/2021] [Accepted: 07/29/2021] [Indexed: 12/12/2022] Open
Abstract
Chirality is one of the major issues in pharmaceutical research and industry. Capillary electrophoresis (CE) is an interesting alternative to the more frequently used chromatographic techniques in the enantioseparation of pharmaceuticals, and is used for the determination of enantiomeric ratio, enantiomeric purity, and in pharmacokinetic studies. Traditionally, optimization of CE methods is performed using a univariate one factor at a time (OFAT) approach; however, this strategy does not allow for the evaluation of interactions between experimental factors, which may result in ineffective method development and optimization. In the last two decades, Design of Experiments (DoE) has been frequently employed to better understand the multidimensional effects and interactions of the input factors on the output responses of analytical CE methods. DoE can be divided into two types: screening and optimization designs. Furthermore, using Quality by Design (QbD) methodology to develop CE-based enantioselective techniques is becoming increasingly popular. The review presents the current use of DoE methodologies in CE-based enantioresolution method development and provides an overview of DoE applications in the optimization and validation of CE enantioselective procedures in the last 25 years. Moreover, a critical perspective on how different DoE strategies can aid in the optimization of enantioseparation procedures is presented.
Collapse
|
5
|
El Deeb S, Silva CF, Junior CSN, Hanafi RS, Borges KB. Chiral Capillary Electrokinetic Chromatography: Principle and Applications, Detection and Identification, Design of Experiment, and Exploration of Chiral Recognition Using Molecular Modeling. Molecules 2021; 26:2841. [PMID: 34064769 PMCID: PMC8151978 DOI: 10.3390/molecules26102841] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 05/04/2021] [Accepted: 05/07/2021] [Indexed: 12/19/2022] Open
Abstract
This work reviews the literature of chiral capillary electrokinetic chromatography from January 2016 to March 2021. This is done to explore the state-of-the-art approach and recent developments carried out in this field. The separation principle of the technique is described and supported with simple graphical illustrations, showing migration under normal and reversed polarity modes of the separation voltage. The most relevant applications of the technique for enantioseparation of drugs and other enantiomeric molecules in different fields using chiral selectors in single, dual, or multiple systems are highlighted. Measures to improve the detection sensitivity of chiral capillary electrokinetic chromatography with UV detector are discussed, and the alternative aspects are explored, besides special emphases to hyphenation compatibility to mass spectrometry. Partial filling and counter migration techniques are described. Indirect identification of the separated enantiomers and the determination of enantiomeric migration order are mentioned. The application of Quality by Design principles to facilitate method development, optimization, and validation is presented. The elucidation and explanation of chiral recognition in molecular bases are discussed with special focus on the role of molecular modeling.
Collapse
Affiliation(s)
- Sami El Deeb
- Institute of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, 38106 Braunschweig, Germany
| | - Camilla Fonseca Silva
- Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei (UFSJ), Praça Dom Helvécio 74, Fábricas, São João del-Rei 36301-160, Minas Gerais, Brazil; (C.F.S.); (C.S.N.J.); (K.B.B.)
| | - Clebio Soares Nascimento Junior
- Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei (UFSJ), Praça Dom Helvécio 74, Fábricas, São João del-Rei 36301-160, Minas Gerais, Brazil; (C.F.S.); (C.S.N.J.); (K.B.B.)
| | - Rasha Sayed Hanafi
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt;
| | - Keyller Bastos Borges
- Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei (UFSJ), Praça Dom Helvécio 74, Fábricas, São João del-Rei 36301-160, Minas Gerais, Brazil; (C.F.S.); (C.S.N.J.); (K.B.B.)
| |
Collapse
|
6
|
Perovani IS, Serpellone CO, de Oliveira ARM. An appraisal of experimental designs: Application to enantioselective capillary electromigration techniques. Electrophoresis 2021; 42:1726-1743. [PMID: 33544902 DOI: 10.1002/elps.202000334] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 01/29/2021] [Accepted: 01/31/2021] [Indexed: 02/06/2023]
Abstract
Enantioresolution processes are vital tools for investigating the enantioselectivities of chiral compounds. An analyst resolves to optimize enantioresolution conditions once they are determined. Generally, optimization is conducted by a one-factor-at-a-time (OFAT) approach. Although this approach may determine an adequate condition for the method, it does not often allow the estimation of the real optimum condition. Experimental designs are conducive for the optimization of enantioresolution methods via capillary electromigration techniques (CETs). They can efficiently extract information from the behavior of a method and enable the estimation of the real optimum condition. Furthermore, the application of the analytical quality by design (AQbD) approach to the development of CET-based enantioselective methods is a trend. This article (i) offers an overview of the application of experimental designs to the development of enantioselective methods from 2015 to mid-2020, (ii) reveals the experimental designs that are presently employed in CET-based enantioresolutions, and (iii) offers a critical point of view on how the different experimental designs can aid the optimization of enantioresolution processes by considering the method parameters.
Collapse
Affiliation(s)
- Icaro Salgado Perovani
- Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Sao Paulo, 14040-901, Brazil
| | - Carolina Oliveira Serpellone
- Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Sao Paulo, 14040-901, Brazil
| | - Anderson Rodrigo Moraes de Oliveira
- Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Sao Paulo, 14040-901, Brazil.,National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), UNESP, Institute of Chemistry, Araraquara, Sao Paulo, 14800-900, Brazil
| |
Collapse
|