Ertuğrul İF, Arslan HK. Investigation of four nickel titanium endodontic instruments, with cyclic fatigue resistance, scanning electron microscopy, and energy dispersive x-ray spectroscopy. Microsc Res Tech 2024. [PMID: 38988203 DOI: 10.1002/jemt.24655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 06/11/2024] [Accepted: 07/01/2024] [Indexed: 07/12/2024]
Abstract
The aim of this study was to compare of four different nickel-titanium (Ni-Ti) endodontic files and evaluate in terms of cyclic fatigue resistance and metallurgical properties. Four different type Ni-Ti root canal files Protaper Next X2 (PTN) (Dentsply Maillefer, Ballaigues, Switzerland), One Curve (OC) #25.06 (Micro Mega, Besancon, France), EndoPlus Flex Plus Gold X2 (EPG) (Turkuaz Dental, Denizli, Turkey), and EndoPlus Flex Plus Blue #25.06 (EPB) (Turkuaz Dental, Denizli, Turkey) files were tested for cyclic fatigue resistance (n = 20). During experiments artificial zirconia block canal was used. The artificial canal designed with curvature 60° and 5-mm radius. The number of cyclic to fracture (NCF) was noted. Fractured length (FL) parts of Ni-Ti files were recorded to assessment of fracture volumetric point. All fractured surfaces of Ni-Ti files were assessed by scanning electron microscope (SEM) to confirm the type of fractures. Descriptive evaluation become accomplished for the fundamental composition of units with the aid of using energy-dispersive x-ray spectroscopy (EDX). NCF data were evaluated via Bonferroni test with post hoc multiple comparison method. OC showed the highest NCF values (p < .05). The standardization of the study was confirmed as the FL of files was statistically similar in length (p > .05). SEM analysis confirmed that all scanned samples were fractured due to cyclic fatigue. EDX analysis confirmed that EPB established the poorest Ni content file. RESEARCH HIGHLIGHTS: The cyclic fatigue-related failure of One Curve was significantly more resistant than Protaper Next and EndoPlus files. Scanning electron microscopy images showed that One Curve and Protaper Next have round tips Energy dispersive x-ray spectroscopy showed that all four endodontic instruments mainly have Nickel and Titanium elements.
Collapse
Affiliation(s)
- İhsan Furkan Ertuğrul
- Department of Endodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Havva Kübra Arslan
- Department of Endodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| |
Collapse
|
2
|
MAHMOUD O, ALHIMAIRI S, SULTAN D, ALI A. Shaping Ability of Different Rotary and Reciprocating File Systems in Simulated S-Shaped Root Canals. Eur Endod J 2024; 9:114 - 123. [PMID: 38377107 PMCID: PMC10938361 DOI: 10.14744/eej.2023.93824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 09/20/2023] [Accepted: 10/25/2023] [Indexed: 02/22/2024] Open
Abstract
OBJECTIVE This study aimed to examine the shaping ability of six rotary and reciprocating file systems, as well as hybrid techniques in simulated S-shaped root canals. METHODS A hundred and twenty S-shaped radiopaque thermosetting epoxy resin blocks were grouped according to the system used for biomechanical preparation. Six groups of 15 canals each were prepared using TruNatomy, Procodile, VDW Rotate, Hyflex CM, OneCurve, and WaveOne Gold, respectively. Two additional hybrid (Procodile/Hyflex CM and Procodile/TruNatomy) groups (n=15 each) were added after evaluating the results of individual systems. All canals were enlarged to 0.25 mm apically. Canal transportation, centering ability, diameter increase, and iatrogenic errors were assessed by superimposed pre-operative and post-operative images. AutoCAD was used for data analysis. All groups were statistically compared with analysis of variance and Tukey honest significant difference test (p<0.05). RESULTS Hyflex CM resulted in the most conservative diameter increase in all thirds (coronal, middle, and apical; p<0.001). Procodile showed the best (p<0.001) centering ability in the coronal and middle thirds, while TruNatomy resulted in the least canal transportation and most centering preparation in the apical third (p<0.001). Hybridisation of Procodile and Hyflex CM produced the least canal transportation and best centering ability in the middle third (p<0.001). No instrument breakage occurred, and no ledge, elbow, or apical zip formation was observed during canal preparation. CONCLUSION Hybridisation of Procodile and Hyflex CM showed remarkable results in preserving the canal diameter in all thirds and resulted in the least canal transportation and best centering ability in the middle third of the canal. However, when treatment cost and duration limit the clinical applicability of the hybrid technique, clinicians can use a single file system (Hyflex CM or TruNatomy) since it shows satisfactory results in all parameters when compared with a hybrid system.
Collapse
Affiliation(s)
- Okba MAHMOUD
- Department of Clinical Sciences, Ajman University College of Dentistry, Ajman, UAE
- Center of Medical and Bio-allied Health Sciences Research, Ajman University, Ajman, UAE
| | - Sara ALHIMAIRI
- Department of Clinical Sciences, Ajman University College of Dentistry, Ajman, UAE
| | - Diana SULTAN
- Department of Clinical Sciences, Ajman University College of Dentistry, Ajman, UAE
| | - Ayah ALI
- Department of Clinical Sciences, Ajman University College of Dentistry, Ajman, UAE
| |
Collapse
|
3
|
Pedullà E, Canova FS, La Rosa GRM, Naaman A, Diemer F, Generali L, Nehme W. Influence of NiTi Wire Diameter on Cyclic and Torsional Fatigue Resistance of Different Heat-Treated Endodontic Instruments. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6568. [PMID: 36233910 PMCID: PMC9572814 DOI: 10.3390/ma15196568] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/14/2022] [Accepted: 09/19/2022] [Indexed: 06/16/2023]
Abstract
We compared the mechanical properties of 2Shape mini TS2 (Micro-Mega, Besançon, France) obtained from 1.0 diameter nickel-titanium (NiTi) wires and 2Shape TS2 from 1.2 diameter nickel-titanium (NiTi) wires differently thermally treated at room and body temperature. We used 120 NiTi TS2 1.0 and TS2 1.2 files made from controlled memory (CM) wire and T-wire (n = 10). Cyclic fatigue resistance was tested by recording the number of cycles to fracture (NCF) at room and body temperatures using a customized testing device. Maximum torque and angle of rotation at failure were recorded, according to ISO 3630-1. Data were analyzed by a two-way ANOVA (p < 0.05). The CM-wire files had significantly higher NCFs at both temperatures, independent of wire dimensions. Testing at body temperature negatively affected cyclic fatigue of all files. The 1.0-mm diameter T-wire instruments showed higher NCF than the 1.2-mm diameter, whereas no significant differences emerged between the two CM wires at either temperature. The maximum torque was not significantly different across files. The TS2 CM-wire files showed significantly higher angular rotation to fracture than T-wire files. The TS2 CM-wire prototypes showed higher cyclic fatigue resistance than T-wire prototypes, regardless of wire size, exhibiting suitable torsional properties. Torsional behavior appears to not be affected by NiTi wire size.
Collapse
Affiliation(s)
- Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Via Santa Sofia, 78, 95123 Catania, Italy
| | - Francesco Saverio Canova
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Via Santa Sofia, 78, 95123 Catania, Italy
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Via Santa Sofia, 78, 95123 Catania, Italy
| | - Alfred Naaman
- Endodontic Department, Saint Joseph University of Beirut, Rue de Damas P.O. Box 17-5208, Beirut 1104 2020, Lebanon
| | - Franck Diemer
- Restorative and Endodontic Department, CHU de Toulouse, University of Toulouse, 31013 Toulouse, France
- Clement Ader Institute, UMR CNRS 5312, 31400 Toulouse, France
| | - Luigi Generali
- Endodontic Section, Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), School of Dentistry, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Walid Nehme
- Endodontic Department, Saint Joseph University of Beirut, Rue de Damas P.O. Box 17-5208, Beirut 1104 2020, Lebanon
| |
Collapse
|
4
|
Pedullà E, Kharouf N, Caruso S, La Rosa GRM, Jmal H, Haikel Y, Mancino D. Torsional, Static and Dynamic Cyclic Fatigue Resistance of Reciprocating and Continuous Rotating NiTi Instruments. J Endod 2022; 48:1421-1427. [PMID: 35987386 DOI: 10.1016/j.joen.2022.08.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 07/14/2022] [Accepted: 08/10/2022] [Indexed: 11/17/2022]
Abstract
INTRODUCTION To evaluate torsional, dynamic and static cyclic fatigue resistance of the reciprocating One Reci (OR, Micromega, Besançon, France), WaveOne Gold (WOG, Dentsply Maillefer, Ballaigues, Switzerland), rotary One Curve (OC, MicroMega, Besançon, France) and ProTaper Next X2 (PTN X2, Dentsply Sirona, Ballaigues, Switzerland) instruments. METHODS A total of 120 NiTi instruments (n = 30) OR, WOG, OC and PTN X2 were used. Torque and rotation angle until failure under static torsion loading were measured according to the ISO 3630-1. Static and dynamic fatigue resistance was measured as the time to fracture (TTF) in an artificial stainless-steel canal with a 60° angle and 5-mm radius of curvature at intracanal temperature. The results were analyzed with one-way ANOVA and post-hoc Tukey tests. The alpha-type error was set at 5%. Fracture instruments from torsion and fatigue tests were examined with scanning electron microscope. RESULTS The OR showed higher static fatigue resistance and rotation angle at fracture than the WOG, OC and PTN X2 (P < .05). The WOG exhibited higher torsional resistance than the others (P < .05). Dynamic cyclic fatigue resistance tests had highest TTF than static for the PTN X2 and the WOG groups (P < .05). In the dynamic tests, the OR and WOG showed higher TTF than the OC and PTN X2 (P < .05). CONCLUSIONS Under these experimental condition, One Reci exhibited suitable mechanical properties with the highest cyclic fatigue resistance and angle of rotation among the tested instruments.
Collapse
Affiliation(s)
- Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy.
| | - Naji Kharouf
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| | - Simone Caruso
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Hamdi Jmal
- ICube Laboratory, UMR 7357 CNRS, Mechanics Department, University of Strasbourg, Strasbourg, France
| | - Youssef Haikel
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| | - Davide Mancino
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| |
Collapse
|
5
|
Rubio J, Zarzosa JI, Aranda S, Casino A, Pallarés A. A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study. J Clin Exp Dent 2022; 14:e560-e565. [PMID: 35912033 PMCID: PMC9328485 DOI: 10.4317/jced.59747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 06/06/2022] [Indexed: 11/15/2022] Open
Abstract
Background Mechanical preparation and the formation of space for adequate obturation are included in root canal shaping, but the complex root canal anatomy may be affect it. Manufacturers have created different alloys like M-Wire, Blue-Wire, Gold-Wire or R-phase. Objective: This investigation was performed to verify the null hypothesis that there were not significant differences between size 25 instruments ESP Files Thermoflex, Protaper Ultimate, Protaper Next, Blueshaper, One Curve and 2Shape about cyclic fatigue and length of broken fragments.
Material and Methods 180 new size 25 files of the systems investigated were selected (n=30). Files were used with Endo Mate DT endo motor with speed and torque recommended by manufacturers, holding the instruments with clamping mechanism, with passive adjustment, glycerine and without pressure in a stainless-steel block. The time was calculated in seconds until fracture. Number of fatigue cycles was determined as (Resistance (s) x Speed)/60. Separated fragment lengths were calculated with digital Vernier caliper. Statistical analysis was carried out with the SPSS 18 programme at a 95% confidence level, using Levene´s Test to compare variances, Welch’s Test to compare means, and Games-Howell´s Test to reveal differences between groups.
Results Levene’s Test determined no equal variances (P<0.05). Welch’s Test and ANOVA (P<0.05) showed significant differences in cyclic fatigue and separated fragment lengths. Games-Howell’s and Bonferroni´s Test established significant differences in multiple comparisons (P<0.05).
Conclusions ESP Files Thermoflex was superior in cyclic fatigue. About separated fragment lengths, ESP Files Thermoflex, Protaper Ultimate and Blueshaper obtained longer lengths. Key words:Cyclic fatigue, continuous movement, separated fragment lengths, rotary systems.
Collapse
Affiliation(s)
- Jorge Rubio
- Professors of the Master of Endodontics and Restorative Dentistry, Catholic University of Valencia
| | - José-Ignacio Zarzosa
- Professors of the Master of Endodontics and Restorative Dentistry, Catholic University of Valencia
| | - Susana Aranda
- Professors of the Master of Endodontics and Restorative Dentistry, Catholic University of Valencia
| | - Alberto Casino
- Professors of the Master of Endodontics and Restorative Dentistry, Catholic University of Valencia
| | - Antonio Pallarés
- Director of the Master of Endodontics and Restorative Dentistry, Catholic University of Valencia
| |
Collapse
|