1
|
Xue J, Jin S, Zhang H, Zou K, Sheng J, Tang J, Zhao W, Yang P, Tang L, Lv X, Lv L. A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance. Front Oncol 2023; 13:1143564. [PMID: 37152035 PMCID: PMC10155751 DOI: 10.3389/fonc.2023.1143564] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/24/2023] [Indexed: 05/09/2023] Open
Abstract
Purpose To evaluate the feasibility of using a simplified non-coplanar volumetric modulated arc therapy (NC-VMAT) and investigate its dosimetric advantages compared with intensity modulated radiation therapy (IMRT) and coplanar volumetric modulated arc therapy (C-VMAT) for hippocampal-avoidance whole brain radiation therapy (HA-WBRT). Methods Ten patients with brain metastase (BM) were included for HA-WBRT. Three treatment plans were generated for each case using IMRT, C-VMAT, and NC-VMAT, respectively. Results The dosimetric results of the three techniques complied roughly with the RTOG 0933 criteria. After dose normalization, the V30Gy of whole brain planned target volume (WB-PTV) in all the plans was controlled at 95%. Homogeneity index (HI) of WB-PTV was significantly reduced in NC-VMAT (0.249 ± 0.017) over IMRT (0.265 ± 0.020, p=0.005) and C-VMAT (0.261 ± 0.014, p=0.020). In terms of conformity index (CI), NC-VMAT could provide a value of 0.821 ± 0.010, which was significantly superior to IMRT (0.788 ± 0.019, p<0.001). According to D2% of WB-PTV, NC-VMAT could provide a value of 35.62 ± 0.37Gy, significantly superior to IMRT (36.43 ± 0.65Gy, p<0.001). According to D50% of WB-PTV, NC-VMAT can achieve the lowest value of 33.18 ± 0.29Gy, significantly different from IMRT (33.47 ± 0.43, p=0.034) and C-VMAT (33.58 ± 0.37, p=0.006). Regarding D2%, D98%, and Dmean of hippocampus, NC-VMAT could control them at 15.57 ± 0.18Gy, 8.37 ± 0.26Gy and 11.71 ± 0.48Gy, respectively. D2% and Dmean of hippocampus for NC-VMAT was significantly lower than IMRT (D2%: 16.07 ± 0.29Gy, p=0.001 Dmean: 12.18 ± 0.33Gy, p<0.001) and C-VMAT (D2%: 15.92 ± 0.37Gy, p=0.009 Dmean: 12.21 ± 0.54Gy, p<0.001). For other organs-at-risk (OARs), according to D2% of the right optic nerves and the right lenses, NC-VMAT had the lowest values of 31.86 ± 1.11Gy and 7.15 ± 0.31Gy, respectively, which were statistically different from the other two techniques. For other organs including eyes and optic chiasm, NC-VMAT could achieve the lowest doses, different from IMRT statistically. Conclusion The dosimetry of the three techniques for HA-WBRT could roughly comply with the proposals from RTOG 0933. After dose normalization (D95%=30Gy), NC-VMAT could significantly improve dose homogeneity and reduce the D50% in the brain. Besides, it can reduce the D2% of the hippocampus, optic nerves, and lens. With this approach, an efficient and straightforward plan was accomplished.
Collapse
Affiliation(s)
- Juan Xue
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Sunian Jin
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Hongtao Zhang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Kun Zou
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Junxiu Sheng
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Jinhai Tang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Wanying Zhao
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Ping Yang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Lufan Tang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Xiupeng Lv
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
- *Correspondence: Xiupeng Lv, ; Li Lv,
| | - Li Lv
- The Department of Pathology, Second Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
- *Correspondence: Xiupeng Lv, ; Li Lv,
| |
Collapse
|
2
|
Xu M, Cheng X, Cheng X, Lan X, Chen S, Ji J. Areas of breast tissue covered in cone beam breast CT imaging. Exp Ther Med 2017; 13:913-916. [PMID: 28450919 PMCID: PMC5403451 DOI: 10.3892/etm.2017.4092] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Accepted: 01/16/2017] [Indexed: 01/10/2023] Open
Abstract
The value of cone beam breast computed tomography (CBBCT) imaging on covered areas of breast tissue, which is the relation between imaging quality and CT dose were studied. Multi-energy spectrum was used to radiate same-size built-in calcifications and lump breast motifs under the condition of the same number of particles by utilizing the Monte Carlo-based GATE simulation software; breast motif images were restructured by using FBP restructuration algorithm to gain the distribution of radiation dose in the breast motif; radiation dose was calculated and signal-to-noise ratio (SNR) to define how quality factor M and dose efficiency η reflect the relations between radiation dose and imaging quality. Based on the comparison of the calcification number, diameter, and the diameter of tumor among head side, foot side, inner side, outer side and rear side, the difference was meaningless in terms of statistics. Based on the comparison between SNR and contrast-to-noise ratio and between dose efficiency η and quality factor M in different areas, the difference was not statistically significant. In conclusion, the imaging quality of CBBCT was good in the head, foot, inner, outer and rear sides of breast, with acceptable CT dose.
Collapse
Affiliation(s)
- Min Xu
- Department of Radiology, Affiliated Lishui Hospital of Zhejiang University, Lishui, Zhejiang 323000, P.R. China
| | - Xue Cheng
- Department of Radiology, Affiliated Lishui Hospital of Zhejiang University, Lishui, Zhejiang 323000, P.R. China
| | - Xingyao Cheng
- Department of Radiology, Affiliated Lishui Hospital of Zhejiang University, Lishui, Zhejiang 323000, P.R. China
| | - Xilin Lan
- Department of Radiology, Affiliated Lishui Hospital of Zhejiang University, Lishui, Zhejiang 323000, P.R. China
| | - Shuzheng Chen
- Department of Radiology, Affiliated Lishui Hospital of Zhejiang University, Lishui, Zhejiang 323000, P.R. China
| | - Jiansong Ji
- Department of Radiology, Affiliated Lishui Hospital of Zhejiang University, Lishui, Zhejiang 323000, P.R. China
| |
Collapse
|