1
|
Li X, Fan B, Liu L, Chen D, Cao S, Men D, Wang J, Chen J. A Microfluidic Fluorescent Flow Cytometry Capable of Quantifying Cell Sizes and Numbers of Specific Cytosolic Proteins. Sci Rep 2018; 8:14229. [PMID: 30242168 PMCID: PMC6155059 DOI: 10.1038/s41598-018-32333-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Accepted: 07/06/2018] [Indexed: 12/20/2022] Open
Abstract
This study presents a microfluidics based cytometry capable of characterizing cell sizes and counting numbers of specific cytosolic proteins where cells were first bound by antibodies labelled with fluorescence and then aspirated into a constriction microchannel in which fluorescent levels were measured. These raw fluorescent pulses were further divided into a rising domain, a stable domain and a declining domain. In addition, antibody solutions with labelled fluorescence were aspirated through the constriction microchannel, yielding curves to translate raw fluorescent levels to protein concentrations. By using key parameters of three domains as well as the calibration curves, cell diameters and the absolute number of β-actins at the single-cell level were quantified as 14.2 ± 1.7 μm and 9.62 ± 4.29 × 105 (A549, ncell = 14 242), 13.0 ± 2.0 μm and 6.46 ± 3.34 × 105 (Hep G2, ncell = 35 932), 13.8 ± 1.9 μm and 1.58 ± 0.90 × 106 (MCF 10 A, ncell = 16 650), and 12.7 ± 1.5 μm and 1.09 ± 0.49 × 106 (HeLa, ncell = 26 246). This platform could be further adopted to measure numbers of various cytosolic proteins, providing key insights in proteomics at the single-cell level.
Collapse
Affiliation(s)
- Xiufeng Li
- State Key Lab of Transducer Technology, Institute of Electronics of Chinese Academy of Sciences, Beijing City, China.,University of Chinese Academy of Sciences, Beijing City, China
| | - Beiyuan Fan
- State Key Lab of Transducer Technology, Institute of Electronics of Chinese Academy of Sciences, Beijing City, China.,University of Chinese Academy of Sciences, Beijing City, China
| | - Lixing Liu
- State Key Lab of Transducer Technology, Institute of Electronics of Chinese Academy of Sciences, Beijing City, China.,University of Chinese Academy of Sciences, Beijing City, China
| | - Deyong Chen
- State Key Lab of Transducer Technology, Institute of Electronics of Chinese Academy of Sciences, Beijing City, China.,University of Chinese Academy of Sciences, Beijing City, China
| | - Shanshan Cao
- State Key Lab of Virology, Wuhan Institute of Virology of Chinese Academy of Sciences, Wuhan City, Hubei Province, China
| | - Dong Men
- State Key Lab of Virology, Wuhan Institute of Virology of Chinese Academy of Sciences, Wuhan City, Hubei Province, China.
| | - Junbo Wang
- State Key Lab of Transducer Technology, Institute of Electronics of Chinese Academy of Sciences, Beijing City, China. .,University of Chinese Academy of Sciences, Beijing City, China.
| | - Jian Chen
- State Key Lab of Transducer Technology, Institute of Electronics of Chinese Academy of Sciences, Beijing City, China. .,University of Chinese Academy of Sciences, Beijing City, China.
| |
Collapse
|
2
|
Kubsch B, Robinson T, Steinkühler J, Dimova R. Phase Behavior of Charged Vesicles Under Symmetric and Asymmetric Solution Conditions Monitored with Fluorescence Microscopy. J Vis Exp 2017. [PMID: 29155700 PMCID: PMC5755220 DOI: 10.3791/56034] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Phase-separated giant unilamellar vesicles (GUVs) exhibiting coexisting liquid-ordered and liquid-disordered domains are a common biophysical tool to investigate the lipid raft hypothesis. Numerous studies, however, neglect the impact of physiological solution conditions. On that account, the current work presents the effect of high-salinity buffer and trans-membrane solution asymmetry on liquid-liquid phase separation in charged GUVs grown from dioleylphosphatidylglycerol, egg sphingomyelin, and cholesterol. The effects were studied under isothermal and varying temperature conditions. We describe equipment and experimental strategies applicable for monitoring the stability of coexisting liquid domains in charged vesicles under symmetric and asymmetric high-salinity solution conditions. This includes an approach to prepare charged multicomponent GUVs in high-salinity buffer at high temperatures. The protocol entails the option to perform a partial exchange of the external solution by a simple dilution step while minimizing the vesicle dilution. An alternative approach is presented utilizing a microfluidic device that allows for a complete external solution exchange. The solution effects on phase separation were also studied under varying temperatures. To this end, we present the basic design and utility of an in-house built temperature control chamber. Furthermore, we reflect on the assessment of the GUV phase state, pitfalls associated with it and how to circumvent them.
Collapse
|
3
|
Morinishi LS, Blainey P. Simple Bulk Readout of Digital Nucleic Acid Quantification Assays. J Vis Exp 2015. [PMID: 26436576 DOI: 10.3791/52925] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Digital assays are powerful methods that enable detection of rare cells and counting of individual nucleic acid molecules. However, digital assays are still not routinely applied, due to the cost and specific equipment associated with commercially available methods. Here we present a simplified method for readout of digital droplet assays using a conventional real-time PCR instrument to measure bulk fluorescence of droplet-based digital assays. We characterize the performance of the bulk readout assay using synthetic droplet mixtures and a droplet digital multiple displacement amplification (MDA) assay. Quantitative MDA particularly benefits from a digital reaction format, but our new method applies to any digital assay. For established digital assay protocols such as digital PCR, this method serves to speed up and simplify assay readout. Our bulk readout methodology brings the advantages of partitioned assays without the need for specialized readout instrumentation. The principal limitations of the bulk readout methodology are reduced dynamic range compared with droplet-counting platforms and the need for a standard sample, although the requirements for this standard are less demanding than for a conventional real-time experiment. Quantitative whole genome amplification (WGA) is used to test for contaminants in WGA reactions and is the most sensitive way to detect the presence of DNA fragments with unknown sequences, giving the method great promise in diverse application areas including pharmaceutical quality control and astrobiology.
Collapse
Affiliation(s)
| | - Paul Blainey
- Department of Biological Engineering, Massachusetts Institute of Technology;
| |
Collapse
|