1
|
Martinez LC, Tello A, Galvis V, Villamizar SJ, Nova DV. DETERMINATION OF FACTORS ASSOCIATED WITH LONG-TERM ENDOTHELIAL LOSS AND REFRACTIVE RESULT IN PATIENTS WITH ARTISAN PHAKIC LENS. CESKA A SLOVENSKA OFTALMOLOGIE : CASOPIS CESKE OFTALMOLOGICKE SPOLECNOSTI A SLOVENSKE OFTALMOLOGICKE SPOLECNOSTI 2022; 78:188-195. [PMID: 36049894 DOI: 10.31348/2022/21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
PURPOSE To determine the changes in endothelial cell density, refractive results, and risk factors associated with endothelial loss in patients with irisclaw phakic intraocular lenses for myopia/myopic astigmatism (Artisan). METHODOLOGY Data collection was obtained from an existing database with information on patients with a phakic Artisan lens implant between 1998 and 2011 at the Virgilio Galvis Ophthalmology Centre, with at least 5 years of follow-up. As a second stage, an analysis was carried out to identify the change in endothelial cell density and its potential associated factors. RESULTS A total of 80 eyes with myopic errors were included with a follow-up of 11.9 + 3.48 years. The percentage of total loss of endothelial cells was greater than 25% of the preoperative density in 43.8% of the eyes. A postoperative annual loss > 1.6% was found in 47.0% of the eyes with that information available. 41 eyes (51%) had final endothelial density < 2000 cells/mm2, and 7 (8.8%) eyes had endothelial cell density < 1000 cells/mm2. Among the variables studied, no associated factors for long-term endothelial loss were found. During the course of the study, 8 (10%) phakic intraocular lenses were explanted, including 3 with accelerated endothelial loss, and another 2 with cataract associated and a significantly low endothelial density. The last mean spherical equivalent was -0.81 (±1.01 D), and the final uncorrected distance visual acuity was 0.45 logMar (Snellen 20/56). CONCLUSION Artisan-type phakic lenses are a good alternative for the correction of high myopic defects, with predictable refractive results in the long term. However, there is an increased loss of endothelial cells in the long term in a high percentage of patients. Strict postoperative follow-up, including endothelial evaluation, is required, and further studies are warranted.
Collapse
|
2
|
Barros L, Sena N, Motta C, Criado G, Ambrósio R. Lentes intraoculares fácicas para miopia e astigmatismo: revisão prospectiva. REVISTA BRASILEIRA DE OFTALMOLOGIA 2021. [DOI: 10.37039/1982.8551.20210012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
3
|
Joshi RS. Clear lens extraction for patients who are unfit for laser-assisted in situ keratomileusis and implantable contact lenses in central Indian population. Indian J Ophthalmol 2020; 68:3002-3005. [PMID: 33229686 PMCID: PMC7856966 DOI: 10.4103/ijo.ijo_1307_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Purpose: The purpose of this study is to establish the safety of clear lens extraction (CLE) for the correction of high myopia in patients unfit for implantable contact lenses (ICLs) and laser in situ keratomileusis in the central Indian population. Methods: In this retrospective observational study performed at a tertiary care centre, medical records of the patients who had undergone CLE with implantation of intraocular lens (IOL) to treat high myopia were retrieved. Details of the demographic profile, surgical procedure, complications, power, and type of IOLs implanted were recorded. Results: The average postoperative follow-up period was 64.1 ± 4.2 months. The average postoperative spherical power was −1.4 ± 0.6 D, which was much lower than the preoperative spectacle power - 15 ± 4.4 D. There was improvement in the postoperative visual acuity (0.4 ± 0.2 logMAR) from the preoperative distant uncorrected visual acuity (0.8 ± 0.2 logMAR). No significant change in intraocular pressure (IOP) was observed. The postoperative average anterior chamber depth (ACD) (2.66 ± 0.1 mm) was significantly deeper than the preoperative ACD (2.61 ± 0.1 mm) P = 0.00. Barrage laser was required for lattice degeneration in one patient before CLE and in two patients during follow-up. Two patients (8.7%) required Nd:YAG capsulotomy for posterior capsular opacification. None of the patients had corneal decompensation, retinal detachment, or endophthalmitis. Conclusion: CLE with implantation of IOL is the safe procedure for correcting high myopia in patients who are unfit for ICL. None of the patient had eye loss in the follow-up period of 5 years. The low incidence of complications can be attributable to the closed chamber lens removal and implantation of IOL and prophylactic retinal treatment.
Collapse
Affiliation(s)
- Rajesh Subhash Joshi
- Department of Ophthalmology, Government Medical College, Nagpur, Maharashtra, India
| |
Collapse
|
4
|
Refractive Errors & Refractive Surgery Preferred Practice Pattern®. Ophthalmology 2018; 125:P1-P104. [DOI: 10.1016/j.ophtha.2017.10.003] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 10/02/2017] [Indexed: 11/19/2022] Open
|
5
|
Iijima A, Shimizu K, Yamagishi M, Kobashi H, Igarashi A, Kamiya K. Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation. Acta Ophthalmol 2016; 94:e716-e720. [PMID: 27288153 DOI: 10.1111/aos.13092] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Accepted: 03/17/2016] [Indexed: 01/22/2023]
Abstract
PURPOSE To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation. METHODS We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant™ , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms. RESULTS The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017). CONCLUSIONS According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one.
Collapse
Affiliation(s)
- Ayaka Iijima
- Department of Ophthalmology; University of Kitasato School of Medicine; Kanagawa Japan
| | - Kimiya Shimizu
- Department of Ophthalmology; University of Kitasato School of Medicine; Kanagawa Japan
| | - Mayumi Yamagishi
- Department of Ophthalmology; University of Kitasato School of Medicine; Kanagawa Japan
| | - Hidenaga Kobashi
- Department of Ophthalmology; University of Kitasato School of Medicine; Kanagawa Japan
| | - Akihito Igarashi
- Department of Ophthalmology; University of Kitasato School of Medicine; Kanagawa Japan
| | - Kazutaka Kamiya
- Department of Ophthalmology; University of Kitasato School of Medicine; Kanagawa Japan
| |
Collapse
|
6
|
Kwon HJ, Nam SM, Stulting RD, Lim CY, Seo KY. Comparison of surgically induced astigmatism following iris-claw PIOL insertion with scleral, limbal, or corneal incisions. J Refract Surg 2014; 30:330-5. [PMID: 24893358 DOI: 10.3928/1081597x-20140416-02] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2013] [Accepted: 12/05/2013] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare surgically induced astigmatism (SIA) based on incision site and evaluate the clinical results and astigmatic stability of iris-claw phakic intraocular lens (Artisan lens; Ophtec BV, Groningen, Netherlands) implantation. METHODS Eighty-five eyes of 53 patients with myopia who underwent Artisan lens implantation with a 6.2-mm incision and follow-up of 6 months were retrospectively observed. SIA was assessed using keratometric astigmatism at 6 months postoperatively for the incision sites of the sclera, limbus, and cornea, and the efficacy, safety, predictability, and astigmatic stability were also calculated. RESULTS SIA obtained using Naeser's polar method (KP[90]SIA) was -0.48 ± 0.35 for scleral incisions, -0.99 ± 0.35 for limbal incisions, and -1.14 ± 0.54 for corneal incisions. Corresponding net astigmatism values, as calculated with KP(90)SIA and KP(135)SIA, were 0.70 ± 0.48 (177°), 1.04 ± 0.37 (175°), and 1.21 ± 0.57 (1°), respectively, with SIA increasing the nearer the incision was to the cornea center. Six months after surgery, the efficacy index was 1.03 and the safety index was 1.08. Ninety-eight percent of patients were within 1.50 diopters of attempted refraction. CONCLUSIONS The values of SIA after Artisan lens insertion showed significant differences among three incision locations, despite the absence of significant differences in preoperative steep corneal axis astigmatism values at the incision locations. It would be applicable for refractive surgery in the aspect of minimizing astigmatism after surgery.
Collapse
|
7
|
Kwitko S, Stolz AP. Iris-claw (Artisan®/Artiflex®) phakic intraocular lenses for high myopia and high hyperopia. EXPERT REVIEW OF OPHTHALMOLOGY 2014. [DOI: 10.1586/eop.11.57] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
8
|
van den Berg TJTP, Franssen L, Kruijt B, Coppens JE. History of ocular straylight measurement: A review. Z Med Phys 2012. [PMID: 23182462 DOI: 10.1016/j.zemedi.2012.10.009] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The earliest studies on 'disability glare' date from the early 20(th) century. The condition was defined as the negative effect on visual function of a bright light located at some distance in the visual field. It was found that for larger angles (>1 degree) the functional effect corresponded precisely to the effect of a light with a luminosity equal to that of the light that is perceived spreading around such a bright source. This perceived spreading of light was called straylight and by international standard disability glare was defined as identical to straylight. The phenomenon was recognized in the ophthalmological community as an important aspect of the quality of vision and attempts were made to design instruments to measure it. This must not be confused with instruments that assess light spreading over small distances (<1 degree), as originating from (higher order) aberrations and defocus. In recent years a new instrument has gained acceptance (C-Quant) for objective and controllable assessment of straylight in the clinical setting. This overview provides a sketch of the historical development of straylight measurement, as well as the results of studies on the origins of straylight (or disability glare) in the normal eye, and on findings on cataract (surgery) and corneal conditions.
Collapse
Affiliation(s)
- Thomas J T P van den Berg
- Netherlands Institute for Neuroscience, Institute of the Royal Netherlands Academy of Arts and Sciences, Meibergdreef 47, 1105 BA Amsterdam, The Netherlands.
| | | | | | | |
Collapse
|
9
|
Park DH, Lane SS. Phakic Myopic Intraocular Lenses. Cornea 2011. [DOI: 10.1016/b978-0-323-06387-6.00178-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
10
|
Fournié P, Malecaze F. [Iris-fixated intraocular lenses: reinforced monitoring]. J Fr Ophtalmol 2009; 32:687-94. [PMID: 19520458 DOI: 10.1016/j.jfo.2009.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2008] [Accepted: 04/23/2009] [Indexed: 11/29/2022]
Abstract
In 1986, the concept of the claw lens was applied to correct myopia in phakic patients. Since then, progress has made iris-fixated phakic intraocular lenses (IOL) relatively safe, predictable, and effective for the correction of myopia, hyperopia, and astigmatism. All these models have undergone a series of design improvements to prevent complications. Despite having excellent refractive results, the principal risk is a potential progressive endothelial cell loss. Many authors have presented encouraging results. Phakic iris-fixated IOL surgery is a potentially reversible procedure, but the surgeon cannot rule out the possibility of complications. Therefore, long-term follow-up is mandatory.
Collapse
Affiliation(s)
- P Fournié
- Service d'Ophtalmologie, CHU Toulouse, Hôpital Purpan, France.
| | | |
Collapse
|
11
|
Chen LJ, Chang YJ, Kuo JC, Rajagopal R, Azar DT. Metaanalysis of cataract development after phakic intraocular lens surgery. J Cataract Refract Surg 2008; 34:1181-200. [PMID: 18571089 DOI: 10.1016/j.jcrs.2008.03.029] [Citation(s) in RCA: 105] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2007] [Accepted: 03/24/2008] [Indexed: 11/24/2022]
|
12
|
Tychsen L, Hoekel J, Ghasia F, Yoon-Huang G. Phakic intraocular lens correction of high ametropia in children with neurobehavioral disorders. J AAPOS 2008; 12:282-9. [PMID: 18589386 DOI: 10.1016/j.jaapos.2007.12.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2007] [Revised: 12/03/2007] [Accepted: 12/11/2007] [Indexed: 11/24/2022]
Abstract
PURPOSE A subset of children with high ametropia and neurobehavioral disorders have chronic difficulties with spectacle or contact lens wear. We report the results of refractive surgery in a series of these children treated using bilateral or unilateral phakic intraocular lenses (IOLs) for ametropia >10 D. METHODS Clinical course and outcome data were collated prospectively in a group of 12 children (mean age, 10.1 years; range, 4-17 years) with neurobehavioral disorders exacerbated by poor compliance with spectacles. Myopia in 18 eyes ranged from -10.0 to -22.75 D (mean, -15.2 D) and in 2 hyperopic eyes from +10.25 to +10.75 (mean, +10.5 D). Goal refraction was approximately 0 to +1 D. Correction was achieved by implantation of an iris-enclaved phakic IOL under general anesthesia. Mean follow-up was 9.1 months (range, 3-15 months). RESULTS Myopia correction averaged 14.5 D and hyperopia correction 9.4 D. Eighty-six percent of eyes (17/20 eyes) were corrected to within +/- 1 D of emmetropia and the remaining 14% (3 eyes) to within +/- 2 D. Uncorrected visual acuity improved substantially in all 20 eyes (60-fold; from a mean of 20/3400 to a mean of 20/57). Ocular comorbidities in each child accounted for residual postoperative, subnormal visual acuity (eg, amblyopia, nystagmus, albinism, regressed retinopathy of prematurity). Visual functions (measured using a 23-item validated survey) improved. One eye required IOL exchange; no other clinically significant complications have been encountered. CONCLUSIONS Phakic IOL implantation improves visual function substantially in neurobehaviorally impaired children who have high ametropia and difficulties wearing glasses.
Collapse
Affiliation(s)
- Lawrence Tychsen
- Department of Ophthalmology and Visual Sciences, St. Louis Children's Hospital at Washington University School of Medicine, St. Louis, MO 63110, USA.
| | | | | | | |
Collapse
|
13
|
Choi WS, Choi BJ, Her J. Two-year Endothalial Changes after Iris Fixed Phakic Intraocular Lens Implantation in Korean. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2008. [DOI: 10.3341/jkos.2008.49.2.230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Woo Seok Choi
- Department of Ophthalmology, Pusan Paik Hospital, College of Medicine, Inje University, Pusan, Korea
| | | | - Jun Her
- Department of Ophthalmology, Pusan Paik Hospital, College of Medicine, Inje University, Pusan, Korea
| |
Collapse
|
14
|
Choi WS, Lee HY, Seo SG, Her J. Clinical Outcomes of Implantable Contact Lens and Iris-Fixed Intraocular Lens for Correction of Myopia. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2008. [DOI: 10.3341/jkos.2008.49.9.1406] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Woo Seok Choi
- Department of Ophthalmology, Pusan Paik Hospital, Inje University College of Medicine, Pusan, Korea
| | - Ho Young Lee
- Department of Ophthalmology, Pusan Paik Hospital, Inje University College of Medicine, Pusan, Korea
| | - Sung Guan Seo
- Department of Ophthalmology, Pusan Paik Hospital, Inje University College of Medicine, Pusan, Korea
| | - Jun Her
- Department of Ophthalmology, Pusan Paik Hospital, Inje University College of Medicine, Pusan, Korea
| |
Collapse
|
15
|
Benedetti S, Casamenti V, Benedetti M. Long-term endothelial changes in phakic eyes after Artisan intraocular lens implantation to correct myopia: five-year study. J Cataract Refract Surg 2007; 33:784-90. [PMID: 17466848 DOI: 10.1016/j.jcrs.2007.01.037] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2006] [Accepted: 01/26/2007] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate long-term endothelial cell changes in eyes that had implantation of an iris-fixated phakic Artisan intraocular lens (IOL) for moderate to high myopia. SETTING Casa di Cura Villa Igea, Ancona, Italy. METHODS Forty-nine eyes of 30 patients having implantation of Artisan IOL for moderate to high myopia were prospectively examined. Preoperative specular microscopy and serial postoperative specular microscopy (Noncon Robo SP 8000, Konan Medical) were performed to evaluate endothelial cell changes over 5 years. Endothelial cell images were collected in the central region of the cornea before surgery and 4, 12, 24, 36, 48, and 60 months after surgery. The endothelial cell density (ECD), coefficient of variation, and percentage of hexagonal cells were determined. RESULTS Preoperatively, the mean ECD was 2616 cells/mm(2) +/- 347 (SD), the mean coefficient of variation was 39.6% +/- 4.7%, and the mean percentage of hexagonal cells was 49.2% +/- 6.7%. The mean endothelial cell loss from preoperatively was 2.3% at 4 months, 3.5% at 12 months, 4.7% at 24 months, 6.7% at 3 years, 8.3% at 4 years, and 9.0% at 5 years. Five years after surgery, the mean coefficient of variation was 35.9% +/- 6.9% (P = .1946) and the percentage of hexagonal cells was significantly higher (mean 54.7% +/- 10.3%) (P = .087). CONCLUSIONS Continuous endothelial cell loss was observed after surgery during a 5-year follow-up, especially during the first 2 years. A decrease in the coefficient of variation and an increase in the percentage of hexagonal cells were observed over time, reflecting the increasing stability and remodeling of the corneal endothelial cells 5 years postoperatively.
Collapse
|
16
|
Abstract
An analytical review of the data available in the field of phakic intraocular lens implantation was conducted. Particular attention was paid to the more critical issues of intraocular lens sizing and safety guidelines. A comprehensive, competitive analysis of different implantation sites, intraocular lens model designs, and safety guidelines has been included. Specialized biometry techniques, such as very high frequency ultrasound and Scheimpflug imaging, have been reviewed, and a critical review of commercial claims regarding intraocular lens technologies has been included. Clinical studies of phakic intraocular lenses demonstrate increasing promise for the correction of refractive errors not amenable to mainstream excimer laser refractive surgery. The main issues currently revolve around adequate lens design (VHF ultrasound study suggests that custom-design and sizing may be the most effective and safest approach for every phakic IOL model), because these devices will be required to remain physiologically inert and anatomically compatible with internal ocular structures and relations for several decades. The possibility of safe removing or exchanging the IOL should remain a feasible option over time. It is of utmost importance that we continue to critically evaluate current encouraging short-term outcomes, which are being extrapolated to the longer term by ongoing high resolution imaging and monitoring of the anatomical and functional relations of implanted phakic IOLs.
Collapse
Affiliation(s)
- Carlo F Lovisolo
- Department of Ophthalmology and Visual Sciences, San Raffaele Hospital and QuattroElle Eye Center, Milan, Italy, and Department of Ophthalmology, St. Thomas Hospital-Kings College, London, UK.
| | | |
Collapse
|
17
|
Lifshitz T, Levy J, Aizenman I, Klemperer I, Levinger S. Artisan Phakic Intraocular Lens for Correcting High Myopia. Int Ophthalmol 2005; 25:233-8. [PMID: 16200450 DOI: 10.1007/s10792-005-5016-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2004] [Accepted: 03/17/2005] [Indexed: 10/25/2022]
Abstract
OBJECTIVES To evaluate the safety indexes and efficacy of Artisan phakic intraocular lens (IOL) for the correction of high myopia. METHODS Retrospective interventional case series reports. Thirty-one eyes (22 patients) with myopia from -5.25 to -19.00 diopters underwent implantation of an Artisan phakic IOL. Follow-up examinations were performed at 1 day, 1 week, 1 month, and 3 months. The following parameters were recorded: manifest refraction, slit-lamp examination, applanation tonometry, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), complications or adverse reactions. The primary variable was the refractive outcome at 3 months. Secondary variables were change in BSCVA, and efficacy and safety indexes. RESULTS At 3 months, mean spherical equivalent was -0.50 +/- 0.36 diopters (range, -1.25 - plano). In 29 eyes (93.5%) UCVA was 6/12 or better; the other three eyes had UCVA of 6/15. The difference between preoperative and 1 week postoperative BSCVA was not statistically significant (p = 0.25). Comparison of BSCVA at 1 week and at 1 month was statistically significant (p = 0.05); this difference was even more significant at 3 months (p = 0.01). The BSCVA remained the same or improved for all the eyes. BSCVA for 20 eyes (64.5%) had improved one or more lines in visual acuity. Mean endothelial cell loss at 3 months was 3.96%. CONCLUSION The Artisan lens is a safe, predictable, and efficacious method to correct high myopia. Postoperative gain in BSCVA was achieved for the majority of eyes. Future study to assess safety indexes and risk of complications is required with long-term follow-up.
Collapse
Affiliation(s)
- Tova Lifshitz
- Department of Ophthalmology (Sheva Enaim), Soroka University Medical Center, Ben-Gurion University of the Negev, PO Box 151, Beer-Sheva, 84101, Israel
| | | | | | | | | |
Collapse
|
18
|
Benedetti S, Casamenti V, Marcaccio L, Brogioni C, Assetto V. Correction of Myopia of 7 to 24 Diopters With the Artisan Phakic Intraocular Lens: Two-year Follow-up. J Refract Surg 2005; 21:116-26. [PMID: 15796215 DOI: 10.3928/1081-597x-20050301-05] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of the iris claw phakic intraocular lens (Artisan; Ophtec BV, Groningen, The Netherlands) in patients with high myopia. METHODS Between May 1999 and July 2001, 93 Artisan phakic intraocular lenses (IOLs) were implanted in 60 patients affected by high myopia. All patients underwent 24-month follow-up. The power of the lenses ranged from -7.5 to -22.0 diopters (D). Patients were divided into two groups: group 1 (68 eyes), myopia -6.75 to -15.50 D (SE), and group 2 (25 eyes), myopia -16.0 to -23.0 D (SE). Pre- and postoperative patient evaluation included manifest and cycloplegic refractions, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), endothelial cell count, intraocular pressure, complication rate, safety, and efficacy. RESULTS At 4 months, 83.8% (57/68) (group 1, myopia -6.75 to -15.50 D) and 68% (17/25) (group 2, myopia -16.0 to -23.0 D) of eyes achieved UCVA of > or =20/40. The BSCVA remained the same or improved in 100% of eyes. After 4 months, 69.1% (47/68) of eyes in group 1 and 52% (13/25) of eyes in group 2 were within +/-1.00 D of the desired refraction; the mean refraction was stable between 4 and 24 months. Of the intraoperative complications, 69.2% were observed in the first 25 lenses implanted; postoperative complications included iris atrophy in 11.8% (11/93), lens decentration in 5.4% (5/93), and night glare in 6.4% (6/93) of eyes. No IOLs were removed. Mean endothelial cell loss was 2.8% at 4 months, 3.9% at 12 months, and 5.4% at 24 months. CONCLUSIONS Our results regarding implantation of the Artisan phakic IOL confirm that these lenses are safe and effective for the correction of high myopia, with a stable refractive outcome but with a higher than normal rate of endothelial cell loss during 2-year follow-up.
Collapse
|
19
|
Pineda-Fernández A, Jaramillo J, Vargas J, Jaramillo M, Jaramillo J, Galíndez A. Phakic posterior chamber intraocular lens for high myopia. J Cataract Refract Surg 2004; 30:2277-83. [PMID: 15519075 DOI: 10.1016/j.jcrs.2004.03.035] [Citation(s) in RCA: 108] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/09/2004] [Indexed: 11/30/2022]
Abstract
PURPOSE To evaluate the efficacy, predictability, stability, and safety of the surgical correction of high myopia using a phakic posterior chamber intraocular lens (PPC IOL). SETTING Centro Oftalmológico de Valencia-CEOVAL, Valencia, Venezuela. METHODS A retrospective study was performed to analyze 18 eyes of 12 patients who had implantation of a modified PPC IOL, the implantable contact lens (ICL), for the treatment of high myopia. The target postoperative spherical equivalent (SE) refraction was emmetropia. RESULTS The mean follow-up was 26.6 months +/- 11.3 (SD) (range 12 to 36 months). The mean preoperative SE was -15.27 +/- 3.47 diopters (D) (range -10.0 to -21.25 D) and the mean postoperative SE, -0.62 +/- 0.81 D (range -2.75 to +0.75 D). Eleven eyes (61.1%) had an SE within +/-1.00 D of emmetropia. The best spectacle-corrected visual acuity was maintained or improved in all except 1 eye, which lost more than 2 lines of Snellen visual acuity. Two eyes (11.1%) developed pupillary block the first day after surgery. Four eyes (22.2%) had moderate pigmentary dispersion. Two eyes (11.1%) had lens opacification, 1 with mild peripheral anterior capsule opacification and the other eye with central anterior subcapsular opacification. One eye (5.5%) had a significant decrease in anterior chamber depth after surgery. CONCLUSIONS Implantation of an ICL was effective for the correction of high myopia. Predictability must be improved and the long-term safety of the ICL determined. The main concerns over potential cataract formation, pigmentary dispersion, and angle-closure glaucoma remain.
Collapse
|
20
|
Bartels MC, van Rij G, Luyten GPM. Implantation of a toric phakic intraocular lens to correct high corneal astigmatism in a patient with bilateral marginal corneal degeneration. J Cataract Refract Surg 2004; 30:499-502. [PMID: 15030849 DOI: 10.1016/j.jcrs.2003.06.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/25/2003] [Indexed: 11/20/2022]
Abstract
We present a patient with marginal corneal degeneration and corneal astigmatism of more than 10.0 diopters (D). A toric phakic intraocular lens (IOL) of 7.0 D cylindrical power was implanted in both eyes to correct the high astigmatism. An uncorrected visual acuity of 20/40 was achieved in both eyes, and the best corrected visual acuity improved by 4 Snellen lines to 20/20 in both eyes. Refraction and visual acuity remained stable at 1.5 years postoperatively. Implantation of a toric phakic IOL can be an option to correct high corneal astigmatism even when the full corneal astigmatism cannot be treated.
Collapse
Affiliation(s)
- Marjolijn C Bartels
- Department of Ophthalmology, Erasmus Medical Center, Rotterdam, The Netherlands.
| | | | | |
Collapse
|
21
|
Nio YK, Jansonius NM, Wijdh RHJ, Beekhuis WH, Worst JGF, Norrby S, Kooijman AC. Effect of methods of myopia correction on visual acuity, contrast sensitivity, and depth of focus. J Cataract Refract Surg 2003; 29:2082-95. [PMID: 14670416 DOI: 10.1016/j.jcrs.2003.07.008] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To psychophysically measure spherical and irregular aberrations in patients with various types of myopia correction. SETTING Laboratory of Experimental Ophthalmology, University of Groningen, Groningen, The Netherlands. METHODS Three groups of patients with low myopia correction (spectacles, soft contact lens, and Intacs) and 4 groups with high myopia correction (spectacles, rigid contact lens, Artisan claw lens, and laser in situ keratomileusis [LASIK]) had through-focus contrast sensitivity measurements to establish the myopic shift and depth of focus. From these 2 parameters, spherical and irregular aberrations were determined using theoretical eye models and geometric optics. Visual acuity, stray light, and predictability were also studied. RESULTS There were no differences in best corrected visual acuity (BCVA) or best corrected contrast sensitivity between the low myopia groups. The Intacs group had a significantly larger depth of focus (P<.05). The results in the soft contact lens group were comparable to those in a human eye model with an average amount of spherical and irregular aberrations. The LASIK group had worse uncorrected visual acuity (UCVA) and best corrected contrast sensitivity than the spectacles, rigid contact lens, and Artisan claw lens groups (P<.05) due to the amount of spherical and irregular aberrations present after LASIK. The low and high myopia spectacles groups had average amounts of spherical and irregular aberrations. CONCLUSIONS Neither surgical techniques nor contact lenses resulted in BCVA or best corrected contrast sensitivity that surpassed the values measured in the best corrected spectacles groups. The Artisan claw lens performed better than LASIK in UCVA, predictability, and best corrected contrast sensitivity.
Collapse
Affiliation(s)
- Ying Khay Nio
- Laboratory of Experimental Ophthalmology, University of Groningen, Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
22
|
Aguilar-Valenzuela L, Lleó-Pérez A, Alonso-Muñoz L, Casanova-Izquierdo J, Pérez-Moltó FJ, Rahhal MS. Intraocular Pressure in Myopic Patients After Worst-Fechner Anterior Chamber Phakic Intraocular Lens Implantation. J Refract Surg 2003; 19:131-6. [PMID: 12701717 DOI: 10.3928/1081-597x-20030301-07] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess intraocular pressure measured with a Goldmann tonometer over a period of 1 year after implantation of a Worst-Fechner anterior chamber phakic intraocular lens to correct myopia of -7.00 D or more. METHODS We performed a prospective, non-masked study of 100 patients (100 myopic eyes) who had a Worst-Fechner phakic intraocular lens implanted to correct myopia of -7.00 D or greater. Central corneal Goldmann tonometry was performed before surgery and 1, 3, 6, and 12 months after surgery. The influence of different variables was assessed. RESULTS IOP showed a significant increase of a mean 2.1 mmHg at 3 months after surgery (P=.001). There was not a statistically significant difference between IOP before surgery and 6 months after PIOL implantation (P=.244) or 1 year after surgery (P=.845). In one eye, the lens was explanted 11 months after surgery because of the presence of ocular hypertension. No variables studied showed a statistically significant difference from before to after surgery. CONCLUSIONS Worst-Fechner anterior chamber phakic intraocular lens implantation led to a slight transitory increase of intraocular pressure during the first 3 months after surgery, but returned to preoperative levels by 6 months after implantation.
Collapse
|
23
|
Affiliation(s)
- José L Güell
- Corneal and Refractive Surgery Unit, Instituto de Microcirugia Ocular, Barcelona, Spain
| | | |
Collapse
|
24
|
Nuzzi G, Cantù C. Vitreous hemorrhage following phakic anterior chamber intraocular lens implantation in severe myopia. Eur J Ophthalmol 2002; 12:69-72. [PMID: 11936449 DOI: 10.1177/112067210201200114] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To describe two cases of vitreous hemorrhage following phakic anterior chamber lens (AC-IOL) implantation in high myopia. CASE REPORT In case 1, hemorrhage developed one month after surgery, without retinal involvement, and visual acuity (VA) resulted 20/200 after pars-plana vitrectomy (PPV). In Case 2, vitreous hemorrhage was complicated by retinal detachment (RD). PPV and silicone oil injection were performed, with AC-IOL removal and cristalline lens extraction. After 2 years the retina was attached and VA was 20/80. DISCUSSION Only few cases of RD, posterior uveitis and endophthalmitis are reported following phakic AC-IOL implant. Vitreous hemorrhage could represent an additional posterior segment complication. Intraoperative manoeuvres, hypotony-induced posterior vitreous detachment and/or peripheral retina traction could play a role in engendering this complication in highly myopic eyes.
Collapse
Affiliation(s)
- G Nuzzi
- Institute of Ophthalmology, University of Parma, Italy.
| | | |
Collapse
|
25
|
Abstract
PURPOSE To evaluate the efficacy, safety, and biocompatibility of a collagen polymer implantable contact lens (ICL) (Staar Collamer) as a posterior chamber phakic intraocular lens (IOL) to correct high myopia. SETTING Departments of Ophthalmology, Helsinki University Central Hospital, Helsinki, and Tampere University Hospital, Tampere, Finland. METHODS A Staar Collamer posterior chamber phakic IOL was implanted in 38 eyes of 22 patients with a mean age of 39 years (range 24 to 54 years). The mean preoperative myopia was -15.10 diopters (D) (range -7.75 to -29.00 D). Surgical implantation was performed through a 3.0 mm clear corneal sutureless incision using paraocular anesthesia. The patients were followed clinically up to 3 years. The mean follow-up was 13.6 months (range 6 to 24 months) for refractive data and 22.3 months (range 6 to 35 months) for complications. The possible inflammatory response to the ICL was measured using a laser flare meter in 12 eyes. RESULTS Postoperatively, all eyes had a significant increase in uncorrected visual acuity, allowing all but 3 patients (5 eyes) to manage most activities without spectacles. The mean spherical equivalent refraction at the last examination was -2.00 D +/- 2.48 (SD) (range +0.13 to -13.00 D), within +/-1.00 D of the targeted refraction in 31 eyes (81.6%) and within +/-0.50 D in 27 eyes (71.1%). In eyes in which the preoperative myopia was less than -18.00 D (n = 28), the achieved refraction was within +/-1.00 D of the intended refraction in 27 eyes (96.4%) and within +/-0.50 D in 24 eyes (85.7%). The refraction remained stable with a statistically insignificant change (P >.05) at each interval during the follow-up. The best corrected visual acuity (BCVA) improved by 1 or more lines in 23 of 32 eyes (71.9%) at 1 year. Two eyes (6.3%) lost 1 line of BCVA. Laser flare photometry showed normal aqueous flare values (11.71 +/- 6.61 photon counts/ms) in the 12 eyes measured at least 6 months after ICL implantation. Pupillary block glaucoma requiring surgical intervention occurred in 3 patients (7.9%). One patient (2.6%) developed cataract 1.5 years after ICL implantation; both ICLs were removed, and the refractive errors were corrected by lensectomy and implantation of low-power posterior chamber IOLs. One patient (2.6%) showed progression of dry macular degeneration at 17 months. CONCLUSION At 1 year, ICL implantation had good visual and refractive results with excellent biocompatibility. Long-term follow-up is required to confirm that significant complications do not occur in most patients over time.
Collapse
Affiliation(s)
- Risto J Uusitalo
- Helsinki University Eye Hospital, PO Box 220, 00029 HUS, Helsinki, Finland.
| | | | | | | |
Collapse
|
26
|
Abstract
PURPOSE To evaluate the efficacy, safety, predictability, and stability of implanting a polymethylmethacrylate (PMMA) phakic intraocular lens (PIOL) (the Artisan myopia lens) to correct high myopia. METHODS An Artisan myopia lens was implanted in 78 consecutive eyes of 49 patients with preoperative myopia that ranged from -6.25 to -28.00 D. Mean patient age was 42.4 years. Mean follow-up was 10.7 months and all patients were followed for at least 6 months; 45 eyes had follow-up of 12 months, and 10 eyes had 24 months. The desired outcome was emmetropia in all eyes except for those eyes with preoperative myopia greater then -23.00 D. RESULTS Fifty-three eyes (67.9%) had a postoperative refraction at the last follow-up examination within +/-1.00 D of emmetropia, and 39 eyes (50.0%) had a postoperative refraction +/- within 0.50 D of emmetropia. The postoperative refraction remained stable during the entire follow-up period. Mean spectacle-corrected visual acuity improved from 20/32 preoperatively to 20/25 postoperatively. Mean postoperative uncorrected visual acuity was 20/32. There was no significant change in endothelial cell density from baseline. We did not encounter major complications. CONCLUSION Implantation of the Artisan myopia lens to correct high myopia resulted in a stable and fairly predictable refractive outcome. A significant endothelial cell change was not detected.
Collapse
Affiliation(s)
- M Landesz
- University Hospital Rotterdam, Department of Ophthalmology, The Netherlands
| | | | | |
Collapse
|
27
|
Abstract
Even though cataract surgery has been practiced for over 2000 years, modern cataract surgery started just some 50 years ago. with the first IOL implantation by Sir Harold Ridley. The development of intraocular lenses was accompanied by great successes and disasters. With the fast development of cataract surgical techniques over the past 15 years (ECCE, Phacoemulsification, Capsulorhexis) a successful marriage between IOL-developments and surgery was established. Indication profiles for cataract surgery and IOL implantation extended to more and more patient groups. At this time classical cataract surgery is further developing into refractive intraocular lens surgery to correct higher ametropia in clear lens or phakic eyes. This development was only possible because of the improvements of surgical techniques and implants in classical cataract surgery.
Collapse
Affiliation(s)
- G U Auffarth
- Universitäts-Augenklinik, Ruprecht Karls Universität Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg.
| | | |
Collapse
|
28
|
de Souza RF, Forseto A, Nosé R, Belfort R, Nosé W. Anterior chamber intraocular lens for high myopia: five year results. J Cataract Refract Surg 2001; 27:1248-53. [PMID: 11524198 DOI: 10.1016/s0886-3350(01)00969-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE To evaluate the effectiveness of the surgical correction of high myopia 5 years after anterior chamber intraocular lens (IOL) implantation and to analyze the lens position and related complications. SETTING Federal University of São Paulo-Escola Paulista de Medicina, São Paulo, Brazil. METHODS This prospective study comprised 26 eyes that were implanted with an anterior chamber IOL (model ZB5M) and had a minimum follow-up of 5 years. Before and after surgery, manifest and cycloplegic refractions were done; slitlamp examination was performed; anterior chamber depth was measured; and keratometry, ophthalmoscopy, and central corneal endothelial cell count were performed. At the last follow-up, computerized biomicroscopy of the anterior segment was also done. RESULTS The spherical equivalent decreased from -16.5 diopters (D) +/- 4.1 (SD) preoperatively to -0.9 +/- 0.9 D postoperatively. At the last examination, 57.7% of eyes had a spherical equivalent refraction within +/-1.0 D of emmetropia. Of eyes with a preoperative best spectacle-corrected visual acuity of 20/40 or better, 73.3% had an uncorrected visual acuity of 20/40 or better postoperatively. The mean tilt caused by the IOL was 4.4 +/- 2.7 degrees (range 0.5 to 12.2 degrees) and the mean IOL decentration, 0.3 +/- 0.2 mm (range 0.02 to 0.8 mm). The mean decrease in the endothelial cell count was 1.5%, with a mean cell density of 2808 +/- 305 cells/mm2 preoperatively and 2765 +/- 242 cells/mm2 postoperatively. Pupillary ovalization was observed in 12 eyes (46.1%). CONCLUSIONS The anterior chamber IOL safely and effectively corrected high myopia.
Collapse
Affiliation(s)
- R F de Souza
- Refractive Surgery Unit, Department of Ophthalmology, Federal University of São Paulo (UNIFESP-EPM), São Paulo, Brazil
| | | | | | | | | |
Collapse
|
29
|
Güell JL, Vázquez M, Gris O. Adjustable refractive surgery: 6-mm Artisan lens plus laser in situ keratomileusis for the correction of high myopia. Ophthalmology 2001; 108:945-52. [PMID: 11320026 DOI: 10.1016/s0161-6420(01)00548-6] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To evaluate efficacy, predictability, stability and safety of adjustable refractive surgery (ARS) by combining a phakic intraocular lens (IOL) (Artisan lens 6-mm optical zone [OZ]) and laser in situ keratomileusis (LASIK) (6.5 mm OZ) for the correction of myopia greater than -15.00 diopters (D). DESIGN Noncomparative interventional case series. PARTICIPANTS Twenty-six eyes of 18 patients with a preoperative spherical equivalent between -16.00 and -23.00 D. METHODS First surgery: An 8.5/9.5-mm flap was created and a 6-mm optic iris claw phakic IOL of -15.00 D was inserted in the anterior chamber through a posterior corneal incision. The second surgery was performed once refraction and topography were stable, between 3 and 5 months later. Second surgery: LASIK enhancement (6.5-9.2 OZ); the flap was relifted, and the residual refractive error was corrected. MAIN OUTCOME MEASURES The main parameters in this study were uncorrected visual acuity, best-corrected visual acuity (BCVA), refraction, contrast sensitivity, endothelial cell count (ECC), and subjective response. RESULTS Twenty-eight months after both surgeries, 80.70% of the eyes were within 0.50 D of emmetropia and 100% within 1.0 D. Twenty-six percent of the eyes gained 3 or more lines from their preoperative BCVA, and 42% gained 2 or more lines. There was no visual loss in any eye from 6 weeks to 24 months after LASIK enhancement (second surgery) and refraction, and visual acuities remained stable. Two subjects (11%) had some subjective disturbances at night. There was a 0.61% mean loss of ECC during the first 12 months and a 0.60% loss during the next 16 months. No serious complications were observed. CONCLUSIONS ARS with the combination of a 6-mm optic, 15 D Artisan lens, and LASIK appears to be a safe and highly predictable method for the correction of myopia greater than -15.00 D. It is the best approach with the technology currently available.
Collapse
Affiliation(s)
- J L Güell
- Instituto de Microcirugía Ocular (IMO), Munner 10, 08022 Barcelona, Spain
| | | | | |
Collapse
|
30
|
Werner L, Apple DJ, Izak AM, Pandey SK, Trivedi RH, Macky TA. Phakic anterior chamber intraocular lenses. Int Ophthalmol Clin 2001; 41:133-52. [PMID: 11481544 DOI: 10.1097/00004397-200107000-00011] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2023]
Affiliation(s)
- L Werner
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425, USA
| | | | | | | | | | | |
Collapse
|
31
|
Refractive Surgery in the Developing World. Surv Ophthalmol 2000. [DOI: 10.1016/s0039-6257(00)00178-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
32
|
|
33
|
Abstract
PURPOSE To review the major advances in the field of refractive surgery occurring over the past 25 years. METHODS Literature review. RESULTS The major developments in refractive surgery over the past 25 years are reviewed. CONCLUSIONS The past 25 years have witnessed great changes in refractive surgery. As a result of advancements in technology, instrumentation, and technique, we have seen improvements in the treatment of all types of ametropias. In this article, we review some of the successes and failures of the past quarter-century.
Collapse
Affiliation(s)
- R D Stulting
- Cornea Service, Emory University School of Medicine, Department of Ophthalmology, Atlanta, Georgia, USA
| | | | | |
Collapse
|
34
|
Budo C, Hessloehl JC, Izak M, Luyten GP, Menezo JL, Sener BA, Tassignon MJ, Termote H, Worst JG. Multicenter study of the Artisan phakic intraocular lens. J Cataract Refract Surg 2000; 26:1163-71. [PMID: 11008043 DOI: 10.1016/s0886-3350(00)00545-9] [Citation(s) in RCA: 216] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE To assess the Artisan intraocular lens to correct myopia in phakic eyes. SETTING European multicenter study sponsored by Ophtec BV, Groningen, The Netherlands. METHODS In this prospective multicenter clinical study, the Artisan lens was implanted in 518 eyes between September 1991 and October 1999. The power of the lenses ranged from -5.0 to -20.0 diopters (D). Follow-up examinations were performed at 6 months and 1, 2, and 3 years. Follow-up ranged from 6 months (n = 454) to 3 years (n = 249). The preoperative uncorrected visual acuity (UCVA) was not recorded but was estimated to be worse than 0.1. The preoperative mean best spectacle-corrected visual acuity (BSCVA) was 0.67 +/- 0.26 (SD). Endothelial cell counts were done at 6 months and 1, 2, and 3 years in a subgroup of 129 eyes. RESULTS A UCVA of 20/40 or better was observed in 76.8% of eyes regardless of the postoperative goal. A BSCVA of 20/40 or better was observed in 93.9% of eyes and remained stable throughout the follow-up. Of the eyes with extremely high myopia (>-15.0 D), 63.3% gained 2 or more lines of BSCVA; of those with moderate myopia (-5.0 to -10.0 D), 23.5% gained 2 or more lines. The mean endothelial cell density change was 4.8% at 6 months, 2.4% at 1 year, 1.7% at 2 years, and 0.7% at 3 years. The incidence of persistent adverse events at 3 years was relatively low. Secondary surgical interventions included repositioning of the lens because of poor initial placement and lens exchange because of preoperative power calculation errors. Glare and halo effects during night driving were noted and were related to large pupils in young patients. CONCLUSION The Artisan lens is a safe, stable, efficacious, and predictable method to correct -5.0 to -20.0 D of myopia. This study suggests that the corneal endothelial cell loss is stabilized to the physiologically normal level after 3 years.
Collapse
|
35
|
Kohnen T, Baumeister M, Magdowski G. Scanning electron microscopic characteristics of phakic intraocular lenses. Ophthalmology 2000; 107:934-9. [PMID: 10811086 DOI: 10.1016/s0161-6420(00)00072-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVE To analyze the surface quality of new generation phakic intraocular lenses (IOLs). DESIGN Experimental materials study. MATERIALS Three different new generation phakic IOLs: angle-fixated anterior chamber lens Chiron Vision NuVita MA20 (polymethylmethacrylate [PMMAD, iris-fixated anterior chamber lens Ophtec Artisan Iris-Claw (PMMA), posterior chamber lens Staar ICM (polymer from porcine collagen and 2-hydroxyethyl methacrylate [HEMA]). METHODS Representative samples of three different phakic IOLs underwent surface and edge-finish examination with light microscopy (LM). The phakic IOLs were then examined by use of scanning electron microscopy (SEM), and particular attention was given to optic surface quality, edge finish, haptic, and optic/haptic junction. RESULTS In all IOLs the LM examination showed a smooth and homogeneous surface. No irregularities, particularly at the optic front and back surface, optic edge, haptic, and the optic/haptic junctions, were detected by SEM. One exception was a minor surface roughness at the claws of an Artisan iris-fixated anterior chamber IOL. CONCLUSIONS Phakic IOLs are implanted either in the anterior or posterior chamber of healthy eyes, and high standards for their surface quality are required. The evaluation of surface properties with LM and SEM did not reveal any defects that contraindicate the implantation of phakic IOLs.
Collapse
Affiliation(s)
- T Kohnen
- Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany
| | | | | |
Collapse
|
36
|
Landesz M, Worst JG, van Rij G. Long-term Results of Correction of High Myopia With an Iris Claw Phakic Intraocular Lens. J Refract Surg 2000; 16:310-6. [PMID: 10832979 DOI: 10.3928/1081-597x-20000501-03] [Citation(s) in RCA: 70] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE Anterior chamber phakic intraocular lenses (PIOLs) are one of the modalities used to correct high myopia. We report the long-term results of our prospective study on the Artisan 5-mm optic myopia lens. METHODS We studied 67 eyes of 38 consecutive patients with preoperative myopia ranging from -5.38 to -28.00 D. All patients were operated by one surgeon. Mean follow-up was 35 months (24 months in 67 eyes and 36 months in 61 eyes). RESULTS In 45 eyes (67.2%), postoperative residual refraction was within +/- 1.00 D of emmetropia. The mean refraction was stable statistically during the entire follow-up period. Mean best spectacle-corrected visual acuity improved from 20/40 to 20/32. Mean endothelial cell loss at 6 months was 5.5% (range, -52.4% to +9.3%), at 12 months, 7.21% (range, -53.2% to +20.1%), at 24 months, 9.1% (range -43.6% to +13.6%), and at 36 months, 10.9% (range, -43.0O% to +11.4%). The majority of eyes had an increase in best spectacle-corrected visual acuity; 5 eyes lost best spectacle-corrected visual acuity. We encountered no major complications. CONCLUSION Implanting the Artisan 5-mm optic myopia lens in high myopic eyes resulted in a stable and accurate refractive outcome. The apparent progressive corneal endothelial cell loss remains a matter of concern.
Collapse
Affiliation(s)
- M Landesz
- Department of Ophthalmology, University Hospital Rotterdam, The Netherlands.
| | | | | |
Collapse
|
37
|
Zaldivar R, Ricur G, Oscherow S. The phakic intraocular lens implant: in-depth focus on posterior chamber phakic IOLs. Curr Opin Ophthalmol 2000; 11:22-34. [PMID: 10724824 DOI: 10.1097/00055735-200002000-00005] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Phakic Intraocular surgery has come a long way in the past 20 years, especially in the evolution of posterior chamber phakic intraocular lenses (PC PIOLs). Clinical trials worldwide are showing acceptable results concerning efficacy, predictability, stability, and safety. PC PIOLS are proving to be a promising option for patients with high and extreme ametropia who cannot benefit from conventional corneal refractive procedures. This article provides an in-depth examination of PC PIOLs, their origin and evolution, and the results of past and current clinical studies. Reports of historical importance and studies published since the 1990s in peer-reviewed journals, textbooks, and monthly eye magazines, as well as Food and Drug Administration preliminary clinical findings, are reviewed. Anterior chamber phakic intraocular lenses are mentioned briefly.
Collapse
Affiliation(s)
- R Zaldivar
- Department of the Refractive and Cataract Surgery Program, Instituto Zaldivar, Mendoza, Argentina.
| | | | | |
Collapse
|
38
|
Zaldivar R, Davidorf JM, Oscherow S. Posterior Chamber Phakic Intraocular Lens for Myopia of -8 to -19 Diopters. J Refract Surg 1998; 14:294-305. [PMID: 9641420 DOI: 10.3928/1081-597x-19980501-13] [Citation(s) in RCA: 168] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in patients with extreme myopia. METHODS We analyzed the results of 124 eyes that received a posterior chamber hydrogel collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of their myopia. The target postoperative spherical equivalent refraction was emmetropia. Mean follow-up was 11 months (range 1 to 36 mo). RESULTS The mean preoperative spherical equivalent refraction was -13.38 +/- 2.23 D (range, -8.50 to -18.63 D). Mean postoperative spherical equivalent refraction at last examination was -0.78 +/- 0.87 D (range, +1.63 to -3.50 D), with 69% (86 eyes) within +/-1.00 D and 44% (55 eyes) within +/-0.50 D of emmetropia. The refraction remained stable with a statistically insignificant change (p > 0.05 at each interval) during follow-up. A gain of two or more lines of spectacle-corrected visual acuity was seen in 36% (45 eyes) at last examination. One eye (0.8%) lost two or more lines of spectacle-corrected visual acuity from a retinal detachment. CONCLUSION Posterior chamber phakic IOL implantation with the Staar Collamer plate lens is an effective and safe method for reducing or correcting myopia between -8 and -19 D. Gains in spectacle-corrected visual acuity were common, and results suggested good refractive stability. Improvements in phakic IOL power calculation formulas are needed to improve the predictability of refractive outcome.
Collapse
|
39
|
Menezo JL, Aviño JA, Cisneros A, Rodriguez-Salvador V, Martinez-Costa R. Iris Claw Phakic Intraocular Lens for High Myopia. J Refract Surg 1997; 13:545-55. [PMID: 9352483 DOI: 10.3928/1081-597x-19970901-11] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND The implantation of a Worst-Fechner iris claw intraocular lens (IOL) is one of the surgical procedures used for the correction of high myopia. This technique reduces myopia with stable refractive results; however, its potential long-term risks have not been evaluated. We report results in 94 eyes with a minimum follow-up of 3 years. METHODS We studied 94 eyes of 62 patients with myopia > or = -7.00 diopters (D) who underwent Worst-Fechner IOL implantation. Lens decentration, permeability of the blood-aqueous barrier by iris angiography, and changes in corneal endothelial density were analyzed. RESULTS Mean follow-up time was 48.9 months (range 36 to 72 mo). Three years after surgery, 58 eyes (61%) had an uncorrected visual acuity > or = 20/40, and 77 eyes (82%) gained two or more lines of spectacle-corrected visual acuity with respect to the preoperative value; 75 eyes (79%) were within +/- 1.00 D of emmetropia and 46 eyes (48%) were within +/- 0.50 D of emmetropia. The mean endothelial cell loss was 17.9% at 5 years after surgery, while the percentage of hexagonality and the coefficient of cell variation tended toward preoperative levels. No vision threatening complications were seen. CONCLUSIONS The implantation of a Worst-Fechner iris claw phakic IOL reduced high myopia with a stable refractive outcome. Endothelial cell damage was within acceptable limits. The absence of major complications makes this procedure an acceptable method for correcting high myopia.
Collapse
Affiliation(s)
- J L Menezo
- La Fe University Hospital, University of Valencia School of Medicine, Department of Ophthalmology, Spain
| | | | | | | | | |
Collapse
|
40
|
Wiechens B, Winter M, Haigis W, Happe W, Behrendt S, Rochels R. Bilateral Cataract after Phakic Posterior Chamber Top Hat-style Silicone Intraocular Lens. J Refract Surg 1997; 13:392-7. [PMID: 9268941 DOI: 10.3928/1081-597x-19970701-17] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND New strategies have been developed for surgical treatment of high myopia. Recently, implantation of minus power posterior chamber intraocular lenses (IOL) into phakic eyes has been introduced. METHODS We report a 37 year-old female patient who developed bilateral anterior subcapsular cataract 7 years after minus-power, top hat-style silicone posterior chamber IOL implantation in Russia. The corrected visual acuity was right eye 20/200 and left eye 20/63. Because of the high myopia and the posterior chamber IOL in her phakic eyes, biometry for IOL calculation gave contradictory results. Both posterior chamber IOLs were found to be adherent to the crystalline lenses. After posterior chamber IOL explantation and phacoemulsification, intraoperative retinoscopy was performed. With this aphakic refraction, the IOL power was calculated and implanted. The explanted posterior chamber IOLs were examined by scanning electron microscopy. RESULTS After bilateral operation the corrected visual acuity increased to right eye 20/32 and left eye 20/40, respectively. On scanning electron microscopy, a membranous structure of unknown origin was noted on the entire surface of the explanted posterior chamber IOLS. CONCLUSION There is a potential risk of cataract formation after implantation of this top hat-style silicone posterior chamber IOL. If cataract extraction in this specific situation is needed, a different approach for calculating the aphakic IOL power is necessary, such as intraoperative retinoscopy.
Collapse
Affiliation(s)
- B Wiechens
- Department of Ophthalmology, Christian-Albrechts-University, Kiel, Germany.
| | | | | | | | | | | |
Collapse
|
41
|
Van Rij G. The happy patient. J Cataract Refract Surg 1997; 23:3. [PMID: 9100091 DOI: 10.1016/s0886-3350(97)80131-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
42
|
Abstract
PURPOSE To examine the safety and efficacy of myopic keratomileusis in situ (automated lamellar keratoplasty) using an automated microkeratome. SETTING Jules Stein Eye Institute and the Department of Ophthalmology, UCLA School of Medicine, Los Angeles, California. METHODS A retrospective study was done on 135 consecutive eyes of 91 patients who had keratomileusis in situ for myopia by one surgeon between October 4, 1993, and February 23, 1995. Mean preoperative myopia was 8.30 +/- 2.50 diopters (D) (range 4.50 to 20.50). Follow-up ranged from 1 (108 eyes) to 6 months (52 eyes). No eye had enhancement surgery before 3 months; eyes were dropped from the study at the time of enhancement. RESULTS Three months after myopic keratomileusis in situ, the mean difference between attempted and achieved correction was an undercorrection of 0.90 +/- 1.50 D; 32 of 83 eyes were within 1.00 D of attempted correction. Forty eyes were undercorrected by more than 1.00 D, and 11 were overcorrected by more than 1.00 D. Uncorrected visual acuity improved to 20/40 or better in 42 of 83 eyes at 3 months. Best spectacle-corrected visual acuity (BSCVA) declined by two or more lines in 8 of 83 eyes at 3 months and 1 of 52 eyes at 6 months. In eyes with 6 months of follow-up, a mean myopic shift of 0.40 D occurred between 3 and 6 months. Two eyes had clinically significant ingrowth into the interface. The variability in outcome (standard deviation in achieved less attempted correction) at 3 months was 1.70 D in the first 45 cases, 1.20 D in the second 45 cases, and 1.10 D in the last 45 cases. CONCLUSION Myopic keratomileusis in situ is relatively effective and safe for the correction of high myopia; however, a mild loss of BSCVA is not uncommon in the early postoperative period. Surgeon experience may be important for refractive accuracy.
Collapse
Affiliation(s)
- E E Manche
- Jules Stein Eye Institute, UCLA School of Medicine, USA
| | | |
Collapse
|
43
|
Krumeich JH, Daniel J, Gast R. Closed-System Technique for Implantation of Iris-Supported Negative-Power Intraocular Lens. J Refract Surg 1996; 12:334-40. [PMID: 8705707 DOI: 10.3928/1081-597x-19960301-06] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND The iris-supported claw lens can reversibly correct a wide range of ametropia and aniseikonia with excellent predictability and stability. However, concerns regarding its potential harm to the corneal endothelium have prevented its widespread use. Our experience with the closed-system surgical technique and the spreader device used in 180 cases between 1987 and 1993 has led us to conclude that potential complications are more likely due to the technique of implantation rather than to the properties of the lens itself. METHOD We conducted a prospective study of 35 eyes of 20 consecutive patients (mean age, 38 years; range, 21 to 55 years) operated on between August 1993 and August 1994. Preoperative spherical equivalent refractions ranged from -6.00 to -21.25 diopters (D) (mean, -12.50 D). Follow up was 6 months (86% of eyes) to 1 year (57% of eyes). Spectacle-corrected visual acuity and endothelial cell density were measured prior to, and 1, 6, and 12 months following lens implantation. All data were analyzed using the paired t-test. RESULTS Mean endothelial cell density dropped insignificantly (p > .10):by 1.22% at 1 month (n = 34), by 2.25% at 6 months (n = 27), and by 1.21% at 12 months (n = 18). Spectacle-corrected visual acuity increased significantly (p < .001): from a mean of 0.61 preoperatively to 0.77 at 1 month, 0.84 at 6 months, and 0.93 at 12 months postoperatively. At 12 months, 15 eyes (75%) had a refraction within +/-0.50 D, 19 eyes (95%) within +/-1.00 D, and 20 eyes (100%) within +/-2.00 D of emmetropia. CONCLUSIONS Our results suggest that the closed-system approach using the spreader device allows safe implantation of the Worst iris-supported claw lens.
Collapse
Affiliation(s)
- J H Krumeich
- Department of Ophthalmology, Martin-Luther-Hospital, Bochum, Germany
| | | | | |
Collapse
|
44
|
Waring GO. Evaluating New Refractive Surgical Procedures: Free Market Madness Versus Regulatory Rigor Mortis. J Refract Surg 1995; 11:335-9. [PMID: 8528910 DOI: 10.3928/1081-597x-19950901-08] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
45
|
Affiliation(s)
- O Ibrahim
- Department of Ophthalmology, El-Maghraby Eye Hospital, Jeddah, Saudi Arabia
| | | |
Collapse
|