1
|
Kohnen T, Kook D, Morral M, Güell JL. Phakic intraocular lenses. J Cataract Refract Surg 2010; 36:2168-94. [DOI: 10.1016/j.jcrs.2010.10.007] [Citation(s) in RCA: 141] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2010] [Revised: 09/01/2010] [Accepted: 09/01/2010] [Indexed: 11/29/2022]
|
2
|
Alfonso JF, Fernández-Vega L, Lisa C, Fernandes P, González-Méijome JM, Montés-Micó R. Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus. J Refract Surg 2010; 25:759-64. [PMID: 20494760 DOI: 10.3928/1081597x-20090813-01] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2007] [Accepted: 10/21/2008] [Indexed: 01/08/2023]
Abstract
PURPOSE To assess the safety, efficacy, stability, and predictability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct myopia and astigmatism in eyes with keratoconus. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS This prospective study comprised keratoconic eyes that had implantation of a toric Intraocular Collamer Lens. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and postoperative complications were evaluated 1, 3, 6, and 12 months postoperatively. RESULTS Preoperatively, the mean spherical equivalent in the 30 eyes (21 patients) was -5.38 diopters (D) +/- 3.26 (SD) (range -13.50 to -0.63 D) and the mean cylinder, -3.48 +/- 1.24 D (range -1.75 to -6.00 D). At 12 months, 86.7% of the eyes were within +/-0.50 D of the attempted refraction and all eyes were within +/-1.00 D. For the astigmatic components J0 and J45, 83.3% of eyes and 86.7% of eyes, respectively, were within +/-0.50 D. The mean Snellen UDVA was 0.81 +/- 0.20 and the mean CDVA, 0.83 +/- 0.18; CDVA was 20/40 or better in 29 eyes 96.7% of eyes and 20/25 or better in 22 eyes (73.3%). No eyes lost more than 2 lines of CDVA; 29 eyes (96.7%) maintained or gained 1 or more lines. The efficacy index was 1.07 and the safety index, 1.16. There were no complications or adverse events. CONCLUSIONS The results confirm that toric ICL implantation is a predictable, effective procedure to correct ametropia in eyes with keratoconus. Predictability and stability were achieved early and remained fairly stable up to 12 months.
Collapse
Affiliation(s)
- José F Alfonso
- Fernández-Vega Ophthalmological Institute, Surgery Department, School of Medicine, University of Oviedo, Oviedo, Spain.
| | | | | | | | | | | |
Collapse
|
3
|
Ozcetin H, Baykara M, Ozmen AT, Yalcinbayir O. Phakic iris-claw IOL implantation, with Bursa technique, through a self-sealing scleral tunnel and without iridotomy or iridectomy. Eur J Ophthalmol 2009; 19:18-23. [PMID: 19123144 DOI: 10.1177/112067210901900103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To present a novel technique for the implantation of phakic iris-claw intraocular lenses (IOL) in highly myopic cases. METHODS Twelve cases, under the age of 40, with high myopia were included in this retrospective study. The mean follow-up span was 14.4+/-5.8 months. Phakic iris-claw IOL implantation was performed, through a 5.5 or 6.5 mm self sealing scleral tunnel with Bursa technique. No suturing and opening a peripheral iridectomy or iridotomy was required in our study. Pre- and postoperative patient evaluation included manifest and cycloplegic refractions, uncorrected visual acuity, best-corrected visual acuity (BCVA), induced astigmatism, and intraocular pressure (IOP) assessments. RESULTS All eyes gained one to nine lines of BCVA of the Snellen chart. The vector analysis revealed an induced astigmatism of 0.63 D. No significant IOP change was detected throughout the follow-up. CONCLUSIONS The data suggest that nonfoldable iris fixated phakic IOL implantation, through a self-sealing incision with Bursa technique, is safe and requires no iridectomy or iridotomy in cases with deep anterior chambers.
Collapse
Affiliation(s)
- H Ozcetin
- Department of Ophthalmology, Uludag University School of Medicine, Bursa, Turkey.
| | | | | | | |
Collapse
|
4
|
Chen LJ, Chang YJ, Kuo JC, Rajagopal R, Azar DT. Metaanalysis of cataract development after phakic intraocular lens surgery. J Cataract Refract Surg 2008; 34:1181-200. [PMID: 18571089 DOI: 10.1016/j.jcrs.2008.03.029] [Citation(s) in RCA: 105] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2007] [Accepted: 03/24/2008] [Indexed: 11/24/2022]
|
5
|
Abstract
PURPOSE To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viscosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer.
Collapse
Affiliation(s)
- Mana Tehrani
- Department of Ophthalmology, Johannes-Gutenberg-University, Mainz, Germany.
| | | |
Collapse
|
6
|
Alió JL, Mulet ME, Gutiérrez R, Galal A. Artisan Toric Phakic Intraocular Lens for Correction of Astigmatism. J Refract Surg 2005; 21:324-31. [PMID: 16128328 DOI: 10.3928/1081-597x-20050701-05] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess the safety and efficacy of implanting Artisan toric phakic intraocular lenses (PIOLs) (Ophtec BV, Groningen, The Netherlands) in eyes with high degrees of compound myopic, hyperopic, and mixed astigmatism. METHODS Twenty-five eyes (20 patients) presenting with high astigmatism were implanted with Artisan toric PIOLs and followed for 1 year. Group 1 included 8 eyes (myopic astigmatism), group 2 included 9 eyes (hyperopic astigmatism), and group 3 included 8 eyes (mixed astigmatism). RESULTS In the myopic astigmatism group, 8 (100%) of 8 eyes had preoperative uncorrected visual acuity (UCVA) of < or = 20/50, and at 6-month follow-up, 5 (62.5%) of 8 eyes had UCVA of > or = 20/40 (P = .005). In this group, 75% of eyes were within +/- 1.00 diopter (D) of the intended correction. In the hyperopic astigmatism group, 8 (88.9%) of 9 eyes had preoperative UCVA of < or = 20/40, and at 6-month follow-up, 6 (66.6%) of 9 eyes had UCVA of > or = 20/32 (P = .199). Approximately 77.8% of eyes were within +/- 1.00 D of the intended correction. In the mixed astigmatism group, 8 (100%) of 8 eyes had preoperative UCVA of < or = 20/50, and at 6-month follow-up, 6 (87.5%) of 8 eyes had UCVA of > or = 20/40 (P = .007). In this group, 87.5% of eyes were within +/- 1.00 D of the intended correction. The safety index of the procedure was 1.6, 1.3, and 1.3 in the myopic, hyperopic, and mixed astigmatism groups, respectively. The efficacy index of the procedure was 1.2, 1.0, and 1.0 in the myopic, hyperopic, and mixed astigmatism groups, respectively. CONCLUSIONS Artisan toric PIOLs are safe for the correction of high degrees of astigmatism associated with myopic or hyperopic spherical refractive defect.
Collapse
Affiliation(s)
- Jorge L Alió
- Vissum/Instituto Oftalmológico Alicante, Department of Refractive Surgery, Miguel Hernández University, Medical School, Alicante, Spain.
| | | | | | | |
Collapse
|
7
|
Güell JL, Vázquez M, Malecaze F, Manero F, Gris O, Velasco F, Hulin H, Pujol J. Artisan toric phakic intraocular lens for the correction of high astigmatism. Am J Ophthalmol 2003; 136:442-7. [PMID: 12967796 DOI: 10.1016/s0002-9394(03)00295-2] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preoperative astigmatism of -3.43 +/- 0.81. The Artisan phakic intraocular lens was inserted in the anterior chamber through a posterior corneal incision; the technique is similar to the implantation of the classical Artisan lens, but in these cases it is particularly important to secure the lens accurately in the correct axis. The main parameters evaluated in this study were uncorrected visual acuity, best-corrected visual acuity, refraction, and endothelial cell count. RESULTS Twelve months after the implantation of the Artisan toric phakic intraocular lens, 62.90% of the eyes were within +/-0.50 diopters. of emmetropia and 96.20% within +/-1.0 diopters. Seventy percent of the eyes gained 1 or more Snellen lines from their preoperative best-corrected visual acuity, and 11.11% lost 1 Snellen line. Mean endothelial cell count increased 2.9%. Mean of the parallel and orthogonal components of cylinder correction were 1.97 diopters and 0.10 diopters, respectively, of the intended cylinder change. The mean of axis alignment error was 10.53 degrees. No serious complications were observed. CONCLUSION Artisan toric phakic intraocular lens implantation appears to be a safe and predictable method for the correction of high levels of astigmatism.
Collapse
Affiliation(s)
- Jose L Güell
- IMO Instituto de Microcirugía Ocular, Barcelona, Spain.
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Dick HB, Alió J, Bianchetti M, Budo C, Christiaans BJ, El-Danasoury MA, Güell JL, Krumeich J, Landesz M, Loureiro F, Luyten GPM, Marinho A, Rahhal MS, Schwenn O, Spirig R, Thomann U, Venter J. Toric phakic intraocular lens: European multicenter study. Ophthalmology 2003; 110:150-62. [PMID: 12511361 DOI: 10.1016/s0161-6420(02)01447-1] [Citation(s) in RCA: 106] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after implantation of Artisan toric phakic intraocular lenses (TPIOLs) for the correction of myopia or hyperopia with astigmatism. DESIGN Prospective, nonrandomized, comparative (self-controlled) multicenter trial. PARTICIPANTS Seventy eyes of 53 patients (mean, 35 years; range, 22-59 years) with preoperative spherical equivalent between +6.50 and -21.25 diopters (D) and cylinder between 1.50 and 7.25 D. METHODS Seventy eyes underwent implantation of a TPIOL with an optical zone of 5.0 mm (Artisan, Ophtec, Groningen, The Netherlands). The dioptric power of the intraocular lens was calculated by considering refraction, keratometry, and anterior chamber depth. The follow-up was 6 months in all cases. Lenses were available in powers ranging from +12.0 D to -23.5 D (spherical equivalent) in 0.5-D increments, with additional cylinder from 1.0 D to 7.0 D, also in 0.5-D increments. MAIN OUTCOME MEASURES The main parameters assessed were best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), refraction, endothelial cell count (ECC), intraocular pressure, slit-lamp biomicroscopy, indirect ophthalmoscopy, subjective complaints, and patient satisfaction. RESULTS Eyes were divided into group A, myopia (n = 48), with an average preoperative spherical equivalent of -8.90 +/- 4.52 D, and group B, hyperopia (n = 22), with an average preoperative spherical equivalent of +3.25 +/- 1.98 D. No eyes in either group experienced a loss in BSCVA, and 46 eyes gained 1 or more lines of their preoperative BSCVA. In 62 eyes (88.6%), UCVA was 20/40 or better. There was a significant reduction in spherical errors and astigmatism in all cases after surgery. All eyes of both groups were within +/-1.00 D of target refraction, and 51 eyes (72.9%) were within +/-0.50 D of target refraction. There was a 4.5% mean total loss of ECC during the first 6 months. No serious complications were observed. Overall patient satisfaction was very high. CONCLUSIONS Six-month clinical trial results demonstrate that implantation of the Artisan TPIOL safely, predictably, and effectively reduced or eliminated high ametropia and astigmatism with one procedure. The refractive effect was stable at 6 months after surgery.
Collapse
Affiliation(s)
- H Burkhard Dick
- Department of Ophthalmology, University of Mainz, Mainz, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
El Danasoury MA, El Maghraby A, Gamali TO. Comparison of iris-fixed Artisan lens implantation with excimer laser in situ keratomileusis in correcting myopia between -9.00 and -19.50 diopters: a randomized study. Ophthalmology 2002; 109:955-64. [PMID: 11986104 DOI: 10.1016/s0161-6420(02)00964-8] [Citation(s) in RCA: 99] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVE To compare Artisan lens implantation with laser in situ keratomileusis (LASIK) for the correction of myopia between -9.00 and -19.50 diopters. DESIGN Prospective randomized clinical trial. PARTICIPANTS Ninety eyes of 61 consecutive patients were enrolled in the study. INTERVENTION Forty-five eyes (50%) received Artisan lens, and 45 eyes (50%) received LASIK; the procedure assigned to each eye was randomized. Eighteen patients (29.5%) received Artisan lens in one eye and LASIK in the other. MAIN OUTCOME MEASURES Slit-lamp microscopy, manifest refraction, uncorrected and spectacle-corrected visual acuity, contrast sensitivity, and specular microscopy were performed before surgery, and 1, 3, 6, and 12 months after surgery. Patient satisfaction and preference were assessed by a subjective questionnaire. RESULTS At 1 year, 43 eyes (95.6%) from the Artisan group and 41 eyes (91.1%) from the LASIK group were examined, the mean spherical equivalent refraction was -0.64 +/- 0.8 diopter in the Artisan eyes and -0.87 +/- 0.8 in the LASIK eyes. The uncorrected visual acuity was 20/20 or better in 9 Artisan eyes (20.9%) and 5 LASIK eyes (12.2%) and 20/40 or better in 38 Artisan eyes (88.4%) and 24 LASIK eyes (58.5%); no Artisan eyes and 5 LASIK eyes (12.2%) lost 2 or more Snellen lines of spectacle-corrected visual acuity. One Artisan eye (2.3%) and six LASIK eyes (14.6%) reported severe night glare; the Artisan lens was exchanged with a larger optic diameter lens. Mean endothelial cell loss at 1 year was 0.7 +/- 1.1 cells/mm(2) in the Artisan eyes and 0.3 +/- 0.9 cells/mm(2) in the LASIK eyes. Contrast sensitivity curve decreased by 2 or more lines in two Artisan (4.7%) and six LASIK eyes (14.6%). Of the 18 patients who received both surgeries, one in each eye, 13 patients (72.2%) preferred the Artisan procedure because of the better quality of vision. CONCLUSIONS In this study, Artisan lens implantation and LASIK were found to be similarly effective, stable, and reasonably safe for the correction of myopia between -9.00 and -19.50 diopters. Better uncorrected and spectacle-corrected visual acuity and contrast sensitivity, a lower enhancement rate, and exchangeability are the main advantages of Artisan lens implantation. Thirteen (72.2%) of the 18 patients who received the Artisan lens in one eye and LASIK in the other preferred the Artisan lens to the LASIK, mainly because of the better quality of vision.
Collapse
Affiliation(s)
- M Alaa El Danasoury
- Magrabi Eye & Ear Center, Abu Dhabi, United Arab Emirates. Magrabi Eye Hospital, Jeddah, Saudi Arabia
| | | | | |
Collapse
|
10
|
Güell JL, Vázquez M, Gris O. Adjustable refractive surgery: 6-mm Artisan lens plus laser in situ keratomileusis for the correction of high myopia. Ophthalmology 2001; 108:945-52. [PMID: 11320026 DOI: 10.1016/s0161-6420(01)00548-6] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To evaluate efficacy, predictability, stability and safety of adjustable refractive surgery (ARS) by combining a phakic intraocular lens (IOL) (Artisan lens 6-mm optical zone [OZ]) and laser in situ keratomileusis (LASIK) (6.5 mm OZ) for the correction of myopia greater than -15.00 diopters (D). DESIGN Noncomparative interventional case series. PARTICIPANTS Twenty-six eyes of 18 patients with a preoperative spherical equivalent between -16.00 and -23.00 D. METHODS First surgery: An 8.5/9.5-mm flap was created and a 6-mm optic iris claw phakic IOL of -15.00 D was inserted in the anterior chamber through a posterior corneal incision. The second surgery was performed once refraction and topography were stable, between 3 and 5 months later. Second surgery: LASIK enhancement (6.5-9.2 OZ); the flap was relifted, and the residual refractive error was corrected. MAIN OUTCOME MEASURES The main parameters in this study were uncorrected visual acuity, best-corrected visual acuity (BCVA), refraction, contrast sensitivity, endothelial cell count (ECC), and subjective response. RESULTS Twenty-eight months after both surgeries, 80.70% of the eyes were within 0.50 D of emmetropia and 100% within 1.0 D. Twenty-six percent of the eyes gained 3 or more lines from their preoperative BCVA, and 42% gained 2 or more lines. There was no visual loss in any eye from 6 weeks to 24 months after LASIK enhancement (second surgery) and refraction, and visual acuities remained stable. Two subjects (11%) had some subjective disturbances at night. There was a 0.61% mean loss of ECC during the first 12 months and a 0.60% loss during the next 16 months. No serious complications were observed. CONCLUSIONS ARS with the combination of a 6-mm optic, 15 D Artisan lens, and LASIK appears to be a safe and highly predictable method for the correction of myopia greater than -15.00 D. It is the best approach with the technology currently available.
Collapse
Affiliation(s)
- J L Güell
- Instituto de Microcirugía Ocular (IMO), Munner 10, 08022 Barcelona, Spain
| | | | | |
Collapse
|
11
|
Abstract
Phakic intraocular lenses have been increasingly popular with refractive surgeons because of the good refractive results achieved and because there are few serious complications. The purpose of this review is to compare the different types of phakic intraocular lenses, regarding implant selection, surgical technique, refractive outcome, and anatomical evaluation. New uses of phakic intraocular lenses are also presented. Although phakic intraocular lenses have gone a long way, the quest for the ideal lens remains a challenge.
Collapse
Affiliation(s)
- A Marinho
- Department of Ophthalmology, University of Pôrto, Portugal
| | | | | |
Collapse
|
12
|
Zaldivar R, Ricur G, Oscherow S. The phakic intraocular lens implant: in-depth focus on posterior chamber phakic IOLs. Curr Opin Ophthalmol 2000; 11:22-34. [PMID: 10724824 DOI: 10.1097/00055735-200002000-00005] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Phakic Intraocular surgery has come a long way in the past 20 years, especially in the evolution of posterior chamber phakic intraocular lenses (PC PIOLs). Clinical trials worldwide are showing acceptable results concerning efficacy, predictability, stability, and safety. PC PIOLS are proving to be a promising option for patients with high and extreme ametropia who cannot benefit from conventional corneal refractive procedures. This article provides an in-depth examination of PC PIOLs, their origin and evolution, and the results of past and current clinical studies. Reports of historical importance and studies published since the 1990s in peer-reviewed journals, textbooks, and monthly eye magazines, as well as Food and Drug Administration preliminary clinical findings, are reviewed. Anterior chamber phakic intraocular lenses are mentioned briefly.
Collapse
Affiliation(s)
- R Zaldivar
- Department of the Refractive and Cataract Surgery Program, Instituto Zaldivar, Mendoza, Argentina.
| | | | | |
Collapse
|
13
|
Boxer Wachler BS, Krueger RR. Agreement and repeatability of pupillometry using videokeratography and infrared devices. J Cataract Refract Surg 2000; 26:35-40. [PMID: 10646144 DOI: 10.1016/s0886-3350(99)00331-4] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE To evaluate the accuracy and repeatability of the pupil-measuring modules of several corneal topography devices. SETTING Department of Ophthalmology, Saint Louis University Eye Institute, St. Louis, Missouri, USA. METHODS In 14 eyes of 7 healthy myopic patients, pupillometry was performed with 3 corneal topography devices and with an infrared pupillometer under luminance-matched conditions for the Placido projection of the topography devices. Pupils were also measured under a mesopic condition. Outcomes were pupil diameters, limits of agreement, and coefficient of repeatability of the topography devices. RESULTS Mean pupil diameter measurements with the Technomed C-Scan, Humphrey Masterview, Alcon EyeMap, and under a mesopic condition were 3.35 mm, 2.96 mm, 2.34 mm, and 5.94 mm, respectively. All pupil diameter measurements differed significantly from one another except those by the Masterview and C-Scan devices. The mean difference between the C-Scan and luminance-matched infrared measurements was 0.74 mm and between the Masterview and luminance-matched infrared measurements, 0.27 mm. The limits of agreement +/- 2 standard deviations was 4.12 mm and 1.56 mm for the C-Scan and Masterview devices, respectively. Coefficients of repeatability were 0.56 mm, 0.46 mm, and 0.44 mm for the C-Scan, Masterview, and EyeMap devices, respectively. CONCLUSIONS Although topography pupillometry was repeatable, it underestimated the largest natural pupil diameter because of the luminance of the Placido rings. The difference in limits of agreement between the C-Scan and Masterview devices may be explained by pupil physiology and the static nature of videokeratoscopy. These results have implications when topography pupillometry is used to assess pupil diameters prior to refractive surgery. We do not recommend using pupil diameters measured by topography to preoperatively determine halo-related safety.
Collapse
|
14
|
Zaldivar R, Davidorf JM, Oscherow S. Posterior Chamber Phakic Intraocular Lens for Myopia of -8 to -19 Diopters. J Refract Surg 1998; 14:294-305. [PMID: 9641420 DOI: 10.3928/1081-597x-19980501-13] [Citation(s) in RCA: 168] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in patients with extreme myopia. METHODS We analyzed the results of 124 eyes that received a posterior chamber hydrogel collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of their myopia. The target postoperative spherical equivalent refraction was emmetropia. Mean follow-up was 11 months (range 1 to 36 mo). RESULTS The mean preoperative spherical equivalent refraction was -13.38 +/- 2.23 D (range, -8.50 to -18.63 D). Mean postoperative spherical equivalent refraction at last examination was -0.78 +/- 0.87 D (range, +1.63 to -3.50 D), with 69% (86 eyes) within +/-1.00 D and 44% (55 eyes) within +/-0.50 D of emmetropia. The refraction remained stable with a statistically insignificant change (p > 0.05 at each interval) during follow-up. A gain of two or more lines of spectacle-corrected visual acuity was seen in 36% (45 eyes) at last examination. One eye (0.8%) lost two or more lines of spectacle-corrected visual acuity from a retinal detachment. CONCLUSION Posterior chamber phakic IOL implantation with the Staar Collamer plate lens is an effective and safe method for reducing or correcting myopia between -8 and -19 D. Gains in spectacle-corrected visual acuity were common, and results suggested good refractive stability. Improvements in phakic IOL power calculation formulas are needed to improve the predictability of refractive outcome.
Collapse
|