1
|
Shahin B, Ojaghi H, Amani F. One-year follow-up of patients with hyperopia undergoing photorefractive keratectomy with Allegretto WaveLight Eye Q 400. J Med Life 2022; 15:489-498. [PMID: 35646175 PMCID: PMC9126459 DOI: 10.25122/jml-2021-0028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 11/15/2021] [Indexed: 11/19/2022] Open
Abstract
This study aimed to examine the effectiveness of photorefractive keratectomy (PRK) in treating patients with cycloplegic hyperopia from +1.00 to +7.00 diopter using Allegretto wave Eye Q 400. This study was conducted on 25 patients with cycloplegic astigmatism ≤1 diopter and cycloplegic hyperopia between +1.00 and +7.00 diopters in 47 eyes, who successively entered into the study within 6 months and underwent PRK. Prior to PRK surgery, all the patients were examined for cycloplegic refraction (astigmatism and hyperopia), slit lamp, keratometry, fundus, and best-corrected (BCVA) and uncorrected visual acuity (UCVA) testing. These examinations were repeated after 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively. The mean preop UCVA of patients was 0.76±0.28 (ranging from 0.00 to 1.3), which reached 0.19±0.22 (ranging from 0.00 to 0.78) one year after the surgery (P=0.000). There was a significant correlation between increasing astigmatism and preop cycloplegic hyperopia >5 diopters (P=0.000), corneal ring haziness at 12th months (P=0.000), and 12 months cycloplegic residual hyperopia ≥2.00 diopters (P=0.000). 53.2% of the eyes (with a mean grade of 2.34) were detected with corneal ring haziness at 12th months, which was significantly correlated with 12 months residual cycloplegic hyperopia of ≥2.00 diopters (P: 0.000) and cycloplegic sphere above 5 diopters (P=0.006). Although the use of photorefractive keratectomy (PRK) with Allegretto Eye Q 400 is associated with a decrease in the mean cycloplegic and improved UCVA and BCVA, its use is not recommended in cases with preop cycloplegic hyperopia above 5 diopters due to the high rate of induction of astigmatism, corneal haziness, and regression of hyperopia.
Collapse
Affiliation(s)
- Behrad Shahin
- Department of Community Medicine, Ardabil University of Medical Sciences, Ardabil, Iran
| | - Habib Ojaghi
- Department of Surgery, Ardabil University of Medical Sciences, Ardabil, Iran,Corresponding Author: Habib Ojaghi, Department of Surgery, Ardabil University of Medical Sciences, Ardabil, Iran. E-mail:
| | - Firouz Amani
- Department of Community Medicine, Ardabil University of Medical Sciences, Ardabil, Iran
| |
Collapse
|
2
|
Salah-Mabed I, Saad A, Gatinel D. Topography of the corneal epithelium and Bowman layer in low to moderately myopic eyes. J Cataract Refract Surg 2016; 42:1190-7. [DOI: 10.1016/j.jcrs.2016.05.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 05/23/2016] [Accepted: 05/24/2016] [Indexed: 10/21/2022]
|
3
|
Reinstein DZ, Gobbe M, Archer TJ, Carp GI. Mechanism for a Rare, Idiosyncratic Complication Following Hyperopic LASIK: Diurnal Shift in Refractive Error Due to Epithelial Thickness Profile Changes. J Refract Surg 2016; 32:364-71. [DOI: 10.3928/1081597x-20160428-05] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 02/04/2016] [Indexed: 11/20/2022]
|
4
|
Cryopreservation of extracted corneal lenticules after small incision lenticule extraction for potential use in human subjects. Cornea 2015; 33:1355-62. [PMID: 25343698 PMCID: PMC4218759 DOI: 10.1097/ico.0000000000000276] [Citation(s) in RCA: 106] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Purpose: To describe the technique of cryopreservation of corneal lenticules extracted after small incision refractive lenticule extraction (ReLEx SMILE) and initial results of femtosecond laser intrastromal lenticular implantation for hyperopia. Methods: Lenticules were collected from patients undergoing ReLEx SMILE for the correction of myopia and subjected to a tissue processing technique and cryopreservation. These lenticules were subsequently used to treat 8 hyperopic eyes and 1 aphakic eye. A femtosecond laser was used to create a pocket into each patient's cornea, followed by implantation of a cryopreserved lenticule. The patients were monitored through follow-up examinations for a mean 155.4 days (38–310 days). Results: The mean interval from storage of lenticules to removal from liquid nitrogen was 96 days (range, 19–178 days). Mean spherical equivalent of hyperopic eyes treated was +4.50 ± 1.1 diopter (D). Mean keratometry and pachymetry changed from preoperative 43.9 D and 531.6 μm to 47.4 D and 605.2 μm, respectively, postoperatively. Mean residual spherical equivalent for hyperopic eyes was +0.6 D and +4.1 D for the aphakic eye. None of the eyes showed evidence of rejection or loss of best-corrected visual acuity at the end of the follow-up period. Conclusions: The cryopreservation technique seems to be a safe method of long-term storage of refractive lenticules extracted after ReLEx SMILE for use in allogeneic human subjects. It may potentially be a safe and effective alternative to excimer laser ablation for hyperopia because of the low risks of regression, haze, flap-related complications, postoperative dry eye, and higher-order aberrations. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: CTRI/2014/01/004331.
Collapse
|
5
|
Astle WF, Huang PT, Ereifej I, Paszuk A. Laser-assisted subepithelial keratectomy for bilateral hyperopia and hyperopic anisometropic amblyopia in children. J Cataract Refract Surg 2010; 36:260-7. [DOI: 10.1016/j.jcrs.2009.08.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2009] [Revised: 06/26/2009] [Accepted: 08/10/2009] [Indexed: 11/29/2022]
Affiliation(s)
- William F Astle
- Alberta Children's Hospital, University of Calgary, 2888 Shaganappi Trail Northwest, Calgary, Alberta T3B 6A8, Canada.
| | | | | | | |
Collapse
|
6
|
Alfonso JF, Fernández-Vega L, Baamonde B, Madrid-Costa D, Montés-Micó R. Refractive lens exchange with spherical diffractive intraocular lens implantation after hyperopic laser in situ keratomileusis. J Cataract Refract Surg 2009; 35:1744-50. [DOI: 10.1016/j.jcrs.2009.04.045] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2009] [Revised: 04/21/2009] [Accepted: 04/24/2009] [Indexed: 10/20/2022]
|
7
|
Wang TJ, Lo W, Hsueh CM, Hsieh MS, Dong CY, Hu FR. Ex vivo multiphoton analysis of rabbit corneal wound healing following conductive keratoplasty. JOURNAL OF BIOMEDICAL OPTICS 2008; 13:034019. [PMID: 18601564 DOI: 10.1117/1.2943156] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Ex vivo multiphoton imaging is used to characterize rabbit corneal wound healing after conductive keratoplasty (CK) procedures. CK is performed on the right eyes from eight New Zealand albino rabbits while the left eyes are punctured by a keratoplast tip without energy application. Rabbits are humanely sacrificed 1 day, 1, 2, and 4 weeks after the CK procedure. Eye balls are enucleated and placed on the microscope for multiphoton imaging. Multiphoton imaging reveals damage of corneal epithelium and stroma caused by the CK procedure and the subsequent wound healing process can be followed without histological procedures. Multiphoton excited autofluorescence images demonstrate that re-epithelilialization is accomplished within 1 week in both CK and control groups. However, epithelial hyperplasia is observed in CK corneas. In addition, stromal wounds in the control group become inconspicuous within 1 week while obvious wounds still exist in CK corneas for at least 4 weeks. Postconductive keratoplasty corneal damage and wound healing can be characterized by multiphoton microscopy without histological procedures. Our results suggest that multiphoton microscopy has potential in the clinical evaluation of corneal damage due to refractive surgery, and can be used to study and reduce the unwanted side effects of these procedures.
Collapse
Affiliation(s)
- Tsung-Jen Wang
- Taipei Medical University Hospital, Department of Ophthalmology, Taipei 110, Taiwan
| | | | | | | | | | | |
Collapse
|
8
|
Gatinel D, Racine L, Hoang-Xuan T. Contribution of the corneal epithelium to anterior corneal topography in patients having myopic photorefractive keratectomy. J Cataract Refract Surg 2007; 33:1860-5. [DOI: 10.1016/j.jcrs.2007.06.041] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2007] [Accepted: 06/11/2007] [Indexed: 10/22/2022]
|
9
|
Asbell P. Is conductive keratoplasty the treatment of choice for presbyopia? EXPERT REVIEW OF OPHTHALMOLOGY 2007. [DOI: 10.1586/17469899.2.1.121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
10
|
Abstract
Surgical attempts to correct hyperopia have yielded varying results over the last 130 years. These techniques include the reshaping of the cornea through incisions, burns, or lamellar cuts with removal of peripheral tissue; the addition of central inlays; laser ablations; and the replacement of the crystalline lens. By examining the success of each surgical technique, the refractive surgeon may be able to make an informed decision on its indications and limitations, based on the specific patient's characteristics. Reporting the outcomes and complications of hyperopic surgery will help refine our approach to the management of an increasingly hyperopic and presbyopic population.
Collapse
Affiliation(s)
- Salomon Esquenazi
- LSU Eye Center and LSU Neuroscience Center, Louisiana State University Health Sciences Center, New Orleans, USA.
| | | | | |
Collapse
|
11
|
Naoumidi TL, Kounis GA, Astyrakakis NI, Tsatsaronis DN, Pallikaris IG. Two-year follow-up of conductive keratoplasty for the treatment of hyperopic astigmatism. J Cataract Refract Surg 2006; 32:732-41. [PMID: 16765788 DOI: 10.1016/j.jcrs.2006.01.062] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2005] [Accepted: 10/13/2005] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the safety, efficacy, predictability, and stability of conductive keratoplasty (CK) for the treatment of hyperopic astigmatism. SETTING University of Crete Medical School, Vardinoyannion Eye Institute of Crete, Heraklion, Greece. METHODS In this prospective nonrandomized noncontrolled single-center study, 47 eyes of 34 patients (15 women and 19 men) were treated for hyperopic astigmatism (up to + 3.50 diopters [D]) with a Refractec ViewPoint CK system and followed for 24 months +/- 0.6 (SD). The treatment consisted of 4 to 36 spots applied to the periphery of the cornea. Mean age was 48.5 years +/- 9.7 years, range 25 to 68 years. All the treated eyes were analyzed for safety, efficacy, predictability, and stability. RESULTS The mean patient age was 48.5 +/- 9.7 years (range 25 to 68 years). Preoperatively, the mean manifest refraction spherical equivalent (MRSE) was +2.11 +/- 0.88 D (range -0.50 to + 4.13 D); at 12 months, it was -0.52 +/- 0.73 D and at 24 months, -0.50 +/- 0.77 D. At 24 months, the mean MRSE was within +/-0.50 D in 61% of eyes, within +/-1.00 D in 83%, and within +/-2.00 D in all eyes. At 24 months, the uncorrected visual acuity was 20/20 or better in 37% of eyes and 20/40 or better in 97%. By the end of the follow-up period, no eye had lost > or =2 Snellen lines or had an induced cylinder > or =1.50 D. CONCLUSIONS Conductive keratoplasty for low hyperopic astigmatism was a safe, effective, and stable procedure. Nomogram adjustments and careful patient selection should contribute to higher levels of predictability when treating hyperopic astigmatism.
Collapse
Affiliation(s)
- Tatiana L Naoumidi
- University of Crete Medical School, Vardinoyannion Eye Institute of Crete, Heraklion, Greece.
| | | | | | | | | |
Collapse
|
12
|
Pallikaris IG, Naoumidi TL, Astyrakakis NI. Long-term results of conductive keratoplasty for low to moderate hyperopia. J Cataract Refract Surg 2005; 31:1520-9. [PMID: 16129286 DOI: 10.1016/j.jcrs.2005.01.032] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/12/2005] [Indexed: 11/24/2022]
Abstract
PURPOSE To assess the long-term safety, efficacy, predictability, and stability of conductive keratoplasty (CK) for the treatment of low to moderate hyperopia and to evaluate the impact of the procedure on the quality of vision. SETTING University of Crete, Medical School, Vardinoyannion Eye Institute of Crete, Crete, Greece. METHODS In this prospective nonrandomized noncontrolled single-center study, 38 eyes of 26 patients (13 women and 13 men) were treated for hyperopia with a Refractec ViewPoint CK system and followed for 30 months. Preoperatively, the mean manifest refraction spherical equivalent (MRSE) was +1.89 diopters (D) +/- 0.6 (SD) (range +1.00 to +3.25 D), and the mean follow-up was 30.9 +/- 1.1 months. All eyes were treated with the regular CK nomogram for the treatment of spherical hyperopia. The treatment consisted of 8 to 32 spots applied to the periphery of the cornea. Mean age was 50.3 +/- 8.8 years (range 31 to 71 years). All treated eyes were analyzed for safety, efficacy, predictability, and stability. RESULTS At 12 months, the MRSE was -0.06 +/- 0.8 D and at 30 months was -0.02 +/- 0.7 D. At 30 months, the mean MRSE was within +/-0.50 D in 68%, within +/-1.00 D in 92%, and within +/-2.00 D in all eyes. At 30 months, uncorrected visual acuity was 20/20 or better in 52.5% and 20/40 or better in 89% of eyes. No eye lost 2 or more Snellen lines or had an induced cylinder of 2.00 D or greater. The procedure did not cause statistically significant changes in contrast sensitivity. CONCLUSION Results show that CK for low to moderate hyperopia is a safe, effective, predictable, and stable procedure.
Collapse
Affiliation(s)
- Ioannis G Pallikaris
- University of Crete, Medical School, Vardinoyannion Eye Institute of Crete, Heraklion, Greece
| | | | | |
Collapse
|
13
|
Autrata R, Rehurek J. Laser-assisted subepithelial keratectomy and photorefractive keratectomy for the correction of hyperopia: Results of a 2-year follow-up. J Cataract Refract Surg 2003; 29:2105-14. [PMID: 14670418 DOI: 10.1016/s0886-3350(03)00415-2] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate and compare the efficacy, safety, predictability, and stability of laser-assisted subepithelial keratectomy (LASEK) and photorefractive keratectomy (PRK) for low to moderate hyperopia with a 2-year follow-up. SETTING Department of Ophthalmology, Masaryk University Hospital, Brno, Czech Republic. METHODS This prospective comparative single-surgeon study included 216 eyes of 108 patients with hyperopia who received PRK in 1 eye and LASEK in the contralateral eye. The mean patient age was 38.3 years (range 25 to 58 years). The mean preoperative spherical equivalent (SE) cycloplegic refraction was +3.67 diopters (D) +/- 1.15 (SD) (range +2.00 to +5.00 D), and astigmatism was less than 1.00 D. In each patient, PRK was performed in 1 eye (Group A) and LASEK was performed in the other eye (Group B) using the Nidek EC-5000 excimer laser. Postoperative uncorrected visual acuity (UCVA), best corrected visual acuity, contrast sensitivity, manifest and cycloplegic refractions, refractive stability and predictability, postoperative pain, and corneal haze were examined and statistically analyzed. A P value less than 0.05 was considered significant. RESULTS At 1 week, the UCVA was 20/40 or better in 58% of PRK eyes and 85% of LASEK eyes (P =.037); at 2 years, it was 20/40 or better in 81% and 91%, respectively (P =.076). At 2 years, the UCVA for near was N8 or better in 73% of PRK eyes and 89% of LASEK eyes (P =.064). No patient lost 2 or more lines of Snellen visual acuity. The safety index was 1.03 in PRK eyes and 1.08 in LASEK eyes. Refractive stability was achieved at 6 months in LASEK eyes and at 12 months in PRK eyes. The mean SE cycloplegic refraction decreased from +3.58 D (PRK eyes) and +3.76 D (LASEK eyes) at baseline to +0.74 D and +0.32 D, respectively, at 2 years; in 57% and 78% of eyes, respectively, the refraction was within +/-0.50 D of the targeted refraction. Peripheral corneal haze scores at 3 to 9 months and pain scores at 1 to 3 days were significantly lower in the LASEK group than in the PRK group. CONCLUSIONS Laser-assisted subepithelial keratectomy for hyperopia up to +5.00 D provided good visual and refractive results. It significantly reduced postoperative pain, grade of peripheral ring-shaped corneal haze, and regression of hyperopia. Hyperopic LASEK provided quicker visual recovery and achieved better efficacy, predictability, and refractive stability than hyperopic PRK.
Collapse
Affiliation(s)
- Rudolf Autrata
- Department of Ophthalmology, Masaryk University Hospital, Brno, Czech Republic.
| | | |
Collapse
|
14
|
Zadok D, Raifkup F, Landau D, Frucht-Pery J. Long-term evaluation of hyperopic laser in situ keratomileusis. J Cataract Refract Surg 2003; 29:2181-8. [PMID: 14670429 DOI: 10.1016/s0886-3350(03)00416-4] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE To evaluate the efficacy, safety, and predictability of hyperopic laser in situ keratomileusis (H-LASIK). SETTING Departments of Ophthalmology, Hadassah University Hospital, Jerusalem, and Assaf Harofeh Medical Center, Zerifin, Israel. METHODS This prospective noncomparative case series studied the results of H-LASIK in the first 92 consecutive eyes of 50 patients with up to +10.25 diopters (D) of hyperopia. For analysis, the patients were divided into 3 groups based on preoperative hyperopia: low hyperopia (< +3.00 D), moderate hyperopia (> or = +3.00 to 6.00 D), and high hyperopia (> or = +6.00 D). RESULTS Forty-two patients, 77 eyes (83.7%), were followed for at least 12 months. At 12 months, the mean manifest spherical equivalent was +0.33 +/- 0.65 D (93.1% of eyes within +/-1.0 D of the intended correction) in the low myopia group, +0.21 +/- 0.60 D (92.3% within +/-1.0 D of the intended correction) in the moderate hyperopia group, and +1.62 +/- 1.50 D (36.4% within +/-1.0 D of the intended correction) in the high hyperopia group. The uncorrected visual acuity (UCVA) was 20/40 or better in all eyes (100%), 24 eyes (92.3%), and 13 eyes (59.1%) in the low, moderate, and high hyperopia groups, respectively. Comparing the UCVA at the last examination with the best corrected visual acuity (BCVA) before surgery in all patients showed that 59 eyes (76.6%) were within +/-1 line and 18 eyes (23.4%) were within +/-2 or more lines of the preoperative BCVA. Three eyes (3.9%) in the high hyperopia group lost 2 or more lines of BCVA. Three eyes (3.9%) had flap- related complications. Eight patients (15 eyes) with a follow-up less than 12 months did not have intraoperative or postoperative complications. CONCLUSION Laser in situ keratomileusis was a safe, effective, and predictable procedure for hyperopia up to +6.0 D and less predictable for higher hyperopia.
Collapse
Affiliation(s)
- David Zadok
- Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, Israel
| | | | | | | |
Collapse
|
15
|
Pallikaris LG, Naoumidi TL, Panagopoulou SI, Alegakis AK, Astyrakakis NI. Conductive Keratoplasty for Low to Moderate Hyperopia: 1-year Results. J Refract Surg 2003; 19:496-506. [PMID: 14518738 DOI: 10.3928/1081-597x-20030901-04] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess the safety, efficacy, and stability of conductive keratoplasty in the treatment of low to moderate hyperopia and evaluate the impact of the procedure on the quality of vision. METHODS Thirty-six eyes (25 patients; 13 female and 12 male) were treated for hyperopia up to +3.25 D with a Refractec ViewPoint CK system and followed for 1 year. Mean age was 50.2 +/- 8.7 years (range 31 to 71). RESULTS Before surgery, mean spherical equivalent refraction was +1.90 +/- 0.60 D (range +1.00 to +3.25 D), decreasing at 1 year after conductive keratoplasty to -0.06 +/- 0.80 D, and was within +/- 0.50 D of emmetropia in 68% (24 eyes) and within +/- 2.00 D in all eyes. Twelve months after conductive keratoplasty, uncorrected visual acuity was 20/20 or better in 19 eyes (50%) and 20/40 or better in 32 eyes (89%). No eye lost > or = 2 Snellen lines or had induced cylinder > or = 2.00 D. The mean root mean square values for higher order optical aberrations were 0.060 +/- 0.039 before and 0.174 +/- 0.170 at 3 months after surgery. No statistically significant changes in contrast sensitivity were noted. CONCLUSIONS Conductive keratoplasty for low to moderate hyperopia provided safe, effective, and stable results both in refraction and quality of vision.
Collapse
Affiliation(s)
- loannis G Pallikaris
- University of Crete, Medical School, Vardinoyannion Eye Institute of Crete, Heraklion, Greece
| | | | | | | | | |
Collapse
|
16
|
Hardten DR, Hauswirth SG. Comparison of designs of laser systems utilized for refractive surgery. Curr Opin Ophthalmol 2003; 14:213-9. [PMID: 12888720 DOI: 10.1097/00055735-200308000-00008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Several different laser types are available on the market for the practitioner to use in refractive surgery. Each laser type has certain parameters that the surgeon must understand to obtain the best refractive outcomes. Studies published in peer-reviewed literature between February 2002 and March 2003 show that refractive results across all types of lasers have improved compared with those of several years ago. A difference in refractive outcomes between lasers is impossible to directly compare, as there are no randomized studies that hold surgeon or patient characteristics constant.
Collapse
Affiliation(s)
- David R Hardten
- Minnesota Eye Consultants, P.A. 710 East 24th Street, Suite 106, Minneapolis, MN 55404, USA.
| | | |
Collapse
|
17
|
El-Agha MSH, Johnston EW, Bowman RW, Cavanagh HD, McCulley JP. Photorefractive keratectomy versus laser in situ keratomileusis for the treatment of spherical hyperopia. Eye Contact Lens 2003; 29:31-7. [PMID: 12769154 DOI: 10.1097/00140068-200301000-00009] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To compare photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) in treating spherical hyperopia using the VISX STAR S2 excimer laser. INTERVENTION Fifteen consecutive eyes of 15 patients underwent PRK, and 16 consecutive eyes of 16 patients underwent LASIK (follow-up: 12 months). MAIN OUTCOME MEASURES Postoperative pain, uncorrected visual acuity (UCVA), deviation from intended correction, and loss of best spectacle-corrected visual acuity (BSCVA). RESULTS Mean preoperative spherical equivalent was + 2.18 diopter [D] for PRK and + 2.03D for LASIK. All PRK patients experienced significant postoperative pain that required systemic medication, whereas LASIK patients had minor and transient discomfort. Mean deviation from intended correction was -0.83D, + 0.01D, and + 0.18D at 1, 6, and 12 months after PRK, and + 0.22D, +0.30D, and + 0.40D at 1, 6, and 12 months after LASIK (P = 0.002 at 1 month). A higher proportion of LASIK eyes had a UCVA of 20/20 or better at all time points (P = 0.013 and 0.025 at 1 and 3 months, respectively). There was no statistically significant difference between both groups in BSCVA loss. CONCLUSIONS LASIK and PRK are comparable in efficacy and safety. However, PRK was more painful, with an initial and temporary myopic over-correction that did not occur after LASIK. Stability was achieved between 3 and 6 months following PRK, and one month following LASIK.
Collapse
Affiliation(s)
- Mohamed-Sameh H El-Agha
- Department of Ophthalmology, The University of Texas Southwestern Medical Center at Dallas, USA
| | | | | | | | | |
Collapse
|
18
|
Alió JL, Mulet ME, Shalaby AMM. Artisan Phakic Iris Claw Intraocular Lens for High Primary and Secondary Hyperopia. J Refract Surg 2002; 18:697-707. [PMID: 12458863 DOI: 10.3928/1081-597x-20021101-06] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the efficacy, predictability, and safety of the Artisan iris claw phakic intraocular lens for the correction of high primary and secondary hyperopia. METHODS Fifty-seven eyes were divided into two groups: 29 eyes had primary hyperopia (mean refraction 6.06 +/- 1.26 D, and 28 eyes had secondary hyperopia, (mean refraction 5.88 +/- 1.88 D) induced or residual following a previous corneal refractive procedure. Consecutive implantation of the Artisan iris claw phakic intraocular lens was performed. Main outcome measures recorded were BSCVA, UCVA, refraction, and astigmatic change, intraocular inflammation, and endothelial cell loss. RESULTS Primary hyperopic group: Preoperatively, mean UCVA was 0.4 +/- 0.7 and mean BSCVA was 0.2 +/- 0.6. After implantation, mean UCVA was 0.3 +/- 0.6 and BSCVA was 0.1 +/- 0.6. Mean cycloplegic residual spherical refractive error after surgery was 0.10 +/- 0.57 D (range -1 to +2 D). Mean surgically induced astigmatism was 1.48 +/- 0.89 D. Safety index was 1.11. Efficacy index was 0.83. Secondary hyperopic group: Preoperatively, mean UCVA was 0.5 +/- 0.7 and mean BSCVA was 0.2 +/- 0.6. Postoperatively, mean UCVA was 0.4 +/- 0.7 and mean BSCVA was 0.2 +/- 0.6. Mean cycloplegic residual spherical refractive error was 0.55 +/- 1.49 D. Mean surgically induced astigmatism was 1.85 +/- 1.19 D. Safety index was 1.05. Efficacy index was 0.7. Postoperative iridocyclitis was observed in one eye (3.4%) in the primary group and in three eyes (10.7%) in the secondary group. Overall corneal endothelial cell loss at 1 year of follow-up was 9.4%. CONCLUSION The Artisan iris claw phakic intraocular lens was reasonably safe and predictable for correcting high hyperopia.
Collapse
Affiliation(s)
- Jorge L Alió
- Instituto Oftalmológico de Alicante (Department of Refractive Surgery), Miguel Hernández University, Medical School, Alicante, Spain.
| | | | | |
Collapse
|
19
|
Hoyos JE, Dementiev DD, Cigales M, Hoyos-Chacón J, Hoffer KJ. Phakic refractive lens experience in Spain. J Cataract Refract Surg 2002; 28:1939-46. [PMID: 12457666 DOI: 10.1016/s0886-3350(02)01439-6] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the efficacy, predictability, and safety of a phakic refractive lens (PRL) for high myopia and hyperopia. SETTING Instituto Oftalmológico Hoyos, Barcelona, Spain. METHODS A PRL was implanted in 31 eyes (17 myopic, 14 hyperopic) with a mean preoperative spherical equivalent (SE) of -18.46 diopters (D) (range -11.85 to -26.00 D) for myopia and +7.77 D (range +5.25 to +11.00 D) for hyperopia. All eyes had a thorough ophthalmologic examination before and after surgery. The follow-up was at least 12 months. RESULTS At 1 year, the mean postoperative SE in the myopic group was -0.22 D +/- 0.87 (SD) and 82% were within +/-1.00 D of the desired refraction. The mean postoperative SE in the hyperopic group was -0.38 +/- 0.82 D, and 79% were within +/-1.00 D. Snellen lines of visual acuity were gained in 65% of the myopic eyes (8 eyes gained 1 line, 3 eyes gained 2 lines), and no eye lost lines. In the hyperopic group, 1 eye gained 1 line of acuity and 1 eye lost 1 line. In the hyperopic group, complications included pupillary block in 2 eyes and pigment dispersion signs without intraocular hypertension in 1 eye. In the myopic group, 1 eye had a corticosteroid-induced intraocular pressure rise, 1 eye had a spot of anterior cortical lens opacity immediately after surgery that did not progress, and 3 eyes with the PRL model 100 had decentration that required replacement of the lens. Four patients (2 myopic, 2 hyperopic) reported night halos in both eyes. CONCLUSIONS Results indicate that PRL implantation to correct high myopia and hyperopia is a relatively rapid, safe, predictable, and stable method that in many cases also improves the best corrected visual acuity. Complications such as visually significant progressive cataract and pigmentary glaucoma were not observed.
Collapse
|
20
|
McDonald MB, Hersh PS, Manche EE, Maloney RK, Davidorf J, Sabry M. Conductive keratoplasty for the correction of low to moderate hyperopia: U.S. clinical trial 1-year results on 355 eyes. Ophthalmology 2002; 109:1978-89; discussion 1989-90. [PMID: 12414402 DOI: 10.1016/s0161-6420(02)01255-1] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE To document the 1-year safety, efficacy, and stability results of 355 eyes treated in the multicenter study of conductive keratoplasty (CK) used to correct low to moderate hyperopia. DESIGN Nonrandomized comparative (self-controlled) trial. PARTICIPANTS Twenty surgeons at 13 centers performed CK on the eyes of all patients enrolled in a multicenter, 2-year, U.S. phase III clinical trial. Treated eyes had +0.75 to +3.00 diopters (D) of hyperopia and < or =0.75 D of cylinder. Patients were 40 years of age or older. INTERVENTION Low-energy, high-frequency current was applied directly into the peripheral corneal stroma through a delivery tip inserted at 8 to 32 treatment spots. The number of treatment spots was increased for increasing levels of hyperopia, but the amount of radiofrequency energy remained constant. Emmetropia was intended. All eyes were treated once (there were no retreatments). MAIN OUTCOME MEASURES Data from 355 eyes with 1 year of follow-up were analyzed for safety and stability, and data from 318 eyes were analyzed for efficacy and predictability, as well as stability and safety. All patients reported on satisfaction and quality of vision after surgery. RESULTS At 1 year, uncorrected visual acuity was < or =20/20 in 56%, < or =20/25 in 75%, and < or =20/40 in 92% of eyes. The manifest refractive spherical equivalent refraction was within 0.50 D in 63%, within +/-1.00 D in 89%, and within +/-2.00 D in 99%. Seven of 355 eyes lost 2 lines of best spectacle-corrected visual acuity at 1 year, but no eye lost >2 lines. One eye of 355 had induced cylinder of >2.00 D. The cycloplegic refractive spherical equivalent changed a mean of 0.25 +/- 0.50 D between months 3 and 6, 0.11 +/- 0.41 D between months 6 and 9, and 0.11 +/- 0.35 D between months 9 and 12. Refractive stability seemed to be attained by 6 months and remained stable through 12 months. Histology and confocal microscopy showed deep penetration of the treatment into the stroma. Endothelial cell counts were not changed by the treatment. CONCLUSIONS CK seems to be safe, effective, and stable for correcting low to moderate spherical hyperopia in patients 40 years old or older. Treatment penetration is deep and cylindrical in shape, and it does not damage the corneal endothelium. Uncorrected visual acuity, predictability, and stability are as good as or better than those obtained with other techniques used to correct hyperopia.
Collapse
|
21
|
Hoyos JE, Cigales M, Hoyos-Chacón J, Ferrer J, Maldonado-Bas A. Hyperopic laser in situ keratomileusis for refractive accommodative esotropia. J Cataract Refract Surg 2002; 28:1522-9. [PMID: 12231305 DOI: 10.1016/s0886-3350(02)01433-5] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To assess the efficacy of hyperopic laser in situ keratomileusis (LASIK) in creating orthophoria without optical correction in adult patients with refractive accommodative esotropia (RAE). SETTING Instituto Oftalmológico de Sabadell, Sabadell, Barcelona, Spain. METHODS This prospective single-center clinical trial studied 9 eyes (18 patients) with RAE having hyperopic LASIK. The mean follow-up was 20 months (range 12 to 24 months). The mean preoperative refraction was +5.01 diopters (D) and the mean deviation angle without optical correction, 36 prism diopters. The intervention was hyperopic LASIK using the Automated Corneal Shaper microkeratome (Bausch & Lomb) and the Apollo broad-beam excimer laser using a 5.5 mm optical zone and an 8.0 mm transition zone; astigmatism was treated by steepening the flattest meridian. RESULTS All patients achieved orthophoria or the preoperative microtropia without optical correction immediately after surgery. This was maintained throughout the follow-up. Fifty-six percent of all cases were within +/-0.5 D of emmetropia, and 89% were within +/-1.0 D. The uncorrected visual acuity improved significantly (P <.005), especially at near, and the mean best corrected visual acuity (BCVA) was maintained, although 4 eyes (22%) lost 1 line of BCVA. There were no significant complications. CONCLUSIONS In adult patients with RAE, treatment of the refractive error using hyperopic LASIK was safe and effective and corrected the esodeviation. Further studies in younger patients will help determine the age at which this intervention may be indicated.
Collapse
|
22
|
Nagy ZZ, Munkácsy G, Popper M. Photorefractive Keratectomy Using the Meditec MEL 70 G-scan Laser for Hyperopia and Hyperopic Astigmatism. J Refract Surg 2002; 18:542-50. [PMID: 12361155 DOI: 10.3928/1081-597x-20020901-09] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the results of photorefractive keratectomy (PRK) using Gaussian flying spot technology in the treatment of hyperopia and hyperopic astigmatism. METHODS Two hundred eyes were evaluated with 12-month follow-up. An Asclepion-Meditec MEL 70 G-scan flying spot ArF excimer laser with a Gaussian scanner was used (6.0-mm treatment zone and 9.0-mm transition zone). Eyes were divided into four groups: Group 1 (spherical hyperopia up to +3.50 D and astigmatism less than 1.00 D, n=62); Group 2 (hyperopia up to +3.50 D and astigmatism of 1.00 D or more, n=44); Group 3 (hyperopia greater than +3.50 D and astigmatism less than 1.00 D, n=56); and Group 4 (hyperopia greater than +3.50 D and astigmatism of 1.00 D or more, n=38). RESULTS In Group 1, 82.2% (51/62 eyes) were within +/-0.50 D of target refraction; 88.7% (55/62 eyes) had 20/20 or better uncorrected visual acuity; 1.6% (1/62 eye) lost two or more lines, 3.2% (2/62 eyes) gained two or more lines of spectacle-corrected visual acuity. In Group 2, 68.1% (30/44 eyes) were within +/-0.50 D; 77.2% (34/44 eyes) had 20/20 or better uncorrected visual acuity; 9.1% (4/44 eyes) lost two or more lines of spectacle-corrected visual acuity. In Group 3, 76.8% (43/56 eyes) were within +/-0.50 D; 78.6% (44/56 eyes) had 20/20 or better uncorrected visual acuity; 5.4% (3/56 eyes) lost two or more lines of spectacle-corrected visual acuity. In Group 4, 42% (16/38 eyes) were within +/-0.50 D; 60.5% (23/38 eyes) had 20/20 or better uncorrected visual acuity; 15.8% (6/38 eyes) lost two or more Snellen lines. CONCLUSION PRK with the flying spot Meditec MEL 70 G-scan was most safe and effective for low hyperopia.
Collapse
Affiliation(s)
- Zoltán Z Nagy
- 1st Department of Ophthalmology, Semmelweis University, Budapest, Hungary
| | | | | |
Collapse
|
23
|
Nagy ZZ, Palágyi-Deak I, Kovács A, Kelemen E, Förster W. First Results With Wavefront-guided Photorefractive Keratectomy for Hyperopia. J Refract Surg 2002; 18:S620-3. [PMID: 12361169 DOI: 10.3928/1081-597x-20020901-24] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the results of traditional laser photoablation and wavefront-supported customized ablation (WASCA) in hyperopic photorefractive keratectomy (H-PRK). METHODS This was a prospective study, comparing two treatment groups, each comprising 40 eyes of 20 patients. Wavefront aberrations were examined using a Shack-Hartmann aberrometer. Preoperative refraction was similar in the two groups; in the traditional H-PRK group (Group 1) it was +3.10 +/- 0.85 D, and in the WASCA-guided group (Group 2) it was +2.90 +/- 0.80 D. H-PRK was performed with the Asclepion-Meditec MEL 70 flying-spot excimer laser. The follow-up time was 6 months. RESULTS In Group 1, mean postoperative refraction was +0.14 +/- 0.24 D, and in Group 2, -0.10 +/- 0.25 D; mean uncorrected visual acuity was 0.92 +/- 0.16 in Group 1 and 0.95 +/- 0.18 in Group 2. Mean best spectacle-corrected visual acuity was 0.96 +/- 0.04 in Group 1 and 1.06 +/- 0.13 in Group 2. In Group 1, 67.5% (27 of 40 eyes), and in Group 2, 85% (34 of 40 eyes) were within +/-0.50 D of target refraction. Regarding change of spectacle-corrected visual acuity in Group 1, 5% (2 of 40 eyes), and in Group 2, 20% (8 of 40 eyes) gained one Snellen line compared to the preoperative; in Group 1, 10% (4 of 40 eyes), and in Group 2, 12.5% (5 of 40 eyes) lost two Snellen lines. In Group 2, the root mean square value for the higher order aberration increased from the initial 0.134 to 0.257 microm at 6 months after surgery. CONCLUSIONS WASCA-guided hyperopic-PRK treatment was found to be safe and predictable. The results were better than those achieved with traditional PRK performed using the same flying-spot type excimer laser.
Collapse
Affiliation(s)
- Zoltán Z Nagy
- 1st Department of Ophthalmology, Semmelweis University, Budapest, Hungary
| | | | | | | | | |
Collapse
|
24
|
Stidham DB, Borissova O, Borissov V, Prager TC. Effect of hyperopic laser in situ keratomileusis on ocular alignment and stereopsis in patients with accommodative esotropia. Ophthalmology 2002; 109:1148-53. [PMID: 12045058 DOI: 10.1016/s0161-6420(02)01031-x] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To evaluate the effect of laser in situ keratomileusis (LASIK) on ocular alignment and stereopsis in patients with accommodative esotropia. DESIGN Retrospective, non-comparative, interventional case series. PARTICIPANTS Since 1998, 27 patients (mean age, 33.3 years; range, 10-52 years) with comitant esophoria or esotropia and hyperopia meeting eligibility requirements underwent bilateral LASIK for correction of refractive error. INTERVENTION Bilateral hyperopic LASIK was performed using the Technolas Keracor 217 excimer laser (Bausch & Lomb) in 22 patients and using the Nidek 5000 excimer laser in 5 patients. MAIN OUTCOME MEASURES Visual acuity (best-corrected and uncorrected), refractive error, ocular alignment, and stereopsis were recorded before and after LASIK. Log transformation of each visual acuity was done before data analysis. RESULTS Using paired t tests, the mean uncorrected esotropia was significantly reduced from 9.0 prism diopters (PD) (range, 0 [esophoria only] to 20 PD; standard deviation [SD], 7.39) before surgery to 3.3 PD (range, 0-15 PD; SD, 6.20) after surgery (P < 0.0001). Most patients (14 patients, 58%) had a reduction in esodeviation after LASIK, but 10 patients (42%) had no response to surgery, and these patients could not be predicted on the basis of preoperative sensorimotor testing. No patient had a worsening sensorimotor status after LASIK. Nine patients subsequently underwent conventional eye muscle surgery. CONCLUSIONS Hyperopic LASIK was effective in reducing the mean uncorrected esotropia in this group of patients. However, accurately determining those patients most likely to benefit from the procedure was difficult.
Collapse
Affiliation(s)
- D Brian Stidham
- Department of Ophthalmology and Visual Sciences, The University of Texas-Houston Medical School, Houston, Texas, USA
| | | | | | | |
Collapse
|
25
|
McDonald MB, Davidorf J, Maloney RK, Manche EE, Hersh P. Conductive keratoplasty for the correction of low to moderate hyperopia: 1-year results on the first 54 eyes. Ophthalmology 2002; 109:637-49; discussion 649-50. [PMID: 11927418 DOI: 10.1016/s0161-6420(01)01022-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVE To document the 1-year postoperative clinical results of the safety, efficacy, and stability of conductive keratoplasty (CK) to correct low to moderate hyperopia. DESIGN Prospective, nonrandomized, self-controlled trial. PARTICIPANTS Five surgeons at four centers performed CK on the first 54 eyes of a multicenter, 2-year clinical trial. Treated eyes had +0.875 to +4.00 diopters (D) of hyperopia and < or =0.75 D of cylinder. The nature of this procedure was explained to all participating patients who signed informed consent forms prior to undergoing the procedure. INTERVENTION Low energy, high-frequency current was applied directly into the peripheral corneal stroma through a delivery tip inserted at 16 or more treatment spots. An early nomogram was used for the first 54 eyes with an intended refraction of plano. MAIN OUTCOME MEASURES Data from all 54 eyes were analyzed for safety and stability. A subset of 30 of the 54 eyes was found that had been treated with the appropriate number of spots with the early nomogram. These eyes were categorized as current nomogram eyes; the data for these eyes were analyzed for efficacy and predictability, as well as stability and safety. All patients reported on satisfaction and quality of vision after surgery. RESULTS Preoperatively, the manifest refractive spherical equivalent refraction (MRSE) of the 30 current nomogram eyes was +1.57 D. At 1 year postoperatively, uncorrected visual acuity was 20/20 or better in 57% of the eyes and 20/40 or better in 93%. The MRSE was within 0.50 D in 46%, within +/-1.00 D in 93%, and within +/-2.00 D in 100%. No eye lost > or =2 lines of best spectacle-corrected visual acuity at 1 year postoperatively nor had an induced cylinder of > or =2.00 D. The MRSE changed a mean of 0.25 D +/- 0.43 between 3 and 6 postoperative months, 0.16 D +/- 0.38 between 6 and 9 postoperative months, and 0.07 D +/- 0.38 between 9 and 12 postoperative months. Refractive stability appeared to be attained by 6 months postoperatively. CONCLUSIONS Conductive keratoplasty appears to be safe, effective, and stable for correcting low to moderate spherical hyperopia. Stability appeared by the 6-month follow-up visit. For the eyes treated with the current CK nomogram, uncorrected visual acuity, predictability, and stability are as good as or better than those obtained with hyperopic laser in situ keratomileusis or noncontact laser thermal keratoplasty.
Collapse
|
26
|
Stevens JD, Ficker LA. Results of Photorefractive Keratectomy for Hyperopia Using the VISX Star Excimer Laser System. J Refract Surg 2002; 18:30-6. [PMID: 11828904 DOI: 10.3928/1081-597x-20020101-04] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate safety, efficacy, and predictability of photorefractive keratectomy (PRK) for hyperopic astigmatism of +1.75 to 00 D manifest refractive sphere and up to -2.50 D manifest refractive astigmatism using the VISX Star excimer laser system, version 2.5 software. METHODS Treatment was performed on 32 eyes of 21 patients. Eighteen of 21 patients were 45 years of age or older. Manifest and cycloplegic refraction together with Pelli-Robson contrast sensitivity assessment was performed prior to surgery and 1, 3, 6, 12, and 24 months after treatment. RESULTS Twenty-seven of 32 surgical procedures were reviewed 1 year after treatment (84%). Corneal epithelial healing was complete between day 4 and 10. Twelve months after treatment, 25 of 27 eyes (93%) achieved 20/40 or better uncorrected visual acuity and 19 eyes (70%) achieved 20/20. No patient lost two or more lines of Snellen visual acuity assessed 6 months and later after treatment. The mean spherical equivalent refraction was reduced from +2.90 at baseline to +0.10 D at 1 year and +0.40 D at 2 years; 65% of eyes had a refraction within +/- 0.50 D. Four patients had further treatment by laser in situ keratomileusis for undercorrection in three eyes and overcorrection in one eye. Pelli-Robson contrast acuity was significantly reduced 12 months after treatment from a mean 1.72 before to 1.66 after PRK (P = .02, t-test). CONCLUSIONS PRK for hyperopia using the VISX Star excimer laser system was effective in the treatment of hyperopic astigmatism. Although no patient lost two or more lines of high contrast best spectacle-corrected Snellen visual acuity 1 year after treatment, there was a significant decrease in Pelli-Robson contrast acuity.
Collapse
Affiliation(s)
- Julian D Stevens
- Moorfields Eye Hospital, 162 City Road, London, Great Britain EC1V 2PD.
| | | |
Collapse
|
27
|
Tabbara KF, El-Sheikh HF, Islam SM. Laser in situ Keratomileusis for the Correction of Hyperopia From +0.50 to +11.50 Diopters With the Keracor 117C Laser. J Refract Surg 2001; 17:123-8. [PMID: 11310761 DOI: 10.3928/1081-597x-20010301-05] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate excimer laser in situ keratomileusis (LASIK) for the correction of hyperopia. METHODS We reviewed retrospectively the medical records of 46 patients treated with LASIK for hyperopia. All patients had a complete ophthalmologic evaluation. The corneal bed was ablated using the Bausch & Lomb Chiron Keracor 117C excimer laser to create a paracentral annular ablation under a nasally hinged 160-microm corneal flap with the Chiron Automatic Corneal Shaper microkeratome. Follow-up was a minimum of 6 months. RESULTS Eighty eyes of 46 patients (23 males and 23 females) were included. Age ranged from 18 to 65 years (mean, 42 yr). The range of preoperative spherical equivalent refraction was +0.50 to +11.50 D (mean, +3.40 D). Mean postoperative spherical equivalent refraction at 6 months was +0.26 D. Six months after surgery, 35 eyes (44%) achieved uncorrected visual acuity of 20/20 or better and 78 eyes (97.5%) achieved 20/40 or better. Forty-six eyes (58%) had a postoperative spherical equivalent refraction within +/-0.50 D of attempted correction, and 67 eyes (84%) were within +/-1.00 D of attempted correction. When using the Bausch & Lomb Chiron Keracor 117C excimer laser to correct hyperopia, eyes with a spherical equivalent refraction less +2.00 D should be overcorrected by 25%, +2.00 to +4.00 D by 30%, and over +4.00 by 40%. The positive cylinder should be overcorrected by 10%. CONCLUSIONS LASIK was safe and effective in the treatment of hyperopia from +0.50 to +11.50 D. Regression following LASIK for hyperopia remains a problem. A special nomogram was required to achieve results comparable with those for myopia.
Collapse
Affiliation(s)
- K F Tabbara
- The Eye Center and The Eye Foundation for Research in Ophthalmology, Riyadh, Saudi Arabia.
| | | | | |
Collapse
|
28
|
Pop M, Payette Y, Amyot M. Clear lens extraction with intraocular lens followed by photorefractive keratectomy or laser in situ keratomileusis. Ophthalmology 2001; 108:104-11. [PMID: 11150273 DOI: 10.1016/s0161-6420(00)00451-6] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
OBJECTIVE To study photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK) after clear lens extraction (CLE) with intraocular lens (IOL) implantation for hyperopia or astigmatism. DESIGN Retrospective, noncomparative interventional case series. PARTICIPANTS Sixty-five eyes (55 subjects) had CLE with posterior chamber IOL implants for hyperopia up to 12.25 diopters (D); 31 eyes were retreated with PRK, and 34 eyes were retreated with LASIK for residual ametropias. INTERVENTION For PRK and LASIK, the refractive surgery was performed with the slit-scanning excimer laser Nidek EC-5000, Nidek Co., Tokyo, Japan. MAIN OUTCOME MEASURES Manifest refraction, best-spectacle and uncorrected Snellen visual acuity, haze, and halos were evaluated before surgery and at 1, 3, 6, and 12 months postoperative. RESULTS Forty-seven eyes were evaluated at the 12-month postoperative examination: 96% of these eyes had spherical equivalents (SE) within +/-2 D of emmetropia, 79% of eyes had SE within +/-1 D of emmetropia and 51% of eyes had SE within +/-0.50 D of emmetropia. Eighty-five percent of the eyes at 12 months postoperative had uncorrected visual acuity of 20/40 or better, and 46% of eyes had uncorrected visual acuity of 20/20 or better. Eighty-seven percent of the eyes at 12 months postoperative had uncorrected visual acuity within 1 Snellen line of their initial best spectacle-corrected visual acuity (BSCVA) before all treatment. No eye lost 2 Snellen lines of BSCVA at 3, 6, or 12 months after PRK or after LASIK. CONCLUSIONS IOL implantation for CLE, although an invasive technique, resulted in better refractive outcomes without laser-related clinical complications after PRK or LASIK adjustment.
Collapse
Affiliation(s)
- M Pop
- Michel Pop Clinics, Montreal and Hull, Canada
| | | | | |
Collapse
|
29
|
Haw WW, Manche EE. Prospective Study of Photorefractive Keratectomy for Hyperopia Using an Axicon Lens and Erodible Mask. J Refract Surg 2000; 16:724-30. [PMID: 11110313 DOI: 10.3928/1081-597x-20001101-08] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate prospectively the long-term safety, efficacy, and visual performance following photorefractive keratectomy (PRK) for hyperopia using an erodible mask and axicon lens system. METHODS Eighteen eyes of 9 patients with a mean preoperative spherical equivalent refraction of +2.26 +/- 0.82 D (range, +1.13 to +4.00 D) underwent PRK with the Summit Apex Plus excimer laser following manual scraping of the epithelium. Eyes were prospectively evaluated 1, 3, 6, 9, 12, 18, and 24 months following the procedure. Primary outcome variables included cycloplegic refraction and uncorrected visual acuity (UCVA). Visual performance was determined by contrast sensitivity measurements under scotopic (21 lux) and photopic (324 lux) conditions and best spectacle-corrected visual acuity (BSCVA) under scotopic, photopic, and glare conditions. RESULTS For 18 eyes, 98.2% of the mean preoperative spherical equivalent refraction was corrected to +0.04 +/- 0.87 D (range, -1.38 to +2.00 D) at 24 months after PRK. Twelve eyes (67%) were within +/-0.50 D of attempted correction and 15 eyes (83%) were within +/-1.00 D. Stability within +/-0.50 D was achieved after 6 months. Two eyes (11%) experienced almost complete regression of the refractive effect. There was no statistically significant decrease in contrast sensitivity under scotopic or photopic conditions. (P > .05). Best spectacle-corrected visual acuity showed progressive improvement in the early postoperative period. By 24 months, 0 eyes (0%) lost 2 or more lines of BSCVA under scotopic and photopic conditions and 1 eye (5.5%) lost 2 or more lines under glare conditions. Fourteen eyes (78%) had grade 1 to 3 anterior stromal haze at 24 months which was characteristically mid-peripheral and did not adversely affect visual performance. CONCLUSION Photorefractive keratectomy with the the Summit Apex Plus excimer laser for low to moderate hyperopia resulted in an effective reduction of hyperopia without compromising long-term visual performance. Stability and recovery of distance uncorrected and best spectacle-corrected visual acuity took approximately 6 months.
Collapse
Affiliation(s)
- W W Haw
- Stanford University School of Medicine, Department of Ophthalmology, CA 94305, USA
| | | |
Collapse
|
30
|
Zadok D, Maskaleris G, Montes M, Shah S, Garcia V, Chayet A. Hyperopic laser in situ keratomileusis with the Nidek EC-5000 excimer laser. Ophthalmology 2000; 107:1132-7. [PMID: 10857833 DOI: 10.1016/s0161-6420(00)00097-x] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVE To evaluate the efficacy, safety, and predictability of hyperopic laser in situ keratomileusis (H-LASIK) using modified software. DESIGN Retrospective, noncomparative case series. PARTICIPANTS The first 72 consecutive eyes of 44 patients with up to +5.00 diopters (D) hyperopia. INTERVENTION Hyperopic LASIK using the Automatic Corneal Shaper (ACS; Chiron Vision, Claremont, CA) and the Nidek EC-5000 excimer laser (Nidek, Tokyo, Japan). MAIN OUTCOME MEASURES Uncorrected visual acuity, manifest spherical equivalent (MSE), best-corrected visual acuity (BCVA), and complications were studied. RESULTS At 6 months, in the low hyperopia group (<3.00 D), mean MSE was +0.30 +/- 0.71 D, with 88.9% eyes within 1 D of emmetropia compared with +1.09 +/- 0.92 D and 51.8% within 1 D of emmetropia in the moderate hyperopia group (> or =3.00 D; P = 0.003). Uncorrected visual acuity was 20/40 or better in 43 of 45 eyes (95.6%) and in 21 of 27 (77.8%) eyes in the low and moderate hyperopia groups, respectively. Only one eye (1.4%) from the moderate hyperopia group lost two lines of BCVA. Eighteen eyes (25%) required retreatment to correct residual hyperopia, 9 eyes (20.0%) in the low hyperopia group and 9 eyes (33.3%) in the moderate hyperopia group. Retreatments resulted in an MSE of +0.02 +/- 0.45 D and +0.04 +/- 0.73 D in the low and moderate hyperopia groups, respectively. No flap-related complications were seen. CONCLUSIONS Hyperopic LASIK with the ACS and the Nidek EC-5000 excimer laser using our modified software is a safe, effective, and predictable procedure for low hyperopia. Results are satisfactory up to moderate hyperopia. Significant regression can occur for low and moderate hyperopia. Retreatment can be performed safely and effectively to improve the visual and refractive results.
Collapse
Affiliation(s)
- D Zadok
- Centro Oftalmologico de Tijuana, BC, Mexico.
| | | | | | | | | | | |
Collapse
|
31
|
O'Brart DP, Stephenson CG, Baldwin H, Ilari L, Marshall J. Hyperopic photorefractive keratectomy with the erodible mask and axicon system: two year follow-up. J Cataract Refract Surg 2000; 26:524-35. [PMID: 10771225 DOI: 10.1016/s0886-3350(00)00329-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate efficacy and long-term stability of hyperopic photorefractive keratectomy (H-PRK) using the erodible mask and Axicon system. SETTING Department of Ophthalmology, St. Thomas' Hospital, London, England. METHODS Forty-three patients (43 eyes), with a mean preoperative refraction (spherical equivalent) of +4.54 diopters (D) (range +1.75 to +7.50 D), were treated using an Apex Plus(R) excimer laser (Summit Technology). This uses an erodible mask to ablate a 6. 50 mm diameter hyperopic correction and an Axicon to fashion a 1.50 mm blend zone around the correction. The overall ablation diameter was 9.50 mm. Follow-up was 2 years. RESULTS At 2 years, the mean manifest refraction was +0.16 D (range +4.125 to -4.000 D), with the induced correction appearing stable after 9 months. Based on the Munnerlyn algorithm, predictability was acceptable for corrections up to +4.50 D, with 68% of eyes within +/-1.00 D of the predicted correction. It was poorer for +6.00 D corrections, with 33% of eyes within +/-1.00 D of that expected. Patient satisfaction was high. Forty eyes (93%) had an improvement in uncorrected near visual acuity and 37 (86%), an improvement in uncorrected distance acuity. A peripheral ring of haze, 6.5 mm in diameter, appeared in all eyes 1 month postoperatively. Its intensity was maximal at 3 to 9 months and then diminished over time. There were no significant differences in measurements of the central corneal transparency at 12 and 24 months and those preoperatively. Measurements of flicker contrast sensitivity, forward light scatter (glare), and scotopic halos showed no significant differences between preoperative values and those measured after 6 months. CONCLUSIONS Achieved H-PRK corrections with the erodible mask and Axicon system agreed closely with the Munnerlyn algorithm, with refractive stability after 9 months. Predictability was acceptable for corrections up to +4.50 D. Axial corneal transparency was not compromised and visual performance, in terms of best spectacle-corrected visual acuity, forward light scatter, and night halos, was not impaired.
Collapse
Affiliation(s)
- D P O'Brart
- Department of Ophthalmology, United Medical and Dental Schools, St. Thomas' Hospital, London, England, UK
| | | | | | | | | |
Collapse
|
32
|
Reviglio VE, Luna JD, Rodríguez ML, García FE, Juárez CP. Laser in situ keratomileus using the LaserSight 200 laser: results of 950 consecutive cases. J Cataract Refract Surg 1999; 25:1062-8. [PMID: 10445191 DOI: 10.1016/s0886-3350(99)00121-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To examine the refractive outcome in 950 consecutive eyes having laser in situ keratomileusis (LASIK) by 1 surgeon with experience in keratomileusis. SETTING Outpatient excimer laser surgical facility. METHODS This study comprised 950 consecutive eyes of 475 patients having LASIK as a primary procedure with a LaserSight 200 excimer laser (8.51 software). A nasal hinged flap and a Chiron microkeratome were used. Preoperative cycloplegic refraction was done only in patients younger than 25 years and in all hyperopic cases. Subjective preoperative and postoperative manifest refractions were done after autorefractometry in all cases. In cases of hyperopia, the software was modified by adding 30% to the refractive error. Enhancement results are not included. RESULTS Of the 950 eyes, 893 (94.00%) were myopic and 57 (6.00%), hyperopic. In the low myopia group (1.00 to 3.99 D) of 223 eyes (24.97%), mean spherical equivalents (SEs) were -2.90 D +/- 0.56 (SD) preoperatively, -0.46 +/- 0.6 D 3 months postoperatively, and -0.41 +/- 0.5 D 6 months postoperatively. In the moderate myopia group (4.00 to 5.99 D) of 205 eyes (22.96%), respective mean SEs were -4.90 +/- 0.7 D, -0.90 D +/- 0.9 D, and -0.67 +/- 0.7 D. In the high myopia group (6.00 to 9.99) of 266 eyes (25.30%), the respective means were -7.70 +/- 1.3 D, -0.76 +/- 0.99 D, and -0.60 +/- 0.8 D. In the extreme myopia group (10.21 to 30.00) of 199 eyes (22.28%), the respective means were -13.30 +/- 2.9 D, -1.30 +/- 1.4 D, and -1.13 +/- 1.3 D. For the entire myopic group, the mean astigmatism was +1.55 +/- 1.38 D, +1.09 +/- 0.92 D, and +0.87 +/- 0.77 D, respectively. The low hyperopia group (1.00 to 2.99 D) of 39 eyes (68.42%) had a mean preoperative SE of +1.80 +/- 0.59 D and mean postoperative SEs of +1.00 +/- 0.76 D at 3 months and +1.16 +/- 0.52 D at 6 months. The respective means in the moderate hyperopia group (3.00 to 6.00) of 18 eyes (31.57%) were +4.62 +/- 1.19 D, +3.71 +/- 1.12 D, and +4.00 +/- 1.07 D. CONCLUSIONS Laser in situ keratomileus for myopia using the LaserSight 200 excimer laser was stable with time and safe for the correction of different degrees of myopia. In the hyperopic group, marked regression occurred in a large percentage of patients. Thus, we will not perform LASIK for hyperopia until the software improves.
Collapse
|
33
|
Abstract
The development of excimer laser technology, coupled with advances in lamellar corneal surgery, has heralded a new era in the treatment of refractive errors. This paper discusses the current status of hyperopic laser-assisted in situ keratomileusis. This surgical modality is at a relatively early stage of investigation but appears to offer promise for the surgical correction of hyperopia. This paper considers the evolution of the technique, analyzes the current literature, and discusses the current indications, limitations, and possible future developments.
Collapse
Affiliation(s)
- D P O'Brart
- Department of Ophthalmology, St. Thomas' Hospital, London, UK
| |
Collapse
|
34
|
Carones F, Brancato R, Morico A, Vigo L, Venturi E, Gobbi PG. Photorefractive Keratectomy for Hyperopia Using an Erodible Disc and Axicon Lens: 2-Year Results. J Refract Surg 1998; 14:504-11. [PMID: 9791816 DOI: 10.3928/1081-597x-19980901-07] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND This paper presents the results over a 2-year follow-up of the first human trial of photorefractive keratectomy (PRK) for correction of hyperopia using an erodible disc excimer laser delivery system (Summit) coupled to an axicon lens. METHODS We treated 25 eyes of 21 patients for a mean correction of +3.38 +/- 0.97 D (range, +1.00 to +4.00 D). The hyperopic correction was made using an erodible disc inserted on the laser optical pathway; an axicon lens was then used to create a blend transition zone. Eyes were evaluated at 1, 3, 6, and 12 months after surgery. For a smaller series of 11 eyes, we also present 24-month results. RESULTS Mean refractive error 1 month after treatment (25 eyes) was -2.35 +/- 1.55 D (range, +1.00 to -6.50 D). Eight eyes (32%) had a spectacle-corrected visual acuity loss greater than 1 line. Twelve months after treatment, mean spherical equivalent refraction was -0.47 +/- 0.80 D (range, +1.25 to -2.25 D). Nineteen eyes showed an improvement (range, 3 to 8 lines) in uncorrected distance visual acuity and 23 showed improvement in uncorrected vision at reading distance (1 to 7 lines). CONCLUSION This technique proved effective in reducing hyperopia, but predictability must be demonstrated in a larger treatment group. Safety was confirmed by the absence of delayed reepithelialization and the absence of spectacle-corrected visual acuity loss greater than 1 line at 1 year after surgery.
Collapse
Affiliation(s)
- F Carones
- Department of Ophthalmology and Visual Sciences, Scientific Institute San Raffaele Hospital, University of Milan, Italy
| | | | | | | | | | | |
Collapse
|