Comparison of the Predictive Accuracy of Intraocular Lens Power Calculations after Phototherapeutic Keratectomy in Granular Corneal Dystrophy Type 2. J Clin Med 2023; 12:jcm12020584. [PMID: 36675513 PMCID: PMC9861484 DOI: 10.3390/jcm12020584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 01/05/2023] [Accepted: 01/07/2023] [Indexed: 01/12/2023] Open
Abstract
Granular corneal dystrophy type 2 (GCD2) is an autosomal dominant disease affecting vision. Phototherapeutic keratectomy (PTK) is advantageous in removing vision-threatening corneal opacities and postponing keratoplasty; however, it potentially disturbs accurate intraocular lens (IOL) power calculation in cataract surgery. The myopic/hyperopic Haigis-L method with or without the central island has been reported; nevertheless, an optimal method has not yet been established. To compare the predictive accuracy of post-PTK IOL power calculations in GCD2, the retrospective data of 30 eyes from July 2017 to December 2020 were analyzed. All GCD2-affected eyes underwent post-PTK standard cataract surgery using the WaveLight EX500 platform (Alcon Laboratories, Inc., Fort Worth, TX, USA) under a single surgeon. The mean prediction error (MPE) and absolute error (MAE) with the myopic/hyperopic Haigis-L, Barrett Universal II, Barrett True-K, Haigis, and SRK/T by standard keratometry (K) and total keratometry (TK), where possible, were analyzed. Barrett Universal II and SRK/T showed significantly superior MPE, and MAE compared with the myopic/hyperopic Haigis-L method. TK was not significantly superior to K in the same formula. In conclusion, this study suggests that these biometries and formulas, especially Barrett Universal II and SRK/T, are potentially useful in IOL power calculation in GCD2 after PTK.
Collapse
|
2
|
Charpentier S, Keilani C, Maréchal M, Friang C, De Faria A, Froussart-Maille F, Delbarre M. Corneal haze post photorefractive keratectomy. J Fr Ophtalmol 2021; 44:1425-1438. [PMID: 34538661 DOI: 10.1016/j.jfo.2021.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 04/21/2021] [Accepted: 05/18/2021] [Indexed: 10/20/2022]
Abstract
Corneal haze represents subepithelial corneal fibrosis, a manifestation of a pathological healing process. It occurs as a result of an epithelial-stromal lesion involving a break in the epithelial barrier. It is an inflammatory response that involves the migration, multiplication and differentiation of keratocytes into mature myofibroblasts, causing loss of corneal transparency. Although it is a transient phenomenon, this complication is feared following refractive photokeratectomy (PRK), because it can cause alterations in the quality of vision, refractive regression and decreased visual acuity. The severity of these symptoms is correlated with the severity of the corneal haze, which can be assessed clinically or by objective means such as corneal densitometry measurement. The frequency and severity of corneal haze increase with the depth of photoablation in PRK and are therefore increased during the treatment of severe ametropia. Considering that no consensus exists, the application of mitomycin C (MMC) intraoperatively and topical corticosteroids postoperatively are conventionally used to inhibit collagen synthesis, sometimes in combination with various protocols depending on the center or surgeon. This review of the literature reports the current knowledge on corneal haze, in order to better understand it and optimise its prevention in the context of a decreased MMC supply, which has occurred in the past and could recur in the future.
Collapse
Affiliation(s)
- S Charpentier
- Service d'ophtalmologie, hôpital d'instruction des armées Bégin, 69, avenue de Paris, 94163 Saint-Mandé Cedex, France.
| | - C Keilani
- Service ophtalmologie, hôpital d'instruction des armées Percy, BP 406, 92141 Clamart Cedex, France
| | - M Maréchal
- Service ophtalmologie, hôpital d'instruction des armées Percy, BP 406, 92141 Clamart Cedex, France; Centre principal d'expertise du personnel naviguant, BP 406, 92141 Clamart Cedex, France
| | - C Friang
- Service ophtalmologie, hôpital d'instruction des armées Percy, BP 406, 92141 Clamart Cedex, France; Centre principal d'expertise du personnel naviguant, BP 406, 92141 Clamart Cedex, France
| | - A De Faria
- Service ophtalmologie, hôpital d'instruction des armées Percy, BP 406, 92141 Clamart Cedex, France; Centre principal d'expertise du personnel naviguant, BP 406, 92141 Clamart Cedex, France
| | - F Froussart-Maille
- Service ophtalmologie, hôpital d'instruction des armées Percy, BP 406, 92141 Clamart Cedex, France; Centre principal d'expertise du personnel naviguant, BP 406, 92141 Clamart Cedex, France; École du Val-de-Grâce, 1, place Alphonse Laveran, 75230 Paris Cedex 05, France
| | - M Delbarre
- Service ophtalmologie, hôpital d'instruction des armées Percy, BP 406, 92141 Clamart Cedex, France; Centre principal d'expertise du personnel naviguant, BP 406, 92141 Clamart Cedex, France
| |
Collapse
|
3
|
One-Year Visual and Refractive Outcomes following LASIK for Myopia and Myopic Astigmatism with MEL 90 versus Schwind Amaris 750S Excimer Laser: A Comparative Study. J Ophthalmol 2021; 2021:9929181. [PMID: 34258051 PMCID: PMC8257363 DOI: 10.1155/2021/9929181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Accepted: 06/19/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose To compare clinical outcomes following LASIK for myopia performed with MEL 90 vs. Schwind Amaris 750S excimer laser. Methods Data were collected retrospectively for patients who underwent Femto-LASIK, using the MEL 90 and Schwind Amaris 750S excimer laser for correction of myopia and myopic astigmatism within the range of -1.00 to -10.00 D SE from January 2013 till June 2018. Outcomes were analysed at 12 months for safety, efficacy, enhancement rate, and long-term complications. Results A total of 328 eyes of 328 patients were analysed. One hundred and sixty-three eyes were treated with Schwind Amaris and the remaining 165 eyes with the MEL 90 laser. Twelve months postoperatively, the mean UDVA, CDVA, residual SE, and cylinder in the Amaris group were -0.10 ± 0.09 logMAR, -0.14 ± 0.06 logMAR, -0.21 ± 0.22 D, -0.13 ± 0.18 D versus -0.05 ± 0.07 logMAR, -0.09 ± 0.08 logMAR, -0.23 ± 0.23 D, and -0.14 ± 0.21 D for the MEL 90 group (p values >0.05). For the Amaris group, safety and efficacy indices were 1.12 and 1.02, whereas for the MEL 90 group, these indices were 1.08 and 1.00, respectively. No eye in either group had any postop flap-related complications, infectious keratitis, diffuse lamellar keratitis, or keratectasia. Two eyes in the Amaris and 4 eyes in MEL 90 group required enhancement for the progression of myopia. Conclusion At 12 months, both Schwind Amaris 750S and MEL 90 lasers demonstrated comparable clinical outcomes for myopic LASIK in a single surgeon setting.
Collapse
|
4
|
Myopic outcomes after excimer laser phototherapeutic keratectomy (PTK). J Fr Ophtalmol 2020; 44:35-40. [PMID: 33158609 DOI: 10.1016/j.jfo.2020.03.024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 03/24/2020] [Accepted: 03/25/2020] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate refractive outcomes following excimer laser phototherapeutic keratectomy (PTK). METHODS A retrospective non-randomized review of refractive outcomes of 146 consecutive eyes treated with excimer laser PTK at the Rothschild Foundation, Paris, France. Inclusion criteria were all patients undergoing PTK laser using a flying spot excimer laser system (Wavelight Allegretto, Alcon Surgical, Inc.) from October 2016 to June 2018. Exclusion criteria were incomplete data, irregular astigmatism and dystrophies of uncertain diagnosis. Preoperative diagnoses included recurrent corneal erosion syndrome without dystrophy and Cogan corneal dystrophies. The primary outcome measure was the change in spherical equivalent (SEQ) at M1 post PTK. The secondary outcome measure was the creation of a regression equation for predicting refractive outcomes after PTK, by analyzing the effect of ablation depth (AD) and optical zone (OZ) diameter. RESULTS Fifty-eight eyes of 54 patients were included. The mean OZ was 7.352 mm±0.622. The mean AD was 18.362μm±21.406. At M1 postoperatively, the mean SEQ was -2.485 D±2.628 and mean final SEQ was -1.052 D±1.260. Both OZ and AD were independent variables with significant effects on the final visual outcome. A regression equation for predicting refractive outcomes was established. No complications were observed. CONCLUSION The Wavelight flying spot excimer laser system produces myopic outcomes following PTK. Both OZ and AD are significant variables. A regression equation was created and may aid in prediction of refractive outcomes following PTK.
Collapse
|
5
|
Mehlan J, Linke SJ, Skevas C, Steinberg J, Giannakakis K, Katz T. Safety and complications after three different surface ablation techniques with mitomycin C: a retrospective analysis of 2757 eyes. Graefes Arch Clin Exp Ophthalmol 2018; 257:217-223. [PMID: 30076471 DOI: 10.1007/s00417-018-4077-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2018] [Revised: 07/18/2018] [Accepted: 07/23/2018] [Indexed: 10/28/2022] Open
Abstract
BACKGROUND To evaluate the safety and spectrum of complications of three excimer laser surface ablation techniques (SATs) with an intraoperative application of mitomycin C (MMC) 0.02%. A retrospective, non-comparative large case series. METHODS SATs were performed on 2757 eyes with a preoperative spherical equivalent (SE) of - 4.41 ± 2.44 and a Wavelight Allegretto 200 platform. Ablation zone diameters between 6.0 and 7.0 mm were used according to mesopic pupil size. All patients were treated with an intraoperative application of MMC for 30 to 90 s depending on refractive error. The mean follow-up time was > 3 months (107 ± 24 days). Complication range and incidence were analyzed retrospectively and safety index was calculated. RESULTS Two thousand seven hundred and fifty-seven eyes met the inclusion criteria for surface ablation. Two thousand five hundred and seventy-three eyes were assigned to alcohol-assisted photorefractive keratectomy (APRK), 135 eyes to transepithelial photorefractive keratectomy (TPRK), and 49 eyes to off-flap epithelial laser in situ keratomileusis (EpiLASIK/EpiK). Overall, the safety index was 1.06 ± 0.28. Haze was graded according to the Fantes scale. Haze incidence rates were highest in the TPRK group (14.81%) and comparably low in APRK (2.95%) and EpiK (4.08%) groups. CONCLUSIONS Intraoperative topical application of MMC (0.02%) results in good safety and no severe side effects. However, highest incidence of haze was observed after TPRK. The more frequent peripheral localization of haze might be attributed to large ablation zones and the wavefront optimized ablation profile especially in the PTK modus of the laser platform.
Collapse
Affiliation(s)
- Juliane Mehlan
- Department of Ophthalmology, UKE - University Clinic Hamburg-Eppendorf, 52 Martinistrasse, 20246, Hamburg, Germany.
| | - Stephan Johannes Linke
- Department of Ophthalmology, UKE - University Clinic Hamburg-Eppendorf, 52 Martinistrasse, 20246, Hamburg, Germany.,Care-Vision Germany, 52 Martinistrasse, 20246, Hamburg, Germany.,zentrumsehstärke, 64 Martinistrasse, 20246, Hamburg, Germany
| | - Christos Skevas
- Department of Ophthalmology, UKE - University Clinic Hamburg-Eppendorf, 52 Martinistrasse, 20246, Hamburg, Germany
| | - Johannes Steinberg
- Care-Vision Germany, 52 Martinistrasse, 20246, Hamburg, Germany.,zentrumsehstärke, 64 Martinistrasse, 20246, Hamburg, Germany
| | - Konstantinos Giannakakis
- Augenarztpraxis Dr. med. Wilhelm Kröncke & Albrecht Zwick, 7 Grashoffstrasse, 27570, Bremerhaven, Germany
| | - Toam Katz
- Department of Ophthalmology, UKE - University Clinic Hamburg-Eppendorf, 52 Martinistrasse, 20246, Hamburg, Germany.,Care-Vision Germany, 52 Martinistrasse, 20246, Hamburg, Germany
| |
Collapse
|
6
|
Spadea L, Giammaria D, Trabucco P. Corneal wound healing after laser vision correction. Br J Ophthalmol 2015; 100:28-33. [PMID: 26405102 DOI: 10.1136/bjophthalmol-2015-306770] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2015] [Accepted: 09/07/2015] [Indexed: 11/04/2022]
Abstract
Any trauma can trigger a cascade of responses in tissues, with the purpose of safeguarding the integrity of the organ affected by the trauma and of preventing possible damage to nearby organs. Subsequently, the body tries to restore the function of the organ affected. The introduction of the excimer laser for keratorefractive surgery has changed the treatment landscape for correcting refractive errors, such as myopia, hyperopia, and astigmatism. In recent years, with the increased understanding of the basic science of refractive errors, higher-order aberrations, biomechanics, and the biology of corneal wound healing, a reduction in the surgical complications of keratorefractive surgery has been achieved. The understanding of the cascade of events involved in the corneal wound healing process and the examination of how corneal wound healing influences corneal biomechanics and optics are crucial to improving the efficacy and safety of laser vision correction.
Collapse
Affiliation(s)
- Leopoldo Spadea
- Department of Biotechnology and Medical-Surgical Sciences, 'Sapienza' University of Rome, Latina, Italy
| | - Daniele Giammaria
- Department of Ophthalmology, Ospedali Riuniti Marche Nord, Fano-Pesaro, Italy
| | - Paolo Trabucco
- Department of Biotechnology and Medical-Surgical Sciences, 'Sapienza' University of Rome, Latina, Italy
| |
Collapse
|
7
|
Reinstein DZ, Carp GI, Lewis TA, Archer TJ, Gobbe M. Outcomes for Myopic LASIK With the MEL 90 excimer laser. J Refract Surg 2015; 31:316-21. [PMID: 25974970 DOI: 10.3928/1081597x-20150423-05] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Accepted: 03/16/2015] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the visual outcomes of myopic LASIK performed with the MEL 90 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) using the Triple-A profile with a 500-Hz pulse rate. METHODS Retrospective analysis of the first 286 myopic LASIK procedures (147 patients) by two experienced surgeons in which the VisuMax femtosecond laser and MEL 90 excimer laser (Carl Zeiss Meditec) were used following a standardized surgical technique. Inclusion criteria were preoperative spherical equivalent refraction (SEQ) up to -10.38 diopters (D), cylinder up to 5.00 D, and corrected distance visual acuity (CDVA) of 20/25 or better. No nomogram adjustments were made. Patients were observed for 3 months. Flap thickness was between 80 and 110 µm and optical zone was between 6 and 7 mm. Standard outcomes analysis was performed. RESULTS Preoperatively, mean SEQ was -3.83 ± 1.83 D (range: -0.13 to -10.38 D) and mean cylinder was -0.94 ± 0.86 D (range: 0.00 to -5.00 D). Mean age was 36.4 years (range: 18.2 to 74.1 years) with 50% female patients. Of this population, 138 eyes were treated by one surgeon and 148 eyes by another. The mean predictability of SEQ was -0.13 ± 0.34 D (range: -1.00 to +1.00 D). Postoperative SEQ was ± 0.50 D in 88% and ± 1.00 D in 100% of eyes. Preoperative CDVA was 20/20 or better in 97% of eyes. Postoperative uncorrected distance visual acuity was 20/20 or better in 92% and 20/25 or better in 99% of eyes. One line of CDVA was lost in 6% of eyes and no eyes lost two or more lines. There was statistically significant improvement in mesopic contrast sensitivity (CSV-1000) at 3 (P = .021), 6, 12, and 18 (all P ≤.001) cycles per degree. CONCLUSIONS The MEL 90 excimer laser using the Triple-A ablation profile with a 500-Hz pulse rate was found to achieve a small but real increase in contrast sensitivity and high efficacy for myopia up to -10.00 D and cylinder up to 5.00 D without the need for a nomogram adjustment.
Collapse
|
8
|
Shalchi Z, O’Brart DP, McDonald RJ, Patel P, Archer TJ, Marshall J. Eighteen-year follow-up of excimer laser photorefractive keratectomy. J Cataract Refract Surg 2015; 41:23-32. [DOI: 10.1016/j.jcrs.2014.05.034] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2013] [Revised: 04/20/2014] [Accepted: 05/03/2014] [Indexed: 10/24/2022]
|
9
|
Effect of mitomycin-C on the variance in refractive outcomes after photorefractive keratectomy. J Cataract Refract Surg 2014; 40:1980-4. [DOI: 10.1016/j.jcrs.2014.02.048] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2013] [Revised: 02/20/2014] [Accepted: 02/22/2014] [Indexed: 11/23/2022]
|
10
|
Twenty-year follow-up of a randomized prospective clinical trial of excimer laser photorefractive keratectomy. Am J Ophthalmol 2014; 158:651-663.e1. [PMID: 24973609 DOI: 10.1016/j.ajo.2014.06.013] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2013] [Revised: 06/15/2014] [Accepted: 06/17/2014] [Indexed: 11/23/2022]
Abstract
PURPOSE To investigate the 20-year efficacy and safety of photorefractive keratectomy (PRK). DESIGN Long-term observational case series. METHODS In the setting of a university hospital, a study population of 42 patients (42 eyes) who had, as part of a randomized prospective trial, undergone PRK 20 years previously were studied. All had received -3.0 or -6.0 diopter (D) corrections with either 5.0 or 6.0 mm optical zones or a multizone treatment. The mean preoperative spherical equivalent refractive error (SEQ) was -5.13 D (range, -2.75 to -8.0 D). The outcome measures included visual acuity, refractive error, corneal topography and axial length. RESULTS Between 1 and 20 years there was an increase in mean myopic SEQ of -0.54 D (P < 0.02). In patients younger than 40 years of age at time of correction, this increase was -0.92 D (P < 0.002) with an accompanying increase in variance (P < 0.02), whereas in those older than 40 it was -0.08D (P = 0.8). In female patients the change was -0.69D (P < 0.01), while in males it was -0.26D (P = 0.6). The efficacy index at 20 years was 0.49, and the safety index was 0.97. Corrected distance visual acuity improved between 1 and 20 years (P < 0.01); 93% of corneas were clear at 20 years; 3 eyes had trace haze. There was an improvement in haze scores between 1 and 20 years (P < 0.02). Cornea power remained unchanged between 6 months and 20 years (P = 0.4). Axial length increased by a mean of 0.84 mm (P < 0.0001). There was no ectasia. CONCLUSIONS There was a slight but significant increase in myopic SEQ after PRK between 1 and 20 years, particularly in those under 40 at the time of treatment and in female patients. Corneal power remained unchanged, but axial length increased. The procedure was safe, with no long-term sight-threatening complications and with improvements in corrected distance visual acuity and corneal transparency with time.
Collapse
|
11
|
Vestergaard AH. Past and present of corneal refractive surgery: a retrospective study of long-term results after photorefractive keratectomy and a prospective study of refractive lenticule extraction. Acta Ophthalmol 2014; 92 Thesis 2:1-21. [PMID: 24636364 DOI: 10.1111/aos.12385] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
UNLABELLED Surgical correction of refractive errors is becoming increasingly popular. In the 1990s, the excimer laser revolutionized the field of corneal refractive surgery with PRK and LASIK, and lately refractive lenticule extraction (ReLEx) of intracorneal tissue, using only a femtosecond laser, has become possible. Two new procedures were developed, ReLEx flex (FLEX) and ReLEx smile (SMILE). Until this thesis, only a few long-term studies of PRK with a relatively limited number of patients had been published; therefore, this thesis intended to retrospectively evaluate long-term outcomes after PRK for all degrees of myopia for a large number of patients. Furthermore, a prospective contralateral eye study comparing FLEX and SMILE, when treating high to moderate degrees of myopia, had not been performed prior to this study. This was the second aim of this thesis. In the first study, results from 160 PRK patients (289 eyes) were presented. Preoperative spherical equivalent ranged from -1.25 to -20.25 D, with 78% having low myopia (<-6 D). Average follow-up time was 16 years (range 13-19 years), making this the longest published follow-up study on PRK patients. Outcomes from eyes with low myopia were generally superior to outcomes from eyes with high myopia, at final follow-up. Seventy-two percent were within ± 1.00 D of target refraction, as compared to 47% of eyes with high myopia. However, results from a subgroup of unilateral treated PRK patients indicated that refraction at final follow-up was affected by myopic progression. Fifty percent of eyes with low myopia had uncorrected 20/20 distance visual acuity or better, as compared to 22% of eyes with high myopia. Haze did not occur if attempted corrections were <-4 D, and only eyes with high myopia lost two lines or more of CDVA (corrected distance visual acuity). Eighty-one per cent were satisfied or very satisfied with their surgery. CONCLUSION The results support the continued use of the excimer laser for corneal surface ablation as a treatment option for correction of low degrees of myopia, and as the treatment of choice for subgroups of refractive patients (thin corneas, etc.). The results also highlight that treatment of higher degrees of myopia with standard PRK should only be done today under special circumstances, due to low refractive predictability, and high risk of corneal haze. Technological advances since then should be taken into account when comparing these results with contemporary techniques. In the second study, 35 patients were randomized to receive FLEX in one eye and SMILE in the other. Preoperative spherical equivalent refraction ranged from -6 to -10 D with low degrees of astigmatism. A total of 34 patients completed the 6 month follow-up period. Refractive and visual outcomes were very similar for the two methods, as well as tear film measurements and changes in corneal biomechanics. Ninety-seven percent were within ± 1.00 D of target refraction, no eyes lost two lines or more of CDVA, and contrast sensitivity was unaffected after both procedures. The changes in higher-order aberrations were also very similar. There were also no differences in tear film parameters 6 months after surgery, although less postoperative foreign body sensation was reported within the first week after surgery in SMILE eyes. Corneal sublayer pachymetry measurements demonstrated equally increased epithelial thickness 6 months after surgery. Contrary to expectations, it was not possible to measure the theoretical biomechanical advantages of a small corneal incision in SMILE as compared to a corneal flap in FLEX. The main differences between FLEX and SMILE were found when the corneal nerves and intraoperative complications were evaluated. Thus, corneal sensitivity was better preserved and corneal nerve morphology was less affected after SMILE, but intraoperative complications occurred more frequently, although without visual sequela. Finally, 97% were satisfied or very satisfied with both their surgeries. CONCLUSION The results support the continued use of both FLEX and SMILE for treatment of up to high degrees of myopia. Overall, refractive and visual results for both procedures were good and similar, but from a biological point of view, the less invasive SMILE technique is more attractive, as demonstrated in this study, despite being slightly more surgically demanding than FLEX.
Collapse
Affiliation(s)
- Anders Højslet Vestergaard
- Faculty of Health Science; University of Southern Denmark; Odense Denmark
- Department of Ophthalmology; Odense University Hospital; Odense Denmark
| |
Collapse
|
12
|
Miraftab M, Seyedian MA, Hashemi H. Wavefront-Guided vs Wavefront-Optimized LASIK: A Randomized Clinical Trial Comparing Contralateral Eyes. J Refract Surg 2011; 27:245-50. [DOI: 10.3928/1081597x-20100812-02] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2009] [Accepted: 07/06/2010] [Indexed: 11/20/2022]
|
13
|
Vasaiwala R, Jackson WB, Azar DT, Al-Muammar A. Excimer Laser Surface Treatment. Cornea 2011. [DOI: 10.1016/b978-0-323-06387-6.00168-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
14
|
|
15
|
Effect of 3 excimer laser ablation frequencies (200 Hz, 500 Hz, 1000 Hz) on the cornea using a 1000 Hz scanning-spot excimer laser. J Cataract Refract Surg 2010; 36:1385-91. [PMID: 20656164 DOI: 10.1016/j.jcrs.2010.01.033] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2009] [Revised: 12/22/2009] [Accepted: 01/31/2010] [Indexed: 11/21/2022]
|
16
|
Ghoreishi SM, Naderibeni A, Peyman A, Rismanchian A, Eslami F. Aspheric profile versus wavefront-guided ablation photorefractive keratectomy for the correction of myopia using the Allegretto Eye Q. Eur J Ophthalmol 2009; 19:544-53. [PMID: 19551667 DOI: 10.1177/112067210901900405] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To compare the results of photorefractive keratectomy (PRK) with Q-factor customized aspheric ablation and wavefront-guided customized ablation for correction of myopia compound with astigmatism. METHODS Fifty-six patients were enrolled in this prospective controlled study. In each patient, one eye was randomly assigned for treatment with the Q-factor customized PRK (custom-Q study group) and the other eye treated with wavefront-guided customized PRK. Preoperative and 3-month postoperative manifest refraction, contrast sensitivity, visual acuity, aberrometry, and asphericity of the cornea were compared between the two groups. All eyes were treated with the Wavelight Eye-Q 400 Hz excimer laser in a single refractive surgery center by a single surgeon. RESULTS Uncorrected visual acuity (UCVA) improved to 20/20 or more and 20/25 or more in 34 eyes (60.7%) and 56 eyes (100%), respectively, in the wavefront-guided ablation group and in 36 eyes (64.2%) and 54 eyes (96.4%) in the custom-Q ablation group. All eyes had UCVA of 20/40 or better. A total of 54 eyes (96.4%) in the wavefront-guided ablation group and 56 (100%) in the custom-Q ablation group had spherical equivalent (SE) within -/+0.5 D. One eye in each group (2%) lost >or=2 lines of best-corrected visual acuity (BCVA). High order root mean square (RMS) in the wavefront-guided group was 0.3630-/+0.13 mum preoperatively and 0.427-/+0.17 at 3 months (p=0.2). In the custom-Q ablation group it was 0.329-/+0.092 preoperatively and 0.4730-/+0.181 at 3 months after PRK (p=0.08). CONCLUSIONS Regarding safety and refractive efficacy, custom-Q ablation profiles were clinically equivalent to wavefront-guided profiles in corrections of myopia up to -6.00 D and astigmatism up to 2.50 D.
Collapse
|
17
|
Sierra Wilkinson P, Davis EA, Hardten DR. LASIK. Ophthalmology 2009. [DOI: 10.1016/b978-0-323-04332-8.00019-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
18
|
Zadok D, Barkana Y, Levy Y, Avizemer H. Rehabilitation time after simultaneous bilateral photorefractive keratectomy for low to moderate myopia. J Cataract Refract Surg 2006; 32:117-20. [PMID: 16516789 DOI: 10.1016/j.jcrs.2005.11.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2005] [Accepted: 02/05/2005] [Indexed: 10/24/2022]
Abstract
PURPOSE To evaluate the visual acuity rehabilitation time after simultaneous bilateral photorefractive keratectomy (PRK) using a flying small spot laser. SETTING Eye Tech Medical Laser, Tel Aviv, Israel. METHODS In this prospective interventional nonrandomized clinical trial, 42 consecutive eyes (21 patients) with myopia ranging from -0.75 to -5.50 diopters (D) (mean -2.75 D +/- 1.18 [SD]) and astigmatism up to -2.75 D (mean -0.64 +/- 0.55 D) were treated with bilateral simultaneous PRK using the ESIRIS excimer laser (Schwind). Main outcome measures were uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), and manifest refraction up to 12 weeks after surgery. Both eyes of each patient were examined at the same follow-up after initial treatment. RESULTS Within 2 weeks and 1 month of the laser procedure, the UCVA was at least 20/40 in 1 eye in 85.7% of patients (18 patients) and 100% of patients (21 patients), respectively. After 2 weeks, UCVA was at least 20/20, 20/25, and 20/40 in 7.1%, 40.5%, and 80.9% of eyes. The final mean manifest spherical equivalent 12 weeks post laser treatment was -0.10 +/- 0.26 D, with a mean sphere of +0.02 +/- 0.22 D and a mean cylinder of -0.24 +/- 0.37 D. No eye had a BCVA loss during the follow-up. CONCLUSION Simultaneous bilateral PRK using a flying small spot excimer laser for low to moderate myopia allowed most patients to return to most daily tasks in a couple of weeks without compromising safety.
Collapse
Affiliation(s)
- David Zadok
- From the Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, affiliated to the Tel Aviv University, Israel.
| | | | | | | |
Collapse
|
19
|
Caster AI, Hoff JL, Ruiz R. Conventional vs Wavefront-guided LASIK Using the LADARVision4000 Excimer Laser. J Refract Surg 2005; 21:S786-91. [PMID: 16329381 DOI: 10.3928/1081-597x-20051101-28] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare outcomes after LASIK surgery using the conventional LADARVision4000 laser and the wavefront-guided LADARWave CustomCornea wavefront system. METHODS A prospective study was performed involving 140 myopic eyes receiving conventional or CustomCornea LASIK between May and October 2003. The preoperative manifest spherical equivalent refraction was limited to myopia < or = -7.00 diopters (D). The preoperative manifest cylinder was limited to < or = -2.50 D of astigmatism. Patients were evaluated for 3 months following surgery. Results evaluated were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, manifest refraction, dilated wavefront measurements, contrast sensitivity, and patient responses to subjective questionnaires. RESULTS For the CustomCornea eyes at 3 months, 80% (70/87) had UCVA > or = 20/20 and 95% (83/87) had UCVA > or = 20/25. For the conventional eyes at 3 months, 45% (9/20) had UCVA > or = 20/20 and 80% (16/20) had UCVA > or = 20/25. At the 3-month postoperative visit, 85% (74/87) of the CustomCornea eyes and 55% (11/20) of the conventional eyes were within +/- 0.50 D of their intended correction. At 1 and 3 months, the CustomCornea treated eyes had a statistically significant lower mean increase in higher order aberrations than conventionally treated eyes (P < .05). CONCLUSIONS CustomCornea wavefront-guided LASIK surgery appears safe and effective and provides clinical benefits that appear to exceed those of conventional LADARVision surgery.
Collapse
|
20
|
Gailitis RP. Comparison of LASIK Outcomes With the Alcon LADARVision4000 and the VISX STAR S2 Excimer Lasers Using Optimized Nomograms. J Refract Surg 2005; 21:683-90. [PMID: 16329359 DOI: 10.3928/1081-597x-20051101-05] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the difference in clinical outcomes between LASIK patients treated with the Alcon LADARVision4000 laser and the VISX STAR S2 laser using optimized nomograms. METHODS Data from 572 LASIK surgeries of two groups that were sequentially performed by one surgeon were retrospectively reviewed. The first group of 286 eyes were the last cases performed with the VISX STAR S2 laser. Following these surgeries, a second group of 286 eyes were the first cases performed with the Alcon LADARVision4000 laser, after an initial 50-eye adaptation period. Treatments were guided by the Refractive Surgery Consultant software. RESULTS For myopic eyes 3 months postoperatively, the percentage of eyes with uncorrected visual acuity (UCVA) > or = 20/20, accuracy of treatment within +/- 0.5 D, and loss of > or = 2 lines of best spectacle-corrected visual acuity (BSCVA) for the LADARVision4000 and STAR S2, respectively was: 89% vs 63%, 84% vs 80%, and 0.8% vs 3.8%. For hyperopic eyes 3 months postoperatively, the percentage of eyes with UCVA > or = 20/20, accuracy of treatment within +/- 0.5 D, and loss of > or = 2 lines of BSCVA for the LADARVision4000 and STAR S2, respectively was: 74% vs 33%, 69% vs 74%, and 2% vs 18.5%. CONCLUSIONS Although good results are evident for both platforms, superior results were observed with the Alcon LADARVision4000 laser.
Collapse
|
21
|
Netto MV, Mohan RR, Ambrósio R, Hutcheon AEK, Zieske JD, Wilson SE. Wound healing in the cornea: a review of refractive surgery complications and new prospects for therapy. Cornea 2005; 24:509-22. [PMID: 15968154 DOI: 10.1097/01.ico.0000151544.23360.17] [Citation(s) in RCA: 279] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
PURPOSE The corneal wound healing response is of particular relevance for refractive surgical procedures since it is a major determinant of efficacy and safety. The purpose of this review is to provide an overview of the healing response in refractive surgery procedures. METHODS Literature review. RESULTS LASIK and PRK are the most common refractive procedures; however, alternative techniques, including LASEK, PRK with mitomycin C, and Epi-LASIK, have been developed in an attempt to overcome common complications. Clinical outcomes and a number of common complications are directly related to the healing process and the unpredictable nature of the associated corneal cellular response. These complications include overcorrection, undercorrection, regression, corneal stroma opacification, and many other side effects that have their roots in the biologic response to surgery. The corneal epithelium, stroma, nerves, inflammatory cells, and lacrimal glands are the main tissues and organs involved in the wound healing response to corneal surgical procedures. Complex cellular interactions mediated by cytokines and growth factors occur among the cells of the cornea, resulting in a highly variable biologic response. Among the best characterized processes are keratocyte apoptosis, keratocyte necrosis, keratocyte proliferation, migration of inflammatory cells, and myofibroblast generation. These cellular interactions are involved in extracellular matrix reorganization, stromal remodeling, wound contraction, and several other responses to surgical injury. CONCLUSIONS A better understanding of the complete cascade of events involved in the corneal wound healing process and anomalies that lead to complications is critical to improve the efficacy and safety of refractive surgical procedures. Recent advances in understanding the biologic and molecular processes that contribute to the healing response bring hope that safe and effective pharmacologic modulators of the corneal wound healing response may soon be developed.
Collapse
Affiliation(s)
- Marcelo V Netto
- The Cole Eye Institute, The Cleveland Clinic Foundation, OH 44195, USA
| | | | | | | | | | | |
Collapse
|
22
|
Serrao S, Lombardo M. Corneal epithelial healing after photorefractive keratectomy: analytical study. J Cataract Refract Surg 2005; 31:930-7. [PMID: 15975458 DOI: 10.1016/j.jcrs.2004.12.041] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2004] [Accepted: 08/27/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To characterize the velocity of epithelial migration after photorefractive keratectomy (PRK) with 3 different corneal ablation patterns. SETTING Department of Ophthalmology, Catholic University of Rome, Rome, Italy. METHODS Fifteen patients (30 eyes) with mild to moderate myopia and with simple to compound myopic astigmatism were enrolled for this study. The surgical procedure consisted of standardized PRK with final smoothing performed using the Technolas Keracor 217C excimer laser. The reepithelialization process was evaluated at 0 hours, 20 hours, 40 hours, and 60 hours after surgery using a digital photo camera and custom software for measurement. Digital analysis of the images was performed. Corneal topographies were taken at 1 month, 3 months, 6 months, and 12 months after PRK. RESULTS The mean speed of radial migration in the 10 eyes (33%) in the low spherical ablation group was 0.087 mm/h +/- 0.008 (SD). This was significantly higher than that found in the 10 eyes (33%) in the high spherical ablation group (mean speed 0.078 +/- 0.007 mm/h; P<.001) and in the 10 eyes (33%) in the cross-cylinder ablation group (mean speed 0.055 +/- 0.014 mm/h; P<.001). CONCLUSION Analysis of the data shows that epithelial migration along the photoablated corneal surface depends on the ablation pattern. The epithelial sliding is highly influenced by local variations in the curvature of the stromal surface. The data demonstrate that faster epithelial wound healing after PRK is predictive of optimal visual performance.
Collapse
|
23
|
Rajan MS, Shafiei S, Mohrenfels CVW, Patmore A, Lohmann C, Marshall J, Hamberg-Nystrom H. Effect of exogenous keratinocyte growth factor on corneal epithelial migration after photorefractive keratectomy. J Cataract Refract Surg 2004; 30:2200-6. [PMID: 15474836 DOI: 10.1016/j.jcrs.2004.02.022] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/04/2004] [Indexed: 10/26/2022]
Abstract
PURPOSE To investigate the effect of topical keratinocyte growth factor (KGF) on wound healing after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK). SETTING Department of Ophthalmology, Rayne Institute, St. Thomas' Hospital, London, United Kingdom, St. Erick's Eye Hospital, Stockholm, Sweden, and the University of Regensberg, Regensberg, Germany. METHODS In a placebo-controlled trial, 24 New Zealand white female rabbits were divided into 3 equal groups. Group 1 (n=8) had myopic PRK (6.0 diopters [D]) using the Technolas 217z laser (Bausch & Lomb). Group 2 and Group 3 had myopic LASIK (6.0 D) with a flap depth of 140 microm and 180 microm, respectively. Topical KGF (20 microg/mL) was administered to half the treated eyes in each group intraoperatively and postoperatively; the other half received placebo eyedrops. Epithelial closure, corneal haze, and keratocyte activation in the rabbit eyes were analyzed and compared with those in placebo-controlled eyes for 5 weeks postoperatively. RESULTS In Group 1, the mean reepithelialization after PRK was 0.10 mm2/h +/- 0.02 (SD) in the KGF group and 0.33 +/- 0.05 mm2/h in the control group (P=.001). There was no significant difference in the mean backscatter between the KGF eyes (154 +/- 45.95) and the control eyes (141 +/- 38.45) after PRK (P=.42). Histology revealed reduced epithelial cell layers in the KGF group and comparable keratocyte density as in the control group. In Groups 2 and 3, there was no significant difference in backscatter, epithelial layers, and keratocyte density between KGF and control eyes after LASIK. CONCLUSIONS Topical KGF (20 microg/mL) delayed reepithelialization after PRK. It had no effect on stromal wound healing in LASIK eyes with an intact epithelial barrier.
Collapse
Affiliation(s)
- Madhavan S Rajan
- Department of Ophthalmology, Rayne Institute, St. Thomas' Hospital, London, United Kingdom.
| | | | | | | | | | | | | |
Collapse
|
24
|
Fraunfelder FW, Rich LF. Laser in situ Keratomileusis Using the Nidek EC-5000 or the Alcon LADARVision 4000 Systems. J Refract Surg 2004; 20:127-31. [PMID: 15072311 DOI: 10.3928/1081-597x-20040301-06] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the refractive results of eyes with low to moderate myopia that underwent laser in situ keratomileusis with either the Nidek EC-5000 or the Alcon LADARVision 4000 excimer laser systems. METHODS We performed a retrospective review of 114 LASIK procedures with either the Nidek EC-5000 (54 eyes) or the Alcon LADARVision 4000 (60 eyes) excimer laser systems. Preoperative refractive errors were similar and both populations were treated during the same time period. Data analyzed included uncorrected visual acuity (UCVA), spherical magnitude, spherical equivalent refraction, astigmatism power, astigmatism axis, and vector astigmatism change. RESULTS Results at 6 months were analyzed. Spherical correction change was a mean -3.95 D for Nidek treated eyes and a mean -4.53 D for LADARVision treated eyes (P = .20). Mean spherical equivalent refraction change was -3.70 D for Nidek eyes and -4.20 D for LADARVision eyes (P = .23). Mean change in UCVA (LogMAR) was 1.05 for Nidek eyes and 0.99 for LADARVision eyes (P = .40). Mean astigmatism magnitude change was 0.71 D for Nidek eyes and 0.77 D for LADARVision eyes (P = .63). Mean vector-corrected astigmatism change was 0.93 D for Nidek eyes and 1.00 D for LADARVision eyes (P = .63). Mean vector-corrected astigmatism axis for Nidek eyes was 3.08 D and for LADARVision eyes 6.58 D (P = .70). CONCLUSION There was no significant difference in refractive results in eyes treated with the Alcon LADARVision 4000 or the Nidek EC-5000 excimer laser systems. Inherent differences between the two laser systems are highlighted.
Collapse
|
25
|
Müller B, Boeck T, Hartmann C. Effect of excimer laser beam delivery and beam shaping on corneal sphericity in photorefractive keratectomy. J Cataract Refract Surg 2004; 30:464-70. [PMID: 15030843 DOI: 10.1016/s0886-3350(03)00559-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/30/2003] [Indexed: 10/26/2022]
Abstract
PURPOSE To evaluate the impact of beam delivery and beam shaping on corneal profiles after myopic excimer laser photorefractive keratectomy (PRK). SETTING Department of Ophthalmology, Charité-Campus Virchow Hospital, Humboldt University of Berlin, Berlin, Germany. METHODS Standard myopic 193 nm excimer laser PRK of -3.0 diopters (D) and -6.0 D was performed in porcine eyes using 2 commercially available broad-beam lasers with band-mask and fractal-mask beam shaping, 2 flying-spot lasers, and a scanning-slit laser. A silicone replica was obtained to preserve the corneal profile and was measured with a dynamic focusing topometry system. RESULTS The scanning-slit and flying-spot lasers created uniform profiles comparable to those in an untreated control group. Both broad-beam lasers with band-mask and fractal-mask beam shaping created central islands and paracentral profile valleys of 15.10 microm and 17.00 microm maximum height after -3.0 D PRK and 26.45 microm and 24.31 microm after -6.0 D PRK. An anti-central-island program, which applied a series of laser pulses centrally to compensate for the central profile elevations, did not eliminate the islands. Stromal surface roughness increased with ablation depth and was significantly worse after scanning-slit ablation than after broad-beam ablation. CONCLUSIONS Laser-induced deviations from the intended uniform corneal profiles were associated with broad-beam ablation and increased ablation depth and therefore lessened the predictability of the refractive outcomes. Scanning-slit and flying-spot systems produced predictably uniform corneal profiles.
Collapse
Affiliation(s)
- Bert Müller
- Department of Ophthalmology, Charité-Campus Virchow Hospital, Humboldt University of Berlin, Berlin, Germany.
| | | | | |
Collapse
|
26
|
Serrao S, Lombardo M. One-year Results of Photorefractive Keratectomy With and Without Surface Smoothing Using the Technolas 217C Laser. J Refract Surg 2004; 20:444-9. [PMID: 15523955 DOI: 10.3928/1081-597x-20040901-06] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess the efficacy, predictability, stability, and safety of a smoothing technique in patients with myopia immediately after photorefractive keratectomy (PRK) using a scanning-spot excimer laser. METHODS Using the Technolas 217C excimer laser, PRK was performed on 100 eyes of 54 patients. Ablation zone diameter was 6.0 mm and transition zone diameter was 9.0 mm. The eyes were randomized into two groups: in 50 eyes PRK alone was performed and in the other 50 eyes, a smoothing technique was performed after the initial ablation. Preoperative mean spherical equivalent refraction was -4.98 +/- 1.71 D in the PRK only group (range -2.25 to -8.60 D) and -4.82 +/- 1.61 D in the smoothing group (range -2.00 to -8.00 D). Follow-up was 12 months for all patients. RESULTS At 1 year after surgery, mean manifest spherical equivalent refraction was -0.61 +/- 0.50 D (range -2.25 to +0.62 D) in the PRK only group and in the smoothing group, +0.02 +/- 0.32 D (range -0.75 to +0.75 D). Postoperative regularity topographic indices were lower in the smoothing group than in the PRK group (P<.001). CONCLUSIONS Smoothing after PRK for correction of myopia up to -6.50 D increased surface regularity, as expressed by lower topography surface regularity indices, and reduced the incidence and severity of postoperative haze. We observed higher predictability throughout follow-up in the smoothing group, which may be addressed by a nomogram adjustment in the PRK only group.
Collapse
Affiliation(s)
- Sebastiano Serrao
- Catholic University of Rome, Department of Ophthalmology, Rome, Italy.
| | | |
Collapse
|
27
|
Kim TI, Yang SJ, Tchah H. Bilateral Comparison of Wavefront-guided Versus Conventional Laser in situ Keratomileusis With Bausch and Lomb Zyoptix. J Refract Surg 2004; 20:432-8. [PMID: 15523953 DOI: 10.3928/1081-597x-20040901-04] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE One aim of corneal refractive surgery is to correct defocus and astigmatism. In the process of correcting lower order aberrations, higher order ocular aberrations increase. To evaluate the effectiveness of wavefront-guided laser in situ keratomileusis (LASIK) in reducing the increase of higher order aberration, we compared aberrational change after LASIK with conventional and wavefront-guided customized ablation. METHODS Our study included 48 eyes of 24 patients. We performed conventional LASIK in one eye (Group 1) and wavefront-guided customized ablation in the other eye (Group 2). Ocular aberration was measured with the Zywave, a type of Shack-Hartmann aberrometer. We then compared low and high order aberrations, contrast sensitivity, visual acuity, corneal topography, and manifest refraction preoperatively and postoperatively at 1 and 3 months. RESULTS Uncorrected visual acuity improved to more than 20/20 in two eyes in the conventional ablation group and in five eyes in the customized ablation group. In the conventional ablation group, Root-mean-square for higher order (RMS(H)) was 0.215 preoperatively, 0.465 (216.3%) at 1 month, and 0.418 (194.4%) at 3 months. In the customized ablation group, RMS(H) was 0.207 preoperatively, 0.380 (183.6%) at 1 month, and 0.371 (179.2%) at 3 months after LASIK. Mesopic contrast sensitivity in the customized ablation group was higher than that in the conventional ablation group, but this change was not statistically significant. CONCLUSIONS Wavefront-guided customized ablation reduced the increase of high order aberrations resulting from LASIK. In terms of visual acuity, patient preference, and mesopic contrast sensitivity, wavefront-guided customized ablation produced slightly-but not statistically significant-better results.
Collapse
Affiliation(s)
- Tae-im Kim
- Department of Ophthalmology, College of Medicine, University of Ulsan, Asan Medical Center, Seoul, Korea
| | | | | |
Collapse
|
28
|
Lombardo M, Serrao S. Smoothing of the Ablated Porcine Anterior Corneal Surface Using the Technolas Keracor 217C and Nidek EC-5000 Excimer Lasers. J Refract Surg 2004; 20:450-3. [PMID: 15523956 DOI: 10.3928/1081-597x-20040901-07] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To demonstrate efficacy of a smoothing technique to increase regularity of the anterior corneal surface after photorefractive keratectomy (PRK), using two different excimer lasers. METHODS Spherical ablations of -10.00 D were performed on 11 fresh porcine corneas using either the Technolas Keracor 217C scanning-spot or the Nidek EC-5000 scanning-slit beam excimer laser. Following the procedure, we performed a phototherapeutic keratectomy treatment (smoothing technique) on half of the corneal surface. The smoothing technique was performed using a viscous solution of 0.25% sodium hyaluronate, which was spread on the cornea prior to the procedure. The ablation zone was 6 mm in diameter and the transition zone extended to 3 mm. The ablation depth was set at 10 microm. Corneas were then examined with scanning electron microscopy. RESULTS Smoother treatment zones were apparent in porcine corneas in which smoothing was performed following PRK, with both laser systems. Results from the two lasers were not directly compared. CONCLUSIONS The smoothing procedure performed following PRK using a viscous 0.25% sodium hyaluronate masking solution and a scanning laser system rendered the porcine corneal surface more regular.
Collapse
Affiliation(s)
- Marco Lombardo
- Catholic University of Rome, Department of Ophthalmology, Rome, Italy.
| | | |
Collapse
|
29
|
Mastropasqua L, Nubile M, Ciancaglini M, Toto L, Ballone E. Prospective Randomized Comparison of Wavefront-guided and Conventional Photorefractive Keratectomy for Myopia With the Meditec MEL 70 Laser. J Refract Surg 2004; 20:422-31. [PMID: 15523952 DOI: 10.3928/1081-597x-20040901-03] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To study refractive results and aberrometric changes in myopic patients treated with wavefront-guided photorefractive keratectomy (PRK) in comparison with standard PRK. METHODS Sixty eyes of 60 patients with myopic astigmatism were randomly divided into two groups. Group 1 included 30 eyes (mean spherical equivalent refraction -4.39 +/- 1.31 D; range -2.50 to -6.50 D) treated with wavefront-guided PRK using the WASCA workstation and the Asclepion Meditec flying spot MEL 70 excimer laser. Group 2 had 30 eyes (mean spherical equivalent refraction -4.33 +/- 1.22 D; range -2.50 to -6.50 D) that underwent conventional PRK using the same laser, and served as the control group. Wavefront analysis of high order aberrations was performed before and 6 months after surgery. RESULTS Postoperatively, wavefront error increased in both groups (5.0-mm wavefront aperture diameter). Six months after surgery, the eyes that received the WASCA ablation had a smaller increase in root-mean-square (RMS; 70% of increment) compared to the conventional PRK group (139% of increment) (P<.001). In the standard PRK group, all aberrations notably increased; in the wavefront-guided PRK group there was a smaller increase of trefoil and spherical aberrations (P<.001) and a decrease of coma aberrations (P<.001). The smaller increase of wavefront error in the wavefront-guided PRK group compared to the standard PRK group was more evident when preoperative RMS values were higher than 0.4 microm (P<.01). The visual parameters (spherical equivalent refraction, uncorrected and best spectacle-corrected visual acuity) did not show significant differences between the two groups. CONCLUSION Wavefront-guided PRK induced a smaller increase of postoperative wavefront-error compared to conventional PRK, particularly in patients with higher preoperative higher order aberrations.
Collapse
Affiliation(s)
- Leonardo Mastropasqua
- Department of Medicine and Aging Science and Section of Ophthalmology, University of Chieti, Italy.
| | | | | | | | | |
Collapse
|
30
|
Lafond G, Solomon L, Bonnet S. Retreatment to Enlarge Small Excimer Laser Optical Zones Using Combined Myopic and Hyperopic Ablations. J Refract Surg 2004; 20:46-52. [PMID: 14763471 DOI: 10.3928/1081-597x-20040101-09] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE We describe a retreatment technique using a combination of large-diameter myopic and hyperopic excimer laser ablations of a near equivalent diopter value to enlarge previous small ablation zones without altering the refractive result obtained by the initial surgery. METHODS Eight eyes of six patients were retreated with a Technolas Keracor 217 laser in order to enlarge the optical zone. All patients had a good refractive result after the initial surgery, but reported halos under low light conditions. Retreatment consisted of a combination of myopic and hyperopic ablations of near equivalent value, eg, -1.00 D and +1.00 D treatment. These opposite value ablations should neutralize their respective refractive effect, but by removing a larger diameter of tissue, actually displace the transition zones further toward the corneal periphery. Although the initial treatment used photorefractive keratectomy in four of the eight eyes, LASIK was used for retreatment in all eyes. Improvement was assessed subjectively by the patient and was measured objectively with a Technomed C-Scan ray-tracing program. RESULTS In six of eight eyes, patients experienced moderate or marked improvement. This improvement was objectively correlated on postoperative corneal topography. CONCLUSION Combined larger diameter myopic and hyperopic retreatment seems to be safe and effective for enlarging previous small treatment zones, reducing symptoms such as halos in selected patients.
Collapse
Affiliation(s)
- Gilles Lafond
- Centre Hospitalier de l'Université Laval, Quebec City, Canada.
| | | | | |
Collapse
|
31
|
Seward MS, Oral D, Bowman RW, El-Agha MSH, Cavanagh HD, McCulley JP. Comparison of LADARVision and Visx Star S3 laser in situ keratomileusis outcomes in myopia and hyperopia. J Cataract Refract Surg 2003; 29:2351-7. [PMID: 14709296 DOI: 10.1016/s0886-3350(03)00328-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE To compare visual outcomes with 2 commonly used excimer lasers, the Autonomous LADARVision (LV) (Alcon Laboratories Inc.) and the Visx Star S3 (S3), in the performance of myopic and hyperopic astigmatic laser in situ keratomileusis (LASIK). SETTING Zale Lipshy University Hospital Laser Center for Vision, University of Texas Southwestern Medical Center, Dallas, Texas, USA. METHODS In this retrospective single-center 3-surgeon cohort comparison, 100 consecutive LV-treated myopic eyes with a mean manifest refraction spherical equivalent (MRSE) of -3.22 diopters (D) (range 0 to -6.00 D) (mean astigmatism 0.95 D [range 0 to 4.00 D]) were compared with 100 consecutive S3-treated eyes with a similar MRSE (mean MRSE -3.19 D; mean astigmatism 0.66 D [range 0 to 2.75 D]). Forty-one consecutive LV-treated hyperopic eyes with a mean MRSE of +2.59 D (range +1.00 to +6.00 D) (mean astigmatism 0.89 D [range 0 to 3.50 D]) were compared with 25 consecutive S3-treated eyes with a similar MRSE (mean MRSE +2.70 D; mean astigmatism 0.87 D [range 0 to 2.75 D]). The following outcomes were compared: uncorrected visual acuity, refractive predictability and stability, gain or loss of best spectacle-corrected visual acuity, and need for enhancement. RESULTS Statistically significant differences in outcomes were found between lasers in the treatment of hyperopia and hyperopic astigmatism. No outcome differences between lasers were found in the treatment of myopia and myopic astigmatism. CONCLUSION The LV and S3 lasers yielded equivalent results in myopic LASIK between 0 and -6.00 D; however, the LADARVision yielded statistically significantly better results in hyperopic LASIK between +1.00 and +6.00 D.
Collapse
Affiliation(s)
- Michael S Seward
- Department of Ophthalmology, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390, USA
| | | | | | | | | | | |
Collapse
|
32
|
Comaish IF, Lawless MA. Progressive post-LASIK keratectasia: biomechanical instability or chronic disease process? J Cataract Refract Surg 2002; 28:2206-13. [PMID: 12498861 DOI: 10.1016/s0886-3350(02)01698-x] [Citation(s) in RCA: 101] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Progressive post-LASIK keratectasia (PPLK) is a progressive deformation of corneal anatomy that occurs rarely but may have severe consequences. Using the scientific literature and new hypotheses, we attempted to determine whether PPLK is a biomechanical result of laser in situ keratomileusis (LASIK), a chronic disease process affecting individuals predisposed to the condition, or a combination of processes. We look at whether the combination of fatigue, specifically a form of dynamic fatigue, and proteolysis provides an environment conducive to the occurrence and progression of PPLK. This review may raise more questions than it answers and in so doing may move us toward a better understanding of this occasionally serious consequence of LASIK.
Collapse
Affiliation(s)
- Ian F Comaish
- The Eye Institute, 270 Victoria Avenue, Chatsworth, New South Wales 2067, Australia
| | | |
Collapse
|