Cheng S, Zhang J, Zhou K, Li T, Lin J, Yu AY. Repeatability and agreement of two swept-source optical coherence tomographers and scheimpflug imaging for measurements of corneal curvature. BMC Ophthalmol 2024; 24:439. [PMID: 39375665 DOI: 10.1186/s12886-024-03696-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 09/24/2024] [Indexed: 10/09/2024] Open
Abstract
PURPOSE To evaluate the repeatability and agreement of two swept-source optical coherence tomographers and Scheimpflug imaging for corneal curvature in healthy subjects to obtain data on the clinical application of a new device. METHODS This prospective study was conducted in January and February 2021 with 100 healthy subjects at the Eye Hospital of Wenzhou Medical University. Simulated keratometry (Sim-K), posterior keratometry (Kp), total corneal power (TCP), and total corneal astigmatism (TCA) were measured with CASIA2, Anterion, and Pentacam. Within-subject standard deviation (Sw), repeatability coefficient (RC), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were used to assess inter-device repeatability. Bland-Altman analysis was performed to determine inter-device agreement. RESULTS The three devices showed good repeatability for Sim-K, Kp, and TCP with all ICC > 0.980. Pentacam showed the highest repeatability (ICC ≥ 0.993; ICC ≥ 0.993) while the CASIA2 demonstrated the lowest repeatability (ICC: ≥ 0.986; ICC: ≥ 0.985) for Sim-K and TCP. Anterion and CASIA2 revealed better repeatability (ICC ≥ 0.998; ICC ≥ 0.981) for Kp than Pentacam (ICC ≥ 0.980). Pentacam and Anterion showed good repeatability for TCA (ICC: 0.935 and 0.916), whereas the CASIA2 showed moderate repeatability (ICC: 0.836). Three instruments demonstrated good agreement with the maximum absolute 95% Limits of agreement (LoA) of 1.00 D for Sim-K, Kp, and TCP. Wide LoA were found for TCA with the maximum absolute 95% LoA ≥ 0.66 D between the three devices. CONCLUSIONS In healthy subjects, the three devices (Pentacam, Anterion and CASIA2) displayed comparable repeatability and accuracy for SimK, Kp, and TCP, and could be used interchangeably for these parameters. However, TCA measured by the three devices was not interchangeable. TRIAL REGISTRATION Chinese Clinical Trial Registry Center (10/10/2020, ChiCTR2000038959).
Collapse
Affiliation(s)
- Shiming Cheng
- School of Ophthalmology and Optometry, Eye Hospitaland, Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, Zhejiang, 325027, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
- Ophthalmology Department, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei, China
| | - Jiasheng Zhang
- School of Ophthalmology and Optometry, Eye Hospitaland, Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, Zhejiang, 325027, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Kaijing Zhou
- School of Ophthalmology and Optometry, Eye Hospitaland, Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, Zhejiang, 325027, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Tiantian Li
- School of Ophthalmology and Optometry, Eye Hospitaland, Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, Zhejiang, 325027, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Junhai Lin
- School of Ophthalmology and Optometry, Eye Hospitaland, Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, Zhejiang, 325027, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - A-Yong Yu
- School of Ophthalmology and Optometry, Eye Hospitaland, Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, Zhejiang, 325027, China.
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China.
| |
Collapse
|
2
|
Niazi S, Doroodgar F, Hashemi Nazari S, Rahimi Y, Alió Del Barrio JL, Gatzioufas Z, Findl O, Vinciguerra P, Vinciguerra R, Moshirfar M, Ambrósio R, Alio JL. Refractive surgical approaches to keratoconus: A systematic review and network meta-analysis. Surv Ophthalmol 2024; 69:779-788. [PMID: 38710236 DOI: 10.1016/j.survophthal.2024.04.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 04/25/2024] [Accepted: 04/29/2024] [Indexed: 05/08/2024]
Abstract
Advancements in diagnostic methods and surgical techniques for keratoconus (KC) have increased non-invasive treatment options. Successful surgical planning for KC involves a combination of clinical science, empirical evidence, and surgical expertise. Assessment of disease progression is crucial, and halting the progression should be the focus if it is progressive. While surgeons used to rely on experience alone to decide the surgical method, comparing the network of primary factors, such as visual acuity, across studies can help them choose the most appropriate treatments for each patient and achieve optimal outcomes. Meticulous tabulation methods facilitate interpretation, highlighting the importance of selecting the correct surgical and rehabilitation approach based on each patient's condition and stage of the disease. We detail the outcomes of a comprehensive network meta-analysis comparing the effectiveness of various combined therapeutic refractive treatments for KC at identical stages of the disease, spanning 4 distinct follow-up intervals. Additionally, the comprehensive analysis suggests that for corneas with optimal best corrected visual acuity (BCVA) preoperatively (classified as regular), combining phakic intraocular lenses with intracorneal ring segments (ICRS) and corneal cross-linking (CXL) could offer the best therapeutic approach provided the disease stage does not exceed stage 3. For irregular corneas, although initial follow-ups show a significant difference in BCVA with surface ablation, longer-term follow-ups recommend combining surface ablation with ICRS and CXL, especially at higher stages.
Collapse
Affiliation(s)
- Sana Niazi
- Negah Aref Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Translational Ophthalmology Research Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Farideh Doroodgar
- Negah Aref Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Translational Ophthalmology Research Center, Tehran University of Medical Sciences, Tehran, Iran.
| | - Saeed Hashemi Nazari
- Prevention of Cardiovascular Disease Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Yekta Rahimi
- Student Research Committee, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Jorge L Alió Del Barrio
- Vissum Miranza, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | | | - Oliver Findl
- Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Hanusch Hospital, 1140 Vienna, Austria
| | - Paolo Vinciguerra
- Biomedical Sciences, Humanitas University, Milan, Italy; IRCCS Humanitas Research Hospital, Rozzano, Italy
| | | | - Majid Moshirfar
- John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Renato Ambrósio
- Instituto de Olhos Renato Ambrósio, Rio de Janeiro, Brazil; Rio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, Brazil; BrAIN: Brazilian Artificial Intelligence Networking in Medicine, Rio de Janeiro, Maceió, Brazil; Department of Ophthalmology, Federal University the state of Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil; Department of Ophthalmology, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Jorge L Alio
- Vissum Miranza, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| |
Collapse
|
3
|
D'Oria F, Bagaglia SA, Alio Del Barrio JL, Alessio G, Alio JL, Mazzotta C. Refractive surgical correction and treatment of keratoconus. Surv Ophthalmol 2024; 69:122-139. [PMID: 37774800 DOI: 10.1016/j.survophthal.2023.09.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 09/21/2023] [Accepted: 09/25/2023] [Indexed: 10/01/2023]
Abstract
Keratoconus is an ectatic corneal disorder that causes severe vision loss. Surgical options allow us to correct, partially or totally, the induced refractive error. Intracorneal ring segments (ICRS) implantation represents a minimally invasive surgical option that improves visual acuity, with a high success rate and a low overall complication rate. Corneal allogenic ICRS consists of ring segments derived from allogenic eye bank-processed donor corneas. Selective topography-guided transepithelial photorefractive or phototherapeutic keratectomy combined with CXL is another way in selected cases to improve spectacles corrected distance visual acuity. The microphotoablative remodeling of the central corneal profile is generally planned by optimizing the optical zones and minimizing tissue consumption. Phakic intraocular lens (PIOL) implant is considered in patients with stable disease and acceptable anatomical requirements. The two types of pIOLs, depending on their implantation inside the eye, are anterior chamber-pIOLs, which fixate to the anterior surface of the iris by using a polymethomethacrolate claw at the two haptics, and posterior chamber-pIOLs. In patients with both cataracts and keratoconus, the correct IOL power is difficult to obtain due to the irregular corneal shape and K values. Toric IOL is recommended, but carefully judging the topography and the possible need of subsequent keratoplasties.
Collapse
Affiliation(s)
- Francesco D'Oria
- Section of Ophthalmology, Department of Basic Medical Science, Neuroscience and Sense Organs, University of Bari, Bari, Italy.
| | - Simone A Bagaglia
- Departmental Ophthalmology Unit, Sant' Andrea Hospital, USL Toscana Sud-Est, Massa Marittima, Italy
| | - Jorge L Alio Del Barrio
- Vissum Miranza, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain
| | - Giovanni Alessio
- Section of Ophthalmology, Department of Basic Medical Science, Neuroscience and Sense Organs, University of Bari, Bari, Italy
| | - Jorge L Alio
- Vissum Miranza, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain.
| | - Cosimo Mazzotta
- Departmental Ophthalmology Unit, AUSL Toscana Sud Est, Campostaggia, Siena, Italy; Department of Medicine, Surgery and Neurosciences, Postgraduate Ophthalmology School, Siena University, Siena, Italy; Siena Crosslinking Center, Siena, Italy
| |
Collapse
|
4
|
Fard AM, Patel SP, Nader ND. The efficacy of 2 different phakic intraocular lens implant in keratoconus as an isolated procedure or combined with collagen crosslinking and intra-stromal corneal ring segments: a systematic review and meta-analysis. Int Ophthalmol 2023; 43:4383-4393. [PMID: 37470861 DOI: 10.1007/s10792-023-02813-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 07/10/2023] [Indexed: 07/21/2023]
Abstract
PURPOSE To compare the efficacy of phakic intra-ocular lenses in isolation or in combination with corneal crosslinking (CXL) and/or intra-stromal corneal ring segments (ICRS) in keratoconus. METHODS Data extracted from the publications meeting the selection. The outcome parameters included mean pre- and post-operative uncorrected distance visual acuity, corrected distance visual acuity (CDVA), sphere and cylinder of refraction and complications. Available data analyzed with Cochrane Review Manager. RESULTS A total of 23 studies including 464 eyes were included. All the parameters showed significant improvement in all subgroups other than CDVA in ACPIOL + CXL subgroup and cylinder in PIOL + CXL subgroups. There was not a significant difference between PCPIOL and ACPIOL in the outcomes, exception was more improvement of CDVA in "ACPIOL only" than" PCPIOL only" subgroup. CONCLUSION Both PCPIOLs and ACPIOLs are comparably safe and efficient options in management of KCN and their efficacy significantly improves when combined with CXL/ICRS.
Collapse
Affiliation(s)
- Ali Mahdavi Fard
- Department of Ophthalmology, Ross Eye Institute, Jacobs School of Medicine and Biomedical Sciences, State University of New York at Buffalo, Buffalo, NY, USA
- Department of Ophthalmology, Doheny Eye Center of UCLA, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| | - Sangita P Patel
- Department of Ophthalmology, Ross Eye Institute, Jacobs School of Medicine and Biomedical Sciences, State University of New York at Buffalo, Buffalo, NY, USA
- Research and Ophthalmology Services, Veterans Administration of Western New York Healthcare System, Buffalo, NY, USA
| | - Nader D Nader
- Department of Anesthesiology, Jacobs School of Medicine and Biomedical Sciences, State University of New York at Buffalo, Buffalo, NY, USA.
| |
Collapse
|
5
|
Yang K, Fan Q, Xu L, Gu Y, Pang C, Ren S. Accuracy of tomographic and biomechanical parameters in detecting unilateral post-LASIK keratoectasia and fellow eyes. Front Bioeng Biotechnol 2023; 11:1181117. [PMID: 37334265 PMCID: PMC10272423 DOI: 10.3389/fbioe.2023.1181117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 05/22/2023] [Indexed: 06/20/2023] Open
Abstract
Background: Patients with unilateral post-LASIK keratectasia (KE) have clinical ectasia in one eye but not in the fellow eye. As serious complications, these cases are rarely reported but are worth investigating. This study aimed to explore the characteristics of unilateral KE and the accuracy of corneal tomographic and biomechanical parameters to detect KE and distinguish fellow eyes from control eyes. Methods: The study analyzed 23 KE eyes, 23 KE fellow eyes, and 48 normal eyes from age- and sex-matched patients who had undergone LASIK. The Kruskal-Wallis test and further paired comparisons were performed to compare the clinical measurements of the three groups. The receiver operating characteristic curve was used to evaluate the ability to distinguish KE and fellow eyes from the control eyes. Binary logistic regression with the forward stepwise method was performed to produce a combined index, and the DeLong test was used to compare the discriminability difference of the parameters. Results: Males accounted for 69.6% of patients with unilateral KE. The duration between corneal surgery and the onset of ectasia ranged from 4 months to 18 years, with a median time of 10 years. The KE fellow eye had a higher posterior evaluation (PE) value than the control eyes (5 vs. 2, p = 0.035). Diagnostic tests showed that PE, posterior radius of curvature (3 mm), anterior evaluation (FE), and Corvis biomechanical index-laser vision correction (CBI-LVC) were sensitive indicators for distinguishing KE in the control eyes. The ability of PE to detect the KE fellow eye from the control eye was 0.745 (0.628 and 0.841), with 73.91% sensitivity and 68.75% specificity at a cut-off value of 3. The ability of a combined index, constructed using PE and FE, to distinguish fellow eyes of KE from controls was 0.831 (0.723 and 0.909), which was higher than that of PE and FE individually (p < 0.05). Conclusion: The fellow eyes of patients with unilateral KE had significantly higher PE values than control eyes, and a combination of PE and FE enhanced this differentiation in a Chinese population. More attention should be paid to the long-term follow-up of patients after LASIK and to be wary of the occurrence of early KE.
Collapse
|
6
|
Rubin A, Evans T, Hasrod N. Dioptric power and refractive behaviour: a review of methods and applications. BMJ Open Ophthalmol 2022; 7:e000929. [PMID: 35452207 PMCID: PMC8977790 DOI: 10.1136/bmjophth-2021-000929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 02/16/2022] [Indexed: 11/27/2022] Open
Abstract
Myopia is a global healthcare concern and effective analyses of dioptric power are important in evaluating potential treatments involving surgery, orthokeratology, drugs such as low-dose (0.05%) atropine and gene therapy. This paper considers issues of concern when analysing refractive state such as data normality, transformations, outliers and anisometropia. A brief review of methods for analysing and representing dioptric power is included but the emphasis is on the optimal approach to understanding refractive state (and its variation) in addressing pertinent clinical and research questions. Although there have been significant improvements in the analysis of refractive state, areas for critical consideration remain and the use of power matrices as opposed to power vectors is one such area. Another is effective identification of outliers in refractive data. The type of multivariate distribution present with samples of dioptric power is often not considered. Similarly, transformations of samples (of dioptric power) towards normality and the effects of such transformations are not thoroughly explored. These areas (outliers, normality and transformations) need further investigation for greater efficacy and proper inferences regarding refractive error. Although power vectors are better known, power matrices are accentuated herein due to potential advantages for statistical analyses of dioptric power such as greater simplicity, completeness, and improved facility for quantitative and graphical representation of refractive state.
Collapse
Affiliation(s)
- Alan Rubin
- Department of Optometry, University of Johannesburg - Doornfontein Campus, Johannesburg, Gauteng, South Africa
| | - Tanya Evans
- Department of Optometry, University of Johannesburg - Doornfontein Campus, Johannesburg, Gauteng, South Africa
| | - Nabeela Hasrod
- Department of Optometry, University of Johannesburg - Doornfontein Campus, Johannesburg, Gauteng, South Africa
| |
Collapse
|
7
|
Sakla HF, Altroudi W, Sakla YFR, Muñoz G, Pineza C. Visual and Refractive Outcomes of Toric Implantable Collamer Lens Implantation in Stable Keratoconus After Combined Topography-Guided PRK and CXL. J Refract Surg 2021; 37:824-829. [PMID: 34914551 DOI: 10.3928/1081597x-20210920-02] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of toric implantable Collamer lens (ICL) (STAAR Surgical) implanted at least 6 months after combined topography-guided photorefractive keratotomy (TG-PRK) and corneal cross-linking (CXL) in keratoconus. METHODS This retrospective study included 46 eyes with keratoconus of 31 patients who underwent toric ICL implantation after previous TG-PRK+CXL. Patients were examined for uncorrected (UDVA) and corrected (CDVA) distance visual acuity, flat and steep keratometry, and manifest refraction spherical equivalent preoperatively and 12 months postoperatively. RESULTS At 12 months postoperatively, there was a statistically significant improvement in visual and refractive outcomes (all P < .001). Mean UDVA improved to 0.17 ± 0.14 logMAR (vs 1.00 ± 0.38 logMAR preoperatively) and mean manifest refraction spherical equivalent improved to -0.32 ± 1.42 diopters (D) (vs -7.35 ± 5.20 D preoperatively). At 12 months, 63% of eyes achieved UDVA of 20/32 or better and 60.9% of eyes were within ±0.50 D of manifest refraction spherical equivalent. Mean refractive astigmatism improved from -2.90 ± 2.21 D preoperatively to -1.47 ± 1.46 D at postoperative 12 months (P < .001), with 30.4% and 45.7% of eyes having a postoperative astigmatic error within ±0.50 and ±1.00 D, respectively. No complications were observed. CONCLUSIONS Toric ICL implantation was found to be safe and effective for the correction of myopia and myopic astigmatism in patients with stable keratoconus who had undergone TG-PRK+CXL, as revealed by the statistically significant improvement in visual and refractive outcomes at 12 months after toric ICL implantation. [J Refract Surg. 2021;37(12):824-829.].
Collapse
|
8
|
Kalra N, Asif MI, Bafna RK, Sharma N, Sinha R. Posterior Chamber Phakic Intraocular Lens Implantation for Refractive Correction in Corneal Ectatic Disorders: A Review. J Refract Surg 2021; 37:351-359. [PMID: 34044697 DOI: 10.3928/1081597x-20210115-03] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To summarize the indications and outcomes of posterior chamber phakic intraocular lens (PIOL) implantation in corneal ectasias including keratoconus, pellucid marginal degeneration (PMD), post-refractive surgery, and post-keratoplasty ectasias. METHODS A review of the literature was conducted using the relevant keywords from various databases up to August 15, 2020. All pertinent studies were reviewed, and the relevant articles were studied in detail for efficacy, stability, predictability, and safety outcomes. In addition, visual quality, corneal biomechanical outcomes, complications, the role of posterior chamber PIOL in combination treatment, and comparison of posterior chamber PIOL with other PIOLs for ectasias were also evaluated. RESULTS A total of 30 relevant studies (13 prospective, 13 retrospective, 4 case reports) on the subject were studied and summarized. All studies showed a favorable refractive outcome. Quality of vision remained unaffected and no significant complications were reported in any of the studies. CONCLUSIONS Posterior chamber PIOLs represent a viable option in the treatment of mild to moderate and stable corneal ectasia in patients with contact lens intolerance who have low irregular astigmatism, a clear central cornea, and good preoperative corrected distance visual acuity. [J Refract Surg. 2021;37(5):351-359.].
Collapse
|
9
|
[Excimer laser in keratoconus management]. J Fr Ophtalmol 2021; 44:564-581. [PMID: 33573798 DOI: 10.1016/j.jfo.2020.08.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 08/12/2020] [Accepted: 08/24/2020] [Indexed: 11/21/2022]
Abstract
Visual rehabilitation in keratoconus is a challenge, notably because of the significant irregular astigmatism and optical aberrations that it induces. Many surgical techniques have been developed in addition to, or in the case of failure of, spectacles and rigid gas permeable contact lenses: intracorneal ring segments, intraocular lenses, excimer laser and, as a last resort, keratoplasty. Excimer laser photoablates the cornea, allowing remodeling of its surface. There are various treatment modes (wavefront-optimized, wavefront-guided and topography-guided), allowing performance of a customized treatment if needed. Its use in keratoconus has been described since the 2000s, alone or in combination with other procedures. For example, the combination of photoablation and corneal cross linking, a technique that increases corneal rigidity and in so doing can slow or even stop the progression of keratoconus, proved its efficacy and safety in many studies, and various protocols have been described. A triple procedure, including intracorneal ring segments, excimer laser and cross linking, has also given some very promising results in progressive keratoconus, providing a significative improvement in visual acuity and topographic data. The combination of excimer laser and intraocular lenses remains a poorly explored lead that might provide some satisfactory results. The objective of this review is to summarize the recent data on excimer laser in keratoconus management.
Collapse
|