1
|
Gabric I, Bohac M, Gabric K, Arba Mosquera S. First European results of a new refractive lenticular extraction procedure-SmartSight by SCHWIND eye-tech-solutions. Eye (Lond) 2023; 37:3768-3775. [PMID: 37277614 PMCID: PMC10698070 DOI: 10.1038/s41433-023-02601-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 05/05/2023] [Accepted: 05/19/2023] [Indexed: 06/07/2023] Open
Abstract
BACKGROUND To evaluate vision 3 months after SmartSight lenticule extraction treatments. DESIGN Case series. METHODS This case series of patients were treated at Specialty Eye Hospital Svjetlost in Zagreb, Croatia. Sixty eyes of 31 patients consecutively treated with SmartSight lenticule extraction were assessed. The mean age of the patients was 33 ± 6 years (range 23-45 years) at the time of treatment with a mean spherical equivalent refraction of -5.10 ± 1.35 D and mean astigmatism of 0.46 ± 0.36 D. Monocular corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA) were assessed pre- and post-operatively. Ocular and corneal wavefront aberrations have been postoperatively compared to the preoperative baseline values. Changes in ocular wavefront refraction, as well as changes in keratometric readings are reported. RESULTS At 3 months post-operatively, mean UDVA was 20/20 ± 2. Spherical equivalent showed a low myopic residual refraction of -0.37 ± 0.58 D with refractive astigmatism of 0.46 ± 0.26 D postoperatively. There was a slight improvement of 0.1 Snellen lines at 3-months follow-up. Compared to the preoperative status, ocular aberrations (at 6 mm diameter) did not change at 3 months follow-up; whereas corneal aberrations increased (+0.22 ± 0.21 µm for coma; +0.17 ± 0.19 µm for spherical aberration; and +0.32 ± 0.26 µm for HOA-RMS). The same correction was determined using changes in ocular wavefront refraction, as well as changes in keratometric readings. CONCLUSION Lenticule extraction after SmartSight is safe and efficacious in the first 3 months postoperatively. The post-operative outcomes indicate improvements in vision.
Collapse
Affiliation(s)
- Ivan Gabric
- Specialty Eye Hospital Svjetlost, School of Medicine University of Rijeka, Zagreb, Croatia
| | - Maja Bohac
- Specialty Eye Hospital Svjetlost, School of Medicine University of Rijeka, Zagreb, Croatia.
| | - Kresimir Gabric
- Specialty Eye Hospital Svjetlost, School of Medicine University of Rijeka, Zagreb, Croatia
| | | |
Collapse
|
2
|
Liu C, Lin MTY, Lee IXY, Mehta JS, Liu YC. Impact of corrected refractive power on the corneal denervation and ocular surface in small-incision lenticule extraction and LASIK. J Cataract Refract Surg 2023; 49:1106-1113. [PMID: 37867284 PMCID: PMC10583913 DOI: 10.1097/j.jcrs.0000000000001278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 07/27/2023] [Accepted: 07/28/2023] [Indexed: 10/24/2023]
Abstract
PURPOSE To evaluate the impact of corrected refractive power on the corneal denervation and ocular surface in small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK). SETTING Singapore National Eye Center, Singapore. DESIGN Prospective study. METHODS 88 eyes undergoing SMILE or LASIK were divided into low-moderate (manifest refractive spherical equivalent [MRSE] <-6.0 diopters [D]) and high myopic (MRSE ≥-6.0 D) groups. In vivo confocal microscopy and clinical assessments were performed preoperatively and at 1 month, 3 months, 6 months, and 12 months postoperatively. RESULTS In SMILE, high myopic treatment presented with significantly greater reduction in the corneal nerve fiber area (CNFA) and nerve fiber fractal dimension (CFracDim) compared with low-moderate myopic treatment (both P < .05). There was a significant and negative correlation between the corrected MRSE and the reduction in corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length, CNFA, and CFracDim after SMILE (r = -0.38 to -0.66, all P < .05). In LASIK, a significant correlation between the MRSE and the changes in CNBD, corneal nerve fiber total branch density, CNFA (r = -0.37 to -0.41), and corneal nerve fiber width (r = 0.43) was observed (all P < .05). Compared with SMILE, LASIK had greater reduction in CNBD and CNFA for every diopter increase in the corrected MRSE. High myopic SMILE, compared with low-moderate myopic SMILE, resulted in significantly lower tear break-up time at 1 and 6 months (both P < .05). The changes in CNFA and CFracDim were significantly associated with Schirmer test values (both P < .001). CONCLUSIONS Postoperative corneal denervation was related to corrected refractive power in both SMILE and LASIK. With the same refractive correction, LASIK led to more prominent corneal denervation.
Collapse
Affiliation(s)
- Chang Liu
- From the Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore (C. Liu, Lin, Lee, Mehta, Y.-C. Liu); Cornea and Refractive Surgery Group, Singapore Eye Research Institute, Singapore (C. Liu, Mehta); Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore (Mehta, Y.-C. Liu); Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore (Mehta, Y.-C. Liu); Department of Ophthalmology, National Taiwan University, Taiwan (Y.-C. Liu)
| | - Molly Tzu-Yu Lin
- From the Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore (C. Liu, Lin, Lee, Mehta, Y.-C. Liu); Cornea and Refractive Surgery Group, Singapore Eye Research Institute, Singapore (C. Liu, Mehta); Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore (Mehta, Y.-C. Liu); Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore (Mehta, Y.-C. Liu); Department of Ophthalmology, National Taiwan University, Taiwan (Y.-C. Liu)
| | - Isabelle Xin Yu Lee
- From the Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore (C. Liu, Lin, Lee, Mehta, Y.-C. Liu); Cornea and Refractive Surgery Group, Singapore Eye Research Institute, Singapore (C. Liu, Mehta); Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore (Mehta, Y.-C. Liu); Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore (Mehta, Y.-C. Liu); Department of Ophthalmology, National Taiwan University, Taiwan (Y.-C. Liu)
| | - Jodhbir S. Mehta
- From the Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore (C. Liu, Lin, Lee, Mehta, Y.-C. Liu); Cornea and Refractive Surgery Group, Singapore Eye Research Institute, Singapore (C. Liu, Mehta); Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore (Mehta, Y.-C. Liu); Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore (Mehta, Y.-C. Liu); Department of Ophthalmology, National Taiwan University, Taiwan (Y.-C. Liu)
| | - Yu-Chi Liu
- From the Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore (C. Liu, Lin, Lee, Mehta, Y.-C. Liu); Cornea and Refractive Surgery Group, Singapore Eye Research Institute, Singapore (C. Liu, Mehta); Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore (Mehta, Y.-C. Liu); Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore (Mehta, Y.-C. Liu); Department of Ophthalmology, National Taiwan University, Taiwan (Y.-C. Liu)
| |
Collapse
|
3
|
Bohač M, Gabrić I, Gabrić K, Jagić M, Arba Mosquera S. Predictability of the Achieved Lenticule Thickness in Keratorefractive Lenticule Extraction for Myopia Correction. J Refract Surg 2023; 39:728-735. [PMID: 37937760 DOI: 10.3928/1081597x-20230925-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
PURPOSE To assess the predictability between the SCHWIND ATOS femtosecond laser (SCHWIND eye-tech-solutions) read-out and achieved lenticule thickness measured using MS-39 anterior segment optical coherence tomography (ASOCT; CSO) at the corneal vertex at postoperative 1 day and 1 and 3 months of follow-up. METHODS This retrospective case series included 130 eyes of 65 consecutive patients who were treated with SmartSight (SCHWIND eye-tech-solutions) lenticule extraction. Sixty-four percent of patients were women with a mean spherical refraction of -4.98 ± 1.19 diopters (D) and mean astigmatism of 0.53 ± 0.64 D. The measurements were performed using AS-OCT with the Phoenix Software v 4.1.1.5. Lenticule thickness was obtained by the subtraction method between preoperative and postoperative total corneal thickness. RESULTS A lower reduction in central corneal thickness (CCT) compared to the laser read-out for all three follow-up visits can be observed. Essentially, the reduction in CCT was identical at 3 months versus 1 month. The reduction in CCT was lowest at postoperative 1 day. Examining the 1- and 3-month data (essentially equivalent), one can see a best fit of y = 0.94 x -7 µm. CONCLUSIONS The reduction in CCT was stable from 1 month of follow-up. The stable reduction in CCT was -6% (-1.5% after accounting for design decisions) and -7 µm lower than the respective laser read-out. The findings are predictable, showing a certain level of the lenticules becoming slightly thinner than their respective laser read-outs. [J Refract Surg. 2023;39(11):728-735.].
Collapse
|
4
|
Pradhan KR, Arba Mosquera S. Comparing high and low energy outcomes on day one for SmartSight myopic-astigmatism treatments with the SCHWIND ATOS: a retrospective case series. BMC Ophthalmol 2023; 23:328. [PMID: 37464345 DOI: 10.1186/s12886-023-03076-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 07/12/2023] [Indexed: 07/20/2023] Open
Abstract
BACKGROUND Impact of low energy asymmetric spacings vs. high energy symmetric spacings on the immediate/early (postoperative day 1 (POD1)) outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS The first 112 eyes of 56 patients consecutively treated using low energy asymmetric spacings (Group A; Study group) were compared at POD1 to the last 112 eyes of 56 patients consecutively treated using high energy symmetric spacings (Group S; Controls). Mean age of the patients was 28 ± 5 years with a mean spherical equivalent of -4.41 ± 1.76 diopters (D) and a mean magnitude of refractive astigmatism of 0.89 ± 0.82 D. RESULTS Laser Energy was -25 ± 1nJ lower for asymmetric treatments (p < .0001); Spot and Track distances were + 0.7 ± 0.1 µm larger and -0.8 ± 0.1 µm tighter for asymmetric treatments, respectively (p < .0001 for both). At POD1, astigmatism was -0.08 ± 0.02D lower for asymmetric treatments (p < .0003); uncorrected and corrected visual acuities (UDVA and CDVA, respectively) were -0.03 ± 0.01logMAR better for asymmetric treatments (p < .0007); differences between postop UDVA and preop CDVA along with change in CDVA were + 0.3 ± 0.1lines better for asymmetric treatments (p < .0003). CONCLUSIONS Lenticule extraction treatment using SmartSight is safe and efficacious already at POD1. Findings suggest that low energy asymmetric spacings may further improve the immediate and short-term outcomes of SmartSight lenticule extraction in the treatment of myopic astigmatism compared to conventional settings (high energy symmetric spacings).
Collapse
Affiliation(s)
- Kishore Raj Pradhan
- Matrika Eye Center, Dhunge Dhara Marg, Ward number 9, Kathmandu, 44600, Nepal
| | | |
Collapse
|
5
|
Ichikawa K, Ichikawa K, Yamamoto N, Horai R. Flexural and Cell Adhesion Characteristic of Phakic Implantable Lenses. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1282. [PMID: 37512093 PMCID: PMC10385999 DOI: 10.3390/medicina59071282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/06/2023] [Accepted: 07/08/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: In this study, we aimed to compare the physical properties of hole-implantable collamer lenses (H-ICLs) and implantable phakic contact lenses (IPCLs) and investigate their flexural and cell adhesion characteristics. Materials and Methods: Transverse compression load to achieve lens flexion and static Young's modulus were measured in H-ICLs and IPCLs using designated equipment. Load was measured both with and without restraining the optic section of the lenses. Adhesion of iHLEC-NY2 cells to the lens surfaces was examined using phase-contrast microscopy, and cell proliferation activity was evaluated using WST-8 assay. Results: The H-ICL showed a greater tendency for transverse compression load compared to IPCL, while the IPCL showed a higher Young's modulus with respect to the force exerted on the center of the anterior surface of the optic section. The joint between the optic section and haptic support in the IPCL was found to mitigate the effects of transverse compression load. Both lens types showed minimal cell adhesion. Conclusions: Our findings indicate that H-ICLs and IPCLs exhibit distinct physical properties and adhesive characteristics. The IPCL demonstrated higher Young's modulus and unique structural features, while the H-ICL required greater transverse compression load to achieve the flexion required to tuck the haptic supports into place behind the iris to fix the lens. The observed cell non-adhesive properties for both lens types are promising in terms of reducing complications related to cell adhesion. However, further investigation and long-term observation of IPCL are warranted to assess its stability and potential impact on the iris. These findings contribute to a better understanding of the performance and potential applications of H-ICLs and IPCLs in ophthalmology.
Collapse
Affiliation(s)
| | - Kei Ichikawa
- Chukyo Eye Clinic, Nagoya 456-0032, Aichi, Japan
- General Aoyama Hospital, Toyokawa 441-0103, Aichi, Japan
| | - Naoki Yamamoto
- Support Office for Bioresource Research, Translational Research Headquarters, Fujita Health University, Toyoake 470-1192, Aichi, Japan
| | - Rie Horai
- Chukyo Eye Clinic, Nagoya 456-0032, Aichi, Japan
| |
Collapse
|
6
|
Pradhan KR, Arba Mosquera S. Twelve-month outcomes of a new refractive lenticular extraction procedure. JOURNAL OF OPTOMETRY 2023; 16:30-41. [PMID: 34949535 PMCID: PMC9811368 DOI: 10.1016/j.optom.2021.11.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 11/02/2021] [Accepted: 11/11/2021] [Indexed: 06/07/2023]
Abstract
BACKGROUND To evaluate the 12-month refractive and visual outcomes of Small Incision Guided Human-cornea Treatment (SmartSight®, SCHWIND eye-tech-solutions, Kleinostheim, Germany) in the treatment of myopia corrections with low to moderate astigmatism with the use of a new femtosecond laser system. METHODS 221 eyes of 114 patients consecutively treated with SmartSight lenticule extraction were assessed. The mean age of the patients was 28±6 years at the time of treatment with a mean spherical equivalent refraction of -6.26±2.17D and mean astigmatism of 0.92±0.68D. Monocular corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA) were assessed pre- and post-operatively. Refractive changes have been determined in terms of changes in refraction, as well as changes in keratometric readings. The changes in central epithelial thickness have been determined. RESULTS At twelve months post-operatively, mean UDVA was 20/21±2. Spherical equivalent showed a residual refraction of +0.48±0.31D with refractive astigmatism of 0.13±0.18D postoperatively. There was a slight decrease of -0.1 Snellen lines at 12-months follow-up. The same correction was determined using changes in refraction, as well as changes in keratometric readings. The central epithelial thickness increased by +3±2µm. Spherical equivalent correction within ±0.50D was achieved in 199 eyes (90%), and cylindrical correction in 221 (100%). Preoperative corrected distance visual acuity (CDVA) was 20/20 or better in 213 eyes (96%), and postoperative uncorrected (UDVA) was 20/20 or better in 205 eyes (93%). No eye had lost two or more Snellen lines of CDVA. CONCLUSIONS Myopic astigmatism correction with SmartSight provided good results for efficacy, safety, predictability, and visual outcomes at the twelve months of follow up. The central epithelial thickness barely increased by 3±2µm.
Collapse
Affiliation(s)
- Kishore Raj Pradhan
- Matrika Eye Center, Dhunge Dhara Marg, Ward number 9, Kathmandu 44600, Nepal.
| | | |
Collapse
|
7
|
Zaldivar R, Zaldivar R, Gordillo CH, Adamek P. Visual Acuity Improvement in Low, Moderate and High Myopia After Posterior-Chamber Phakic Implantable Collamer Lens Surgery in a Large Patient Cohort. Clin Ophthalmol 2023; 17:1179-1185. [PMID: 37096208 PMCID: PMC10122501 DOI: 10.2147/opth.s407492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 04/11/2023] [Indexed: 04/26/2023] Open
Abstract
Purpose To compare best-corrected visual acuity (BCVA) before and after implantable collamer lens (ICL) surgery in patients with low, moderate and high myopia. Methods A single-centre, prospective, registry-based study involving patients with myopia who received ICLs between October 2018 and August 2020. The study population was divided into three groups of subjects with low (from 0 to -6 D), moderate (-6 to -10 D) and high myopia (more than -10 D). We analysed uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), spherical equivalent (SE), differences between BCVA pre- and 1-month postoperative, and line gain in BCVA 1 month after surgery. Results A total of 770 eyes belonging to 473 patients were surgically intervened during the study period, of which 692 eyes completed 1 month of postoperative follow-up and were included in the study population. At 1-month follow-up, 478 eyes (69%) achieved a BCVA of 20/20, 599 (87%) obtained 20/25 or better, and 663 (96%) had a BCVA of 20/40 or better. We identified a significant improvement in BCVA (baseline 0.15±0.2 logMAR vs follow-up 0.07±0.2 logMAR, p<0.0001) and a significant reduction in SE (baseline -9.23±4.1 D, vs follow-up -0.21±0.8 D, p<0.0001), with a significant relationship between preoperative SE and line gain (r = -0.46, p<0.0001). We identified a significantly higher line gain among eyes with higher degrees of myopia (low myopia 0.22±0.69 lines compared to moderate myopia 0.56±1.1 lines and high myopia 1.51±1.9 lines, p<0.0001). Notably, 99.6% of eyes with a high grade of myopia achieved improvement to a low degree (less than -6 D) at follow-up. The safety and efficacy indexes were 0.083±0.1 and -0.001±0.1, respectively. Conclusion In this large patient cohort, ICL surgery was related to a significant line gain in BCVA, particularly among eyes with higher degrees of myopia.
Collapse
Affiliation(s)
- Roger Zaldivar
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
- Correspondence: Roger Zaldivar, Instituto Zaldivar, Av. Emilio Civit 701, Mendoza, Argentina, Email
| | | | | | - Pablo Adamek
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
| |
Collapse
|
8
|
Semiz F, Lokaj AS, Tanriverdi G, Caliskan G, Hima-Musa N, Semiz CE. Fresh Human Myopic Lenticule Intrastromal Implantation for Keratoconus Using SMILE Surgery in a Long-term Follow-up Study: Ultrastructural Analysis by Transmission Electron Microscopy. J Refract Surg 2022; 38:520-528. [PMID: 35947000 DOI: 10.3928/1081597x-20220713-02] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate new intrastromal histological structures that develop after myopic human lenticular implantation in keratoconus with femtosecond laser-assisted small incision lenticule extraction (SMILE) surgery using transmission electron microscopy. METHODS Sixty eyes with advanced keratoconus indicated for corneal transplantation were included in this study. Fresh myopic lenticular implants were placed in all eyes through SMILE surgery. Lenticular implants were extracted from patients with myopic refractive errors of the cornea, untreated keratoconus, and treated keratoconus following 1, 2, and 3 years of surgery. These five lenticular samples were examined under the electron microscope and compared. RESULTS Disorganized and thinned collagen fibers were observed in the stroma with degenerative stromal cells (telocyte-like cells and keratocytes) in the keratoconic cornea. Apoptotic bodies and cell debris were easily observed near the disorganized fibers. In contrast, the myopic refractive error of the control and treatment groups demonstrated well-organized parallel lamellar structures. Healthy keratocytes and telocyte-like cells were observed in samples obtained 1, 2, and 3 years after lenticular implantation. Thus, telocyte-like cells may be activated by appropriate stimuli, such as stem cells, and be involved in stromal regeneration. CONCLUSIONS Fresh myopic intrastromal lenticular implantation is a safe, economical, and reliable technique that leads to increased corneal thickness, improved visual acuity, and the regeneration of healthy keratocytes and telocyte-like cells that are involved in stromal regeneration. [J Refract Surg. 2022;38(8):520-528.].
Collapse
|