Kim BY, Jun I. Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices. KOREAN JOURNAL OF OPHTHALMOLOGY 2022; 36:338-349. [PMID: 35766048 PMCID: PMC9388890 DOI: 10.3341/kjo.2022.0025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 05/06/2022] [Indexed: 12/03/2022] Open
Abstract
Purpose To evaluate the clinical availability of a multifunctional ocular biometric unit, MR-6000, for simultaneous keratometry, tonometry, topography, and pachymetry evaluation, and compare anterior segment measurements with five other devices: autokeratometer (KR-1), Scheimpflug camera (Pentacam HR), swept-source optical coherence tomography (IOLMaster 700), Placido disk scanning-slit topography (Orbscan II), and noncontact tonometry (FT-1000). Methods Thirty eyes from thirty patients who visited Severance Hospital for cataract surgery were examined using MR-6000 and the other devices. The mean keratometry, central corneal thickness (CCT), white-to-white (WTW) distance, and intraocular pressure (IOP) values were compared. Repeated measures analysis of variance, Wilcoxon signed-rank test, intraclass correlation coefficient (ICC), and Bland-Altman plot were used to assess the correlation and agreement between devices. Results Thirty eyes of thirty patients were evaluated. Statistically significant differences in mean keratometry between MR-6000, KR-1, Pentacam HR, and IOLMaster 700 were not observed (p > 0.05). All five devices, including Orbscan II, had almost perfect agreement in measuring keratometry (ICC > 0.80, p < 0.05). CCT measured by MR-6000 was significantly different from that of Pentacam HR and Orbscan II measurements (p < 0.05) but correlated with that of Pentacam HR and Orbscan II measurements (ICC > 0.60, p < 0.05). The WTW distance measured by MR-6000 was not significantly different from that measured by IOLMaster 700 but was different from that measured by Orbscan II. IOP measured by MR-6000 was not correlated with FT-1000. Conclusions Keratometric values obtained through MR-6000 can be used interchangeably with other devices based on good correlation and agreement. However, the CCT, WTW, and IOP values were not interchangeable with a single multifunctional unit for cataract surgery preoperative examination.
Collapse
Affiliation(s)
- Bo Yi Kim
- Department of Ophthalmology, Institute of Vision Research, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea Corneal Dystrophy Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Ikhyun Jun
- Department of Ophthalmology, Institute of Vision Research, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea Corneal Dystrophy Research Institute, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
2
|
Ong APC, Zhang J, Vincent AL, McGhee CNJ. Megalocornea, anterior megalophthalmos, keratoglobus and associated anterior segment disorders: A review. Clin Exp Ophthalmol 2021; 49:477-497. [PMID: 34114333 DOI: 10.1111/ceo.13958] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 06/03/2021] [Indexed: 01/21/2023]
Abstract
Megalocornea and anterior megalophthalmos (megalocornea spectrum) disorders are typically defined by corneal diameter > 12.5 mm in the absence of elevated intraocular pressure. Clinical features overlap with keratoglobus but are distinct from buphthalmos and severe (globus) keratoconus. Megalocornea spectrum disorders and keratoglobus are primarily congenital disorders, often with syndromic associations; both can present with large and thin corneas, creating difficulty in diagnosis, however, only keratoglobus is typically progressive. Molecular genetics provide significant insight into underlying aetiologies. Nonetheless, careful clinical assessment remains intrinsic to diagnosis. Surgical management can be challenging due to the enlarged ciliary ring and weakened zonules in megalocornea spectrum disorders and the extreme corneal thinning of keratoglobus. In this review, the established literature on measurement of corneal diameter, diagnosis of megalocornea, anterior megalophthalmos and keratoglobus, differentiation from severe keratoconus, recent molecular genetics research and key surgical modalities in the management of these rare disorders are outlined and discussed.
Collapse
Affiliation(s)
- Aaron P C Ong
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.,Department of Ophthalmology, Southern District Health Board, Dunedin, New Zealand
| | - Jie Zhang
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Andrea L Vincent
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Charles N J McGhee
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
3
|
Oleszko AA, Marek JJ, Muzyka‐woźniak MM. Horizontal and anterior chamber diameter for phakic intraocular lens sizing. Clin Exp Optom 2021; 104:62-68. [DOI: 10.1111/cxo.13101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
|
4
|
Prakash G, Philip R, Bacero R, Srivastava D. Multivariate Analysis to Predict the Horizontal Anterior Chamber Diameter from Other Anterior Chamber Parameters Using Scheimpflug Imaging: Is There a Better Method Than Adding a Fixed Constant? Curr Eye Res 2016; 42:58-64. [PMID: 27266440 DOI: 10.3109/02713683.2016.1151529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To evaluate the predictive association between the horizontal anterior chamber diameter (HACD) and other measurements using Scheimpflug imaging, and to assess whether a method superior to using fixed constants can be proposed. METHODS This hospital-based study was performed in the Cornea and Refractive Surgery Services, New Medical Center (NMC) specialty hospital, Abu Dhabi. Initially, 100 candidates were included serially in the model building group (group1). All candidates underwent detailed evaluation and Scheimpflug imaging (CSO, Sirus, Italy). Subsequently, another 100 candidates were included serially in the validation group (group 2). Candidates in both groups underwent the same tests. RESULTS In group 1, the mean HACD was 12.25 ± 0.48 mm. This measurement correlated significantly with the horizontal visible iris diameter (HVID), anterior chamber depth, angle (ACA), and volume (ACV) (r = 0.2-0.7). The overall regression equation was HACD = 5.62 + 0.01 × ACV + 0.45 × HVID - 0.013 × ACA (adjusted R2 = 0.66, p < 0.001). Situation-based equations derived from the outcomes of group 1 were tested in group 2. Equation A included all factors found significant during model-building, Equation B included only non-volumetric significant factors, and situation C only included the HVID. Equations D through F used direct substitution by HVID plus a constant to predict HACD (the constant was 0.0, 0.5, and 1.0 for Equations D, E, and F, respectively). The predicted HACD (pHACD) was within ±0.5 mm of the actual HACD (aHACD) in 93%, 88%, 87%, 83%, 69%, and 16% case for Equations A, B, C, D, E, and F, respectively. The mean prediction error was -0.14 ± 0.27 mm (p = 0.08), -0.15 ± 0.28 mm (p = 0.03), -0.18 ± 0.30 mm (p = 0.001), -0.18 ± 0.32 mm (p < 0.001), 0.33 ± 0.35 mm (p < 0.001), and 0.83 ± 0.35 mm (p < 0.001) for Equations A, B, C, D, E, and F, respectively. CONCLUSION Regression equations using Scheimpflug-derived anterior chamber parameters may predict HACD to varying degrees, depending on the input parameters. Adding 0.5 or 1.0 mm to the corneal diameter (CD) to estimate the HACD is not recommended.
Collapse
Affiliation(s)
- Gaurav Prakash
- a Cornea and Refractive Surgery Services, NMC Eye Care , New Medical Center Specialty Hospital , Abu Dhabi , United Arab Emirates
| | - Reena Philip
- a Cornea and Refractive Surgery Services, NMC Eye Care , New Medical Center Specialty Hospital , Abu Dhabi , United Arab Emirates
| | - Ruthchel Bacero
- a Cornea and Refractive Surgery Services, NMC Eye Care , New Medical Center Specialty Hospital , Abu Dhabi , United Arab Emirates
| | - Dhruv Srivastava
- a Cornea and Refractive Surgery Services, NMC Eye Care , New Medical Center Specialty Hospital , Abu Dhabi , United Arab Emirates
| |
Collapse
|
5
|
Guber I, Bergin C, Perritaz S, Majo F. Correcting Interdevice Bias of Horizontal White-to-White and Sulcus-to-Sulcus Measures Used for Implantable Collamer Lens Sizing. Am J Ophthalmol 2016; 161:116-25.e1. [PMID: 26454242 DOI: 10.1016/j.ajo.2015.09.037] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2015] [Revised: 09/27/2015] [Accepted: 09/28/2015] [Indexed: 12/17/2022]
Abstract
PURPOSE To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN Interinstrument reliability and bias assessment study. METHODS A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Collapse
|
6
|
Domínguez-Vicent A, Pérez-Vives C, Ferrer-Blasco T, Albarrán-Diego C, Montés-Micó R. Interchangeability among five devices that measure anterior eye distances. Clin Exp Optom 2015; 98:254-62. [PMID: 25786342 DOI: 10.1111/cxo.12247] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Revised: 09/24/2014] [Accepted: 10/01/2014] [Indexed: 11/28/2022] Open
Abstract
PURPOSE The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance. METHODS Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500. RESULTS The Pentacam HR measured significantly greater ACD (p < 0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p > 0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically acceptable limits. The device comparison showed that for WTW distance measurements IOLMaster 500 yields the greatest value (p < 0.01), whereas CA-200F Corneal Analyser yields the smallest one (p < 0.01). CONCLUSION Pentacam HR, Orbscan II and IOLMaster 500 can be used interchangeably to measure ACD, whereas Orbscan II, IOLMaster 500, Castroviejo surgical calliper and CA-200F Corneal Analyser cannot be considered interchangeable, when it comes to measuring WTW distance.
Collapse
Affiliation(s)
| | - Cari Pérez-Vives
- Optometry Research Group (GIO), Optics Department, University of Valencia, Spain
| | - Teresa Ferrer-Blasco
- Optometry Research Group (GIO), Optics Department, University of Valencia, Spain
| | - César Albarrán-Diego
- Optometry Research Group (GIO), Optics Department, University of Valencia, Spain
| | - Robert Montés-Micó
- Optometry Research Group (GIO), Optics Department, University of Valencia, Spain
| |
Collapse
|
7
|
Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography–Placido disk device. J Cataract Refract Surg 2015; 41:372-81. [DOI: 10.1016/j.jcrs.2014.05.044] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 05/17/2014] [Accepted: 05/22/2014] [Indexed: 11/18/2022]
|
8
|
Huang J, Savini G, Li J, Lu W, Wu F, Wang J, Li Y, Feng Y, Wang Q. Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster. Br J Ophthalmol 2014; 98:1277-81. [DOI: 10.1136/bjophthalmol-2014-305150] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
9
|
Gharaee H, Abrishami M, Shafiee M, Ehsaei A. White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II. Int J Ophthalmol 2014; 7:309-12. [PMID: 24790875 DOI: 10.3980/j.issn.2222-3959.2014.02.20] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Accepted: 07/11/2013] [Indexed: 11/02/2022] Open
Abstract
AIM To determine the normative values of white-to-white corneal diameter with Orbscan II Topography System and to compare right and left eyes data in the normal young population. METHODS A total of 1001 healthy participants aged 18-45y participated in this observational cross-sectional study. The study population consisted of 616 female and 385 male subjects. The corneal diameter was measured with the Orbscan II. The differences between genders, between right and left eyes and age-related changes were evaluated. Statistical analyses were performed using Student's t-test. RESULTS The average white-to-white distance in our study population was recorded as 11.65±0.36 mm (median: 11.60 mm, mode: 11.70 mm, minimum: 10.50 mm and maximum: 13.60 mm). The white-to-white distance was 11.60±0.35 mm in males and 11.71±0.36 mm in females which was statistically different between genders (P<0.01). However, white-to-white distance was not statistically different between right and left eyes. In addition, this parameter decreased with increasing age. Considering 95% confidence interval, corneal diameter less than 10.93 mm and greater than 12.34 mm would be considered as microcornea and megalocornea, respectively based on this study population, using the Orbscan II topography. CONCLUSION Detailed description and analysis of corneal diameter with Orbscan demonstrate that the obtained average value of horizontal white-to-white is higher in male than female and decreases slightly with increasing age. Our data also suggests the cut off values for definition of microcornea and megalocornea, which can be employed with this population.
Collapse
Affiliation(s)
- Hamid Gharaee
- Cornea Research Center, Mashhad University of Medical Sciences, Mashhad 9195965919, Iran ; Eye Research Center, Mashhad University of Medical Sciences, Mashhad 9195965919, Iran
| | - Mojtaba Abrishami
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad 9195965919, Iran ; Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran 1336616351, Iran
| | - Masoud Shafiee
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad 9195965919, Iran
| | - Asieh Ehsaei
- Refractive Errors Research Centre, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad 9176699186, Iran ; Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad 9176699186, Iran
| |
Collapse
|
10
|
Rhee TK, Park JH, Kang HJ, Kwon YA, Song SW, Kim BY, Chung JL. Comparison of Anterior Segment Measurements Using Scanning-Slit Topography and Optical Low-Coherence Reflectometry (OLCR) Biometry. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2014. [DOI: 10.3341/jkos.2014.55.5.656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Taek Kwan Rhee
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Ji Hyun Park
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
- Daesung Yonsei Eye Clinic, Bucheon, Korea
| | - Hyo Jeong Kang
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
- Eyelove Eye Center, Daejeon, Korea
| | - Young A Kwon
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Sang Wroul Song
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Byoung Yeop Kim
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| | - Jae Lim Chung
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Myung-Gok Eye Research Institute, Seoul, Korea
| |
Collapse
|
11
|
Jung Y, Kim KH. Comparison of White-to-White Diameters Measured by IOLMaster, Lenstar, Orbscan, and a Manual Method. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2013. [DOI: 10.3341/jkos.2013.54.8.1187] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Yun Jung
- Department of Ophthalmology, Gachon University Gil Medical Center, Incheon, Korea
| | - Kyun Hyung Kim
- Department of Ophthalmology, Gachon University Gil Medical Center, Incheon, Korea
| |
Collapse
|
12
|
Repeatability and agreement of 2 Scheimpflug analyzers in measuring the central corneal thickness and anterior chamber angle, volume, and depth. Eur J Ophthalmol 2012; 22 Suppl 7:S29-32. [PMID: 22267453 DOI: 10.5301/ejo.5000102] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/05/2011] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the repeatability and agreement of 2 Scheimpflug tomographies (Pentacam HR, Oculus GmbH; Sirius, CSO Inc.) in measuring the central corneal thickness (CCT) and depth (ACD), volume (ACV), and angle (ACA) of the anterior chamber. METHODS Three consecutive measurements were performed in one eye of each subject, with both instruments. The following were evaluated: CCT, ACD, ACV, and ACA. Repeatability was assessed by the Friedman test and agreement was assessed by 4 different Wilcoxon tests for paired data. RESULTS The study enrolled 30 patients. With Sirius tomography the Friedman test p values for testing homogeneity across measurements was with respect to CCT 0.320, ACD 0.315, ACV 0.171, and ACA 0.020; and with Pentacam CCT 0.191, ACD 0.010, ACV 0.704, and ACA 0.150. The Wilcoxon test p values for testing the measurement homogeneity between the corneal tomography Sirius and Pentacam showed the following: ACD 0.000, ACD 0.000, ACV 0.853, and ACA 0.000. CONCLUSIONS The measurements may be considered substantially stable for each corneal tomography and each variable, but the 2 corneal tomographies do not produce statistically equivalent measurements.
Collapse
|
13
|
Kiraly L, Duncker G. Biometrie des vorderen Augensegmentes zur Implantation phaker Vorderkammerlinsen. Ophthalmologe 2012; 109:242-9. [DOI: 10.1007/s00347-011-2520-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|