1
|
Oatts JT, Han Y. Glaucoma Drainage Device Implantation, Outcomes, and Complications. Int Ophthalmol Clin 2023; 63:93-101. [PMID: 37755445 PMCID: PMC10807850 DOI: 10.1097/iio.0000000000000499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2023]
Abstract
Glaucoma drainage device (GDD) surgery has gained popularity as a treatment strategy for patients with medically uncontrolled glaucoma. Glaucoma is the leading cause of irreversible blindness in the world and continues to be a major public health issue. While our understanding of glaucoma continues to evolve, the primary treatment for glaucoma continues to be intraocular pressure (IOP) control. When medical treatment fails, glaucoma surgery is considered. GDD implantation is one of the most commonly performed incisional glaucoma surgeries. GDD was originally designed for patients with secondary glaucoma and/or patients who are at an increased risk of failure after trabeculectomy. More recently, its application has been extended to primary glaucoma as the first choice of incisional surgery. This manuscript summarizes recent GDD types, implantation, clinical outcome and complications.
Collapse
Affiliation(s)
- Julius T Oatts
- Department of Ophthalmology, University of California, San Francisco, San Francisco, CA
| | - Ying Han
- Department of Ophthalmology, University of California, San Francisco, San Francisco, CA
- Ophthalmology Section, Surgical Service, San Francisco Veterans Affairs Medical Center, San Francisco, California
| |
Collapse
|
2
|
Chen J, Elhusseiny AM, Khodeiry MM, Smith MP, Sayed MS, Banitt M, Feuer W, Yoo SH, Lee RK. Clinical Factors Impacting Outcomes From Failed Trabeculectomy Leading to Glaucoma Drainage Device Implantation and Subsequent Penetrating Keratoplasty. J Glaucoma 2023; 32:800-806. [PMID: 37171992 PMCID: PMC10524893 DOI: 10.1097/ijg.0000000000002239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Accepted: 04/12/2023] [Indexed: 05/14/2023]
Abstract
PRCIS We evaluated the factors that impacted time from glaucoma drainage implant (GDI) surgery to penetrating keratoplasty (PK) in eyes with previously clear corneas (ie, GDI-first sequence), and that specifically underwent a trabeculectomy before GDI surgery for intraocular pressure (IOP) control. PURPOSE To describe through an event-triggered data collection method the clinical course and the long-term outcomes of 2 procedures that are commonly performed sequentially in complex clinical situations: GDI surgery and PK. The study investigates the clinical factors associated with the progression to PK and determines the GDI success rate and graft survival. METHODS A single, tertiary-care center retrospective interventional cases series including patients with a sequential history of trabeculectomy, GDI surgery, and PK from 1999 to 2009. Outcome measures included IOP, visual acuity, graft failure, GDI failure, and time from GDI to PK. RESULTS Of the eyes, 56% had primary open angle glaucoma. The time from the last trabeculectomy to GDI was 66.5 ± 66.7 months. Of the eyes, 84% received a Baerveldt GDI. Time from GDI to PK was 36.4 ± 28.4 months. IOP at the time of PK was between 5 mm Hg and 21 mm Hg in 90% of eyes. At the last follow-up, 48% of grafts were clear. At 5 years post-PK, 33% of corneal grafts remained clear, whereas 81% of tubes remained functional. CONCLUSIONS Nearly half of the corneal grafts are clear at the last long-term follow-up. Graft failure occurs at a higher rate than tube failure suggesting that IOP control is only one and possibly not the most important factor in graft survival in eyes with prior glaucoma surgery.
Collapse
Affiliation(s)
- Jessica Chen
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
- Palo Alto Eye Group, 1805 El Camino Real, Palo Alto, CA 94306
| | - Abdelrahman M. Elhusseiny
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
- Harvey and Bernice Jones Eye Institute, University of Arkansas for Medical Sciences, Little Rock, AR, 72205
| | - Mohamed M. Khodeiry
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
- UPMC Children’s Hospital of Pittsburgh, Pittsburgh, Pennsylvania
| | - Michael P. Smith
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
- Eye Consultants of PA, 1 Granite Point, Wyomissing, PA 19610
| | - Mohamed S. Sayed
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
- Moorfields Eye Hospital, Dubai, UAE
| | - Michael Banitt
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
- Northwest Eye Surgeons, 332 Northgate Way, Seattle, WA 98125
| | - William Feuer
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
| | - Sonia H. Yoo
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
| | - Richard K. Lee
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine
| |
Collapse
|
3
|
Honda Y, Miyakoshi A, Tojo N, Hayashi A. Improvement of the loss of corneal endothelial cells by relocating the tip of the Baerveldt® implant tube from the anterior chamber to the vitreous cavity. Int Ophthalmol 2023; 43:2795-2801. [PMID: 36877315 DOI: 10.1007/s10792-023-02677-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 02/25/2023] [Indexed: 03/07/2023]
Abstract
PURPOSE It has been reported that corneal endothelial cells (CEC) decrease faster when the tip of the Baerveldt glaucoma implant (BGI) tube is inserted into the anterior chamber than into the vitreous cavity. We investigated whether surgically relocating the tip of the BGI tube from the anterior chamber to the vitreous cavity could reduce CEC loss. PATIENTS AND METHODS This was a single facility retrospective cohort study. The inclusion criteria were the CEC density less than 1500 cells/mm2 and the CEC reduction ratio was greater than 10%/year. The subjects were 11 consecutive patients that could be followed > 12 months after relocation surgery. All patients were undergone vitrectomy, and the tip of tube was inserted into the vitreous cavity from the anterior chamber. We compared the intraocular pressure (IOP), reduction slope of CEC density and annual reduction rate of CEC density before and after relocation surgery. We calculated the annual reduction ratio in comparison with the preoperative CEC density (%/year). RESULTS The mean of period between the Baeveldt with anterior chamber insertion surgery and the relocation surgery was 33.8 ± 15.0 months. The mean of follow-up after relocation surgery was 21.8 ± 9.8 months. The relocation surgery did not significantly change IOP (p = 0.974). The mean preoperative and postoperative IOP were 13.1 ± 4.5 and 13.6 ± 4.3 mmHg. The reduction ratio of the CEC density was 15.4 ± 6.7 (%/year) before relocation surgery and significantly slower at 8.3 ± 6.5 (%/year) after relocation surgery (p = 0.024). Two patients resulted in bullous keratopathy after relocation surgery. CONCLUSIONS Relocating the tip of BGI tube from the anterior chamber to the vitreous cavity could reduce CEC loss.
Collapse
Affiliation(s)
- Yuuki Honda
- Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan
| | - Akio Miyakoshi
- Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan
| | - Naoki Tojo
- Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan.
| | - Atsushi Hayashi
- Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan
| |
Collapse
|
4
|
Lenzhofer M, Motaabbed A, Colvin HP, Hohensinn M, Steiner V, Hitzl W, Runge C, Moussa S, Reitsamer HA. Five-year follow-up of corneal endothelial cell density after transscleral ab interno glaucoma gel stent implantation. Graefes Arch Clin Exp Ophthalmol 2022; 261:1073-1082. [PMID: 36434142 PMCID: PMC10049927 DOI: 10.1007/s00417-022-05898-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/30/2022] [Accepted: 11/03/2022] [Indexed: 11/27/2022] Open
Abstract
Abstract
Purpose
This study investigates the course of the endothelial cell density over a period of 5 years after XEN45 implantation (XEN45µm, Allergan Plc., USA) with or without combined cataract surgery.
Methods
This is a prospective, cross-sectional, monocentric, non-randomized clinical trial with the intention to treat a population of the University Eye Clinic Glaucoma Service Salzburg. One hundred and fifty-five eyes with preoperative central corneal endothelial cell counts were subjected to XEN45 implantation with (combined surgery group) or without (solo surgery group) combined cataract surgery. Endothelial cell density was measured at 3 corneal positions. XEN45 location parameters were determined with anterior segment OCT and gonioscopy.
Results
In the combined surgery group, a significant reduction of central endothelial cell count was found at years 2 and 4 when compared to baseline (p = 0.001 and p = 0.02, n = 86), whereas at years 1, 3, and 5, no change was detected (all p > 0.09). The median reduction of endothelial cell count was − 79 (95% CI: − 183 to − 9) and − 93 (95% CI: − 220 to 23) cells at years 2 and 4, respectively. In the solo surgery group (n = 69), no significant change in endothelial cell counts was detected at any time during the 5-year evaluation period (all p > 0.07). Explorative data analyses revealed that XEN45 location parameters did not significantly influence the course of endothelial cell count over time.
Conclusions
Endothelial cell loss after XEN45 implantation seems to be low. The present data suggest no impact on the position of the implant with regard to central endothelial cell counts in this study.
Collapse
|
5
|
Glaucoma in Patients With Endothelial Keratoplasty. Cornea 2022; 41:1584-1599. [DOI: 10.1097/ico.0000000000003122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 07/09/2022] [Indexed: 11/25/2022]
|
6
|
Yonamine S, Ton L, Rose-Nussbaumer J, Ying GS, Ahmed IIK, Chen TC, Weiner A, Gedde SJ, Han Y. Survey of the American Glaucoma Society Membership on Current Glaucoma Drainage Device Placement and Postoperative Corticosteroid Use. Clin Ophthalmol 2022; 16:2305-2310. [PMID: 35903751 PMCID: PMC9317359 DOI: 10.2147/opth.s369673] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Accepted: 07/05/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To assess practice patterns and opinions of glaucoma specialists regarding glaucoma drainage device tube shunt placement and post-operative anti-inflammatory medication use. We also assess the perceived need for a randomized control trial to compare them. Patients and Methods An online survey was distributed to a group of glaucoma specialists from the American Glaucoma Society via the American Glaucoma Society forum from April to August 2021. Results One hundred and twenty-eight responses were included. Ninety percent placed tubes in the anterior chamber. Sixty-one percent reported that evidence suggested the superiority of sulcus tube placement over the anterior chamber, whereas 34% reported there was not enough evidence to suggest superiority of either in preventing endothelial cell loss. Comparing these techniques for intraocular pressure control, 49% reported evidence suggested sulcus tube placement superiority whereas 46% reported there was not enough evidence. Over 40% of respondents reported that they were either unfamiliar with literature or that there was not enough evidence to support the superiority of difluprednate 0.05% over prednisolone 1% for post-operative use in preventing endothelial cell loss and for intraocular pressure control. Ninety percent and 81% of respondents respectively would benefit from randomized control trials comparing outcomes of anterior chamber vs sulcus tube placement and post-operative corticosteroid usage. Conclusion Most glaucoma specialists surveyed place glaucoma drainage device tube in the anterior chamber over the sulcus. A randomized control trial to determine optimal tube placement and post-operative anti-inflammatory medication use for preventing endothelial cell loss would change current glaucoma drainage device practice patterns.
Collapse
Affiliation(s)
- Sean Yonamine
- Department of Ophthalmology, University of California San Francisco, San Francisco, CA, USA
| | - Lauren Ton
- School of Medicine, University of California San Francisco, San Francisco, CA, USA
| | | | - Gui-Shuang Ying
- Center for Preventive Ophthalmology and Biostatistics, Department of Ophthalmology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Teresa C Chen
- Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA
| | - Asher Weiner
- University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Steven J Gedde
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Ying Han
- Department of Ophthalmology, University of California San Francisco, San Francisco, CA, USA
- Correspondence: Ying Han, Department of Ophthalmology, University of California San Francisco, San Francisco, CA, USA, Tel +1 415 514 6920, Fax +1 415 353 4250, Email
| |
Collapse
|
7
|
Obuchowska I, Konopińska J. Corneal Endothelial Cell Loss in Patients After Minimally Invasive Glaucoma Surgery: Current Perspectives. Clin Ophthalmol 2022; 16:1589-1600. [PMID: 35642179 PMCID: PMC9148582 DOI: 10.2147/opth.s359305] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Accepted: 05/17/2022] [Indexed: 12/14/2022] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) is a rapidly expanding category of surgical glaucoma treatment options that offer a superior safety profile compared with traditional approaches for reducing intraocular pressure. However, MIGS may cause corneal endothelial cell loss; therefore, it has been receiving increasing attention. This systematic review aimed to evaluate and compare the rate and degree of corneal endothelial loss after MIGS. First, this paper presents an overview of the theoretical effectiveness of MIGS, the fundamental aspects regarding the roles of endothelial cells, and the effect of cataract surgery on the quality and count of endothelial cells. Further, we detail the various surgical techniques involved in MIGS, the development of these techniques over the time, and clinical aspects to consider with respect to the endothelial cell count. We discuss in detail the COMPASS-XT study, which was based on data collected over 5 years, reported that withdrawal of the CyPass Micro-Stent (Alcon Laboratories) yielded increased corneal endothelial cell loss. Generally, MIGS procedures are considered safe, with the incidence of complications ranging from 1% to 20% depending on the surgery type; however, there is still need for studies with longer follow-up. Thus, an adequate count of endothelial cells in the central cornea portion is recommended as necessary for candidate patients for MIGS.
Collapse
Affiliation(s)
- Iwona Obuchowska
- Department of Ophthalmology, Medical University of Bialystok, Bialystok, 15-276, Poland
| | - Joanna Konopińska
- Department of Ophthalmology, Medical University of Bialystok, Bialystok, 15-276, Poland
| |
Collapse
|
8
|
Corneal endothelial cell density loss following glaucoma surgery alone or in combination with cataract surgery: A systematic review and meta-analysis. Ophthalmology 2022; 129:841-855. [PMID: 35331751 DOI: 10.1016/j.ophtha.2022.03.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 03/14/2022] [Accepted: 03/15/2022] [Indexed: 11/23/2022] Open
Abstract
TOPIC Corneal endothelial cell density (ECD) loss following glaucoma surgery with or without cataract surgery. CLINICAL RELEVANCE Corneal ECD loss may occur due to intraoperative surgical trauma in glaucoma surgery or postoperatively with chronic endothelial cell trauma or irritation. METHODS Trabeculectomy, glaucoma filtration surgery or microinvasive glaucoma surgery in participants with ocular hypertension, primary and secondary open angle glaucoma, normal tension glaucoma and angle-closure glaucoma were included. Pediatric populations and participants with pre-existing corneal disease were excluded. Laser treatments and peripheral iridotomy were excluded. Electronic databases searched in December 2021 included MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials (CENTRAL), ClinicalTrials.gov and The International Prospective Register of Systematic Reviews (PROSPERO), FDA PMA and FDA 510(k). RESULTS 39 studies were included in quantitative synthesis. 12 months following suprachoroidal MIGS mean ECD loss was 282 cells/mm2 (95% Confidence Interval (CI) 220 to 345; p <0.00001; Chi2 = 0.06; I2 = 0%; 2 studies; very low certainty). Mean ECD loss after Schlemm's canal implantable devices was 338 cells/mm2 (95% CI 185 to 491; p<0.0001; Chi2 = 0.08; I2 = 0%; 2 studies; low certainty) at 12 months. When compared to phacoemulsification alone, Schlemm's canal implants combined with phacoemulsification showed statistically significant mean ECD reduction at 24 months; mean difference of ECD was -19% (95% CI -37% to -2%; p=0.03; Chi2 = 3.04; I2 = 34%; 3 studies; low certainty). Mean ECD loss was 64 cells/mm2 (95% CI 21 to 107; p=0.004; Chi2 = 4.55; I2 = 0%; 6 studies; low certainty) following Schlemm's canal procedures (without implantable devices) at 12 months. At 12 months the mean ECD loss after trabeculectomy was 33 cells/mm2 (95% CI -38 to 105, p=0.36, Chi2 = 1.17; I2 = 0%; moderate certainty). At 12 months mean ECD loss was 121 cells/mm2 (95% CI 53 to 189; p=0.0005; Chi2 = 3.00; I2 = 0%; 5 studies; low certainty) after Express implantation. When compared to control fellow eye, aqueous shunt surgery reduced ECD by 5.75% (95% CI -0.93 to 12.43; p=0.09 Chi2 = 1.32; I2 = 0%; low certainty) and 8.11% ECD loss (95%CI 0.06 to 16.16 p=0.05; Chi2= 1.93; I2=48%) at 12 and 24 months, respectively. CONCLUSIONS Overall there is low certainty evidence to suggest that glaucoma surgery involving long-term implants has a greater extent of ECD loss than glaucoma filtration surgeries without the use of implants. The results of this review support long-term follow-up (beyond 36 months) to assess ECD loss and corneal decompensation following implantation of glaucoma drainage implants.
Collapse
|
9
|
Corneal Endothelial Cell Loss in Glaucoma and Glaucoma Surgery and the Utility of Management with Descemet Membrane Endothelial Keratoplasty (DMEK). J Ophthalmol 2022; 2022:1315299. [PMID: 35637682 PMCID: PMC9148223 DOI: 10.1155/2022/1315299] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 01/10/2022] [Indexed: 01/15/2023] Open
Abstract
The corneal endothelium has a crucial role in maintaining a clear and healthy cornea. Corneal endothelial cell loss occurs naturally with age; however, a diagnosis of glaucoma and surgical intervention for glaucoma can exacerbate a decline in cell number and impairment in morphology. In glaucoma, the mechanisms for this are not well understood and this accelerated cell loss can result in corneal decompensation. Given the high prevalence of glaucoma worldwide, this review aims to explore the abnormalities observed in the corneal endothelium in differing glaucoma phenotypes and glaucoma therapies (medical or surgical including with new generation microinvasive glaucoma surgeries). Descemet membrane endothelial keratoplasty (DMEK) is increasingly being used to manage corneal endothelial failure for glaucoma patients and we aim to review the recent literature evaluating the use of this technique in this clinical scenario.
Collapse
|
10
|
Konopińska J, Saeed E, Lisowski Ł, Gołaszewska K, Kraśnicki P, Dmuchowska DA, Obuchowska I. Evaluation of the Effect of the First Generation iStent on Corneal Endothelial Cell Loss-A Match Case-Control Study. J Clin Med 2021; 10:jcm10194410. [PMID: 34640426 PMCID: PMC8509432 DOI: 10.3390/jcm10194410] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 09/16/2021] [Accepted: 09/24/2021] [Indexed: 12/31/2022] Open
Abstract
Glaucoma is the leading cause of irreversible blindness worldwide. The only proven factor in slowing the progression of glaucomatous neuropathy is lower intraocular pressure (IOP), which can be achieved with pharmacology, laser therapy, or surgery. However, these treatments are associated with various adverse effects, including corneal endothelial cell loss (CECL). In recent years, several novel surgeries for reducing the IOP, collectively referred to as minimally invasive glaucoma surgery (MIGS), have been developed, one of which is the iStent. However, the long-term effects of such surgeries remain unknown. We compared a group of patients with open-angle glaucoma and cataract who underwent phacoemulsification alone with a group of patients with similar demographic and clinical characteristics who underwent simultaneous phacoemulsification and iStent implantation. Overall, 26 eyes of 22 subjects who underwent a combined phacoemulsification-iStent procedure and 26 eyes of 24 subjects who underwent cataract surgery were included. Before surgery, endothelial cells accounted to 2228.65 ± 474.99 in iStent group and 2253.96 ± 404.76 in the control group (p = 0.836). After surgery, their number declined to 1389.77 ± 433.26 and 1475.31 ± 556.45, respectively (p = 0.509). There was no statistically significant difference in CECL between the two groups 18–24 months after surgery, despite increased manipulation in the anterior chamber and the presence of an implant in the trabecular meshwork in those with an iStent implant. Thus, iStent bypass implantation is a safe treatment in terms of CECL for mild-to-moderate open-angle glaucoma.
Collapse
|
11
|
Anterior Chamber Versus Ciliary Sulcus Ahmed Glaucoma Valve Tube Placement: Longitudinal Evaluation of Corneal Endothelial Cell Profiles. J Glaucoma 2021; 30:170-174. [PMID: 33955946 DOI: 10.1097/ijg.0000000000001700] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 09/22/2020] [Indexed: 11/26/2022]
Abstract
PRCIS An Ahmed glaucoma valve (AGV) tube in the ciliary sulcus (CS) is safer for the endothelium. At 4 years of follow-up, there was a significant decrease in endothelial cell count only with anterior chamber (AC) placement. PURPOSE Corneal endothelium (CE) damage is one of the most feared long-term complications that can result from glaucoma drainage devices. Nonetheless, there is a lack of studies evaluating longitudinal changes in CE cells. This study aims to compare CE changes after AGV implantation in eyes with AC or CS tube placement. MATERIALS AND METHODS This was a retrospective, nonrandomized, longitudinal study of pseudophakic eyes with open-angle glaucoma and medically uncontrolled intraocular pressure that received an AGV. Eyes with additional glaucoma surgeries performed during follow-up were excluded. The main outcome measure was endothelial cell density (ECD), which was evaluated 1 year±2 months and 4 years±2 months postoperatively. The average endothelial cell size (AS) and the distance from the tube tip to the cornea were also evaluated. RESULTS Twenty-six eyes from 26 patients, with a mean age of 73±10 years, were included. The tube was placed in the AC in 15 eyes and in the CS in 11 eyes. The eyes with tube placement in the AC showed a significant AS increase (P=0.007) and ECD decrease (P=0.034), whereas eyes with tube placement in the CS had no significant AS (P=0.575) or ECD (P=0.445) change. In the eyes with tube placement in the AC, there was no correlation between DTC and ECD (P=0.260) or AS (P=0.428) changes. CONCLUSIONS Tube placement in the AC seems to lead to significant CE cell loss over time, compared with tube placement in the CS.
Collapse
|
12
|
Realini T, Gupta PK, Radcliffe NM, Garg S, Wiley WF, Yeu E, Berdahl JP, Kahook MY. The Effects of Glaucoma and Glaucoma Therapies on Corneal Endothelial Cell Density. J Glaucoma 2021; 30:209-218. [PMID: 33105305 DOI: 10.1097/ijg.0000000000001722] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 10/05/2020] [Indexed: 12/19/2022]
Abstract
A healthy corneal endothelium is required for corneal clarity. Both the glaucoma disease state and its various forms of treatment can have adverse effects on the corneal endothelium. Both the presence of glaucoma and the magnitude of intraocular pressure elevation are related to endothelial cell loss (ECL). Topical medical therapy, laser procedures, and both traditional surgeries-trabeculectomy and tube-shunts-and newer minimally invasive glaucoma surgeries have variable effects on ECL. This review will summarize the reported effects of glaucoma and its treatment on ECL. Concerns for corneal endothelial cell health should be part of the decision-making process when planning glaucoma therapy for lowering intraocular pressure, with added caution in case of planned device implantation in eyes with preexisting ECL and low endothelial cell density at high risk for corneal endothelial decompensation.
Collapse
Affiliation(s)
- Tony Realini
- Department of Ophthalmology and Visual Sciences, West Virginia University Eye Institute, Morgantown, WV
| | - Preeya K Gupta
- Department of Ophthalmology, Duke University, Durham, NC
| | - Nathan M Radcliffe
- Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, NY
| | - Sumit Garg
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, CA
| | | | | | | | - Malik Y Kahook
- Sue Anschutz-Rodgers Eye Center, University of Colorado School of Medicine, Aurora, CO
| |
Collapse
|
13
|
Sinha S, Ganjei AY, Ustaoglu M, Syed ZA, Lee D, Myers JS, Fudemberg SJ, Razeghinejad R. Effect of shunt type on rates of tube-cornea touch and corneal decompensation after tube shunt surgery in uveitic glaucoma. Graefes Arch Clin Exp Ophthalmol 2021; 259:1587-1595. [PMID: 33515315 DOI: 10.1007/s00417-021-05095-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Revised: 01/14/2021] [Accepted: 01/22/2021] [Indexed: 12/17/2022] Open
Abstract
PURPOSE To evaluate the effect of tube shunt type [Ahmed (AGV) versus Baerveldt (BGI)] on the frequency of tube-cornea touch and corneal decompensation after tube shunt surgery. METHODS This retrospective comparative study included 145 eyes of 130 patients with uveitic glaucoma who underwent AGV (75 eyes) or BGI (70 eyes) implantations. Electronic medical records were reviewed to document demographic factors, intraocular pressure (IOP) reduction, frequency of tube-cornea touch, corneal decompensation, and need for subsequent corneal transplantation. RESULTS The mean follow-up was 27.7±3.3 months for AGV and 32.8±3.8 months for BGI (p=0.30). Tube-cornea touch was observed in 5 eyes after BGI and 1 eye in the AGV group (p=0.08). The BGI group reported a significantly higher rate of corneal decompensation (9 versus 0; p=0.001) and transplantation (6 versus 0; p=0.01) compared to the AGV group. Previous trabeculectomy was a significant risk factor for corneal complications in eyes undergoing BGI implantation (odds ratio [OR]= 8.17, 95% confidence interval [CI]=1.78-37.45, p=0.007). CONCLUSION Similar rates of tube-cornea touch were observed in both shunt types; BGI shunts were associated with a greater incidence of corneal complications and transplantation as compared to AGV in this retrospective series of uveitic glaucoma cases.
Collapse
Affiliation(s)
- Sapna Sinha
- Wills Eye Hospital, Glaucoma Research Center, 840 Walnut Street, Suite 1140, Philadelphia, PA, 19107, USA.
| | - Allen Y Ganjei
- Drexel University College of Medicine, Philadelphia, PA, USA
| | - Melih Ustaoglu
- Wills Eye Hospital, Glaucoma Research Center, 840 Walnut Street, Suite 1140, Philadelphia, PA, 19107, USA
| | - Zeba A Syed
- Wills Eye Hospital, Cornea Service, Philadelphia, PA, USA
| | - Daniel Lee
- Wills Eye Hospital, Glaucoma Research Center, 840 Walnut Street, Suite 1140, Philadelphia, PA, 19107, USA
| | - Jonathan S Myers
- Wills Eye Hospital, Glaucoma Research Center, 840 Walnut Street, Suite 1140, Philadelphia, PA, 19107, USA
| | - Scott J Fudemberg
- Wills Eye Hospital, Glaucoma Research Center, 840 Walnut Street, Suite 1140, Philadelphia, PA, 19107, USA
| | - Reza Razeghinejad
- Wills Eye Hospital, Glaucoma Research Center, 840 Walnut Street, Suite 1140, Philadelphia, PA, 19107, USA
| |
Collapse
|
14
|
Mundorf T, Mah F, Sheng H, Heah T. Effects of Netarsudil on the Corneal Endothelium. ACTA ACUST UNITED AC 2020; 3:421-425. [DOI: 10.1016/j.ogla.2020.04.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 02/13/2020] [Accepted: 04/22/2020] [Indexed: 12/17/2022]
|
15
|
Gillmann K, Bravetti GE, Rao HL, Mermoud A, Mansouri K. Impact of Phacoemulsification Combined with XEN Gel Stent Implantation on Corneal Endothelial Cell Density: 2-Year Results. J Glaucoma 2020; 29:155-160. [PMID: 32108690 DOI: 10.1097/ijg.0000000000001430] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
INTRODUCTION Corneal integrity has long been a preoccupation of glaucoma surgeons considering glaucoma drainage device surgery or antimetabolite-enhanced trabeculectomy. Despite having demonstrated a good safety profile and significant intraocular pressure-lowering capacities, the impact of XEN gel stents on endothelial density was never specifically investigated. The purpose of this study is to assess the effect of XEN gel stents on central endothelial cell density (ECD) over 24 months. To achieve this, we compared the effect on ECD of combined XEN surgery with that of a standard phacoemulsification procedure. METHODS This was an investigator-initiated, retrospective study, conducted at a single tertiary glaucoma center. Patients with primary or secondary open-angle glaucoma who underwent XEN implantation combined with phacoemulsification between January 2015 and June 2016 were retrospectively enrolled. Patients who had undergone standalone phacoemulsification over the same period of time were enrolled to form the control group of this comparative study. The primary outcome measure was the ECD. Patients who had undergone standalone XEN implantation and patients for whom both a baseline and 24-month ECD could not be obtained were excluded from the analysis. Percentages of ECD reductions were calculated for each studied eye, and the mean of ECD reductions was calculated for each group as well as for subgroups. RESULTS Thirty-two eyes of 23 patients (mean age=76.0±7.9 y, 60% female) underwent standalone phacoemulsification (n=15) or combined XEN surgery (n=17) and had an ECD both at baseline and 24-month postoperatively. Mean baseline ECDs were 2568±491 versus 2379±335 cells/mm, respectively (P=0.21). In the combined XEN surgery group, 58.8% of eyes (n=10) required at least 1 mitomycin C (MMC)-enhanced needling revision to maintain their target intraocular pressure. In the standalone phacoemulsification group, ECD decreased by a mean 14.5%, from 2567.7±491.2 to 2196.1±591.9 cell/mm (P=0.072). In the combined XEN surgery group, ECD decreased by a mean 14.3%, from 2378.8±334.7 to 2039.6±451.1 cell/mm (P=0.018). The difference in percentage reduction of ECD between the 2 groups was not statistically significant (P=0.226). Within the combined XEN surgery group, the ECD decreased by a mean of 15.4% in patients who did not undergo needling revisions and by 13.1% in patients who underwent the MMC-augmented procedure (P=0.485). In the 3 patients who underwent >1 needling revision, a 21.3% reduction in ECD was observed, but the difference was not statistically significant (P=0.653). Neither the time of the first needling (P=0.452), the patients' age (P=0.285), or sex (P=0.308) was statistically associated with ECD loss. DISCUSSION The present study demonstrated that the XEN gel implant combined with phacoemulsification produces 24-month ECD loss of a similar magnitude to that observed following standalone phacoemulsification. MMC-augmented needling revisions do not appear to have an impact on ECD.
Collapse
Affiliation(s)
- Kevin Gillmann
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio Network, Lausanne, Switzerland
| | - Giorgio E Bravetti
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio Network, Lausanne, Switzerland
| | - Harsha L Rao
- Narayana Nethralaya, Bangalore, Karnataka, India
| | - André Mermoud
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio Network, Lausanne, Switzerland
| | - Kaweh Mansouri
- Glaucoma Research Center, Montchoisi Clinic, Swiss Visio Network, Lausanne, Switzerland.,Department of Ophthalmology, University of Colorado School of Medicine, Denver, CO
| |
Collapse
|
16
|
Corneal Parameters after Tube-Shunt Implantation through the Ciliary Sulcus. Ophthalmol Glaucoma 2020; 4:32-41. [PMID: 32739403 DOI: 10.1016/j.ogla.2020.07.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 07/23/2020] [Accepted: 07/23/2020] [Indexed: 01/15/2023]
Abstract
PURPOSE To monitor bilateral corneal parameters after unilateral Baerveldt 350 tube-shunt implantation (Advanced Medical Optics, Santa Ana, CA) through the ciliary sulcus. DESIGN Retrospective, interventional case series. PARTICIPANTS Patients from 1 private glaucoma practice with severe uncontrolled glaucoma treated with sulcus tube-shunt implantation in 1 pseudophakic eye. METHODS Specular microscopy data were collected before and after unilateral sulcus tube-shunt implantation from the surgical and the glaucomatous fellow eyes. MAIN OUTCOME MEASURES Central corneal endothelial cell density (CECD), coefficient of variation (CV), percent of hexagonal cells, central corneal thickness (CCT), intraocular pressure (IOP), IOP-lowering medications, visual acuity, and complications. RESULTS Forty-six patients (mean age, 69.9 years; standard deviation [SD], 4.6 years; range, 20-88 years; male gender, 41.3%) were identified. After surgery, IOP and the number of IOP-lowering medications decreased significantly by 42.3% (P < 0.0001) and 32.1% (P < 0.0001), respectively, in the surgical eye group. Preoperative CECD measured 1807 cells/mm2 (SD, 172 cells/mm2) and 1825 cells/mm2 (SD, 172 cells/mm2) in the surgical and fellow eyes, respectively (P = 0.92), and compared with baseline, it decreased by 8.6% (P = 0.17) and 3.1% (P = 0.65), respectively, by 24 months. Preoperative CV, percent of hexagonal cells, and CCT were similar in both groups and remained stable. All corneal parameters remained unchanged in a subgroup of 15 patients with low preoperative CECD (1273 cells/mm2; SD, 99 cells/mm2). Best-corrected visual acuity remained stable in both groups. Hyphema occurred in 23.9% of the surgical eyes and resolved with no intervention. We found no sight-threatening complications or corneal failures during follow-up. CONCLUSIONS Tube-shunt implantation through the ciliary sulcus in pseudophakic eyes appears relatively safe to the corneal endothelium, demonstrating a small and nonsignificant decline in central CECD compared with baseline and with glaucomatous fellow eyes. No significant disruption to corneal endothelial cell morphologic features, increased corneal thickness, or corneal failures were found during the 24-month follow-up period. A prospective head-to-head comparison to assess the effects of the various methods of tube-shunt implantation on the corneal endothelium is needed.
Collapse
|
17
|
Zhang Q, Liu Y, Thanapaisal S, Oatts J, Luo Y, Ying GS, Wang J, McLeod SD, Gedde SJ, Han Y. The Effect of Tube Location on Corneal Endothelial Cells in Patients with Ahmed Glaucoma Valve. Ophthalmology 2020; 128:218-226. [PMID: 32603727 DOI: 10.1016/j.ophtha.2020.06.050] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 06/05/2020] [Accepted: 06/22/2020] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To compare the effects of the Ahmed glaucoma valve (AGV; New World Medical, Rancho Cucamonga, CA) with sulcus versus anterior chamber (AC) tube placement on the corneal endothelial density and morphology over time. DESIGN Nonrandomized, interventional study. PARTICIPANTS This study included 106 eyes from 101 pseudophakic patients who had the AGV tube placed in the AC (acAGV) and 105 eyes from 94 pseudophakic patients who had the AGV tube placed in the ciliary sulcus (sAGV). METHODS All patients underwent preoperative specular microscopy, which was repeated postoperatively in 2019. The patients' demographic information, glaucoma diagnoses, and basic ocular information were obtained on chart review. Anterior segment OCT was conducted for patients who underwent sAGV to evaluate the sulcus tube position. Gonioscopy was performed to document peripheral anterior synechiae (PAS). Linear mixed-effects models were used to compare the different ocular and endothelial measurements between the 2 groups and to identify risk factors for endothelial cell density (ECD) loss over time. MAIN OUTCOME MEASURES Monthly change in corneal endothelial measurements, including ECD and coefficient of variation (CV), calculated as the difference between preoperative and postoperative measurements divided by the number of months from the time of surgery to postoperative specular microscopy. RESULTS The acAGV and sAGV groups were comparable in all baseline characteristics except that the acAGV group had longer follow-up (37.6 vs. 20.1 months, respectively, P < 0.001). Mean monthly loss in central ECD was significantly more in the acAGV group (mean ± standard deviation: 29.3±29.7 cells/mm2) than in the sAGV group (15.3±20.7 cells/mm2, P < 0.0001). Mean monthly change in CV was similar between the 2 groups (P = 0.28). Multivariate analyses revealed that younger age and tube location in the AC were associated with faster central ECD loss (P = 0.02, P < 0.0001, respectively). For patients with sAGV, while PAS was associated with faster central ECD loss (P = 0.002), a more forward tube position tenting the iris was not (P > 0.05). CONCLUSIONS Compared with anterior segment placement, ciliary sulcus tube implantation may be a preferred surgery approach to reduce endothelial cell loss in pseudophakic patients.
Collapse
Affiliation(s)
- Qi Zhang
- Department of Ophthalmology, University of California San Francisco, San Francisco, California; The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology and Chongqing Eye Institute, Chongqing, China
| | - Yingna Liu
- Department of Ophthalmology, University of California San Francisco, San Francisco, California
| | - Sukhumal Thanapaisal
- Department of Ophthalmology, University of California San Francisco, San Francisco, California; Department of Ophthalmology, Khon Kaen University, Khon Kaen, Thailand
| | - Julius Oatts
- Department of Ophthalmology, University of California San Francisco, San Francisco, California
| | - Yetao Luo
- Department of Clinical Epidemiology and Biostatistics, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Gui-Shuang Ying
- Center for Preventive Ophthalmology and Biostatistics, University of Pennsylvania, Perelman School of Medicine, Philadelphia, Pennsylvania
| | - Junming Wang
- Department of Ophthalmology, Tonji Hospital, Tongji Medial College, Huazhong University of Science and Technology, Wuhan, China
| | - Stephen D McLeod
- Department of Ophthalmology, University of California San Francisco, San Francisco, California
| | - Steven J Gedde
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| | - Ying Han
- Department of Ophthalmology, University of California San Francisco, San Francisco, California.
| |
Collapse
|
18
|
The Impact of Glaucoma Drainage Devices on the Cornea. CURRENT OPHTHALMOLOGY REPORTS 2020. [DOI: 10.1007/s40135-020-00234-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
19
|
Olgun A, Duzgun E, Yildiz AM, Atmaca F, Yildiz AA, Sendul SY. XEN Gel Stent versus trabeculectomy: Short-term effects on corneal endothelial cells. Eur J Ophthalmol 2020; 31:346-353. [PMID: 32452237 DOI: 10.1177/1120672120924339] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To compare the short-term changes in corneal endothelial cells after trabeculectomy or XEN Gel Stent implantation. DESIGN Prospective, interventional, comparative study. METHODS Changes in corneal endothelium in patients that underwent XEN Gel Stent implantation or trabeculectomy were prospectively evaluated. Eighty eyes of 62 diagnosed with open-angle glaucoma were divided into two the trabeculectomy and XEN Gel Stent groups. Corneal specular microscopy was performed at the central cornea using a noncontact specular microscope preoperatively and 3 months after surgery. RESULTS The baseline mean corneal endothelial cell density in the trabeculectomy group was 2390.3 ± 324.8 cells/mm2, and this was significantly reduced to 2148 ± 352.5 cells/mm2 3 months after surgery, representing a cell loss of 10.0% (p < 0.001). The baseline mean corneal endothelial cell density in the XEN Gel Stent group was 2156.2 ±559.7 cells/mm2, and this was significantly reduced to 2098.4 ± 556.2 cells/mm2 3 months after surgery, representing a cell loss of 2.1% (p = 0.002). The corneal endothelial cell density change rate of the trabeculectomy group (-10.0% ± 9.7%) was statistically higher than the XEN Gel Stent group (-2.1% ± 13.8%) (p = 0.002). A statistically significant difference was observed in the trabeculectomy group between the baseline and postoperative values in the coefficient of variation (p = 0.029). CONCLUSION Trabeculectomy caused more endothelial cell damage than XEN Gel Stent implantation in the short-term follow-up period. The XEN Gel Stent may be the treatment of choice in patients with a significantly low preoperative corneal endothelial cell density.
Collapse
Affiliation(s)
- Ali Olgun
- Department of Ophthalmology, Sisli Hamidiye Etfal Training and Research Hospital, University of Health Sciences, Istanbul, Turkey
| | - Eyup Duzgun
- Department of Ophthalmology, Sisli Hamidiye Etfal Training and Research Hospital, University of Health Sciences, Istanbul, Turkey
| | | | | | | | - S Yekta Sendul
- Department of Ophthalmology, Sisli Hamidiye Etfal Training and Research Hospital, University of Health Sciences, Istanbul, Turkey
| |
Collapse
|
20
|
Corneal Endothelial Cell Loss and Morphometric Changes 5 Years after Phacoemulsification with or without CyPass Micro-Stent. Am J Ophthalmol 2019; 208:211-218. [PMID: 31377278 DOI: 10.1016/j.ajo.2019.07.016] [Citation(s) in RCA: 76] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 07/01/2019] [Accepted: 07/20/2019] [Indexed: 11/23/2022]
Abstract
PURPOSE To characterize long-term changes in corneal endothelial cells after phacoemulsification with or without supraciliary Micro-Stent (Alcon) implantation in eyes with open-angle glaucoma (OAG) and visually significant cataract. DESIGN Three-year safety extension of a 2-year randomized clinical trial. METHODS Patients from the multicenter Study of an Implantable Device for Lowering Intraocular Pressure in Glaucoma Patients Undergoing Cataract Surgery (COMPASS) trial who underwent Micro-Stent implantation plus phacoemulsification (n = 282) or phacoemulsification alone (n = 67) were analyzed post hoc. Specular microscopy was used to assess endothelial cell loss (ECL), including changes from baseline in endothelial cell density (ECD), coefficient of variation, and percentage of hexagonal cells. RESULTS Preoperative ECDs in the microstent group (2,432.6 cells/mm2 [95% confidence interval [CI], 2,382.8-2,482.4 cells/mm2]) were similar to those in the control group (2,434.5 cells/mm2 [95% CI, 2,356.5-2,512.4 cells/mm2]) groups. ECL at months 48 and 60 was greater in the Micro-Stent group than in the control group. At month 60, the mean percent of changes in ECD was -20.4% (95% CI, -23.5% to -17.5%) in the Micro-Stent group and -10.1% (95% CI, -13.9% to -6.3%) in the control group. No statistically significant between-group changes from baseline in cellular morphology were observed. Nine adverse events were possibly related to ECL, including 3 eyes with transient focal corneal edema and 4 eyes that required Micro-Stent trimming due to protrusion. CONCLUSIONS In eyes with OAG, ECL after phacoemulsification is acute and stabilizes after 3 months, whereas ECL after phacoemulsification plus Micro-Stent implantation proceeds for at least 5 years. Clinical findings associated with ECL in these eyes were uncommon (3.3% of implanted eyes), suggesting that ECL is generally a subclinical phenomenon.
Collapse
|
21
|
Bhartiya S, Shaarawy T. The Quest for the Holy Grail of Glaucoma Surgery: Does Cypass Herald the End? J Curr Glaucoma Pract 2019; 12:99-101. [PMID: 31354200 PMCID: PMC6647821 DOI: 10.5005/jp-journals-10028-1252] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
How to cite this article: Bhartiya S, Shaarawy T. The Quest for the Holy Grail of Glaucoma Surgery: Does Cypass Herald the End?. J Curr Glaucoma Pract 2018;12(3):99-101.
Collapse
Affiliation(s)
- Shibal Bhartiya
- Glaucoma Services, Fortis Memorial Hospital, Gurugram, Haryana, India
| | - Tarek Shaarawy
- University of Geneva, Glaucoma Sector, University of Geneva Hospitals, Switzerland
| |
Collapse
|
22
|
Fully convolutional architecture vs sliding-window CNN for corneal endothelium cell segmentation. BMC Biomed Eng 2019; 1:4. [PMID: 32903308 PMCID: PMC7412678 DOI: 10.1186/s42490-019-0003-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Accepted: 01/03/2019] [Indexed: 11/23/2022] Open
Abstract
Background Corneal endothelium (CE) images provide valuable clinical information regarding the health state of the cornea. Computation of the clinical morphometric parameters requires the segmentation of endothelial cell images. Current techniques to image the endothelium in vivo deliver low quality images, which makes automatic segmentation a complicated task. Here, we present two convolutional neural networks (CNN) to segment CE images: a global fully convolutional approach based on U-net, and a local sliding-window network (SW-net). We propose to use probabilistic labels instead of binary, we evaluate a preprocessing method to enhance the contrast of images, and we introduce a postprocessing method based on Fourier analysis and watershed to convert the CNN output images into the final cell segmentation. Both methods are applied to 50 images acquired with an SP-1P Topcon specular microscope. Estimates are compared against a manual delineation made by a trained observer. Results U-net (AUC=0.9938) yields slightly sharper, clearer images than SW-net (AUC=0.9921). After postprocessing, U-net obtains a DICE=0.981 and a MHD=0.22 (modified Hausdorff distance), whereas SW-net yields a DICE=0.978 and a MHD=0.30. U-net generates a wrong cell segmentation in only 0.48% of the cells, versus 0.92% for the SW-net. U-net achieves statistically significant better precision and accuracy than both, Topcon and SW-net, for the estimates of three clinical parameters: cell density (ECD), polymegethism (CV), and pleomorphism (HEX). The mean relative error in U-net for the parameters is 0.4% in ECD, 2.8% in CV, and 1.3% in HEX. The computation time to segment an image and estimate the parameters is barely a few seconds. Conclusions Both methods presented here provide a statistically significant improvement over the state of the art. U-net has reached the smallest error rate. We suggest a segmentation refinement based on our previous work to further improve the performance.
Collapse
|
23
|
Bhartiya S, Shaarawy T. The Quest for the Holy Grail of Glaucoma Surgery: Does Cypass Herald the End? J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10078-1231] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
24
|
Janson BJ, Alward WL, Kwon YH, Bettis DI, Fingert JH, Provencher LM, Goins KM, Wagoner MD, Greiner MA. Glaucoma-associated corneal endothelial cell damage: A review. Surv Ophthalmol 2017; 63:500-506. [PMID: 29146208 DOI: 10.1016/j.survophthal.2017.11.002] [Citation(s) in RCA: 69] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2017] [Revised: 11/08/2017] [Accepted: 11/08/2017] [Indexed: 11/15/2022]
Abstract
The corneal endothelium is critical in maintaining a healthy and clear cornea. Corneal endothelial cells have a significant reserve function, but preservation of these cells is paramount as they have limited regenerative capacity. Glaucoma is a prevalent disease, and damage to the corneal endothelium may be caused by the disease process itself as well as by its treatment. The mechanisms involved in glaucoma-associated damage to the corneal endothelium need further investigation. Understanding how glaucoma and glaucoma surgery impact the endothelium is important for protecting corneal clarity and visual acuity in all glaucoma patients, including those undergoing corneal transplant. We will discuss a range of identified factors that may impact corneal endothelial cell health in glaucoma, including intraocular pressure, glaucoma medications, surgical glaucoma management, mechanical forces, and alterations in the aqueous environment.
Collapse
Affiliation(s)
- Ben J Janson
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - Wallace L Alward
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - Young H Kwon
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - Daniel I Bettis
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - John H Fingert
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - Lorraine M Provencher
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - Kenneth M Goins
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - Michael D Wagoner
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA
| | - Mark A Greiner
- Department of Ophthalmology and Visual Sciences, University of Iowa Carver College of Medicine, Iowa City, Iowa, USA.
| |
Collapse
|
25
|
Implantation of a second glaucoma drainage device. Graefes Arch Clin Exp Ophthalmol 2017; 255:1019-1025. [DOI: 10.1007/s00417-017-3596-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 01/08/2017] [Accepted: 01/16/2017] [Indexed: 10/20/2022] Open
|
26
|
Kim MS, Kim KN, Kim CS. Changes in Corneal Endothelial Cell after Ahmed Glaucoma Valve Implantation and Trabeculectomy: 1-Year Follow-up. KOREAN JOURNAL OF OPHTHALMOLOGY 2016; 30:416-425. [PMID: 27980360 PMCID: PMC5156615 DOI: 10.3341/kjo.2016.30.6.416] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Accepted: 04/20/2016] [Indexed: 12/13/2022] Open
Abstract
Purpose To compare changes in corneal endothelial cell density (CECD) after Ahmed glaucoma valve (AGV) implantation and trabeculectomy. Methods Changes in corneal endothelium in patients that underwent AGV implantation or trabeculectomy were prospectively evaluated. Corneal specular microscopy was performed at the central cornea using a non-contact specular microscope before surgery and 6 months and 12 months after surgery. The CECD, hexagonality of the endothelial cells, and the coefficient of variation of the cell areas were compared between the two groups. Results Forty eyes of 40 patients with AGV implantation and 28 eyes of 28 patients with trabeculectomy were studied. Intraocular pressure in the AGV implantation group was significantly higher than that in the trabeculectomy group (p < 0.001), but there was no significant difference in other clinical variables between the two groups. In the AGV implantation group, the mean CECD significantly decreased by 9.4% at 6 months and 12.3% at 12 months compared with baseline values (both, p < 0.001), while it decreased by 1.9% at 6 months and 3.2% at 12 months in the trabeculectomy group (p = 0.027 and p = 0.015, respectively). The changes at 6 months and 12 months in the AGV implantation group were significantly higher than those in the trabeculectomy group (p = 0.030 and p = 0.027, respectively). In the AGV implantation group, there was a significant decrease in the CECD between baseline and 6 months and between 6 months and 12 months (p < 0.001 and p = 0.005, respectively). However, in the trabeculectomy group, a significant decrease was observed only between baseline and 6 months (p = 0.027). Conclusions Both the AGV implantation group and the trabeculectomy group showed statistically significant decreases in the CECD 1 year after surgery. The decrease in CECD in the AVG implantation group was greater and persisted longer than that in the trabeculectomy group.
Collapse
Affiliation(s)
- Min Su Kim
- Department of Ophthalmology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea
| | - Kyoung Nam Kim
- Department of Ophthalmology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea
| | - Chang-Sik Kim
- Department of Ophthalmology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Korea
| |
Collapse
|
27
|
|
28
|
A Comparison of Endothelial Cell Loss in Combined Cataract and MIGS (Hydrus) Procedure to Phacoemulsification Alone: 6-Month Results. J Ophthalmol 2015; 2015:769289. [PMID: 26664740 PMCID: PMC4664806 DOI: 10.1155/2015/769289] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 10/20/2015] [Indexed: 11/17/2022] Open
Abstract
Purpose. To compare the corneal endothelial cell loss after phacoemulsification, alone or combined with microinvasive glaucoma surgery (MIGS), in nonglaucomatous versus primary open angle glaucoma (POAG) eyes affected by age-related cataract. Methods. 62 eyes of 62 patients were divided into group 1 (n = 25, affected by age-related cataract) and group 2 (n = 37, affected by age-related cataract and POAG). All patients underwent cataract surgery. Group 2 was divided into subgroups A (n = 19, cataract surgery alone) and B (n = 18, cataract surgery and MIGS). Prior to and 6 months after surgery the patients' endothelium was studied. Main outcomes were CD (cell density), SD (standard deviation), CV (coefficient of variation), and 6A (hexagonality coefficient) variations after surgeries. Results. There were no significant differences among the groups concerning preoperative endothelial parameters. The differences in CD before and after surgery were significant in all groups: 9.1% in group 1, 17.24% in group 2A, and 11.71% in group 2B. All endothelial parameters did not significantly change after surgery. Conclusions. Phacoemulsification determined a loss of endothelial cells in all groups. After surgery the change in endothelial parameters after MIGS was comparable to the ones of patients who underwent cataract surgery alone.
Collapse
|
29
|
Kim KN, Lee SB, Lee YH, Lee JJ, Lim HB, Kim CS. Changes in corneal endothelial cell density and the cumulative risk of corneal decompensation after Ahmed glaucoma valve implantation. Br J Ophthalmol 2015; 100:933-938. [PMID: 26508781 DOI: 10.1136/bjophthalmol-2015-306894] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2015] [Revised: 08/25/2015] [Accepted: 10/03/2015] [Indexed: 12/11/2022]
Abstract
AIMS To evaluate changes in the corneal endothelial cell density (ECD) and corneal decompensation following Ahmed glaucoma valve (AGV) implantation. METHODS This study was retrospective and observational case series. Patients with refractory glaucoma who underwent AGV implantation and were followed >5 years were consecutively enrolled. We reviewed the medical records, including the results of central corneal specular microscopy. Of the 127 enrolled patients, the annual change in ECD (%) was determined using linear regression for 72 eyes evaluated at least four times using serial specular microscopic examination and compared with 31 control eyes (fellow glaucomatous eyes under medical treatment). The main outcome measures were cumulative risk of corneal decompensation and differences in the ECD loss rates between subjects and controls. RESULTS The mean follow-up after AGV implantation was 43.1 months. There were no cases of postoperative tube-corneal touch. The cumulative risk of corneal decompensation was 3.3%, 5 years after AGV implantation. There was a more rapid loss of ECD in the 72 subject eyes compared with the 31 controls (-7.0% and -0.1%/year, respectively; p<0.001). However, the rate of loss decreased over time and statistical significance compared with control eyes disappeared after 2 years postoperatively: -10.7% from baseline to 1 year (p<0.01), -7.0% from 1 year to 2 years (p=0.037), -4.2% from 2 years to 3 years (p=0.230) and -2.7% from 3 years to the final follow-up (p=0.111). CONCLUSIONS In case of uncomplicated AGV implantation, the cumulative risk of corneal decompensation was 3.3%, 5 years after the operation. The ECD loss was statistically greater in eyes with AGV than in control eyes without AGV, but the difference was significant only up to 2 years post surgery.
Collapse
Affiliation(s)
- Kyoung Nam Kim
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea
| | - Sung Bok Lee
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea.,Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Korea
| | - Yeon Hee Lee
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea.,Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Korea
| | - Jong Joo Lee
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea
| | - Hyung Bin Lim
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea
| | - Chang-Sik Kim
- Department of Ophthalmology, Chungnam National University Hospital, Daejeon, Korea.,Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Korea
| |
Collapse
|
30
|
Effect of Glaucoma Tube Shunt Parameters on Cornea Endothelial Cells in Patients With Ahmed Valve Implants. Cornea 2015; 34:37-41. [DOI: 10.1097/ico.0000000000000301] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
31
|
Multivariate biophysical markers predictive of mesenchymal stromal cell multipotency. Proc Natl Acad Sci U S A 2014; 111:E4409-18. [PMID: 25298531 DOI: 10.1073/pnas.1402306111] [Citation(s) in RCA: 122] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
The capacity to produce therapeutically relevant quantities of multipotent mesenchymal stromal cells (MSCs) via in vitro culture is a common prerequisite for stem cell-based therapies. Although culture expanded MSCs are widely studied and considered for therapeutic applications, it has remained challenging to identify a unique set of characteristics that enables robust identification and isolation of the multipotent stem cells. New means to describe and separate this rare cell type and its downstream progenitor cells within heterogeneous cell populations will contribute significantly to basic biological understanding and can potentially improve efficacy of stem and progenitor cell-based therapies. Here, we use multivariate biophysical analysis of culture-expanded, bone marrow-derived MSCs, correlating these quantitative measures with biomolecular markers and in vitro and in vivo functionality. We find that, although no single biophysical property robustly predicts stem cell multipotency, there exists a unique and minimal set of three biophysical markers that together are predictive of multipotent subpopulations, in vitro and in vivo. Subpopulations of culture-expanded stromal cells from both adult and fetal bone marrow that exhibit sufficiently small cell diameter, low cell stiffness, and high nuclear membrane fluctuations are highly clonogenic and also exhibit gene, protein, and functional signatures of multipotency. Further, we show that high-throughput inertial microfluidics enables efficient sorting of committed osteoprogenitor cells, as distinct from these mesenchymal stem cells, in adult bone marrow. Together, these results demonstrate novel methods and markers of stemness that facilitate physical isolation, study, and therapeutic use of culture-expanded, stromal cell subpopulations.
Collapse
|
32
|
Baerveldt drainage tube motility in the anterior chamber. Eur J Ophthalmol 2013; 24:364-70. [PMID: 24170514 DOI: 10.5301/ejo.5000379] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/22/2013] [Indexed: 11/20/2022]
Abstract
PURPOSE To investigate the stability in position of the Baerveldt glaucoma drainage tube over time and to study movement of the drainage tube in the anterior chamber (AC) under varying light conditions. METHODS This prospective study included 70 eyes with implantation of a Baerveldt glaucoma drainage tube in the anterior chamber. Anterior segment optical coherence tomography (AS-OCT) images were made preoperatively to quantify AC depth. AS-OCT images were made twice under photopic and twice under scotopic conditions, in the angle parallel to the Baerveldt tube to quantify drainage tube position, at 3, 6, 12, and 24 months postoperatively. Tube-corneal (T-C) and tube-iris (T-I) distances were measured. Additionally, the central AC depth and the peripheral angle opening (AOD 500) were determined. Two subgroups were distinguished according to tube position: free in the AC (group 1, n = 48) and transiridal (group 2, n = 22). RESULTS After 24 months of follow-up, the drainage tube was found to move statistically significantly closer (0.12 mm) to the corneal endothelium in group 1 (p<0.01). There was no statistically significant difference in T-C distance over time in group 2. The T-C distance did not differ under photopic versus scotopic circumstances (p = 0.32). In both groups, the T-I distance was larger under scotopic conditions, a result of pupil dilation. CONCLUSIONS The Baerveldt glaucoma drainage tube remained in a stable position when a transiridal implantation was performed, whereas the tube moved closer to the endothelium when placed free into the AC. Transiridal implantation of the Baerveldt tube seems a safe alternative for tube implantation with respect to tube motility.
Collapse
|
33
|
Patel I, de Klerk TA, Au L. Manchester iStent study: early results from a prospective UK case series. Clin Exp Ophthalmol 2013; 41:648-52. [PMID: 23448425 DOI: 10.1111/ceo.12098] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Accepted: 01/17/2013] [Indexed: 10/27/2022]
Abstract
BACKGROUND To evaluate the 6-month efficacy and safety of the iStent microtrabecular bypass stent in patients with open-angle glaucoma. DESIGN A prospective, uncontrolled, interventional case series. PARTICIPANTS Forty-four eyes with open-angle glaucoma were reported. METHODS All subjects underwent ab interno implantation of a single iStent together with (n = 40) or without (n = 4) cataract surgery. MAIN OUTCOME MEASURES Patients were assessed at postoperative week 1, months 1 and 3, and quarterly, thereafter. Data collected included visual acuity, intraocular pressure measurement using Goldmann tonometry, number of glaucoma medications, and number and type of complications. RESULTS The mean age of the sample was 76.8 years. The mean duration since glaucoma diagnosis was 5.3 years (standard deviation 2.9 years). The mean visual acuity was 0.53 logMAR at baseline that improved to 0.23 at 6 months postoperatively. The mean baseline intraocular pressure was 21.1 mmHg, and this decreased significantly to 16.7 mmHg at 6 months (P < 0.01). The mean number of drops prescribed preoperatively was 2.3, which decreased to 0.6 at 6 months (P < 0.01). Sixty-six per cent of patients were drop-free at 6 months. One patient developed an hyphaema following surgery; no other adverse events were recorded. CONCLUSIONS The iStent proved to be a safe and effective treatment for patients with open-angle glaucoma over our 6-month follow up period. Insertion resulted in a significant decrease in intraocular pressure as well as the number of topical antiglaucoma medications required for adequate intraocular pressure control.
Collapse
Affiliation(s)
- Ilesh Patel
- Manchester Royal Eye Hospital, Central Manchester University Hospitals NHS Foundation Trust, Manchester, UK
| | | | | |
Collapse
|
34
|
Kim C, Radcliffe NM. One Year of Glaucoma Research in Review: 2011 to 2012. ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY (PHILADELPHIA, PA.) 2012; 1:364-73. [PMID: 26107730 DOI: 10.1097/apo.0b013e3182747e4c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To provide the practicing clinical ophthalmologist with an update of pertinent glaucoma literature published over the past 12 months. METHODS The authors conducted a one year (July 1, 2011 to June 30, 2012) English language glaucoma literature search on Pubmed using the following terms: automated perimetry, optic nerve imaging, optical coherence tomography, glaucoma structure and function, intraocular pressure, central corneal thickness, medical therapy and compliance in glaucoma, glaucoma laser treatment, cataract extraction and intraocular pressure, secondary glaucoma, glaucoma surgery, pediatric glaucoma, molecular biology in glaucoma, and miscellaneous topics in glaucoma. DESIGN Literature review. RESULTS This review includes original and review articles that reflect novel aspects and updates in the field of glaucoma, while excluding letters to the editor, unpublished works, and abstracts. CONCLUSIONS This review is not meant to be all-inclusive-rather, it highlights literature that is most applicable to ophthalmologists in practice.
Collapse
Affiliation(s)
- Charles Kim
- From the Department of Ophthalmology, Weill Cornell Medical College, New York, NY
| | | |
Collapse
|