Woo SE, Lee SH. A Comparison of Central Corneal Thickness Measurements and Measurement Repeatability Using Three Imaging Modalities. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2021. [DOI: 10.3341/jkos.2021.62.2.184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
2
|
Belovay GW, Goldberg I. The thick and thin of the central corneal thickness in glaucoma. Eye (Lond) 2018; 32:915-923. [PMID: 29445115 DOI: 10.1038/s41433-018-0033-3] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Revised: 01/15/2018] [Accepted: 01/17/2018] [Indexed: 11/09/2022] Open
Abstract
Central corneal thickness (CCT) is an important parameter in the assessment of any potential glaucoma patient. While it affects prognosis in ocular hypertension, its value in patients diagnosed with glaucoma is less certain. There are several biological factors and genetic components that may influence glaucoma progression, which have been associated with thinner CCT. The CCT itself can be affected by several factors including ethnicity, age, sex, glaucoma medications, genetics, and the subtype of glaucoma. Besides, there is variability in the measurement of CCT between difference types of devices. These factors need to be considered in the evaluation of glaucoma patients' CCT and its effect on interpretation of intraocular pressure levels and risk stratification.
Collapse
Affiliation(s)
| | - Ivan Goldberg
- Glaucoma Unit, Sydney Eye Hospital, Sydney, Australia.,Discipline of Ophthalmology, University of Sydney, Sydney, Australia.,Eye Associates, Sydney, Australia
| |
Collapse
|
3
|
Abstract
PURPOSE OF REVIEW The purpose of this review is to summarize the role of central corneal thickness (CCT) in the clinical management of a glaucoma patient. RECENT FINDINGS The prognostic value of CCT is well recognized in patients with ocular hypertension. However, its predictive value in other glaucoma suspects and patients with established glaucoma is less certain. Tonometry artefacts can result from variations in CCT. However, an adequately validated correction algorithm for Goldmann applanation tonometry measurements does not exist. Newer methods of tonometry are potentially less influenced by CCT but are limited in their clinical use. There may also be biological and genetic associations between corneal thickness and glaucoma. Demographics, environmental factors, glaucoma treatment and the measurement device used have a significant influence on CCT, and should be considered when interpreting the effect of cornea thickness in patients with glaucoma. New measurements of the biomechanical properties of the cornea are likely to be better approximations of the globe biomechanics than CCT, but these require further evaluation. SUMMARY The clinical significance of CCT is well recognized in the context of glaucoma diagnosis and management, though the extent of its importance remains debatable. Corneal biomechanical properties may be more significantly associated with glaucoma than CCT.
Collapse
|
4
|
Shin WB, Jeong HK, Kim MK, Kim HS, Lee JM, Kim CY, Kim JH. Comparison of Central Corneal Thickness Measured by Swept-source Optical Coherence Tomography and Ultrasound Pachymetry. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2017. [DOI: 10.3341/jkos.2017.58.3.276] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Woo Beom Shin
- Siloam Eye Hospital, Seoul, Korea
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | - Hyun Kyo Jeong
- Siloam Eye Hospital, Seoul, Korea
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | - Min Kyo Kim
- Siloam Eye Hospital, Seoul, Korea
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | | | | | - Chan Yun Kim
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
| | | |
Collapse
|
5
|
Effect of obstructive sleep apnea syndrome on corneal thickness. Int Ophthalmol 2015; 36:327-33. [PMID: 26292644 DOI: 10.1007/s10792-015-0122-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Accepted: 08/12/2015] [Indexed: 10/23/2022]
Abstract
Obstructive sleep apnea syndrome (OSAS) might be a risk factor for the development of eye disorders. The aim of the study was to evaluate the effect of OSAS on central corneal thickness (CCT). A total of 195 patients were enrolled in the study, and underwent polysomnography. Patients were divided according to their apnea-hypopnea index (AHI) scores into control group (AHI < 5), mild (AHI, 5-15), moderate (AHI, 15-30), and severe OSAS (AHI > 30) groups. In ophthalmological examinations, CCT, auto refractometer measurement, tear break-up time, and Schrimer's test results were evaluated. Central corneal thickness was significantly decreased in patients with OSAS compared to the control group (542.14 ± 31.21 vs. 569.92 ± 13.46, p < 0.001). As the severity of OSAS increased, CCT decreased (mild OSAS = 567.48 ± 23 mm, moderate OSAS = 530.21 ± 30.2 mm, and severe OSAS = 557.97 ± 16.52 mm, respectively, p < 0.001). The mean values of auto refractometer, tear break-up time, and Schrimer's test were similar between the groups (p > 0.05). CCT was negatively correlated with AHI, oxygen desaturation index, desaturation percentages, and positively correlated with minimum oxygen saturation values (p < 0.05). This study showed that central corneal thickness is inversely correlated with the severity of OSAS. OSAS affects all organ systems particularly cardiovascular and neurological mechanisms. Further studies are warranted to evaluate the effect of OSAS treatment on CCT.
Collapse
|
6
|
Ramamurthy S, Reddy JC, Jhanji V. Topography and tomography in the diagnosis of corneal ectasia. EXPERT REVIEW OF OPHTHALMOLOGY 2015. [DOI: 10.1586/17469899.2015.1044979] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
7
|
Lee MJ, Shin YU, Lim HW, Kang MH, Cho HY, Seong MC. Central Corneal Thickness Measured by Noncontact Specular Microscopy, Dual Rotating Scheimpflug Camera and Ultrasound Pachymetry. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2015. [DOI: 10.3341/jkos.2015.56.10.1520] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Min Jee Lee
- Department of Ophthalmology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| | - Yong Un Shin
- Department of Ophthalmology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| | - Han Woong Lim
- Department of Ophthalmology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| | - Min Ho Kang
- Department of Ophthalmology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| | - Hee Yoon Cho
- Department of Ophthalmology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| | - Min Cheol Seong
- Department of Ophthalmology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
| |
Collapse
|
8
|
Cerviño A, Dominguez-Vicent A, Ferrer-Blasco T, García-Lázaro S, Albarrán-Diego C. Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system. J Cataract Refract Surg 2015; 41:186-92. [DOI: 10.1016/j.jcrs.2014.04.037] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2014] [Revised: 03/24/2014] [Accepted: 04/14/2014] [Indexed: 12/14/2022]
|
9
|
Asher R, Gefen A, Moisseiev E, Varssano D. An Analytical Approach to Corneal Mechanics for Determining Practical, Clinically-Meaningful Patient-Specific Tissue Mechanical Properties in the Rehabilitation of Vision. Ann Biomed Eng 2014; 43:274-86. [DOI: 10.1007/s10439-014-1147-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 09/30/2014] [Indexed: 11/28/2022]
|
10
|
Hernández-Camarena JC, Chirinos-Saldaña P, Navas A, Ramirez-Miranda A, de la Mota A, Jimenez-Corona A, Graue-Hernández EO. Repeatability, Reproducibility, and Agreement Between Three Different Scheimpflug Systems in Measuring Corneal and Anterior Segment Biometry. J Refract Surg 2014; 30:616-21. [DOI: 10.3928/1081597x-20140815-02] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
11
|
Comparison of normal and keratoconic corneas by Galilei Dual-Scheimpflug Analyzer. Cont Lens Anterior Eye 2013; 36:219-25. [DOI: 10.1016/j.clae.2013.04.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2012] [Revised: 03/30/2013] [Accepted: 04/02/2013] [Indexed: 11/13/2022]
|
12
|
Huang J, Ding X, Savini G, Pan C, Feng Y, Cheng D, Hua Y, Hu X, Wang Q. A Comparison between Scheimpflug Imaging and Optical Coherence Tomography in Measuring Corneal Thickness. Ophthalmology 2013; 120:1951-8. [DOI: 10.1016/j.ophtha.2013.02.022] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2012] [Revised: 02/17/2013] [Accepted: 02/18/2013] [Indexed: 11/16/2022] Open
|
13
|
Ortak H, İnanır A, Demir S, Uysal A, Şahin Ş, Sağcan M, Önder Y, Alim S, Demir AK. Decreased central corneal thickness in ankylosing spondylitis. Int Ophthalmol 2013; 34:263-8. [DOI: 10.1007/s10792-013-9827-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Accepted: 07/03/2013] [Indexed: 10/26/2022]
|
14
|
Kim DW, Yi KY, Choi DG, Shin YJ. Corneal Thickness Measured by Dual Scheimpflug, Anterior Segment Optical Coherence Tomography, and Ultrasound Pachymetry. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2012. [DOI: 10.3341/jkos.2012.53.10.1412] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Dong Wook Kim
- Department of Ophthalmology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Ka Young Yi
- Department of Ophthalmology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Dong Gyu Choi
- Department of Ophthalmology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Young Joo Shin
- Department of Ophthalmology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| |
Collapse
|