1
|
Willmann R, Almeida M, Stoppa E, Barbisan LF, Miranda JRA, Soares G. Evaluation and imaging of biodistribution of magnetic nanoparticles in a model of hepatic cirrhosis via alternating current biosusceptometry. Biomed Phys Eng Express 2024; 10:065024. [PMID: 39260388 DOI: 10.1088/2057-1976/ad795b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Accepted: 09/11/2024] [Indexed: 09/13/2024]
Abstract
In recent years, magnetic nanoparticles (MNPs) have exhibited theragnostic characteristics which confer a wide range of applications in the biomedical field. Consequently, through Alternating Current Biosusceptometry (ACB), magnetic nanoparticles can be used as tracers, allowing the study of healthy and cirrhotic livers and providing the ability to differentiate them through the reconstruction of quantitative images. The ACB system consists of a developing biomagnetic technique that has the ability to magnetize and measure the magnetic susceptibility of a material such as MNPs, thereby offering quantitative information about biological systems with magnetic tracers.
Collapse
Affiliation(s)
- Raffael Willmann
- Department of Biophysics and Pharmacology, Institute of Biosciences, São Paulo State University-UNESP, Botucatu, 18618-689, SP, Brazil
| | - Michael Almeida
- Department of Biophysics and Pharmacology, Institute of Biosciences, São Paulo State University-UNESP, Botucatu, 18618-689, SP, Brazil
| | - Erick Stoppa
- Department of Biophysics and Pharmacology, Institute of Biosciences, São Paulo State University-UNESP, Botucatu, 18618-689, SP, Brazil
| | - Luis F Barbisan
- Department of Structural and Functional Biology, Institute of Biosciences, São Paulo State University-UNESP, Botucatu, 18618-689, SP, Brazil
| | - Jose R A Miranda
- Department of Biophysics and Pharmacology, Institute of Biosciences, São Paulo State University-UNESP, Botucatu, 18618-689, SP, Brazil
| | - Guilherme Soares
- Department of Biophysics and Pharmacology, Institute of Biosciences, São Paulo State University-UNESP, Botucatu, 18618-689, SP, Brazil
| |
Collapse
|
2
|
Baabu PRS, Kumar HK, Gumpu MB, Babu K J, Kulandaisamy AJ, Rayappan JBB. Iron Oxide Nanoparticles: A Review on the Province of Its Compounds, Properties and Biological Applications. MATERIALS (BASEL, SWITZERLAND) 2022; 16:ma16010059. [PMID: 36614400 PMCID: PMC9820855 DOI: 10.3390/ma16010059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/13/2022] [Accepted: 12/15/2022] [Indexed: 05/14/2023]
Abstract
Materials science and technology, with the advent of nanotechnology, has brought about innumerable nanomaterials and multi-functional materials, with intriguing yet profound properties, into the scientific realm. Even a minor functionalization of a nanomaterial brings about vast changes in its properties that could be potentially utilized in various applications, particularly for biological applications, as one of the primary needs at present is for point-of-care devices that can provide swifter, accurate, reliable, and reproducible results for the detection of various physiological conditions, or as elements that could increase the resolution of current bio-imaging procedures. In this regard, iron oxide nanoparticles, a major class of metal oxide nanoparticles, have been sweepingly synthesized, characterized, and studied for their essential properties; there are 14 polymorphs that have been reported so far in the literature. With such a background, this review's primary focus is the discussion of the different synthesis methods along with their structural, optical, magnetic, rheological and phase transformation properties. Subsequently, the review has been extrapolated to summarize the effective use of these nanoparticles as contrast agents in bio-imaging, therapeutic agents making use of its immune-toxicity and subsequent usage in hyperthermia for the treatment of cancer, electron transfer agents in copious electrochemical based enzymatic or non-enzymatic biosensors and bactericidal coatings over biomaterials to reduce the biofilm formation significantly.
Collapse
Affiliation(s)
- Priyannth Ramasami Sundhar Baabu
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur 613 401, Tamil Nadu, India
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - Hariprasad Krishna Kumar
- School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur 613 401, Tamil Nadu, India
- Acrophase, Indian Institute of Technology Madras, Chennai 600 036, Tamil Nadu, India
| | - Manju Bhargavi Gumpu
- Department of Physics, National Institute of Technology, Tiruchirappalli 620 015, Tamil Nadu, India
| | - Jayanth Babu K
- Centre for Nanotechnology & Advanced Biomaterials (CeNTAB), SASTRA Deemed University, Thanjavur 613 401, Tamil Nadu, India
- School of Electrical & Electronics Engineering, SASTRA Deemed University, Thanjavur 613 401, Tamil Nadu, India
| | | | - John Bosco Balaguru Rayappan
- Centre for Nanotechnology & Advanced Biomaterials (CeNTAB), SASTRA Deemed University, Thanjavur 613 401, Tamil Nadu, India
- School of Electrical & Electronics Engineering, SASTRA Deemed University, Thanjavur 613 401, Tamil Nadu, India
- Correspondence:
| |
Collapse
|
3
|
Magnetic resonance imaging of umbilical cord stem cells labeled with superparamagnetic iron oxide nanoparticles: effects of labelling and transplantation parameters. Sci Rep 2020; 10:13684. [PMID: 32792506 PMCID: PMC7426806 DOI: 10.1038/s41598-020-70291-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 07/28/2020] [Indexed: 12/18/2022] Open
Abstract
Cell tracking with magnetic resonance imaging (MRI) is important for evaluating the biodistribution of transplanted cells. Umbilical cord-derived mesenchymal stem cells (UC-MSCs) have emerged as a promising therapeutic tool in regenerative medicine. We examined the UC-MSCs labeled with superparamagnetic (SPIO) and ultrasmall superparamagnetic iron oxide (USPIO) in terms of cell functioning and imaging efficiency in vitro and in vivo. The UC-MSCs were co-incubated with SPIO or USPIO at a concentration of 50 or 100 µg/mL of label. Viability and proliferation were assessed by Trypan blue dye exclusion and MTT assay, respectively. Differentiation (chondrogenesis, osteogenesis, and adipogenesis) was induced to examine the impact of labelling on stemness. For in vitro experiments, we used 7-T MRI to assess the T2 values of phantoms containing various concentrations of cell suspensions. For in vivo experiments, nine neonatal rats were divided into the control, SPIO, and USPIO groups. The UC-MSCs were injected directly into the rat brains. MRI images were obtained immediately and at 7 and 14 days post injection. The UC-MSCs were successfully labeled with SPIO and USPIO after 24 h of incubation. Cell viability was not changed by labelling. Nevertheless, labelling with 100 µg/mL USPIO led to a significant decrease in proliferation. The capacity for differentiation into cartilage was influenced by 100 µg/mL of SPIO. MRI showed that labeled cells exhibited clear hypointense signals, unlike unlabeled control cells. In the USPIO-labeled cells, a significant (P < 0.05) decrease in T2 values (= improved contrast) was observed when compared with the controls and between phantoms containing the fewest and the most cells (0.5 × 106 versus 2.0 × 106 cells/mL). In vivo, the labeled cells were discernible on T2-weighted images at days 0, 7, and 14. The presence of SPIO and USPIO particles at day 14 was confirmed by Prussian blue staining. Microscopy also suggested that the regions occupied by the particles were not as large as the corresponding hypointense areas observed on MRI. Both labels were readily taken up by the UC-MSCs and identified well on MRI. While SPIO and USPIO provide improved results in MRI studies, care must be taken while labelling cells with high concentrations of these agents.
Collapse
|
4
|
Yang DW, Wang XP, Wang ZC, Yang ZH, Bian XF. A scientometric analysis on hepatocellular carcinoma magnetic resonance imaging research from 2008 to 2017. Quant Imaging Med Surg 2019; 9:465-476. [PMID: 31032193 DOI: 10.21037/qims.2019.02.10] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Background With the development of new magnetic resonance imaging (MRI) techniques, an increasing number of articles have been published regarding hepatocellular carcinoma magnetic resonance imaging (HCCMRI) in the past decade. However, few studies have statistically analyzed these published articles. In this study, we aim to systematically evaluate the scientific outcomes of HCCMRI research and explore the research hotspots from 2008 to 2017. Methods The included articles regarding HCCMRI research from 2008 to 2017 were downloaded from the Web of Science Core Collection and verified by two experienced radiologists. Excel 2016 was used to analyze the literature data, including the publication years and journals. CiteSpace V was used to perform co-occurrence analyses for authors, countries/regions and institutions and to generate the related collaboration network maps. Reference co-citation analysis (RCA) and burst keyword detection were also performed using CiteSpace V to explore the research hotspots in the past decade. Results A total of 835 HCCMRI articles published from 2008 to 2017 were identified. Journal of Magnetic Resonance Imaging published the most articles (79 publications, 9.46%). Extensive cooperating relationship were observed among countries/regions and among authors. South Korea had the most publications (199 publications, 21.82%), followed by the United States of America (USA) (190 publications, 20.83%), Japan (162 publications, 17.76%), and the People's Republic of China (148 publications, 16.23%). Among the top 10 co-cited authors, Bruix J (398 citations) was ranked first, followed by Llovet JM (235 citations), Kim YK (170 citations) and Forner A (152 citations). According to the RCA, ten major clusters were explored over the last decade; "LI-RADS data system" and "microvascular invasion" (MVI) were the two most recent clusters. Forty-seven burst keywords with the highest citation strength were detected over time. Of these keywords, "microvascular invasion" had the highest strength in the last 3 years. The LI-RADS has been constantly updated with the latest edition released in July 2018. However, the LI-RADS still has limitations in identifying certain categories of lesions by conceptual and non-quantitative probabilistic methods. Plenty of questions still need to be further answered such as the difference of diagnostic efficiency of each major/ancillary imaging features. Preoperative prediction of MVI of HCC is very important to therapeutic decision-making. Some parameters of Gd-EOB-DTPA-enhanced MRI were found to be useful in prediction of MVI, however, with a high specificity but a very low sensitivity. Comprehensive predictive model incorporating both imaging and clinical variables may be the more preferable in prediction of MVI of HCC. Conclusions HCCMRI-related publications displayed a gradually increasing trend from 2008 to 2017. The USA has a central position in collaboration with other countries/regions, while South Korea contributed the most in the number of publications. Of the ten major clusters identified in the RCA, the two most recent clusters were "LI-RADS data system" and "microvascular invasion", indicative of the current HCCMRI research hotspots.
Collapse
Affiliation(s)
- Da-Wei Yang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China.,Beijing Key Laboratory of Translational Medicine on Liver Cirrhosis, Beijing 100050, China.,Department of Radiology, Hotan District People's Hospital, Hotan 848000, China
| | - Xiao-Pei Wang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Zhen-Chang Wang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Zheng-Han Yang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Xue-Feng Bian
- Department of Radiology, Hotan District People's Hospital, Hotan 848000, China
| |
Collapse
|
5
|
Wáng YXJ, Idée JM. A comprehensive literatures update of clinical researches of superparamagnetic resonance iron oxide nanoparticles for magnetic resonance imaging. Quant Imaging Med Surg 2017; 7:88-122. [PMID: 28275562 DOI: 10.21037/qims.2017.02.09] [Citation(s) in RCA: 150] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
This paper aims to update the clinical researches using superparamagnetic iron oxide (SPIO) nanoparticles as magnetic resonance imaging (MRI) contrast agent published during the past five years. PubMed database was used for literature search, and the search terms were (SPIO OR superparamagnetic iron oxide OR Resovist OR Ferumoxytol OR Ferumoxtran-10) AND (MRI OR magnetic resonance imaging). The literature search results show clinical research on SPIO remains robust, particularly fuelled by the approval of ferumoxytol for intravenously administration. SPIOs have been tested on MR angiography, sentinel lymph node detection, lymph node metastasis evaluation; inflammation evaluation; blood volume measurement; as well as liver imaging. Two experimental SPIOs with unique potentials are also discussed in this review. A curcumin-conjugated SPIO can penetrate brain blood barrier (BBB) and bind to amyloid plaques in Alzheime's disease transgenic mice brain, and thereafter detectable by MRI. Another SPIO was fabricated with a core of Fe3O4 nanoparticle and a shell coating of concentrated hydrophilic polymer brushes and are almost not taken by peripheral macrophages as well as by mononuclear phagocytes and reticuloendothelial system (RES) due to the suppression of non-specific protein binding caused by their stealthy ''brush-afforded'' structure. This SPIO may offer potentials for the applications such as drug targeting and tissue or organ imaging other than liver and lymph nodes.
Collapse
Affiliation(s)
- Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Prince of Wales Hospital, Sha Tin, New Territories, Hong Kong SAR, China
| | - Jean-Marc Idée
- Guerbet, Research and Innovation Division, Roissy-Charles de Gaulle, France
| |
Collapse
|
6
|
Chen T, Mori Y, Inui-Yamamoto C, Komai Y, Tago Y, Yoshida S, Takabatake Y, Isaka Y, Ohno K, Yoshioka Y. Polymer-brush-afforded SPIO Nanoparticles Show a Unique Biodistribution and MR Imaging Contrast in Mouse Organs. Magn Reson Med Sci 2017; 16:275-283. [PMID: 28132997 PMCID: PMC5743518 DOI: 10.2463/mrms.mp.2016-0067] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Introduction: To investigate the biodistribution and retention properties of the new super paramagnetic iron oxide (new SPIO: mean hydrodynamic diameter, 100 nm) nanoparticles, which have concentrated polymer brushes in the outer shell and are difficult for phagocytes to absorb, and to compare the new SPIO with clinically approved SPIO (Resovist: mean hydrodynamic diameter, 57 nm). Materials and Methods: 16 male C57BL/6N mice were divided in two groups according to the administered SPIO (n = 8 for each group; intravenous injection does, 0.1 ml). In vivo magnetic resonance imaging (MRI) was performed before and one hour, one day, one week and four weeks after SPIO administration by two dimensional-the fast low angle shot (2D-FLASH) sequence at 11.7T. Ex vivo high-resolution images of fixed organs were also obtained by (2D-FLASH). After the ex vivo MRI, organs were sectioned and evaluated histologically to confirm the biodistribution of each particle precisely. Results: The new SPIO was taken up in small amounts by liver Kupffer cells and showed a unique in vivo MRI contrast pattern in the kidneys, where the signal intensity decreased substantially in the boundaries between cortex and outer medulla and between outer and inner medulla. We found many round dark spots in the cortex by ex vivo MRI in both groups. Resovist could be detected almost in the cortex. The shapes of the dark spots were similar to those observed in the new SPIO group. Transmission electron microscopy revealed that Resovist and the new SPIO accumulated in different cells of glomeruli, that is, endothelial and mesangial cells, respectively. Conclusion: The new SPIO was taken up in small amounts by liver tissue and showed a unique MRI contrast pattern in the kidney. The SPIO were found in the mesangial cells of renal corpuscles. Our results indicate that the new SPIO may be potentially be used as a new contrast agent for evaluation of kidney function as well as immunune function.
Collapse
Affiliation(s)
- Ting Chen
- Biofunctional Imaging Laboratory, WPI Immunology Frontier Research Center (WPI IFReC), Osaka University.,Functional Imaging Technology, Center for Information and Neural Networks (CiNet), National Institute of Information and Communications Technology (NICT) and Osaka University
| | - Yuki Mori
- Biofunctional Imaging Laboratory, WPI Immunology Frontier Research Center (WPI IFReC), Osaka University.,Functional Imaging Technology, Center for Information and Neural Networks (CiNet), National Institute of Information and Communications Technology (NICT) and Osaka University
| | - Chizuko Inui-Yamamoto
- Biofunctional Imaging Laboratory, WPI Immunology Frontier Research Center (WPI IFReC), Osaka University.,Functional Imaging Technology, Center for Information and Neural Networks (CiNet), National Institute of Information and Communications Technology (NICT) and Osaka University
| | - Yutaka Komai
- Biofunctional Imaging Laboratory, WPI Immunology Frontier Research Center (WPI IFReC), Osaka University
| | - Yoshiyuki Tago
- Biotechnology Development Laboratories, Kaneka Corporation
| | | | | | - Yoshitaka Isaka
- Department of Nephrology, Osaka University Graduate School of Medicine
| | - Kohji Ohno
- Institute for Chemical Research, Kyoto University
| | - Yoshichika Yoshioka
- Biofunctional Imaging Laboratory, WPI Immunology Frontier Research Center (WPI IFReC), Osaka University.,Functional Imaging Technology, Center for Information and Neural Networks (CiNet), National Institute of Information and Communications Technology (NICT) and Osaka University
| |
Collapse
|
7
|
Abstract
In vivo imaging, which enables us to peer deeply within living subjects, is producing tremendous opportunities both for clinical diagnostics and as a research tool. Contrast material is often required to clearly visualize the functional architecture of physiological structures. Recent advances in nanomaterials are becoming pivotal to generate the high-resolution, high-contrast images needed for accurate, precision diagnostics. Nanomaterials are playing major roles in imaging by delivering large imaging payloads, yielding improved sensitivity, multiplexing capacity, and modularity of design. Indeed, for several imaging modalities, nanomaterials are now not simply ancillary contrast entities, but are instead the original and sole source of image signal that make possible the modality's existence. We address the physicochemical makeup/design of nanomaterials through the lens of the physical properties that produce contrast signal for the cognate imaging modality-we stratify nanomaterials on the basis of their (i) magnetic, (ii) optical, (iii) acoustic, and/or (iv) nuclear properties. We evaluate them for their ability to provide relevant information under preclinical and clinical circumstances, their in vivo safety profiles (which are being incorporated into their chemical design), their modularity in being fused to create multimodal nanomaterials (spanning multiple different physical imaging modalities and therapeutic/theranostic capabilities), their key properties, and critically their likelihood to be clinically translated.
Collapse
Affiliation(s)
- Bryan Ronain Smith
- Stanford University , 3155 Porter Drive, #1214, Palo Alto, California 94304-5483, United States
| | - Sanjiv Sam Gambhir
- The James H. Clark Center , 318 Campus Drive, First Floor, E-150A, Stanford, California 94305-5427, United States
| |
Collapse
|
8
|
Iron overload by Superparamagnetic Iron Oxide Nanoparticles is a High Risk Factor in Cirrhosis by a Systems Toxicology Assessment. Sci Rep 2016; 6:29110. [PMID: 27357559 PMCID: PMC4928111 DOI: 10.1038/srep29110] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Accepted: 06/15/2016] [Indexed: 12/14/2022] Open
Abstract
Superparamagnetic iron oxide nanoparticles (SPIONs) as a contrast agent have been widely used in magnetic resonance imaging for tumor diagnosis and theranostics. However, there has been safety concern of SPIONs with cirrhosis related to excess iron-induced oxidative stress. In this study, the impact of iron overload by SPIONs was assessed on a mouse cirrhosis model. A single dose of SPION injection at 0.5 or 5 mg Fe/kg in the cirrhosis group induced a septic shock response at 24 h with elevated serum levels of liver and kidney function markers and extended impacts over 14 days including high levels of serum cholesterols and persistent low serum iron level. In contrast, full restoration of liver functions was found in the normal group with the same dosages over time. Analysis with PCR array of the toxicity pathways revealed the high dose of SPIONs induced significant expression changes of a distinct subset of genes in the cirrhosis liver. All these results suggested that excess iron of the high dose of SPIONs might be a risk factor for cirrhosis because of the marked impacts of elevated lipid metabolism, disruption of iron homeostasis and possibly, aggravated loss of liver functions.
Collapse
|
9
|
Wang J, Choi HS, Wáng YXJ. Exponential growth of publications on carbon nanodots by Chinese authors. J Thorac Dis 2015; 7:E201-5. [PMID: 26380753 DOI: 10.3978/j.issn.2072-1439.2015.06.13] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Accepted: 06/13/2015] [Indexed: 12/18/2022]
Abstract
Publication statistics was retrieved on carbon nanodots (C-dots) from 2004 up till 2014 using the web of Science(TM) search engine. The number of publications from Chinese authors increased exponentially during this period. Till 2014 China mainland authors contributed 47% of the total publications. Publications on pharmacology and toxicology lagged far behind the publications on chemistry and material science, indicating that research is not solidly moving toward the direction of application.
Collapse
Affiliation(s)
- Junqing Wang
- 1 Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong SAR, China ; 2 Center for Molecular Imaging, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
| | - Hak Soo Choi
- 1 Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong SAR, China ; 2 Center for Molecular Imaging, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
| | - Yì-Xiáng J Wáng
- 1 Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong SAR, China ; 2 Center for Molecular Imaging, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
| |
Collapse
|
10
|
Mainenti PP, Romano F, Pizzuti L, Segreto S, Storto G, Mannelli L, Imbriaco M, Camera L, Maurea S. Non-invasive diagnostic imaging of colorectal liver metastases. World J Radiol 2015; 7:157-169. [PMID: 26217455 PMCID: PMC4506934 DOI: 10.4329/wjr.v7.i7.157] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Revised: 05/10/2015] [Accepted: 06/02/2015] [Indexed: 02/06/2023] Open
Abstract
Colorectal cancer is one of the few malignant tumors in which synchronous or metachronous liver metastases [colorectal liver metastases (CRLMs)] may be treated with surgery. It has been demonstrated that resection of CRLMs improves the long-term prognosis. On the other hand, patients with un-resectable CRLMs may benefit from chemotherapy alone or in addition to liver-directed therapies. The choice of the most appropriate therapeutic management of CRLMs depends mostly on the diagnostic imaging. Nowadays, multiple non-invasive imaging modalities are available and those have a pivotal role in the workup of patients with CRLMs. Although extensive research has been performed with regards to the diagnostic performance of ultrasonography, computed tomography, positron emission tomography and magnetic resonance for the detection of CRLMs, the optimal imaging strategies for staging and follow up are still to be established. This largely due to the progressive technological and pharmacological advances which are constantly improving the accuracy of each imaging modality. This review describes the non-invasive imaging approaches of CRLMs reporting the technical features, the clinical indications, the advantages and the potential limitations of each modality, as well as including some information on the development of new imaging modalities, the role of new contrast media and the feasibility of using parametric image analysis as diagnostic marker of presence of CRLMs.
Collapse
|
11
|
Li YW, Chen ZG, Wang JC, Zhang ZM. Superparamagnetic iron oxide-enhanced magnetic resonance imaging for focal hepatic lesions: Systematic review and meta-analysis. World J Gastroenterol 2015; 21:4334-4344. [PMID: 25892885 PMCID: PMC4394096 DOI: 10.3748/wjg.v21.i14.4334] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Revised: 10/25/2014] [Accepted: 11/19/2014] [Indexed: 02/06/2023] Open
Abstract
AIM: To evaluate the performance of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging (MRI) in the detection and characterization of focal hepatic lesions (FHLs).
METHODS: This meta-analysis compared relevant studies that were identified by searching PubMed, EMBASE, and the Cochrane Library databases for articles published between January 1988 and September 2014 and that met the following criteria: (1) SPIO-enhanced MRI was conducted to identify FHLs and data were sufficient for pooled analysis using Meta-DiSc 1.4; (2) hepatocellular carcinomas (HCCs) were differentiated from other FHLs; (3) well-differentiated HCCs (WD-HCCs) were contradistinguished from dysplastic nodules; and (4) WD-HCCs were compared with moderately and poorly differentiated HCCs (MD- and PD-HCCs, respectively).
RESULTS: The data obtained from 15 eligible studies yielded a sensitivity of 85% and a specificity of 78% for differentiating between HCCs and other FHLs. The sensitivity was unchanged and the specificity was increased to 87% when non-HCC malignancies were excluded. Comparative analyses between WD-HCCs and MD- and PD-HCCs from seven studies showed a sensitivity of 98% and a specificity of 50% for the diagnosis of MD- and PD-HCCs, and the area under the summary receiver operating characteristics (sROC) curve was 0.97. A comparison between WD-HCCs and dysplastic nodules revealed a sensitivity of 50% and a specificity of 92% for the diagnosis of WD-HCCs and the area under the sROC curve was 0.80.
CONCLUSION: SPIO-enhanced MRI is useful in differentiating between HCCs and other FHLs.
Collapse
|
12
|
Wáng YXJ, De Baere T, Idée JM, Ballet S. Transcatheter embolization therapy in liver cancer: an update of clinical evidences. Chin J Cancer Res 2015; 27:96-121. [PMID: 25937772 PMCID: PMC4409973 DOI: 10.3978/j.issn.1000-9604.2015.03.03] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Accepted: 02/05/2015] [Indexed: 12/20/2022] Open
Abstract
Transarterial chemoembolization (TACE) is a form of intra-arterial catheter-based chemotherapy that selectively delivers high doses of cytotoxic drug to the tumor bed combining with the effect of ischemic necrosis induced by arterial embolization. Chemoembolization and radioembolization are at the core of the treatment of liver hepatocellular carcinoma (HCC) patients who cannot receive potentially curative therapies such as transplantation, resection or percutaneous ablation. TACE for liver cancer has been proven to be useful in local tumor control, to prevent tumor progression, prolong patients' life and control patient symptoms. Recent evidence showed in patients with single-nodule HCC of 3 cm or smaller without vascular invasion, the 5-year overall survival (OS) with TACE was similar to that with hepatic resection and radiofrequency ablation. Although being used for decades, Lipiodol(®) (Lipiodol(®) Ultra Fluid(®), Guerbet, France) remains important as a tumor-seeking and radio-opaque drug delivery vector in interventional oncology. There have been efforts to improve the delivery of chemotherapeutic agents to tumors. Drug-eluting bead (DEB) is a relatively novel drug delivery embolization system which allows for fixed dosing and the ability to release the anticancer agents in a sustained manner. Three DEBs are available, i.e., Tandem(®) (CeloNova Biosciences Inc., USA), DC-Beads(®) (BTG, UK) and HepaSphere(®) (BioSphere Medical, Inc., USA). Transarterial radioembolization (TARE) technique has been developed, and proven to be efficient and safe in advanced liver cancers and those with vascular complications. Two types of radioembolization microspheres are available i.e., SIR-Spheres(®) (Sirtex Medical Limited, Australia) and TheraSphere(®) (BTG, UK). This review describes the basic procedure of TACE, properties and efficacy of some chemoembolization systems and radioembolization agents which are commercially available and/or currently under clinical evaluation. The key clinical trials of transcatheter arterial therapy for liver cancer are summarized.
Collapse
|