1
|
Wang Z, Ma H, Zhang Y, Yuan Y, Liu Y, Chen Y. Changes in Anterior Chamber After Myopic and Hyperopic FS-LASIK. Ophthalmol Ther 2022; 11:2243-2257. [PMID: 36205877 DOI: 10.1007/s40123-022-00579-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 09/14/2022] [Indexed: 11/24/2022] Open
Abstract
INTRODUCTION This study evaluated the changes and explored influential factors in the anterior chamber after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) on the basis of patients with different degrees of myopia, refractive status, and age. METHODS Patients underwent uneventful FS-LASIK for the treatment of ametropia. All patients with myopia were classified into a low age group (18-40 years) or high age group (> 40 years). Patients in the low age group (18-40 years) were subdivided into myopia and hyperopia groups. According to the preoperative spherical equivalent values, the myopia group was further divided into low myopia, moderate myopia, and high myopia groups. We measured the magnitude of anterior chamber depth (ACD), angle (ACA), volume (ACV), lens rise, central corneal thickness (CCT), and mean pupil power (MPP) of all patients using Sirius (version 3.2, CSO, Italy) before and 3 months post operation. RESULTS A total of 140 eyes of 87 patients were evaluated. The magnitudes of ACD, ACA, and ACV decreased significantly postoperatively in both low age (P < 0.001, P < 0.001, P < 0.001, respectively) and high age group (P < 0.001, P < 0.001, P < 0.001, respectively) of patients with myopia, while an increasing tendency of ACD (2.85 ± 0.38 mm preoperatively vs 2.89 ± 0.09 mm postoperatively) and ACA (39.16° ± 7.30° preoperatively vs 39.37° ± 7.68° postoperatively) was found in hyperopia. There was no correlation between different degrees of myopia and the changes in the anterior chamber. CONCLUSIONS Anterior chamber parameters decreased significantly and approximately in the same degree in low and high age groups postoperatively, while an increasing tendency of ACD and ACA was found in hyperopia, indicating that it is probably a corneal magnification effect that influences changes in the anterior chamber.
Collapse
Affiliation(s)
- Zizhen Wang
- Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China.,Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Haowen Ma
- Peking University Health Science Center, 38 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Yu Zhang
- Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China.,Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Yifei Yuan
- Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China.,Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Yan Liu
- Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China.,Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Yueguo Chen
- Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China. .,Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China.
| |
Collapse
|
2
|
Li Y, Gokul A, McGhee C, Ziaei M. Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus. PLoS One 2021; 16:e0248350. [PMID: 34143790 PMCID: PMC8213071 DOI: 10.1371/journal.pone.0248350] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Accepted: 02/24/2021] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To investigate the repeatability in corneal thickness (CT) and epithelial thickness (ET) measurements using spectral domain anterior segment optical coherence tomography (AS-OCT, REVO NX, Optopol) in keratoconus, and examine the effect of corneal crosslinking (CXL) on repeatability. METHODS A cross-sectional study of 259 eyes of 212 patients with keratoconus attending the corneal disease clinic at a university hospital tertiary referral center were enrolled. Two groups were analysed: eyes with no prior history of CXL (Group A) and eyes with prior CXL (Group B). Repeatability of measurements was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV). RESULTS In Group A, central corneal thickness (CCT) was 472.18 ± 45.41μm, and the ET was found to be the thinnest in the inferior-temporal aspect at 51.79 ± 5.97μm and thickest at the superior-nasal aspect at 56.07 ± 5.70μm. In Group B, CCT was 465.11± 42.28μm, and the ET was the thinnest at the inferior-temporal aspect at 50.63 ± 5.52μm and thickest at the superior aspect at 56.80 ± 6.39μm. When evaluating CT measurements, ICC was above 0.86 and 0.83 for Group A and Group B respectively. When evaluating ET measurements, ICC was above 0.82 for both groups. CXL had no statistically significant impact on the repeatability of measurements. CONCLUSIONS AS-OCT provides repeatable CT and ET measurements in the central and peripheral cornea in patients with keratoconus. Repeatability is not affected by a history of CXL.
Collapse
Affiliation(s)
- Ye Li
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Akilesh Gokul
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Charles McGhee
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Mohammed Ziaei
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
3
|
Wang Z, Yang W, Li D, Chen W, Zhao Q, Li Y, Cui R, Shen L, Xian J. Evaluation and comparison of a novel Scheimpflug-based optical biometer with standard partial coherence interferometry for biometry and intraocular lens power calculation. Exp Ther Med 2021; 21:326. [PMID: 33732299 PMCID: PMC7903467 DOI: 10.3892/etm.2021.9757] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 01/08/2021] [Indexed: 11/29/2022] Open
Abstract
In the present study, the axial length (AL), corneal curvature, anterior chamber depth (ACD) and white-to-white (WTW) distance were assessed using the Pentacam AXL (Oculus Optikgeraete GmbH), a novel Scheimpflug-based optical biometer with standard partial coherence interferometry (PCI). The Pentacam AXL and PCI biometer (IOLMaster 500; Carl Zeiss AG) were compared in terms of their intraocular lens (IOL) power calculations. The medical records of patients (eyes, n=190) who underwent cataract surgery were retrospectively reviewed. Biometry measurements involved the eyes of patients with cataract and were performed by the same examiner with the Pentacam AXL biometer and the IOLMaster 500 device. Following determination of the AL, mean keratometry (Km), ACD and WTW distance, the IOL power calculation was compared between the two devices using the Sanders, Retzlaff and Kraff theoretical (SRK/T) and Haigis formulas. The AL, Km and WTW values for the Pentacam AXL group were significantly lower compared with those of the IOLMaster 500 group. The difference was -0.02±0.04 mm, -0.20±0.28 D and -0.10±0.20 mm, respectively (P<0.001). The ACD for the Pentacam AXL group was higher compared with that of the IOLMaster 500 group with a difference of 0.02±0.13 mm (P=0.13). The IOL power calculated using the SRK/T and Haigis formulas exhibited significant differences between the two devices (t=11.48 and 10.97, respectively; P<0.001). In conclusion, the AL, ACD, WTW measurement and IOL power indicated optimal agreement and strong correlations between the two devices. However, constant optimization may be necessary for the novel biometer Pentacam AXL.
Collapse
Affiliation(s)
- Ziyang Wang
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Wenli Yang
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Dongjun Li
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Wei Chen
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Qi Zhao
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Yifeng Li
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Rui Cui
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Lin Shen
- Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| | - Junfang Xian
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, P.R. China
| |
Collapse
|
4
|
Aslani F, Khorrami-Nejad M, Aghazadeh Amiri M, Hashemian H, Askarizadeh F, Khosravi B. Characteristics of Posterior Corneal Astigmatism in Different Stages of Keratoconus. J Ophthalmic Vis Res 2018; 13:3-9. [PMID: 29403582 PMCID: PMC5782453 DOI: 10.4103/jovr.jovr_217_16] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Purpose To evaluate the magnitudes and axis orientation of anterior corneal astigmatism (ACA) and posterior corneal astigmatism (PCA), the ratio of ACA to PCA, and the correlation between ACA and PCA in the different stages of keratoconus (KCN). Methods This retrospective case series comprised 161 eyes of 161 patients with KCN (104 men, 57 women; mean age, 22.35 ± 6.10 years). The participants were divided into four subgroups according to the Amsler-Krumeich classification. A Scheimpflug imaging system was used to measure the magnitude and axis orientation of ACA and PCA. The posterior-anterior corneal astigmatism ratio was also calculated. The results were compared among different subgroups. Results The average amounts of anterior, posterior, and total corneal astigmatism were 4.08 ± 2.21 diopters (D), 0.86 ± 0.46 D, and 3.50 ± 1.94 D, respectively. With-the-rule, against-the-rule, and oblique astigmatisms of the posterior surface of the cornea were found in 61 eyes (37.9%), 67 eyes (41.6%), and 33 eyes (20.5%), respectively; corresponding figures in the anterior corneal surface were 55 eyes (32.4%), 56 eyes (34.8%), and 50 eyes (31.1%), respectively. A strong correlation (P ≤ 0.001, r = 0.839) was found between ACA and PCA in the different stages of KCN; the correlation was weaker in eyes with grade 3 (P ≤ 0.001, r = 0.711) and grade 4 (P ≤ 0.001, r = 0.717) KCN. The maximum posterior-anterior corneal astigmatism ratio (PCA/ACA, 0.246) was found in patients with stage 1 KCN. Conclusion Corneal astigmatism in anterior surface was more affected than posterior surface by increasing in the KCN severity, although PCA was more affected than ACA in an early stage of KCN.
Collapse
Affiliation(s)
- Fereshteh Aslani
- Department of Optometry, Faculty of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Masoud Khorrami-Nejad
- Department of Optometry, Faculty of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad Aghazadeh Amiri
- Department of Optometry, Faculty of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hesam Hashemian
- Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | - Farshad Askarizadeh
- Department of Optometry, Faculty of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Bahram Khosravi
- Department of Optometry, Faculty of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
5
|
Ocular, corneal, and internal aberrations in eyes with keratoconus, forme fruste keratoconus, and healthy eyes. Int Ophthalmol 2017. [DOI: 10.1007/s10792-017-0620-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
6
|
Aghazadeh Amiri M, Hashemi H, Ramin S, Yekta A, Taheri A, Nabovati P, Khabazkhoob M. Corneal thickness measurements with Scheimpflug and slit scanning imaging techniques in keratoconus. J Curr Ophthalmol 2016; 29:23-27. [PMID: 28367522 PMCID: PMC5362393 DOI: 10.1016/j.joco.2016.09.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Revised: 09/14/2016] [Accepted: 09/18/2016] [Indexed: 10/25/2022] Open
Abstract
PURPOSE To determine the repeatability of corneal thickness measurements with Scheimpflug (Pentacam) and slit scanning (Orbscan) imaging techniques in different grades of keratoconus. METHODS This study was conducted as a cross-sectional research. Imaging with Orbscan and Pentacam was performed on patients with different grades of keratoconus. With each device, 3 measurements were taken at 10 min intervals. Repeatability indices in different grades of keratoconus were calculated for each device. RESULTS Seventy-four eyes of 42 keratoconus patients were enrolled. Repeatability index (RI) of central corneal thickness (CCT) measurements in keratoconus grade 1, 2, and 3, were 12.8, 9.9, and 24.2 with Pentacam, and 23.6, 26.3, and 59.3 with Orbscan, respectively. For the thinnest point, these figures were 9.6, 8.0, and 35.7 with Pentacam and 19.5, 16.6, and 26.8 with Orbscan, respectively. The 95% limit of agreement (LOA) between Pentacam and Orbscan in measuring CCT and thinnest point in grade 1 were -25.5-47.7 mic and -33.3-32.8 mic, respectively. These results for grade 2 were -9.8-50.6 mic and -26.2-43.7 mic, respectively. In grade 3, 95% LoA were -20-64.6 mic and -31.4-60.5 mic, respectively. CONCLUSIONS The results of this study showed that although repeated measurements of the CCT with Orbscan and Pentacam are strongly correlated, repeatability values of CCT measurements significantly decrease at more advanced grades of keratoconus. In all keratoconus grades, repeatability of CCT measurements was better with Pentacam than Orbscan. These findings indicate that corneal thickness readings have less validity in patients with advanced keratoconus.
Collapse
Affiliation(s)
- Mohammad Aghazadeh Amiri
- Department of Optometry, Faculty of Rehabilitation Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hassan Hashemi
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran; Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Shahroukh Ramin
- Department of Optometry, Faculty of Rehabilitation Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Abbasali Yekta
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Azadeh Taheri
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| | - Payam Nabovati
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Mehdi Khabazkhoob
- Department of Medical Surgical Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| |
Collapse
|
7
|
Abstract
To diagnose keratoconus at its earliest stage is meaningful in order to avoid refractive surgery in the eye, which may lead to further damage in the abnormal cornea structure and consequently cause iatrogenic ectasia. In this article, the following aspects of detecting earliest stage of keratoconus were reviewed: 1) nomenclature of the earliest forms of keratoconus; 2) diagnosis of keratoconus using curvature-based topography (also known as Placido-based topography, ie, videokeratography) as a traditional method and elevation-based topography as a new method which has gained popularity in recent years; and 3) other methods analyzing keratoconus cornea like corneal biomechanics and wavefront sensing. Elevation-based topography using either Scheimpflug imaging techniques or slit-scanning imaging techniques has shown to be advantageous over the curvature-based topography in detecting keratoconus at its earliest stage. Posterior elevation of the cornea is notified to enhance the sensitivity and specificity of detection if used along with the measurements of anterior surface of the cornea. Cornea biomechanics analysis and wavefront sensing also revealed differences between normal eyes and keratoconic eyes in their earliest stage. Combining the latest technology and the traditional techniques will be the future trend to improve early diagnosis of keratoconus.
Collapse
Affiliation(s)
- Yue Shi
- Doheny Eye Institute, Department of Ophthalmology, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, CA, USA,
| |
Collapse
|