Şeker O, Kamburoğlu K, Şahin C, Eratam N, Çakmak EE, Sönmez G, Özen D. In vitro comparison of high-definition US, CBCT and periapical radiography in the diagnosis of proximal and recurrent caries. Dentomaxillofac Radiol 2021; 50:20210026. [PMID: 33979235 DOI: 10.1259/dmfr.20210026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To assess the in vitro performance of high-definition (HD) US, CBCT and periapical radiography for the visibility of proximal and recurrent caries in teeth with and without restoration. METHODS A total of 240 molar teeth were divided into eight groups each comprised of 30 teeth. Control groups consisted of teeth without caries (Group 1-4; N = 120), whereas diseased groups consisted of teeth with proximal caries (Group 5-8; N = 120 teeth). Finally, a total of four image sets were obtained as follows: i) PSP periapical radiography, ii) CBCT 0.075 mm voxel size, iii) CBCT 0.2 mm voxel size and iv) HD US images. The image sets were viewed separately by four observers by using a 5-point confidence scale. Intraclass correlation coefficients were calculated. The areas under the ROC curves were compared using chi-square tests. Significance level was set at α = 0.05. RESULTS Intraobserver agreement for both readings for the four observers ranged between 0.848 and 0.988 for CBCT (0.075 mm) images; 0.658 and 0.952 for CBCT (0.2 mm) images; 0.555 and 0.810 for periapical images; 0.427 and 0.676 for US images. Highest AUC values were found for CBCT (0.075 mm) images and lowest for US images. Statistically significant differences were found among CBCT (0.075 mm) images and US images (p < 0.001), CBCT (0.2 mm) images and US images (p < 0.001) and periapical images and US images (p < 0.001) for the detection of proximal caries. CONCLUSION Periapical and CBCT images outperformed HD US imaging in the detection of proximal dental caries.
Collapse
Affiliation(s)
- Oya Şeker
- Restorative Dentistry Department, Faculty of Dentistry, Mustafa Kemal University, Hatay, Turkey
| | - Kıvanç Kamburoğlu
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Cihan Şahin
- Restorative Dentistry Department, Faculty of Dentistry, Mustafa Kemal University, Hatay, Turkey
| | - Nejlan Eratam
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Esra Ece Çakmak
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Gül Sönmez
- Dentistomo Private Diagnostic Imaging Center, Ankara, Turkey
| | - Doğukan Özen
- Department of Biostatistics, Faculty of Veterinary Medicine, Ankara University, Ankara, Turkey
| |
Collapse
|
2
|
Erzurumlu ZU, Sagirkaya CE, Erzurumlu K. Evaluation of radiopacities of CAD/CAM restorative materials and resin cements by digital radiography. Clin Oral Investig 2021; 25:5735-5741. [PMID: 33704572 DOI: 10.1007/s00784-021-03875-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 03/04/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVE This study aims to compare the radiopacities of computer-aided design/computer-aided manufacture (CAD/CAM) blocks and the adhesive cements used for their bonding. MATERIALS AND METHODS 1 ± 0.2 mm thick specimens were obtained from six different CAD/CAM blocks (Incoris TZI, IPS e.max CAD, Vita Mark II, Cerasmart, Vita Enamic, and Vita Suprinity), four different adhesive resin cements (Panavia F2.0, Variolink Esthetic DC, RelyX Unicem Aplicap, G-CEM LinkAce), and a tooth. Radiographs of the specimens from each group, a tooth section, and an aluminum (Al) step-wedge were acquired. The radiopacity values of the materials were calculated as equivalents of Al thickness using the gray level values. The data were statistically analyzed using one-way ANOVA and Tukey HSD tests. RESULTS All the materials except Cerasmart and Vita Enamic had significantly higher radiopacity values than dentin (p < 0.05). Of the assessed blocks, the highest radiopacity value was observed in Incoris TZI, and the lowest radiopacity value was observed in Vita Enamic. Variolink Esthetic DC and RelyX Unicem Aplicap showed significantly higher radiopacity (p < 0.05) than the other adhesive cements, including enamel and dentin. CONCLUSIONS In this study, the majority of the CAD/CAM materials and all the adhesive resin cements were found to have sufficient radiopacity for prosthetic restorations according to the criteria set by the International Organization for Standardization (ISO). CLINICAL RELEVANCE From a clinical and biological point of view, materials should be chosen according to their radiopacity and other properties, such as biocompatibility and esthetics. If the selected restorative CAD/CAM blocks have a radiopacity value less than or equal to dentin, cements with higher radiopacity values are recommended to facilitate radiological diagnoses for periphery and interface of restorations.
Collapse
Affiliation(s)
- Zerrin Unal Erzurumlu
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ordu University, Ordu, Turkey.
| | | | - Kerem Erzurumlu
- Department of Computer Programming, Vocational School of Technical Sciences, Ordu University, Ordu, Turkey
| |
Collapse
|
3
|
Radiopacity and mechanical properties of dental adhesives with strontium hydroxyapatite nanofillers. J Mech Behav Biomed Mater 2020; 101:103447. [DOI: 10.1016/j.jmbbm.2019.103447] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 09/23/2019] [Accepted: 09/23/2019] [Indexed: 01/08/2023]
|
4
|
Junqueira RB, Carvalho RF, Yamamoto FAGF, Almeida SM, Verner FS. Evaluation of Radiopacity of Luting Cements Submitted to Different Aging Procedures. J Prosthodont 2018; 27:853-859. [PMID: 30320422 DOI: 10.1111/jopr.12989] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/08/2018] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To evaluate the radiopacity of luting cements submitted to different aging procedures. MATERIALS AND METHODS Twenty discs (1 × 4 mm) of each of the following cements were prepared: zinc phosphate, RelyX Luting 2, Variolink 2, AllCem, RelyX U200, Multilink, Panavia F2.0, and RelyX ARC. Then, they were randomly divided into two groups (n = 10/group), according to the aging procedure: thermal cycling group and water storage group. Before and after aging procedures, specimens were x-rayed with an aluminum step-wedge (11 steps, 1 mm thick each) and three dental slices (1 mm thick). The radiopacity was evaluated by means of optical density, which was measured using ImageJ software. The values were converted into millimeters of aluminum with a logistic regression calibration curve. The data were analyzed by one-way ANOVA and Tukey post-hoc test (α = 0.05). RESULTS In the thermal cycling group, RelyX Luting 2, RelyX U200, and Panavia F2.0 showed a statistically significant reduction in radiopacity (p < 0.05). In the water storage group, all cements showed a significant reduction in radiopacity (p < 0.05), and RelyX Luting 2 and Panavia F2.0 performed below the desired ISO 4049 standard. CONCLUSIONS The radiopacity of luting cements can decrease after aging, especially after 1-year water storage.
Collapse
Affiliation(s)
- Rafael B Junqueira
- Division of Endodontics, Department of Dentistry, Federal University of Juiz de Fora, Campus GV (UFJF-GV), Governador Valadares, Minas Gerais, Brazil
| | - Rodrigo F Carvalho
- Division of Prosthodontics, Department of Dentistry, Federal University of Juiz de Fora, Campus GV (UFJF-GV), Governador Valadares, Minas Gerais, Brazil
| | - Felipe A G F Yamamoto
- Hospital Maternidade Therezinha de Jesus-HMTJ/JF and Suprema - Faculdade Ciências Médicas e da Saúde Juiz de Fora (SUPREMA), Juiz de Fora, Minas Gerais, Brazil
| | - Solange M Almeida
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Francielle S Verner
- Division of Oral Diagnosis, Department of Dentistry, Federal University of Juiz de Fora, Campus GV (UFJF-GV), Governador Valadares, Minas Gerais, Brazil
| |
Collapse
|
5
|
Signori C, Gimenez T, Mendes FM, Huysmans MCD, Opdam NJ, Cenci MS. Clinical relevance of studies on the visual and radiographic methods for detecting secondary caries lesions – A systematic review. J Dent 2018; 75:22-33. [DOI: 10.1016/j.jdent.2018.05.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 05/22/2018] [Accepted: 05/27/2018] [Indexed: 10/16/2022] Open
|
6
|
An SY, An CH, Choi KS, Huh KH, Yi WJ, Heo MS, Lee SS, Choi SC. Radiopacity of contemporary luting cements using conventional and digital radiography. Imaging Sci Dent 2018; 48:97-101. [PMID: 29963480 PMCID: PMC6015930 DOI: 10.5624/isd.2018.48.2.97] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 03/02/2018] [Accepted: 03/17/2018] [Indexed: 12/01/2022] Open
Abstract
Purpose This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. Materials and Methods Disc specimens (N=24, n=6 per group, ø7 mm×1 mm) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results Multilink (3.44–4.33) showed the highest radiopacity, followed by U-cem (1.81–2.88), Panavia F 2.0 (1.51–2.69), and Duolink (1.48–2.59). The R2 values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. Conclusion The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.
Collapse
Affiliation(s)
- Seo-Young An
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyungpook National University, Daegu, Korea
| | - Chang-Hyeon An
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyungpook National University, Daegu, Korea
| | - Karp-Sik Choi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyungpook National University, Daegu, Korea
| | - Kyung-Hoe Huh
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Seoul National University, Seoul, Korea
| | - Won-Jin Yi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Seoul National University, Seoul, Korea
| | - Min-Suk Heo
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Seoul National University, Seoul, Korea
| | - Sam-Sun Lee
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Seoul National University, Seoul, Korea
| | - Soon-Chul Choi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Seoul National University, Seoul, Korea
| |
Collapse
|
7
|
Ghoncheh Z, Zonouzy Z, Kiomarsi N, Kharazifar MJ, Chiniforush N. In Vitro Comparison of Diagnostic Accuracy of DIAGNOdent and Digital Radiography for Detection of Secondary Proximal Caries Adjacent to Composite Restorations. J Lasers Med Sci 2017; 8:172-176. [PMID: 29071022 DOI: 10.15171/jlms.2017.31] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: Early detection of secondary proximal caries is critical for the preservation of tooth vitality. This study sought to assess and compare the diagnostic accuracy of DIAGNOdent and digital radiography for detection of secondary proximal caries adjacent to composite restorations. Methods: Sixty extracted molars including 30 teeth with carious lesions and 30 sound teeth were randomly selected. Class II cavities were prepared in all teeth and carious dentin was intentionally left in the gingival floor of cavities in 30 carious teeth. All cavities were restored with composite resin. The teeth were mounted in wax blocks (three teeth per block) and examined for caries using (DIAGNOdent kaVo Dental, Biberach, Germany). Digital radiographs using DIGORA photostimulable phosphor (PSP) plates (Soredex Corporation, Helsinki, Finland) were obtained from all teeth using the parallel technique and were evaluated by 4 observers. Repeated measure analysis of variance (ANOVA) was applied to calculate sensitivity and specificity values of the two diagnostic techniques. Receiver operating characteristic (ROC) curve was plotted for DIAGNOdent results and based on that, the cutoff points were determined. Results: The sensitivity and specificity values at the cut-off point of 10.5 were 0.622±0.038 and 0.822±0.077 for DIAGNOdent and 0.591±0.093 and 0.891±0.083 for digital radiography, respectively. The area under the ROC curve was 0.7 for DIAGNOdent. Weighted kappa revealed moderate to almost perfect intra-observer agreement (0.46-0.99). Intraclass correlation coefficient (ICC) for DIAGNOdent was calculated to be 0.88. Conclusion: No statistically significant difference was noted in diagnostic accuracy of DIAGNOdent and digital radiography for detection of secondary proximal caries adjacent to composite restorations. Thus, DIAGNOdent may be used as an adjunct diagnostic tool for detection of secondary proximal caries beneath composite restorations.
Collapse
Affiliation(s)
- Zahra Ghoncheh
- Department of Oral and Maxillofacial Radiology, Dental faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran
| | - Zahra Zonouzy
- Tehran University of Medical Sciences, International Campus, Tehran, Iran
| | - Nazanin Kiomarsi
- Department of Operative Dentistry, Dental Faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran
| | | | - Nasim Chiniforush
- Laser Research Center of Dentistry (LRCD), Dental Research Institute, Tehran University of Medical Sciences, International Campus, Tehran, Iran
| |
Collapse
|
8
|
Hosney S, Abouelseoud HK, El-Mowafy O. Radiopacity of Resin Cements Using Digital Radiography. J ESTHET RESTOR DENT 2017; 29:215-221. [PMID: 28417581 DOI: 10.1111/jerd.12288] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
STATEMENT OF PROBLEM Monitoring performance of glass-ceramic based indirect restorations using radiographic imaging might be difficult due to their low radiopacity. Therefore, materials used for their cementation must possess adequate radiopacity. PURPOSE This study determined radiopacity of a group of resin-cements used for adhesive-cementation of glass-ceramic-based restorations using digital radiography. METHODS Two specimens were prepared from a group of resin cements (VariolinkII-opaque, VariolinkII-opaque (base), VariolinkII-Transparent, VariolinkII-Transparent (base), Nexus, RelyX Unicem, RelyX ultimate, Duolink, Monocem and Resinomer) and longitudinal sections of same thickness were obtained from molar and premolar. Specimens were assigned to two groups one had molar section with 10 specimens whereas other had premolar with remaining 10 specimens. Each group was placed on digital radiograph sensor (Schick CDR, size 2) together with aluminum step-wedge. Sensor was exposed to X-ray using standard technique. Two images were obtained for each group. Pixel measurements were made using NIH Image-J software. Mean pixel measurements were converted into aluminum thickness equivalents. Data were statistically-analyzed using one-way ANOVA and Tukey's tests. RESULTS ANOVA revealed significant difference in mean pixel values among cements (p < 0.001). VariolinkII-opaque showed highest mean aluminum equivalent (4.6 mm Al/1 mm) followed by VariolinkII-opaque-Base (4.5 mm Al/1 mm), VariolinkII-transparent (4.45 mm Al/1 mm), VariolinkII-transparent-Base (4.45 mm Al/1 mm), Nexus (2.95 mm Al/1 mm), Duolink (2.7 mm Al/1 mm), RelyX Unicem (2.2 mm Al/1 mm) and finally RelyX ultimate (2 mm Al/1 mm). All cements had mean radiopacity values higher than that of enamel whereas Monocem (1.25 mm Al/1 mm) and Resinomer (1.2 mm Al/1 mm) had means between those of enamel and dentin. CONCLUSIONS All tested resin-cements showed radiopacity values higher than that of dentin which is adequate for diagnostic purposes according to ISO recommendation. CLINICAL SIGNIFICANCE The use of resin cement with adequate radiopacity for adhesive cementation of glass-ceramic based restorations enables their radiographic monitoring. (J Esthet Restor Dent 29:215-221, 2017).
Collapse
Affiliation(s)
- Sherif Hosney
- Research Associate, Department of Restorative Dentistry, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, M5G1G6, Canada
| | - Hanan K Abouelseoud
- Professor of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, KSA, Saudi Arabia
| | - Omar El-Mowafy
- Professor and Head of Restorative Dentistry, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, M5G1G6, Canada
| |
Collapse
|
9
|
An SY, Lee DH, Lee KB. Radiopacity for Contemporary Luting Cements Using Digital Radiography under Various Exposure Conditions. J Prosthodont 2015; 24:642-6. [PMID: 25865072 DOI: 10.1111/jopr.12288] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/15/2014] [Indexed: 11/27/2022] Open
Abstract
PURPOSE This study examined the radiopacity of contemporary luting cements using direct digital radiography under a range of exposure conditions. MATERIALS AND METHODS Disc specimens (N = 80, n = 10 per group, ø5 mm × 1 mm) were prepared from 8 resin-based luting cements (BisCem Clearfil SA Luting, Duolink, Maxcem Elite Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a charge-coupled device sensor along with an 11-step aluminum step wedge (1.5-mm incremental steps) and 1-mm-thick tooth cut using five tube voltage/exposure time setups (60 kVp, 0.10/0.08 seconds; 70 kVp, 0.10/0.08/0.06 seconds) at 4 mA and 30 cm. The radiopacity of the specimens was compared with that of the aluminum step wedge and human enamel and dentin using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/). A linear regression model for the aluminum step wedge was constructed, and the data were analyzed by ANOVA and Duncan post hoc test. RESULTS Maxcem Elite (5.142 to 5.441) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.731 to 3.396) and V-link (2.763 to 3.103). The radiopacity of Panavia F 2.0 (2.025 to 2.429), BisCem (1.825 to 2.218), Clearfil SA Luting (1.692 to 2.145), Duolink (1.707 to 1.993), and RelyX Unicem Clicker (1.586 to 1.979) were between enamel (2.117 to 2.330) and dentin (1.302 to 1.685). The radiopacity of 70 kVp conditions was higher than that of the 60 kVp conditions. CONCLUSIONS The radiopacities of the tested luting materials were greater than those of dentin or aluminum, satisfying the criteria of the International Organization for Standardization, and they differed significantly from each other in the exposure setups.
Collapse
Affiliation(s)
- Seo-Young An
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyungpook National University, Daegu, Korea
| | - Du-Hyeong Lee
- Department of Prosthodontics, School of Dentistry and Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Korea
| | - Kyu-Bok Lee
- Department of Prosthodontics, School of Dentistry and Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Korea
| |
Collapse
|
10
|
Malka VB, Hochscheidt GL, Larentis NL, Grecca FS, Fontanella VRC, Kopper PMP. A new in vitro method to evaluate radio-opacity of endodontic sealers. Dentomaxillofac Radiol 2015; 44:20140422. [PMID: 25651275 DOI: 10.1259/dmfr.20140422] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To evaluate a new method for assessing the radio-opacity of endodontic sealers and to compare radio-opacity values with a well-established standard method. METHODS The sealers evaluated in this study were AH Plus(®) (Dentsply DeTrey GmbH, Konstanz, Germany), Endo CPM Sealer (EGEO SRL, Buenos Aires, Argentina) and MTA Fillapex(®) (Angelus Dental Products Industry S/A, Londrina, Parana, Brazil). Two methods were used to evaluate radio-opacity: (D) standard discs and (S) a tissue simulator. For (D), ten standard discs were prepared for each sealer and were radiographed using Digora(®) phosphor storage plates (Soredex; Orion Corporation, Helsinki, Finland), alongside an aluminium stepwedge. For (S), polyethylene tubes filled with sealer (n = 10 for each) were radiographed inside the simulator as described. The digital images were analysed using Adobe Photoshop(®) software v. 10.0 (Adobe Systems, San Jose, CA). To compare the radio-opacity among the sealers, the data were analysed by ANOVA and Tukey's test, and to compare methods, they were analysed by the Mann-Whitney U test. To compare the data obtained from dentin and sealers in method (S), Student's paired t-test was used (=0.05). RESULTS In both methods, the sealers showed significant differences, according to the following decreasing order: AH Plus, MTA Fillapex and Endo CPM. In (D), MTA Fillapex and Endo CPM showed less radio-opacity than aluminium. For all of the materials, the radio-opacity was higher in (S) than in (D). Compared with dentin, all of the materials were more radio-opaque. CONCLUSIONS The comparison of the two assessment methods for sealer radio-opacity testing validated the use of a tissue simulator block.
Collapse
Affiliation(s)
- V B Malka
- 1 Department of Conservative Dentistry, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | | | | | | | | | | |
Collapse
|
11
|
de Moraes Porto ICC, Honório NC, Amorim DAN, de Melo Franco AV, Penteado LAM, Parolia A. Comparative radiopacity of six current adhesive systems. J Conserv Dent 2014; 17:65-9. [PMID: 24554865 PMCID: PMC3915390 DOI: 10.4103/0972-0707.124151] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Revised: 09/11/2013] [Accepted: 09/24/2013] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND The radiopacity of contemporary adhesive systems has been mentioned as the indication for replacement of restorations due to misinterpretation of radiographic images. AIMS This study aimed to evaluate the radiopacity of contemporary bonding agents and to compare their radiodensities with those of enamel and dentin. METHODS AND MATERIALS To measure the radiopacity, eight specimens were fabricated from Clearfil SE Bond (CF), Xeno V (XE), Adper SE Bond (ASE), Magic Bond (MB), Single Bond 2 (SB), Scotchbond Multipurpose (SM), and gutta-percha (positive control). The optical densities of enamel, dentin, the bonding agents, gutta-percha, and an aluminium (Al) step wedge were obtained from radiographic images using image analysis software. STATISTICAL ANALYSIS The radiographic density data were analyzed statistically by analysis of variance and Tukey's test (α =0.05). RESULTS Significant differences were found between ASE and all other groups tested and between XE and CF. No statistical difference was observed between the radiodensity of 1 mm of Al and 1 mm of dentin, between 2 mm of Al and enamel, and between 5 mm of Al and gutta-percha. Five of the six adhesive resins had radiopacity values that fell below the value for dentin, whereas the radiopacity of ASE adhesive was greater than that of dentin but below that of enamel. CONCLUSION This investigation demonstrates that only ASE presented a radiopacity within the values of dentin and enamel. CF, XE, MB, SB, and SM adhesives are all radiolucent and require alterations to their composition to facilitate their detection by means of radiographic images.
Collapse
Affiliation(s)
| | - Naira Cândido Honório
- Department of Restorative Dentistry, Cesmac University Center, Maceió, Alagoas, Brazil
| | | | | | | | - Abhishek Parolia
- Faculty of Dentistry, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia
| |
Collapse
|