1
|
Ahuja BM, Pawashe KG, Sanyal PK, Al-Qarni MA, Alqahtani NM, Alqahtani SM, Ahmed AR, Abdul Khader M, Elmahdi AE, Chaturvedi S. Assessment of dimensional stability of novel VPES impression material at different time intervals with standard disinfectants. BMC Oral Health 2024; 24:579. [PMID: 38762747 PMCID: PMC11102608 DOI: 10.1186/s12903-024-04323-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 05/02/2024] [Indexed: 05/20/2024] Open
Abstract
BACKGROUND Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.
Collapse
Affiliation(s)
- Bhavna M Ahuja
- Department of Prosthodontics and Crown & Bridge, Terna Dental College, Nerul, Navi Mumbai, Maharashtra, 400706, India
| | - Karuna G Pawashe
- Department of Prosthodontics and Crown & Bridge, School of Dental Sciences, Krishna Vishwa Vidyapeeth, Deemed to be University, Karad, Satara, Maharashtra, India
| | - Pronob Kumar Sanyal
- Department of Prosthodontics and Crown & Bridge, School of Dental Sciences, Krishna Vishwa Vidyapeeth, Deemed to be University, Karad, Satara, Maharashtra, India
| | - Mohammed A Al-Qarni
- Department of Restorative Dental Sciences College of Dentistry, King Khalid University, P.O.Box 3263, 61471, Abha, Saudi Arabia
| | - Nasser M Alqahtani
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saeed M Alqahtani
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdul Razzaq Ahmed
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Mohasin Abdul Khader
- Division of Periodontics, Department of Periodontics and Community Dental Sciences (PCS), College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Asim Elsir Elmahdi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saurabh Chaturvedi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
- Department of Dental Research Cell, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Sant-Tukaram Nagar, Pimpri, Pune, 411018, India.
| |
Collapse
|
2
|
Joshi S, Madhav VNV, Saini RS, Gurumurthy V, Alshadidi AAF, Aldosari LIN, Okshah A, Mosaddad SA, Heboyan A. Evaluation of the effect of chemical disinfection and ultraviolet disinfection on the dimensional stability of polyether impression material: an in-vitro study. BMC Oral Health 2024; 24:458. [PMID: 38622548 PMCID: PMC11020824 DOI: 10.1186/s12903-024-04188-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 03/26/2024] [Indexed: 04/17/2024] Open
Abstract
BACKGROUND Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.
Collapse
Affiliation(s)
- Snehal Joshi
- Department of Prosthodontics, SMBT Dental College and Hospital, Sangamner, 422608, Maharashtra, India
| | - V N V Madhav
- Department of Prosthodontics, YCMM & RDF's Dental College and Hospital, Ahmednagar, India
| | - Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | | | | | - Abdulmajeed Okshah
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Seyed Ali Mosaddad
- Department of Research Analytics, Saveetha Institute of Medical and Technical Sciences, Saveetha Dental College and Hospitals, Saveetha University, Chennai, India.
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Qasr-e-Dasht Street, Shiraz, Iran.
| | - Artak Heboyan
- Department of Research Analytics, Saveetha Institute of Medical and Technical Sciences, Saveetha Dental College and Hospitals, Saveetha University, Chennai, India.
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, Yerevan, 0025, Armenia.
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
3
|
Saini RS, Alshadidi AAF, Hassan SAB, Aldosari LIN, Mosaddad SA, Heboyan A. Properties of a novel composite elastomeric polymer vinyl polyether siloxane in comparison to its parent materials: a systemic review and meta-analysis. BMC Oral Health 2024; 24:54. [PMID: 38195442 PMCID: PMC10775522 DOI: 10.1186/s12903-023-03830-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 12/26/2023] [Indexed: 01/11/2024] Open
Abstract
BACKGROUND The effectiveness of newly developed elastomeric polymer hybrid siloxane (PVES), which combines the properties of polyethylene (PE) and polyvinyl siloxane (PVS) elastomers, has been a subject of interest in recent studies. This study aimed to assess the physical properties of hybrid PVES materials by analyzing existing data from recent studies on this topic. METHODS A systematic literature search was conducted to retrieve peer-reviewed articles published up to February 5, 2023. The population, intervention, comparison, and pertinent outcomes were specified under the PICO framework. The primary data analysis was performed in Microsoft Excel, while statistical analysis used Meta-Essentials. RESULTS Of the 1152 articles assessed, 14 met the inclusion criteria. The meta-analysis of the selected studies indicated that polyether (PE) and polyvinyl siloxane (PVS) were highly correlated (two-tailed p-values of 0.000 and 0.001, respectively) with the improved tensile strength of vinyl polyether siloxane (PVES) with a significantly positive effect size. Similarly, the hydrophilic characteristics of PVES were significantly improved compared to those of PE and PVS. PE was a significant contributor to the hydrophilic characteristics of PVES, with a two-tailed p-value of 0.000. The effect size was highly positive for hydrophilicity but showed high heterogeneity. It was also observed that the dimensional accuracy of PVES was comparable to those of PE and PVS, with no statistically significant differences among the three materials. CONCLUSIONS PVES showed promising features, with improved tensile strength and hydrophilic characteristics compared to those of PE and PVS.
Collapse
Affiliation(s)
- Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | - Saeed Awod Bin Hassan
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | | - Seyed Ali Mosaddad
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Artak Heboyan
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, 0025, Yerevan, Armenia.
| |
Collapse
|
4
|
Effects of Various Disinfection Methods on the Material Properties of Silicone Dental Impressions of Different Types and Viscosities. Int J Mol Sci 2022; 23:ijms231810859. [PMID: 36142778 PMCID: PMC9505442 DOI: 10.3390/ijms231810859] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 09/06/2022] [Accepted: 09/14/2022] [Indexed: 11/16/2022] Open
Abstract
There is an ongoing search for novel disinfection techniques that are not only effective, cheap, and convenient, but that also do not have adverse effects on the properties of dental impressions. We compared the effects of various methods (UVC, gaseous ozone, commercial solution, and spray) on the dimensional change, tensile strength, and hardness of silicone impressions. Moreover, as a secondary aim, we performed a statistical comparison of the properties of nondisinfected addition (Panasil Putty Soft, Panasil monophase Medium, Panasil initial contact Light) and condensation silicones (Zetaplus Putty and Oranwash L), as well as a comparison of materials of various viscosities (putty, medium-bodied, and light-bodied). Our results revealed that addition silicones had higher dimensional stability, tensile strength, and Shore A hardness compared to condensation silicones. Both traditional (immersion and spraying) and alternative methods of disinfection (UVC and ozone) had no significant impact on the tensile properties and dimensional stability of the studied silicones; however, they significantly affected the hardness, particularly of Oranwash L. Our study demonstrated that, similarly to standard liquid disinfectants, both UVC and ozone do not strongly affect the material properties of most silicones. However, before recommendation, their usefulness for each individual material should be thoroughly evaluated.
Collapse
|
5
|
Rencber A, Altintas E. Effects chemical disinfectants on surface roughness of conventional impression materials used for dental prosthetic procedures. Niger J Clin Pract 2022; 25:1484-1489. [DOI: 10.4103/njcp.njcp_1920_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
6
|
R. Mohd N, Omar RA, Etajuri EA. Dimensional Stability of Elastomeric Impression Material After Disinfection Via Immersion and Microwave Irradiation. Open Dent J 2021. [DOI: 10.2174/1874210602115010658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Aims:
This study aimed to evaluate and compare the dimensional stability of two elastomeric impression materials, namely polyvinyl siloxane (PVS) and vinyl siloxanether (VSE), subjected to chemical immersion and microwave irradiation for disinfection.
Materials and Methods:
Sixty discs of PVS and VSE impression materials each were prepared using a stainless-steel test die and ring in accordance with ANSI/ADA Specification No. 19. Twenty discs of each impression material were disinfected by chemical immersion for 10 min; another 20 discs were subjected to dry microwave irradiation for 3 min. The other 20 discs served as a control group. Dimensional stability measurements were then performed using an image analyzer at 20× magnification. The data were analyzed by one-way analysis of variance (α=0.05) and Bonferroni (post hoc) test for multiple comparisons to detect significant differences between the groups.
Results:
When subjected to microwave irradiation, both PVS and VSE showed dimensional changes, but the changes were within the limit of 1.5% set by ANSI/ADA (P<0.00). VSE showed markedly better results than PVS for both disinfection methods. The immersion disinfection method resulted in a higher average percentage of linear dimensional changes than both the microwave irradiation and the control for VSE and PVS impression materials.
Conclusion:
VSE exhibited excellent dimensional stability than PVS under both chemical immersion and microwave irradiation. Microwave irradiation using conventional microwave ovens can be used in clinical settings as an alternative to other disinfection techniques because the dimensional changes of the elastomeric impression materials subjected to microwave irradiation have been observed to be within the clinically acceptable limit set by the ANSI/ADA standard.
Collapse
|
7
|
Sabetkish S, Kajbafzadeh AM. The Three-Dimensional Structure of Tissues and Organs: A Scanning Electron Microscopic Atlas for Research and Education. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1345:253-259. [PMID: 34582028 DOI: 10.1007/978-3-030-82735-9_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Shabnam Sabetkish
- Pediatric Urology and Regenerative Medicine Research Center, Section of Tissue Engineering and Stem Cells Therapy, Children's Medical Center, Tehran University of Medical Sciences, No. 62, Dr. Gharib's Street, Keshavarz Boulevard, 1419433151, Tehran, Iran
| | - Abdol-Mohammad Kajbafzadeh
- Pediatric Urology and Regenerative Medicine Research Center, Section of Tissue Engineering and Stem Cells Therapy, Children's Medical Center, Tehran University of Medical Sciences, No. 62, Dr. Gharib's Street, Keshavarz Boulevard, 1419433151, Tehran, Iran.
| |
Collapse
|