1
|
Bourgi R, Hardan L, Cuevas-Suárez CE, Scavello F, Mancino D, Kharouf N, Haikel Y. The Use of Warm Air for Solvent Evaporation in Adhesive Dentistry: A Meta-Analysis of In Vitro Studies. J Funct Biomater 2023; 14:jfb14050285. [PMID: 37233396 DOI: 10.3390/jfb14050285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 05/15/2023] [Accepted: 05/17/2023] [Indexed: 05/27/2023] Open
Abstract
Any excess solvent from dental adhesive systems must be eliminated prior to material photopolymerization. For this purpose, numerous approaches have been proposed, including the use of a warm air stream. This study aimed to investigate the effect of different temperatures of warm air blowing used for solvent evaporation on the bond strength of resin-based materials to dental and nondental substrates. Two different reviewers screened the literature in diverse electronic databases. In vitro studies recording the effect of warm air blowing to evaporate solvents of adhesive systems on the bond strength of resin-based materials to direct and indirect substrates were included. A total of 6626 articles were retrieved from all databases. From this, 28 articles were included in the qualitative analysis, and 27 remained for the quantitative analysis. The results of the meta-analysis for etch-and-rinse adhesives revealed that the use of warm air for solvent evaporation was statistically significantly higher (p = 0.005). For self-etch adhesives and silane-based materials, this effect was observed too (p < 0.001). The use of a warm air stream for solvent evaporation enhanced the bonding performance of alcohol-/water-based adhesive systems for dentin. This effect seems to be similar when a silane coupling agent is submitted to a heat treatment before the cementation of a glass-based ceramic.
Collapse
Affiliation(s)
- Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
| | - Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
| | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca 42160, Mexico
| | | | - Davide Mancino
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, University of Strasbourg, 67000 Strasbourg, France
- Pôle de Médecine et Chirurgie Bucco-Dentaire, Hôpital Civil, Hôpitaux Universitaire de Strasbourg, 67000 Strasbourg, France
| | - Naji Kharouf
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, University of Strasbourg, 67000 Strasbourg, France
| | - Youssef Haikel
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, University of Strasbourg, 67000 Strasbourg, France
- Pôle de Médecine et Chirurgie Bucco-Dentaire, Hôpital Civil, Hôpitaux Universitaire de Strasbourg, 67000 Strasbourg, France
| |
Collapse
|
2
|
Araújo-Neto VG, Moreira MM, Ñaupari-Villasante R, De Paula DM, Medeiros S, Loguercio AD, Feitosa VP. Nanofiller Particles and Bonding Durability, Water Sorption, and Solubility of Universal Adhesives. Oper Dent 2021; 46:690-697. [PMID: 35507899 DOI: 10.2341/20-239-l] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/27/2021] [Indexed: 11/23/2022]
Abstract
The aim of this study was to evaluate the influence of nanofiller particles in simplified universal adhesive on the long-term microtensile bond strength and silver nitrate up-take, as well as water sorption and solubility. Commercial adhesives Ambar Universal (FGM) in nanofilled-containing version (filled) and same lot without fillers (unfilled) were donated and applied by means of etch-and-rinse strategy. Microtensile bond strength was surveyed after 24-hours or 1-year water storage. Silver nitrate uptake was assayed using scanning electron microscopy (SEM). Water sorption and solubility experiments were performed based on ISO 4049:2009. Statistical analysis was performed using two-way ANOVA and Tukey test (p<0.05). The bond strength of both the adhesives were statistically similar at 24 hours (p>0.05), but the filled group attained significant bond strength reduction after aging when compared to initial bond strength (p<0.001). Conversely, unfilled adhesive presented stable adhesion after 1-year storage (p=0.262). Silver nitrate uptake was similar for both adhesives, with little silver impregnation at the hybrid and adhesive layers. Water sorption was higher with filled adhesive compared to the unfilled one (p=0.01). Conversely, solubility was higher in unfilled in comparison to filled one (p=0.008). The presence of nanofillers in universal adhesive achieves higher water sorption and dentin bond degradation, which did not occur in the unfilled adhesive.
Collapse
Affiliation(s)
- V G Araújo-Neto
- *Vitaliano Gomes Araújo-Neto, Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - M M Moreira
- Madiana Magalhães Moreira, DDS, MS, Post-graduation Program in Dentistry, Federal University of Ceará, Fortaleza, Brazil
| | - R Ñaupari-Villasante
- RominaÑaupari-Villasante, DDS, Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | - D M De Paula
- Diego Martins De Paula, DDS, MS, PhD, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - Stcb Medeiros
- Samara Tabata Cavalcante Braga Medeiros, DDS student, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - A D Loguercio
- Alessandro Dourado Loguercio, DDS, MS, PhD, Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | - V P Feitosa
- Victor Pinheiro Feitosa, DDS, MS, PhD, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| |
Collapse
|
3
|
Zimmer R, Leite ML, de Souza Costa CA, Hebling J, Anovazzi G, Klein CA, Hosaka K, Reston ED. Effect of Time and Temperature of Air Jet on the Mechanical and Biological Behavior of a Universal Adhesive System. Oper Dent 2021; 47:87-96. [PMID: 34624102 DOI: 10.2341/20-038-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/05/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To evaluate the influence of heat application on the degree of conversion (DC) of the 3M Single Bond Universal Adhesive System, as well as its transdentinal cytotoxicity and microtensile bond strength to dentin. METHODS Experimental groups were established according to the time and temperature of the air jet: G1: 5 seconds-25°C; G2: 10 seconds-25°C; G3: 20 seconds-25°C; G4: 5 seconds-50°C; G5: 10 seconds-50°C; G6: 20 seconds-50°C. In control group (G7), no treatment was performed. The DC was assessed using the Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) technique. For the transdentinal cytotoxicity test, dentin discs fitted in artificial pulp chambers (APC) received the application of the adhesive system and the air jets. For the microtensile bond strength, healthy molars were restored and submitted to the microtensile test after 24 hours and 6 months, respectively. RESULTS Significant reduction in viability of Mouse Dental Papilla Cell-23 (MDPC-23), which exhibited morphological changes, was observed in all experimental groups compared to control (p<0.05). Although all tested protocols resulted in transdentinal diffusion of 2-hydroxyethyl methacrylate (HEMA), the group G6 presented the highest degree of monomeric conversion and the lowest cytotoxic effect, with higher dentin bond strength values in comparison to group G1 (p<0.05). CONCLUSIONS Applying an air blast at 50°C for 20 seconds increases the DC and microtensile bond strength of the 3M Single Bond Universal Adhesive System to dentin, as well as reduces the transdentinal cytotoxicity of the material to pulp cells.
Collapse
Affiliation(s)
- R Zimmer
- Roberto Zimmer, DDS, MS, Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| | - M L Leite
- Maria Luisa Leite, DDS, MS, PhD, Department of Physiology and Pathology, Araraquara School of Dentistry, São Paulo State University (Unesp), Araraquara, Brazil
| | - C A de Souza Costa
- Carlos Alberto de Souza Costa, DDS, MS, PhD, Department of Physiology and Pathology, Araraquara School of Dentistry, São Paulo State University (Unesp), Araraquara, Brazil
| | - J Hebling
- Josimeri Hebling, DDS, MS, PhD, Department of Orthodontics and Pediatric Dentistry, Araraquara School of Dentistry, São Paulo State University (Unesp), Araraquara, Brazil
| | - G Anovazzi
- Giovana Anovazzi, DDS, MS, PhD, Department of Orthodontics and Pediatric Dentistry, Araraquara School of Dentistry, São Paulo State University (Unesp), Araraquara, Brazil
| | - C A Klein
- Celso Afonso Klein-Junior, DDS, MS, PhD, Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| | - K Hosaka
- Keiichi Hosaka, DDS, MS, PhD, Department of Cariology and Operative Dentistry,Graduate School of Medical and Dental Sciences,Tokyo Medical and Dental University, Tokyo, Japan
| | - E D Reston
- *Eduardo Galia Reston, DDS, MSD, PhD, Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| |
Collapse
|