1
|
Mikulewicz M, Chojnacka K, Raszewski Z. Comparison of Mechanical Properties of Three Tissue Conditioners: An Evaluation In Vitro Study. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1359. [PMID: 37629649 PMCID: PMC10456693 DOI: 10.3390/medicina59081359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 07/14/2023] [Accepted: 07/20/2023] [Indexed: 08/27/2023]
Abstract
Introduction: Tissue conditioners have been widely used in various clinical applications in dentistry, such as treating inflamed alveolar ridges, temporarily relining partial and complete dentures, and the acquisition of functional impressions for denture fabrication. This study aimed to investigate the mechanical properties of the most prevalent tissue conditioner materials on the market, including Tissue Conditioners (TC), Visco Gel (VG), and FITT (F). Materials and Methods: The three tissue conditioners, TC, VG, and F, were assessed based on the parameters mentioned above. The following tests were performed based on the ISO 10139-1 and ISO 10139-2 requirements: Shore A hardness, denture plate adhesion, sorption, water solubility, and contraction after 1 and 3 days in water. Additional tests are described in the literature, such as ethanol content and gelling time. The tests were carried out by storing the materials in water at 37 °C for 7 days. Results: The gel times of all tested materials exceeded 5 min (TC = 300 [s], VG = 350 [s]). In vitro, phthalate-free materials exhibited higher dissolution in water after 14 days (VG = -260.78 ± 11.31 µg/mm2) compared to F (-76.12 ± 7.11 µg/mm2) and experienced faster hardening when stored in distilled water (F = 33.4 ± 0.30 Sh. A, VG = 59.2 ± 0.60 Sh. A). They also showed greater contractions. The connection of all materials to the prosthesis plate was consistent at 0.11 MPa. The highest counterbalance after 3 days was observed in TC = 3.53 ± 1.12%. Conclusions: Materials containing plasticizers that are not phthalates have worse mechanical properties than products containing these substances. Since phthalates are not allowed to be used indefinitely in medical devices, additional research is necessary, especially in vivo, to develop safe materials with superior functional properties to newer-generation alternatives. In vitro results often do not agree fully with those of in vivo outcomes.
Collapse
Affiliation(s)
- Marcin Mikulewicz
- Department of Dentofacial Orthopaedics and Orthodontics, Division of Facial Abnormalities, Medical University of Wroclaw, Krakowska 26, 50-425 Wroclaw, Poland;
| | - Katarzyna Chojnacka
- Department of Advanced Material Technologies, Faculty of Chemistry, Wroclaw University of Science and Technology, Smoluchowskiego 25, 50-372 Wroclaw, Poland;
| | | |
Collapse
|
2
|
Bradić-Vasić M, Kostić M, Igić M, Pejčić A, Nikolić L. A release of potentially toxic components from the acrylic resins for soft relining dentures. ACTA STOMATOLOGICA NAISSI 2019. [DOI: 10.5937/asn1979927b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
|
3
|
Gonçalves FP, Alves G, Guimarães VO, Gallito MA, Oliveira F, Scelza MZ. Cytotoxicity Evaluation of Two Bis-Acryl Composite Resins Using Human Gingival Fibroblasts. Braz Dent J 2016; 27:492-496. [PMID: 27982223 DOI: 10.1590/0103-6440201600824] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2016] [Accepted: 06/10/2016] [Indexed: 11/21/2022] Open
Abstract
Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.
Collapse
Affiliation(s)
- Fabiano Palmeira Gonçalves
- Department of Clinical Dentistry, Laboratory of Experimental Cell Culture (LECCel), UFF - Universidade Federal Fluminense, Niterói, RJ, Brazil
| | - Gutemberg Alves
- Hospital Antônio Pedro, Molecular and Cell Biology Department, UFF - Universidade Federal Fluminense, Niterói, RJ, Brazil
| | - Vladi Oliveira Guimarães
- Department of Clinical Dentistry, Laboratory of Experimental Cell Culture (LECCel), UFF - Universidade Federal Fluminense, Niterói, RJ, Brazil
| | - Marco Antônio Gallito
- Department of Clinical Dentistry, Laboratory of Experimental Cell Culture (LECCel), UFF - Universidade Federal Fluminense, Niterói, RJ, Brazil
| | - Felipe Oliveira
- Department of Clinical Dentistry, Laboratory of Experimental Cell Culture (LECCel), UFF - Universidade Federal Fluminense, Niterói, RJ, Brazil
| | - Míriam Zaccaro Scelza
- Department of Clinical Dentistry, Laboratory of Experimental Cell Culture (LECCel), UFF - Universidade Federal Fluminense, Niterói, RJ, Brazil
| |
Collapse
|
4
|
Effects of soft denture liners on L929 fibroblasts, HaCaT keratinocytes, and RAW 264.7 macrophages. BIOMED RESEARCH INTERNATIONAL 2014; 2014:840613. [PMID: 25295276 PMCID: PMC4177820 DOI: 10.1155/2014/840613] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Revised: 08/20/2014] [Accepted: 08/21/2014] [Indexed: 01/22/2023]
Abstract
The effects of six soft liners (Ufi Gel P (UG), Sofreliner S (SR), Durabase Soft (D), Trusoft (T), Coe Comfort (CC), and Softone (ST)) on L929, HaCat, and RAW 264.7 cells were investigated. Eluates (24 and 48 h) from the materials were applied on the cells and the viability, type of cell death, and morphology were evaluated. Cells were also seeded on the specimens' surfaces (direct contact) and incubated (24 or 48 h), and viability was analyzed. Controls were cells in culture medium without eluates or specimens. For cell viability, no significant differences were found among materials or between extraction periods, and the liners were noncytotoxic or slightly cytotoxic. Morphology of RAW 264.7 cells was altered by the 24 h eluates from CC and D and the 48 h eluates from SR, CC, and D. The 24 and 48 h eluates from all materials (except T) increased the percentages of L929 necrotic cells. For direct contact tests, the lowest cytotoxicity was observed for UG and SR. Although eluates did not reduce viability, morphology alterations and increase in necrosis were seen. Moreover, in the direct contact, effects on viability were more pronounced, particularly for D, T, CC and ST. Thus, the use of UG and SR might reduce the risk of adverse effects.
Collapse
|
5
|
Bail M, Meister LMB, Campagnoli EB, Jorge JH, Ban MDCI, Sanchez-Ayala A, Campanha NH. Histopathological changes by the use of soft reline materials: a rat model study. PLoS One 2014; 9:e100293. [PMID: 24963657 PMCID: PMC4070917 DOI: 10.1371/journal.pone.0100293] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Accepted: 05/22/2014] [Indexed: 11/19/2022] Open
Abstract
Aim To assess the histopathological changes of rat palatal mucosa exposed to soft reline materials. Methods Forty-five adult female Wistar rats with controlled living conditions and fed ad libitum were employed. Palatal appliances of heat-polymerized acrylic resin Lucitone 550 were manufactured and worn by forty animals during 14 days. Five animals did not use the appliances (G1) and were used to control the appliance influence. One experimental group (n = 10) used the appliances without any relining material (G2) to control the material effect. Three experimental groups (n = 10) received the following soft reline materials below appliances: Dentusoft (G3), Dentuflex (G4), and Trusoft (G5). Appliances from half of each experimental group(n = 5) was immersed in water bath at 55°C for 10 min before use. Animals were slaughtered and the palates were fixed in 10% buffered formalin. Hematoxylin and eosin stained sections of 5 µm were analyzed by computerized planimetry. Cellular compartment, keratin and total epithelial thickness, and basement membrane length were measured to histopathological description.Analysis of variance and Tukey post-hoc test were used to data examination(α = 0.05). Results For heat-treatment groups, G4 showed less elongated ridges at the basal layer interface (p = 0.037) than G2. When comparing the conditions with and without heat-treatment, only G2 showed a significant decrease in the cellular compartment, keratin layer and total epithelium thickness (p<0.05). Conclusion The post-polymerization for Lucitone 550 was an effective method to reduce the changes in the rat palatal mucosa. The soft reline materials tested did not cause significant histopathological changes in the rat palatal mucosa.
Collapse
Affiliation(s)
- Michele Bail
- PhD Student, Department of Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| | | | - Eduardo Bauml Campagnoli
- Professor, Department of Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| | - Janaina Habib Jorge
- Professor, Department of Dental Materials and Prosthodontics, Araraquara Dental School, Univ. Estadual Paulista, UNESP, Araraquara, São Paulo, Brazil
- * E-mail:
| | | | - Alfonso Sanchez-Ayala
- Professor, Department of Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| | - Nara Hellen Campanha
- Professor, Department of Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| |
Collapse
|
6
|
ATAY A, BOZOK CETINTAS V, CAL E, KOSOVA B, KESERCIOGLU A, GUNERI P. Cytotoxicity of hard and soft denture lining materials. Dent Mater J 2012. [DOI: 10.4012/dmj.2012-209] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
7
|
Tay LY, Herrera DR, Quishida CCC, Carlos IZ, Jorge JH. Effect of water storage and heat treatment on the cytotoxicity of soft liners. Gerodontology 2011; 29:e275-80. [DOI: 10.1111/j.1741-2358.2011.00463.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
8
|
KANIE T, KADOKAWA A, ARIKAWA H, FUJII K, BAN S. Effects of adding methacrylate monomers on viscosity and mechanical properties of experimental light-curing soft lining materials based on urethane (meth)acrylate oligomers. Dent Mater J 2008; 27:856-61. [DOI: 10.4012/dmj.27.856] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|