1
|
Obergassel J, Nies M, Taraba S, Rottner L, Lemoine MD, My I, Moser F, Rieß JL, Schenker N, Dinshaw L, Schleberger R, Reißmann B, Meyer C, Willems S, Rillig A, Kirchhof P, Metzner A. Pulmonary vein reconnection and repeat ablation characteristics following cryoballoon-compared to radiofrequency-based pulmonary vein isolation. J Cardiovasc Electrophysiol 2024; 35:1766-1778. [PMID: 38956821 DOI: 10.1111/jce.16343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/16/2024] [Accepted: 06/06/2024] [Indexed: 07/04/2024]
Abstract
BACKGROUND Despite advances in efficacy and safety of pulmonary vein isolation (PVI), atrial fibrillation (AF) recurrence after PVI remains common. PV-reconnection is the main finding during repeat PVI procedures performed to treat recurrent AF. OBJECTIVE To analyze pulmonary vein (PV) reconnection patterns during repeat ablation procedures in a large cohort of consecutive patients undergoing radio frequency or cryoballoon-based PVI. METHODS Retrospective analysis of PV-reconnection patterns and analysis of re-ablation strategies in consecutive index RF- and CB-based PVI and their respective re-ablation procedures during concomitant usage of both energy sources at a single high-volume center in Germany. RESULTS A total of 610 first (06/2015-10/2022) and 133 s (01/2016-11/2022) repeat ablation procedures after 363 (60%) RF- and 247 (40%) CB-based index PVIs between 01/2015 and 12/2021 were analyzed. PV-reconnection was found in 509/610 (83%) patients at first and 74/133 (56%) patients at second repeat procedure. 465 of 968 (48%) initially via CB isolated PVs were reconnected at first re-ablation but 796 of 1422 initially RF-isolated PV (56%) were reconnected (OR: 0.73 [95% CI: 0.62-0.86]; p < .001). This was driven by fewer reconnections of the left PVs (LSPV: OR: 0.60 [95% CI: 0.42-0.86]; p = .005 and LSPV: 0.67 [0.47-0.95]; p = .026). PV-reconnection was more likely after longer, RF-based index PVI and in older females. Repeat procedures were shorter after CB-compared to after RF-PVI. CONCLUSIONS Reconnection remains the most common reason for repeat AF ablation procedures after PVI. Our data suggest to preferentially use of the cryoballoon during index PVI, especially in older women.
Collapse
Affiliation(s)
- J Obergassel
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Germany
| | - M Nies
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Germany
| | - S Taraba
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - L Rottner
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - M D Lemoine
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - I My
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - F Moser
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - J L Rieß
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Germany
| | - N Schenker
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - L Dinshaw
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - R Schleberger
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - B Reißmann
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - C Meyer
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Germany
- Department of Cardiology, Angiology and Intensive Care, EVK Düsseldorf, cNEP, Cardiac Neuro- and Electrophysiology Research Consortium, Düsseldorf, Germany
- Institute for Neural and Sensory Physiology, cNEP, cardiac Neuro- and Electrophysiology Research Consortium, Heinrich Heine University Düsseldorf, Medical Faculty, Düsseldorf, Germany
| | - S Willems
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Germany
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - A Rillig
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - P Kirchhof
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Germany
- Institute of Cardiovascular Sciences, University of Birmingham, Birmingham, UK
| | - A Metzner
- Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
2
|
Brahier MS, Friedman DJ, Bahnson TD, Piccini JP. Repeat catheter ablation for atrial fibrillation. Heart Rhythm 2024; 21:471-483. [PMID: 38101500 DOI: 10.1016/j.hrthm.2023.12.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 11/28/2023] [Accepted: 12/08/2023] [Indexed: 12/17/2023]
Abstract
Catheter ablation of atrial fibrillation (AF) is an established therapy that reduces AF burden, improves quality of life, and reduces the risks of cardiovascular outcomes. Although there are clear guidelines for the application of de novo catheter ablation, there is less evidence to guide recommendations for repeat catheter ablation in patients who experience recurrent AF. In this review, we examine the rationale for repeat ablation, mechanisms of recurrence, patient selection, optimal timing, and procedural strategies. We discuss additional important considerations, including treatment of comorbidities and risk factors, risk of complications, and effectiveness. Mechanisms of recurrent AF are often due to non-pulmonary vein (non-PV) triggers; however, there is insufficient evidence supporting the routine use of empiric lesion sets during repeat ablation. The emergence of pulsed field ablation may alter the safety and effectiveness of de novo and repeat ablation. Extrapolation of data from randomized trials of de novo ablation does not optimally inform efficacy in cases of redo ablation. Additional large, randomized controlled trials are needed to address important clinical questions regarding procedural strategies and timing of repeat ablation.
Collapse
Affiliation(s)
- Mark S Brahier
- Electrophysiology Section, Duke Heart Center, Duke University Hospital & Duke Clinical Research Institute, Durham, North Carolina
| | - Daniel J Friedman
- Electrophysiology Section, Duke Heart Center, Duke University Hospital & Duke Clinical Research Institute, Durham, North Carolina
| | - Tristram D Bahnson
- Electrophysiology Section, Duke Heart Center, Duke University Hospital & Duke Clinical Research Institute, Durham, North Carolina
| | - Jonathan P Piccini
- Electrophysiology Section, Duke Heart Center, Duke University Hospital & Duke Clinical Research Institute, Durham, North Carolina.
| |
Collapse
|
3
|
Yilmaz M, Candemir B. Approach to recurrence of atrial fibrillation after catheter ablation. Minerva Cardiol Angiol 2021; 69:81-93. [PMID: 33691388 DOI: 10.23736/s2724-5683.20.05173-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Atrial fibrillation (AF) is the most commonly observed sustained rhythm disorder during adult ages. Since it has been shown that the ectopic beat initiating AF is usually caused by pulmonary veins, AF ablation has become the mainstay of therapy worldwide. Cryoballoon and radiofrequency ablation are the most commonly used methods in today's technologies. However, despite technological advances, the success of a single procedure in AF ablation is still limited and multiple procedures may be required for the majority of patients. In cases in which a redo ablation is required, pulmonary vein isolation is still the main target, but non-pulmonary vein targets should also be considered in AF episodes that continue despite multiple ablations. Many issues are still unclear as to which energy to choose in the first procedure, and what ablation strategy will be utilized when a redo ablation is required. The studies on this subject are very limited but, it still seems feasible and a rational approach to utilize a customized treatment strategy in each specific patient subgroup.
Collapse
Affiliation(s)
- Mustafa Yilmaz
- Department of Cardiology, Faculty of Medicine, Baskent University, Adana, Turkey -
| | - Basar Candemir
- Department of Cardiology, Faculty of Medicine, Ankara University, Ankara, Turkey
| |
Collapse
|