1
|
Wilke H, Betz VM, Kienle A. Biomechanical in vitro evaluation of the kangaroo spine in comparison with human spinal data. J Anat 2023; 243:128-137. [PMID: 36929138 PMCID: PMC10273331 DOI: 10.1111/joa.13852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 01/12/2023] [Accepted: 02/14/2023] [Indexed: 03/18/2023] Open
Abstract
On the basis of the kangaroo's pseudo-biped locomotion and its upright position, it could be assumed that the kangaroo might be an interesting model for spine research and that it may serve as a reasonable surrogate model for biomechanical in vitro tests. The purpose of this in vitro study was to provide biomechanical properties of the kangaroo spine and compare them with human spinal data from the literature. In addition, references to already published kangaroo anatomical spinal parameters will be discussed. Thirteen kangaroo spines from C4 to S4 were sectioned into single-motion segments. The specimens were tested by a spine tester under pure moments. The range of motion and neutral zone of each segment were determined in flexion and extension, right and left lateral bending and left and right axial rotation. Overall, we found greater flexibility in the kangaroo spine compared to the human spine. Similarities were only found in the cervical, lower thoracic and lumbar spinal regions. The range of motion of the kangaroo and human spines displayed comparable trends in the cervical (C4-C7), lower thoracic and lumbar regions independent of the motion plane. In the upper and middle thoracic regions, the flexibility of the kangaroo spine was considerably larger. These results suggested that the kangaroo specimens could be considered to be a surrogate, but only in particular cases, for biomechanical in vitro tests.
Collapse
Affiliation(s)
- Hans‐Joachim Wilke
- Institute of Orthopaedic Research and BiomechanicsTrauma Research Centre Ulm, University of UlmUlmGermany
| | - Volker Michael Betz
- Institute of Orthopaedic Research and BiomechanicsTrauma Research Centre Ulm, University of UlmUlmGermany
| | | |
Collapse
|
2
|
Chen X, Kohan S, Bhargav D, Choi J, Perera S, Dean C, Chopra N, Sial A, Sandhu HS, Apos E, Appleyard R, Diwan AD. Phase 1 evaluation of an elastomeric nucleus pulposus device as an option to augment disc at microdiscectomy: Experimental results from biomechanical and biocompatibility testing and first in human. JOR Spine 2023; 6:e1250. [PMID: 37361335 PMCID: PMC10285756 DOI: 10.1002/jsp2.1250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 01/11/2023] [Accepted: 01/23/2023] [Indexed: 06/28/2023] Open
Abstract
Objective Whilst microdiscectomy is an excellent reliever of pain for recalcitrant lumbar disc herniation (LDH), it has a high failure rate over time due to the ensuing reduction in mechanical stabilization and support of the spine. One option is to clear the disc and replace it with a nonhygroscopic elastomer. Here, we present the evaluation of biomechanical and biological behavior of a novel elastomeric nucleus device (Kunovus disc device [KDD]), consisting of a silicone jacket and a two-part in situ curing silicone polymer filler. Materials and Methods ISO 10993 and American Society for Testing and Materials (ASTM) standards were used to evaluate the biocompatibility and mechanics of KDD. Sensitization, intracutaneous reactivity, acute systemic toxicity, genotoxicity, muscle implantation study, direct contact matrix toxicity assay, and cell growth inhibition assay were performed. Fatigue test, static compression creep testing, expulsion testing, swell testing, shock testing, and aged fatigue testing were conducted to characterize the mechanical and wear behavior of the device. Cadaveric studies to develop a surgical manual and evaluate feasibility were conducted. Finally, a first-in-human implantation was conducted to complete the proof of principle. Results The KDD demonstrated exceptional biocompatibility and biodurability. Mechanical tests showed no Barium-containing particles in fatigue test, no fracture of nucleus in static compression creep testing, no extrusion and swelling, and no material failure in shock and aged fatigue testing. Cadaver training sessions showed that KDD was deemed implantable during microdiscectomy procedures in a minimally invasive manner. Following IRB approval, the first implantation in a human showed no intraoperative vascular and neurological complications and demonstrated feasibility. This successfully completed Phase 1 development of the device. Conclusion The elastomeric nucleus device may mimic native disc behavior in mechanical tests, offering an effective way for treating LDH by way of Phase 2 and subsequent clinical trials or postmarket surveillance in the future.
Collapse
Affiliation(s)
- Xiaolong Chen
- Spine Labs, St. George & Sutherland Clinical School, University of New South WalesSydneyNew South WalesAustralia
- Kunovus TechnologiesSydneyNew South WalesAustralia
| | - Saeed Kohan
- St. George Hospital, University of New South WalesSydneyNew South WalesAustralia
| | | | | | | | - Cameron Dean
- Kunovus TechnologiesSydneyNew South WalesAustralia
| | - Neha Chopra
- Spine Labs, St. George & Sutherland Clinical School, University of New South WalesSydneyNew South WalesAustralia
- Spine Service, Department of Orthopaedic SurgerySt. George Hospital CampusSydneyNew South WalesAustralia
| | - Alisha Sial
- Spine Labs, St. George & Sutherland Clinical School, University of New South WalesSydneyNew South WalesAustralia
- Spine Service, Department of Orthopaedic SurgerySt. George Hospital CampusSydneyNew South WalesAustralia
| | - Harvinder S. Sandhu
- Spinal Surgical Service, Hospital for Special Surgery, Weill Medical College of Cornell UniversityNew YorkNew YorkUSA
| | - Esther Apos
- Kunovus TechnologiesSydneyNew South WalesAustralia
- Cmsscidoc Pty LtdMelbourneVictoriaAustralia
| | - Richard Appleyard
- Orthopaedic Biomechanics Research Group, Department of Biomedical Sciences, Faculty of Medicine and Health SciencesMacquarie UniversitySydneyNew South WalesAustralia
| | - Ashish D. Diwan
- Spine Labs, St. George & Sutherland Clinical School, University of New South WalesSydneyNew South WalesAustralia
- Spine Service, Department of Orthopaedic SurgerySt. George Hospital CampusSydneyNew South WalesAustralia
| |
Collapse
|
3
|
Wilke HJ, Betz VM, Kienle A. Morphometry of the kangaroo spine and its comparison with human spinal data. J Anat 2020; 238:626-642. [PMID: 33025596 PMCID: PMC7855064 DOI: 10.1111/joa.13323] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 09/09/2020] [Accepted: 09/09/2020] [Indexed: 11/30/2022] Open
Abstract
The upright posture of the kangaroo suggests that the spine of the kangaroo could be a possible substitute model for biomechanical studies of the human spine. A prerequisite for this should be the agreement of anatomy in humans and kangaroos. The purpose of this study was to investigate the anatomical parameters of the kangaroo spine from C4 to S4 and compare them with existing anatomical data of the human spine. Eight complete spines of the red giant kangaroo were obtained and 21 anatomical parameters were measured from the vertebral bodies, spinal canal, endplate, pedicles, intervertebral discs, transverse, and spinous processes. Most similarities between kangaroo and human spines were found for the vertebral bodies in the cervical and the lumbar spine. The largest differences were evident for the spinous processes. Although both species are somehow upright, these differences may be explained by the way how they move. Jumping probably requires more muscle strength than walking on two legs.
Collapse
Affiliation(s)
- Hans-Joachim Wilke
- Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, University of Ulm, Ulm, Germany
| | | | | |
Collapse
|
4
|
Claeson AA, Vresilovic EJ, Showalter BL, Wright AC, Gee JC, Malhotra NR, Elliott DM. Human Disc Nucleotomy Alters Annulus Fibrosus Mechanics at Both Reference and Compressed Loads. J Biomech Eng 2019; 141:1110011-11100112. [PMID: 31141601 PMCID: PMC6808005 DOI: 10.1115/1.4043874] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 05/25/2019] [Indexed: 10/19/2023]
Abstract
Nucleotomy is a common surgical procedure and is also performed in ex vivo mechanical testing to model decreased nucleus pulposus (NP) pressurization that occurs with degeneration. Here, we implement novel and noninvasive methods using magnetic resonance imaging (MRI) to study internal 3D annulus fibrosus (AF) deformations after partial nucleotomy and during axial compression by evaluating changes in internal AF deformation at reference loads (50 N) and physiological compressive loads (∼10% strain). One particular advantage of this methodology is that the full 3D disc deformation state, inclusive of both in-plane and out-of-plane deformations, can be quantified through the use of a high-resolution volumetric MR scan sequence and advanced image registration. Intact grade II L3-L4 cadaveric human discs before and after nucleotomy were subjected to identical mechanical testing and imaging protocols. Internal disc deformation fields were calculated by registering MR images captured in each loading state (reference and compressed) and each condition (intact and nucleotomy). Comparisons were drawn between the resulting three deformation states (intact at compressed load, nucleotomy at reference load, nucleotomy at compressed load) with regard to the magnitude of internal strain and direction of internal displacements. Under compressed load, internal AF axial strains averaged -18.5% when intact and -22.5% after nucleotomy. Deformation orientations were significantly altered by nucleotomy and load magnitude. For example, deformations of intact discs oriented in-plane, whereas deformations after nucleotomy oriented axially. For intact discs, in-plane components of displacements under compressive loads oriented radially outward and circumferentially. After nucleotomy, in-plane displacements were oriented radially inward under reference load and were not significantly different from the intact state at compressed loads. Re-establishment of outward displacements after nucleotomy indicates increased axial loading restores the characteristics of internal pressurization. Results may have implications for the recurrence of pain, design of novel therapeutics, or progression of disc degeneration.
Collapse
Affiliation(s)
- Amy A Claeson
- Mem. ASMEBiomedical Engineering,University of Delaware,160 Colburn Lab,150 Academy Street,Newark, DE 19716e-mail:
| | - Edward J Vresilovic
- Orthopaedic and Rehabilitation,Pennsylvania State University,EC089 500 University Drive,Hershey, PA 17033e-mail:
| | - Brent L Showalter
- Bioengineering,University of Pennsylvania,242 Stemmler Hall,36th Street & Hamilton Walk,Philadelphia, PA 19104e-mail:
| | - Alexander C Wright
- Radiology,University of Pennsylvania,1st Floor Silverstein Pavilion,3400 Spruce Street,Philadelphia, PA 19104e-mail:
| | - James C Gee
- Radiology,University of Pennsylvania,6th Floor Richards,3700 Hamilton Walk,Philadelphia, PA 19104e-mail:
| | - Neil R Malhotra
- Neurosurgery,University of Pennsylvania,3rd Floor Silverstein Pavilion,3400 Spruce Street,Philadelphia, PA 19104e-mail:
| | - Dawn M Elliott
- Mem. ASMEBiomedical Engineering,University of Delaware,160 Colburn Lab,150 Academy Street,Newark, DE 19716e-mail:
| |
Collapse
|
5
|
Chamoli U, Umali J, Kleuskens MWA, Chepurin D, Diwan AD. Morphological characteristics of the kangaroo lumbar intervertebral discs and comparison with other animal models used in spine research. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2019; 29:652-662. [PMID: 31240440 DOI: 10.1007/s00586-019-06044-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 06/04/2019] [Accepted: 06/18/2019] [Indexed: 11/27/2022]
Abstract
PURPOSE Animal models are frequently used to elucidate pathomechanism and pathophysiology of various disorders of the human intervertebral disc (IVD) and also to develop therapeutic approaches. Here we report morphological characteristics of the kangaroo lumbar IVDs and compare them with other animal models used in spine research. METHODS Twenty-five fresh-frozen cadaveric lumbar spines (T12-S1) derived from kangaroo carcases (Macropus giganteus) of undetermined age were first scanned in a C-Arm X-ray machine. A photograph of the axial section of the disc including a calibrated metric scale was also acquired. The digital radiographs and photographs were processed in ImageJ to determine the axial and sagittal plane dimensions for the whole disc (WD) and the nucleus pulposus (NP) and the mid-sagittal disc height for all the lumbar levels. RESULTS Our results suggest that the L6-S1 IVD in kangaroos is distinctly large compared with the upper lumbar IVDs. Based on previously published data, human lumbar IVDs are the largest of all the animal IVDs used in spine research, with camelid cervical IVDs being the closest relative in absolute dimensions (llamas: 78% in disc height, 40% in WD volume, and 38% in NP volume). Kangaroo L6-S1 IVD was approximately 51% in height, 20% in WD volume, and 20% in NP volume of the human lumbar IVD. CONCLUSIONS We conclude that morphological similarities exist between a kangaroo and human lumbar IVD, especially with the lima bean shape in the axial plane, wedge shape in the sagittal plane, convexity at the cephalad endplates, and percentage volume occupied by the NP in the IVD. These slides can be retrieved under Electronic Supplementary Material.
Collapse
Affiliation(s)
- Uphar Chamoli
- Spine Service, Department of Orthopaedic Surgery, St. George and Sutherland Clinical School, University of New South Wales Australia, Kogarah, Sydney, NSW, 2217, Australia.
- Faculty of Engineering and Information Technology, School of Biomedical Engineering, University of Technology Sydney, Ultimo, NSW, 2007, Australia.
| | - Jose Umali
- Spine Service, Department of Orthopaedic Surgery, St. George and Sutherland Clinical School, University of New South Wales Australia, Kogarah, Sydney, NSW, 2217, Australia
| | - Meike W A Kleuskens
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB, Eindhoven, The Netherlands
| | - Daniel Chepurin
- Spine Service, Department of Orthopaedic Surgery, St. George and Sutherland Clinical School, University of New South Wales Australia, Kogarah, Sydney, NSW, 2217, Australia
- Faculty of Medicine Nursing and Health Sciences, Monash University, Clayton, Melbourne, VIC, 3168, Australia
| | - Ashish D Diwan
- Spine Service, Department of Orthopaedic Surgery, St. George and Sutherland Clinical School, University of New South Wales Australia, Kogarah, Sydney, NSW, 2217, Australia
| |
Collapse
|
6
|
Chamoli U, Korkusuz MH, Sabnis AB, Manolescu AR, Tsafnat N, Diwan AD. Global and segmental kinematic changes following sequential resection of posterior osteoligamentous structures in the lumbar spine: An in vitro biomechanical investigation using pure moment testing protocols. Proc Inst Mech Eng H 2016; 229:812-21. [PMID: 26503842 DOI: 10.1177/0954411915612503] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Lumbar spinal surgeries may compromise the integrity of posterior osteoligamentous structures implicating mechanical stability. Circumstances necessitating a concomitant surgery to achieve restabilisation are not well understood. The main objective of this in vitro study was to quantify global and segmental (index and adjacent levels) kinematic changes in the lumbar spine following sequential resection of the posterior osteoligamentous structures using pure moment testing protocols. Six fresh frozen cadaveric kangaroo lumbar spines (T12-S1) were tested under a bending moment in flexion-extension, bilateral bending, and axial torsion in a 6-degree-of-freedom Kinematic Spine Simulator. Specimens were tested in the following order: intact state (D0), after interspinous and supraspinous ligaments transection between L4 and L5 (D1), further after a total bilateral facetectomy between L4 and L5 (D2). Segmental motions at the cephalad, damaged, and caudal levels were recorded using an infrared-based motion tracking device. Following D1, no significant change in the global range of motion was observed in any of the bending planes. Following D2, a significant increase in the global range of motion from the baseline (D0) was observed in axial torsion (median normalised change +20%). At the damaged level, D2 resulted in a significant increase in the segmental range of motion in flexion-extension (+77%) and axial torsion (+492%). Additionally, a significant decrease in the segmental range of motion in axial torsion (-35%) was observed at the caudal level following D2. These results suggest that a multi-segment lumbar spine acts as a mechanism for transmitting motions, and that a compromised joint may significantly alter motion transfer to adjacent segments. We conclude that the interspinous and supraspinous ligaments play a modest role in restricting global spinal motions within physiologic limits. Following interspinous and supraspinous ligaments transection, a total bilateral facetectomy resulted in a significant increase in axial torsion motion, both at global and damaged levels, accompanied with a compensatory decrease in motion at the caudal level.
Collapse
Affiliation(s)
- Uphar Chamoli
- Spine Service, Department of Orthopaedic Surgery, St George & Sutherland Clinical School, University of New South Wales Australia, Sydney, NSW, Australia School of Mechanical and Manufacturing Engineering, University of New South Wales Australia, Sydney, NSW, Australia
| | - Mert H Korkusuz
- Spine Service, Department of Orthopaedic Surgery, St George & Sutherland Clinical School, University of New South Wales Australia, Sydney, NSW, Australia
| | - Ashutosh B Sabnis
- Spine Service, Department of Orthopaedic Surgery, St George & Sutherland Clinical School, University of New South Wales Australia, Sydney, NSW, Australia
| | - Andrei R Manolescu
- Spine Service, Department of Orthopaedic Surgery, St George & Sutherland Clinical School, University of New South Wales Australia, Sydney, NSW, Australia
| | - Naomi Tsafnat
- School of Mechanical and Manufacturing Engineering, University of New South Wales Australia, Sydney, NSW, Australia
| | - Ashish D Diwan
- Spine Service, Department of Orthopaedic Surgery, St George & Sutherland Clinical School, University of New South Wales Australia, Sydney, NSW, Australia
| |
Collapse
|
7
|
Chamoli U, Chen AS, Diwan AD. Interpedicular kinematics in an in vitro biomechanical assessment of a bilateral lumbar spondylolytic defect. Clin Biomech (Bristol, Avon) 2014; 29:1108-15. [PMID: 25454471 DOI: 10.1016/j.clinbiomech.2014.10.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 10/06/2014] [Accepted: 10/06/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND A spondylolytic defect in lumbar vertebra is a common condition during early childhood and adolescence, and is considered a precursor to spondylolisthesis. This study examined whether a bilateral spondylolytic defect in lumbar spine intrinsically results in increased intervertebral translations during different bending motions. METHODS Seven fresh frozen cadaveric kangaroo lumbar (L1-L6) spine specimens were tested in a kinematic spine simulator; first in their intact state, followed by creating a bilateral spondylolytic defect at L4 and retesting. In addition to recording global and segmental range of motions, the pedicles at L3, L4, and L5 vertebrae were digitized bilaterally and virtually tracked throughout testing. Interpedicular kinematic metrics were employed to capture any changes in translatory motions during flexion-extension, bilateral bending, and axial torsion testing modes. FINDINGS Following the defect, range of motion at the defect level (L4-L5) increased significantly in all the three motion planes. At L4-L5, normalized interpedicular displacement increased significantly in flexion-extension (median change +156%) and bilateral bending (median change +58%) motions, but changes in bending-plane and out-of-plane intervertebral translations were not significant in any of the testing modes. INTERPRETATION In the absence of any significant changes in bending-plane and out-of-plane intervertebral translations at L4-L5, changes in interpedicular displacement would directly correspond with the stretching of posterior annulus of the L4-L5 intervertebral disc. A bilateral spondylolytic defect at L4 may result in significant overstretching of the posterior annulus of the L4-L5 disc during flexion-extension and bilateral bending motions.
Collapse
Affiliation(s)
- Uphar Chamoli
- Spine Service, Department of Orthopaedic Surgery, St. George & Sutherland Clinical School, University of New South Wales, Kogarah, Sydney, NSW 2217, Australia; School of Mechanical and Manufacturing Engineering, University of New South Wales, Kensington campus, Sydney, NSW 2052, Australia.
| | - Alan S Chen
- Spine Service, Department of Orthopaedic Surgery, St. George & Sutherland Clinical School, University of New South Wales, Kogarah, Sydney, NSW 2217, Australia
| | - Ashish D Diwan
- Spine Service, Department of Orthopaedic Surgery, St. George & Sutherland Clinical School, University of New South Wales, Kogarah, Sydney, NSW 2217, Australia
| |
Collapse
|