Machado A, Pereira I, Costa F, Brandão A, Pereira JE, Maurício AC, Santos JD, Amaro I, Falacho R, Coelho R, Cruz N, Gama M. Randomized clinical study of injectable dextrin-based hydrogel as a carrier of a synthetic bone substitute. Clin Oral Investig 2023; 27:979-994. [PMID: 36707442 PMCID: PMC9985577 DOI: 10.1007/s00784-023-04868-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 01/14/2023] [Indexed: 01/29/2023]
Abstract
OBJECTIVES This study aimed to improve the performance and mode of administration of a glass-reinforced hydroxyapatite synthetic bone substitute, Bonelike by Biosckin® (BL®), by association with a dextrin-based hydrogel, DEXGEL, to achieve an injectable and moldable device named DEXGEL Bone. METHODS Twelve participants requiring pre-molar tooth extraction and implant placement were enrolled in this study. BL® granules (250-500 µm) were administered to 6 randomized participants whereas the other 6 received DEXGEL Bone. After 6 months, a bone biopsy of the grafted area was collected for histological and histomorphometric evaluation, prior to implant placement. The performance of DEXGEL Bone and BL® treatments on alveolar preservation were further analyzed by computed tomography and Hounsfield density analysis. Primary implant stability was analyzed by implant stability coefficient technique. RESULTS The healing of defects was free of any local or systemic complications. Both treatments showed good osseointegration with no signs of adverse reaction. DEXGEL Bone exhibited increased granule resorption (p = 0.029) accompanied by a tendency for more new bone ingrowth (although not statistically significant) compared to the BL® group. The addition of DEXGEL to BL® granules did not compromise bone volume or density, being even beneficial for implant primary stability (p = 0.017). CONCLUSIONS The hydrogel-reinforced biomaterial exhibited an easier handling, a better defect filling, and benefits in implant stability. CLINICAL RELEVANCE This study validates DEXGEL Bone safety and performance as an injectable carrier of granular bone substitutes for alveolar ridge preservation. TRIAL REGISTRATION European Databank on Medical Devices (EUDAMED) No. CIV-PT-18-01-02,705; Registo Nacional de Estudos Clínicos, RNEC, No. 30122.
Collapse
Affiliation(s)
- Alexandra Machado
- CEB, Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal.,LABBELS, Associate Laboratory, Braga, Guimarães, Portugal
| | - Isabel Pereira
- CEB, Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal.,LABBELS, Associate Laboratory, Braga, Guimarães, Portugal
| | - Filomena Costa
- CEB, Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal.,LABBELS, Associate Laboratory, Braga, Guimarães, Portugal
| | - Ana Brandão
- Biosckin, Molecular and Cell Therapies S.A., TecMaia, Rua Engenheiro Frederico Ulrich 2650, 4470-605, Maia, Portugal
| | - José Eduardo Pereira
- CECAV, Animal and Veterinary Research Centre, University of Trás-os-Montes and Alto Douro, 5001-801, Vila Real, Portugal.,Department of Veterinary Sciences, University of Trás-os-Montes and Alto Douro, 5001-801, Vila Real, Portugal
| | - Ana Colette Maurício
- Departamento de Clínicas Veterinárias, Instituto de Ciências Biomédicas de Abel Salazar (ICBAS), Universidade do Porto (UP), Rua de Jorge Viterbo Ferreira, N° 228, 4050-313, Porto, Portugal.,Centro de Estudos de Ciência Animal (CECA), Instituto de Ciências, Tecnologias e Agroambiente da Universidade do Porto (ICETA), Rua D. Manuel II, Apartado 55142, 4051-401, Porto, Portugal
| | - José Domingos Santos
- REQUIMTE/LAQV, Departamento de Engenharia Metalúrgica e Materiais, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-495, Porto, Portugal
| | - Inês Amaro
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3004-504, Coimbra, Portugal
| | - Rui Falacho
- Institute of Oral Implantology and Prosthodontics, Faculty of Medicine, University of Coimbra, 3004-504, Coimbra, Portugal
| | - Rui Coelho
- RESDEVMED, Unipessoal Lda., Travessa do Navega, 436 C, 3885-183, Ovar, Portugal
| | - Nuno Cruz
- Faculty of Dentistry, Universitat Internacional de Catalunya, 08017, Barcelona, Spain
| | - Miguel Gama
- CEB, Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal. .,LABBELS, Associate Laboratory, Braga, Guimarães, Portugal.
| |
Collapse
|
3
|
Cortez PP, Silva MA, Santos M, Armada-da-Silva P, Afonso A, Lopes MA, Santos JD, Maurício AC. A glass-reinforced hydroxyapatite and surgical-grade calcium sulfate for bone regeneration: In vivo biological behavior in a sheep model. J Biomater Appl 2011; 27:201-17. [PMID: 21602251 DOI: 10.1177/0885328211399479] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
A glass-reinforced hydroxyapatite (HA) composite (Bonelike®) was developed for bone grafting. This biomaterial is composed of a modified HA matrix with α- and β-tricalcium phosphate secondary phases, resulting in higher solubility than single HA type of materials. Several in vitro and in vivo studies demonstrated that Bonelike® has a highly bioactive behavior, which was also confirmed by employing granular forms of this biomaterial in orthopedics and dental applications. However, a fast consolidation vehicle was needed to promote the fixation of Bonelike® granules if applied in larger defects or in unstable sites. Surgical-grade calcium sulfate (CS), which is widely recognized as a well-tolerated and inexpensive bone graft material, was the chosen vehicle to improve the handling characteristics of Bonelike® as it can be used in the form of a powder that is mixed with a liquid to form a paste that sets in situ. After application in non-critical monocortical defects in sheep, histological, and scanning electron microscopy evaluations demonstrated that Bonelike® associated to CS functioned as a very satisfactory scaffold for bone regeneration as it achieved synchronization of the ingrowing bone with biomaterial resorption and subsequent preservation of the bone graft initial volume. Therefore, our results indicate that CS is an effective vehicle for Bonelike® granules as it facilitates their application and does not interfere with their proven highly osteoconductive properties. In the opposite way, the incorporation of Bonelike® improves the bone regeneration capabilities of CS.
Collapse
Affiliation(s)
- Paulo Pegado Cortez
- Centro de Estudos de Ciência Animal-CECA, Instituto de Ciências e Tecnologias Agrárias e Agro-Alimentares-ICETA, Universidade do Porto, Campus Agrário de Vairão, 4485-661 Vairão, Portugal.
| | | | | | | | | | | | | | | |
Collapse
|
4
|
Gutierres M, Lopes MA, Sooraj Hussain N, Lemos AF, Ferreira JMF, Afonso A, Cabral AT, Almeida L, Santos JD. Bone ingrowth in macroporous Bonelike for orthopaedic applications. Acta Biomater 2008; 4:370-7. [PMID: 17716960 DOI: 10.1016/j.actbio.2007.06.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2006] [Revised: 04/30/2007] [Accepted: 06/21/2007] [Indexed: 10/23/2022]
Abstract
The aim of this study was to evaluate the biological behaviour of porous scaffold structures of Bonelike which is suitable for either direct clinical use or tissue engineering applications. Porous cylindrical specimens 8x10mm were implanted in the lateral aspect of the tibia of 13 patients (mean age 54 years), during osteotomy surgery for the treatment of medial compartment osteoarthritis of the knee. Implanted cylinders were retrieved at the same time as the removal of the blade plates at 3, 6, 9 and 12 months. Scanning electron microscopy and histological evaluations were performed to observe the biological responses of human bone tissue to porous Bonelike. The penetration depth was determined for all implantation periods, and after 6 months it was already possible to see new bone in the centre of the implanted cylinders, which gives 100% of penetration depth for all implantations periods except for 3 months when bone could only be seen in the peripherical region. Regarding the percentage of the area covered by new bone calculated from two-dimensional histological sections, values of 53+/-15, 76+/-12 and 88+/-9% were achieved for 6, 9 and 12 months, respectively. Due to its structural features porous Bonelike permitted effective vascularization and bone ingrowth, and therefore was fully osteointegrated as shown in the histological surveys. A slow biomaterial degradation with implantation time is envisaged since the material has displayed surface degradation. Bonelike scaffolds show potential for complete ingrowth of osseous tissue and restoration of vascularization throughout the defected site.
Collapse
Affiliation(s)
- M Gutierres
- FMUP - Faculdade de Medicina da Universidade do Porto, Hospital de São João, Largo Hernâni Monteiro, 4200 Porto, Portugal
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Gutierres M, Dias AG, Lopes MA, Hussain NS, Cabral AT, Almeida L, Santos JD. Opening wedge high tibial osteotomy using 3D biomodelling Bonelike macroporous structures: case report. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2007; 18:2377-82. [PMID: 17569003 DOI: 10.1007/s10856-007-3171-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2006] [Accepted: 09/12/2006] [Indexed: 05/15/2023]
Abstract
Two synthetic calcium phosphates in porous wedge shape, Bonelike and a commercial HA/beta-TCP biphasic material, were used as an alternative to bone autografts and allografts in the treatment of medial compartment osteoarthritis of varus knees. The structure of Bonelike has a 3D architecture that is computer controlled, and a composition that mimics the mineral composition of natural bone. The HA/beta-TCP biphasic material used as a control material in this study was prepared using conventional foaming based methods. No signs of inflammatory reactions were observed post-operatively for both materials. After 4 months signs of fusion at the osteotomy site and good integration of the implanted wedges were observed, showing good mechanical resistance. Concerning the final correction attained, the left knee revealed a satisfactory valgus of 10 degrees , but the right one only had a final value of 6 degrees . The clinical evaluation using International Knee Score (IKS) showed good outcome in all parameters with complete range of motion in both knees and climbing stairs without crutches with only slight pain.
Collapse
Affiliation(s)
- M Gutierres
- FMUP - Faculdade de Medicina da Universidade do Porto, Hospital de São João, Largo Hernâni Monteiro, Porto 4200, Portugal
| | | | | | | | | | | | | |
Collapse
|
6
|
Gutierres M, Hussain NS, Lopes MA, Afonso A, Cabral AT, Almeida L, Santos JD. Histological and scanning electron microscopy analyses of bone/implant interface using the novel Bonelike synthetic bone graft. J Orthop Res 2006; 24:953-8. [PMID: 16609968 DOI: 10.1002/jor.20117] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Synthetic bone grafts provide an alternative to autografts and allografts. Bonelike is a patented synthetic bone graft that mimics the mineral composition of bone. The aim of the present work was to assess the biological behavior of Bonelike graft in humans, before using the material in orthopedic applications of bone regeneration, for example, in opening wedge high tibial osteotomies for medial knee osteoarthritis. Bonelike granules were implanted in cortical bone of 11 patients undergoing osteotomies, and new bone formation, osteoconductive properties, and resorption characteristics of the granules were analyzed. The granules ranged from 500 to 1000 microm and were implanted in the lateral aspect of the tibia. The patients' mean age was 59 years (range 48 to 70 years); there were eight women and three men, all suffering from medial compartment osteoarthritis of the knee. At surgery, a 1 x 1 x 1-cm cortical defect was created 3 cm distal to the entry point of the screws, in line with the long axis of tibia. The implanted Bonelike graft sample was extracted for analysis during removal of the metallic prosthesis after implantation times of 6, 9, and 12 months. Radiological follow-up, scanning electron microscopy, histological analysis, and histomorphometric measurements were conducted on the retrieved samples to assess bone regeneration in the defect area. Osteoconductive capacity was demonstrated by extensive mature bone formation around the implanted granules and high levels of percentage bone-to-graft contact (from 67-84%). Bonelike acted as an excellent bioactive scaffold, allowing the migration, proliferation, and differentiation of bone cells on its surface, and therefore regeneration of the defects was achieved in a rapid, controlled manner. Our results suggest that Bonelike graft is an excellent candidate for orthopedic applications where rapid new bone formation is a fundamental requirement.
Collapse
Affiliation(s)
- M Gutierres
- FMUP-Faculdade de Medicina da Universidade do Porto, Hospital de São João, Largo Hernâni Monteiro, 4200 Porto, Portugal
| | | | | | | | | | | | | |
Collapse
|