1
|
Boeykens K, Holvoet T, Duysburgh I. Nasogastric tube insertion length measurement and tip verification in adults: a narrative review. Crit Care 2023; 27:317. [PMID: 37596615 PMCID: PMC10439641 DOI: 10.1186/s13054-023-04611-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 08/11/2023] [Indexed: 08/20/2023] Open
Abstract
Nasogastric feeding tube insertion is a common but invasive procedure most often blindly placed by nurses in acute and chronic care settings. Although usually not harmful, serious and fatal complications with misplacement still occur and variation in practice still exists. These tubes can be used for drainage or administration of fluids, drugs and/or enteral feeding. During blind insertion, it is important to achieve correct tip position of the tube ideally reaching the body of the stomach. If the insertion length is too short, the tip and/or distal side-openings at the end of the tube can be located in the esophagus increasing the risk of aspiration (pneumonia). Conversely, when the insertion length is too long, the tube might kink in the stomach, curl upwards into the esophagus or enter the duodenum. Studies have demonstrated that the most frequently used technique to determine insertion length (the nose-earlobe-xiphoid method) is too short a distance; new safer methods should be used and further more robust evidence is needed. After blind placement, verifying correct gastric tip positioning is of major importance to avoid serious and sometimes lethal complications.
Collapse
Affiliation(s)
- Kurt Boeykens
- Nutrition Support Team, VITAZ Hospital, Moerlandstraat 1, 9100, Sint-Niklaas, Belgium.
| | - Tom Holvoet
- Nutrition Support Team, VITAZ Hospital, Moerlandstraat 1, 9100, Sint-Niklaas, Belgium
| | - Ivo Duysburgh
- Nutrition Support Team, VITAZ Hospital, Moerlandstraat 1, 9100, Sint-Niklaas, Belgium
| |
Collapse
|
2
|
Derwin R, Patton D, Strapp H, Moore Z. Wound pH and temperature as predictors of healing: an observational study. J Wound Care 2023; 32:302-310. [PMID: 37094930 DOI: 10.12968/jowc.2023.32.5.302] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023]
Abstract
OBJECTIVE The aim of this study was to measure wound pH, wound temperature and wound size together to gain further understanding of their impact as predictors of wound healing outcomes. METHOD This study employed a quantitative non-comparative, prospective, descriptive observational design. Participants with both acute and hard-to-heal (chronic) wounds were observed weekly for four weeks. Wound pH was measured using pH indicator strips, wound temperature was measured using an infrared camera and wound size was measured using the ruler method. RESULTS Most of the 97 participants (65%, n=63) were male; participant's ages ranged between 18 and 77 years (mean: 42±17.10. Most of the wounds observed were surgical 60%, (n=58) and 72% (n=70) of the wounds were classified as acute, with 28% (n=27) classified as hard-to-heal wounds. At baseline, there was no significant difference in pH between acute and hard-to-heal wounds; overall the mean pH was 8.34±0.32, mean temperature was 32.86±1.78°C) and mean wound area was 910.50±1132.30mm2. In week 4, mean pH was 7.71±1.11, mean temperature was 31.90±1.76°C and mean wound area was 339.90±511.70mm2. Over the study follow-up period, wound pH ranged from 5-9, from week 1 to week 4, mean pH reduced by 0.63 units from 8.34 to 7.71. Furthermore, there was a mean 3% reduction in wound temperature and a mean 62% reduction in wound size. CONCLUSION The study demonstrated that a reduction in pH and temperature was associated with increased wound healing as evidenced by a corresponding reduction in wound size. Thus, measuring pH and temperature in clinical practice may provide clinically meaningful data pertaining to wound status.
Collapse
Affiliation(s)
- Rosemarie Derwin
- School of Nursing and Midwifery, Royal College of Surgeons in Ireland (RCSI), University of Medicine and Health Sciences, Dublin
| | - Declan Patton
- School of Nursing and Midwifery, Royal College of Surgeons in Ireland (RCSI), University of Medicine and Health Sciences, Dublin
- Fakeeh College of Health Sciences, Jeddah, Saudi Arabia
- Faculty of Science, Medicine and Health, University of Wollongong, Australia
| | | | - Zena Moore
- School of Nursing and Midwifery, Royal College of Surgeons in Ireland (RCSI), University of Medicine and Health Sciences, Dublin
- School of Nursing & Midwifery, Griffith University, Queensland, Australia
- School of Health Sciences, Faculty of Life and Health Sciences Ulster University, Northern Ireland
- Cardiff University, Cardiff, Wales
- Department of Nursing, Fakeeh College for Medical Sciences, Jeddah, KSA
- Department of Public Health, Faculty of Medicine and Health Sciences, Ghent University, Belgium
- Lida Institute, Shanghai, China
| |
Collapse
|
3
|
Taskiran N, Sari D. The effectiveness of auscultatory, colorimetric capnometry and pH measurement methods to confirm placement of nasogastric tubes: A methodological study. Int J Nurs Pract 2022; 28:e13049. [DOI: 10.1111/ijn.13049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 02/21/2022] [Accepted: 02/27/2022] [Indexed: 11/29/2022]
Affiliation(s)
- Nihal Taskiran
- Department of Fundamentals of Nursing, College of Nursing Aydin Adnan Menderes University Aydin Turkey
| | - Dilek Sari
- Department of Fundamentals Nursing Ege University College of Nursing Izmir Turkey
| |
Collapse
|
4
|
Magnaghi LR, Alberti G, Pazzi BM, Zanoni C, Biesuz R. A green-PAD array combined with chemometrics for pH measurements. NEW J CHEM 2022. [DOI: 10.1039/d2nj03675d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This work presents the development of a green paper-based analytical device (Green-PAD) array for pH detection.
Collapse
Affiliation(s)
- Lisa R. Magnaghi
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
- Unità di Ricerca di Pavia, INSTM, Via G. Giusti 9, 50121 Firenze, Italy
| | - Giancarla Alberti
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
| | - Bianca M. Pazzi
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
| | - Camilla Zanoni
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
| | - Raffaela Biesuz
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
- Unità di Ricerca di Pavia, INSTM, Via G. Giusti 9, 50121 Firenze, Italy
| |
Collapse
|
5
|
Kamphuis GM, van Hattum JW, van Dongen-Lases EC, Henderickx MMEL, Beerlage HP. Introduction of a Standardized Approach of Electronic Urinary pH Monitoring to Assist Alkalization Therapy: A Uric Acid Urolithiasis Patient's Perspective. J Endourol 2021; 35:1563-1570. [PMID: 34210175 DOI: 10.1089/end.2020.0621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Introduction: This study evaluates the introduction of an electronic pH meter to measure the urinary pH in patients with uric acid (UA) urolithiasis and assess patient's perspective. Materials and Methods: Patients known with UA urolithiasis were included in this single-center, nonrandomized, prospective feasibility study, IDEAL stage 2a. Their experience with urolithiasis and satisfaction with the method of urinary pH monitoring before inclusion was evaluated. All patients received an electronic pH meter and standardized instructions. After a period of 6-12 weeks their experience and satisfaction with this pH meter and new regimen was assessed. Patient satisfaction was scored on a Likert scale 1-5. Results: Eighteen patients were included. Median age was 63 years and median body mass index was 30 kg/m2. The cohort consisted of 67% men and 33% women. In their medical history, 55% had unilateral stones, whereas 45% had bilateral stones. The median estimated glomerular filtration rate was 58 mL/minute/1.73 m2. Eighty-nine percent took medication to alkalize their urine, median 3.5 years. Fifteen patients used paper reagent strips and three used an electronic pH meter to assess urinary pH before this study. Satisfaction with the method of urinary pH measurement at inclusion was reasonable (median score 3; interquartile range [IQR] 1-4). Satisfaction with the new electronic pH meter was good (median score 4; IQR 3-5), as was the overall satisfaction (median score 4; IQR 3-5). The new electronic pH meter was slightly easier to use (median 3.5; IQR 1.75-5), as easy in maintenance (median 3; IQR 2-4), and significantly easier to read (median 5; IQR 4-5). The new electronic pH meter was better (median score 4; IQR 2.75-5) than their previous method. Conclusion: The introduction of a standardized approach of urinary pH monitoring for UA urolithiasis patients with an electronic pH meter leads to an easier interpretable outcome and higher patient satisfaction.
Collapse
Affiliation(s)
- Guido M Kamphuis
- Department of Urology and Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jons W van Hattum
- Department of Urology and Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Edmée C van Dongen-Lases
- Department of Clinical Chemistry, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | | | - Harrie P Beerlage
- Department of Urology and Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
6
|
Egelberg J, Pena N, Rivera R, Andruk C. Assessing the geographic specificity of pH prediction by classification and regression trees. PLoS One 2021; 16:e0255119. [PMID: 34379630 PMCID: PMC8357141 DOI: 10.1371/journal.pone.0255119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Accepted: 07/09/2021] [Indexed: 11/19/2022] Open
Abstract
Soil pH effects a wide range of critical biogeochemical processes that dictate plant growth and diversity. Previous literature has established the capacity of classification and regression trees (CARTs) to predict soil pH, but limitations of CARTs in this context have not been fully explored. The current study collected soil pH, climatic, and topographic data from 100 locations across New York’s Temperate Deciduous Forests (in the United States of America) to investigate the extrapolative capacity of a previously developed CART model as compared to novel CART and random forest (RF) models. Results showed that the previously developed CART underperformed in terms of predictive accuracy (RRMSE = 14.52%) when compared to a novel tree (RRMSE = 9.33%), and that a novel random forest outperformed both models (RRMSE = 8.88%), though its predictions did not differ significantly from the novel tree (p = 0.26). The most important predictors for model construction were climatic factors. These findings confirm existing reports that CART models are constrained by the spatial autocorrelation of geographic data and encourage the restricted application of relevant machine learning models to regions from which training data was collected. They also contradict previous literature implying that random forests should meaningfully boost the predictive accuracy of CARTs in the context of soil pH.
Collapse
Affiliation(s)
- Jacob Egelberg
- Department of Biochemistry, Northeastern University, Boston, Massachusetts, United States of America
- * E-mail:
| | - Nina Pena
- Department of Science, New Rochelle High School, New Rochelle, New York, United States of America
| | - Rachel Rivera
- Department of Science, New Rochelle High School, New Rochelle, New York, United States of America
| | - Christina Andruk
- Department of Biology, Iona College, New Rochelle, New York, United States of America
| |
Collapse
|
7
|
Green and high-yield synthesis of carbon dots for ratiometric fluorescent determination of pH and enzyme reactions. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 117:111264. [DOI: 10.1016/j.msec.2020.111264] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 07/01/2020] [Accepted: 07/03/2020] [Indexed: 11/20/2022]
|
8
|
Vu H, Nair A, Tran L, Pal S, Senkowsky J, Hu W, Tang L. A Device to Predict Short-Term Healing Outcome of Chronic Wounds. Adv Wound Care (New Rochelle) 2020; 9:312-324. [PMID: 32286205 PMCID: PMC7155926 DOI: 10.1089/wound.2019.1064] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Accepted: 11/03/2019] [Indexed: 11/12/2022] Open
Abstract
Objective: While myriads of studies have suggested that a survey of wound pH environment could indicate wound healing activities, it is not clear whether wound alkalinity can be used as a prognostic indicator of nonhealing wounds. Currently available systems cannot reliably assess the pH environment across wounds, which is the objective of this study. Approach: A disposable device, DETEC® pH, was developed and characterized on its ability to map wound alkalinity by pressing a freshly recovered wound dressing against its test surface. By comparing the wound's alkalinity and size reduction rates (∼7 days) following pH measurement, we assessed the capability of wound alkalinity to prognosticate subsequent short-term wound size reduction rates. Results: The device had high accuracy and specificity in determining the alkalinity of simulated wound fluids soaked onto wound dressing. The type of wound dressing type had an insignificant effect on its detection sensitivity. Upon testing discarded wound dressings from human patients, the device quickly determined alkaline and acidic wounds. Finally, statistical analyses of wound size reduction rates in wounds with various alkalinities confirmed that wound alkalinity has a strong influence on, at least, short-term wound healing activity. Innovation: Without directly contacting the patient, this device provides a quick assessment of wound alkalinity to prognosticate immediate and short-term wound healing activities. Conclusion: DETEC® pH may serve as a prognosis device for wound care specialists during routine wound assessment to predict wound healing progress. This information can assist the decision-making process in a clinical setting and augur well for chronic wound treatment. DETEC® pH can also be used as an aid for home health care nurses or health care providers to screen nonhealing wounds outside clinics.
Collapse
Affiliation(s)
- Hong Vu
- Progenitec, Inc., Arlington, Texas
| | | | - Lan Tran
- Progenitec, Inc., Arlington, Texas
| | - Suvra Pal
- Department of Mathematics, University of Texas at Arlington, Arlington, Texas
| | | | | | - Liping Tang
- Department of Bioengineering, University of Texas at Arlington, Arlington, Texas
| |
Collapse
|
9
|
Rowat AM, Graham C, Dennis M. Diagnostic accuracy of a pH stick, modified to detect gastric lipase, to confirm the correct placement of nasogastric tubes. BMJ Open Gastroenterol 2018; 5:e000218. [PMID: 30116546 PMCID: PMC6089299 DOI: 10.1136/bmjgast-2018-000218] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 06/29/2018] [Accepted: 07/05/2018] [Indexed: 11/13/2022] Open
Abstract
Objective The correct placement of a nasogastric feeding tube is usually confirmed by establishing that an aspirate is acidic using a pH stick. However, antacid medication and achlorhydria can cause false negative pH tests that may delay feeding and increase resource use. The purpose of this study was to evaluate a modified pH stick designed to detect gastric lipase and therefore reduce false negative tests. Methods In this prospective observational study, a convenience sample of adult patients who had either gastric and oesophageal samples taken during routine diagnostic gastroscopy (n=97) or bronchial and saliva samples taken during a bronchoscopy (n=106). The samples were tested by blinded observers using the modified and standard pH sticks. The sensitivities and specificities of the two pH sticks in identifying gastric and non-gastric aspirates were compared using the pH cut-off ≤5.5. Results The sensitivities of a pH≤5.5 to correctly identify gastric samples were 66% (95% CI 56 to 75) and 68% (95% CI 57 to 77) for the modified and the standard pH, respectively. The specificities were 81% (95% CI 76 to 85) and 79% (95% CI 74 to 84). There were no significant differences in the distribution of the discordant results between the paired gastric and non-gastric samples for both the modified and standard pH sticks at pH≤5.5 (both McNemar’s tests, p≥0.05). Conclusions There were no significant differences between the paired modified and standard pH tests for the gastric samples. Due to the limited accuracy of pH sticks, further research is required to identify accurate and cost-effective bedside methods to confirm the correct placement of nasogastric tubes.
Collapse
Affiliation(s)
- Anne M Rowat
- School of Health and Social Care, Edinburgh Napier University, Edinburgh, UK
| | - Catriona Graham
- Edinburgh Clinical Research Facility, University of Edinburgh, Western General Hospital, Edinburgh, UK
| | - Martin Dennis
- Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK
| |
Collapse
|