1
|
Ahn HS, Kim YK, Song HC, Choi EJ, Kim GH, Cho JS, Ihm SH, Kim HY, Park CS, Youn HJ. The impact of preload on 3-dimensional deformation parameters: principal strain, twist and torsion. Cardiovasc Ultrasound 2017; 15:22. [PMID: 28899401 PMCID: PMC5596939 DOI: 10.1186/s12947-017-0111-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Accepted: 09/01/2017] [Indexed: 12/20/2022] Open
Abstract
Background Strain analysis is feasible using three-dimensional (3D) echocardiography. This approach provides various parameters based on speckle tracking analysis from one full-volume image of the left ventricle; however, evidence for its volume independence is still lacking. Methods Fifty-eight subjects who were examined by transthoracic echocardiography immediately before and after hemodialysis (HD) were enrolled. Real-time full-volume 3D echocardiographic images were acquired and analyzed using dedicated software. Two-dimensional (2D) longitudinal strain (LS) was also measured for comparison with 3D strain values. Results Longitudinal (pre-HD: −24.57 ± 2.51, post-HD: −21.42 ± 2.15, P < 0.001); circumferential (pre-HD: −33.35 ± 3.50, post-HD: −30.90 ± 3.22, P < 0.001); and radial strain (pre-HD: 46.47 ± 4.27, post-HD: 42.90 ± 3.61, P < 0.001) values were significantly decreased after HD. The values of 3D principal strain (PS), a unique parameter of 3D images, were affected by acute preload changes (pre-HD: −38.10 ± 3.71, post-HD: −35.33 ± 3.22, P < 0.001). Twist and torsion values were decreased after HD (pre-HD: 17.69 ± 7.80, post-HD: 13.34 ± 6.92, P < 0.001; and pre-HD: 2.04 ± 0.86, post-HD:1.59 ± 0.80, respectively, P < 0.001). The 2D LS values correlated with the 3D LS and PS values. Conclusion Various parameters representing left ventricular mechanics were easily acquired from 3D echocardiographic images; however, like conventional parameters, they were affected by acute preload changes. Therefore, strain values from 3D echocardiography should be interpreted with caution while considering the preload conditions of the patients.
Collapse
Affiliation(s)
- Hyo-Suk Ahn
- Divisions of Cardiology, College of Medicine, Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea
| | - Yong-Kyun Kim
- Nephrology, College of Medicine, Catholic University of Korea, Seoul, South Korea
| | - Ho Chul Song
- Nephrology, College of Medicine, Catholic University of Korea, Seoul, South Korea
| | - Euy Jin Choi
- Nephrology, College of Medicine, Catholic University of Korea, Seoul, South Korea
| | - Gee-Hee Kim
- Divisions of Cardiology, College of Medicine, Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea
| | - Jung Sun Cho
- Divisions of Cardiology, College of Medicine, Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea
| | - Sang-Hyun Ihm
- Divisions of Cardiology, College of Medicine, Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea
| | - Hee-Yeol Kim
- Divisions of Cardiology, College of Medicine, Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea
| | - Chan Seok Park
- Divisions of Cardiology, College of Medicine, Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea.
| | - Ho-Joong Youn
- Divisions of Cardiology, College of Medicine, Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea
| |
Collapse
|