1
|
Bograd A, Himmel I, Pfister IB, Seiler TG, Frueh BE, Tappeiner C. Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device. Graefes Arch Clin Exp Ophthalmol 2024; 262:891-901. [PMID: 37688609 DOI: 10.1007/s00417-023-06219-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 07/25/2023] [Accepted: 08/26/2023] [Indexed: 09/11/2023] Open
Abstract
PURPOSE To assess the feasibility and reliability of biometric measurements taken with the Eyestar 900 device in keratoconus eyes in comparison with those taken with the Pentacam HR and IOLMaster 700. METHODS Seventy-five eyes of 75 patients with keratoconus were included. The central corneal thickness (CCT), thinnest point of corneal thickness (TCT), axial length (AL), flat (K1) and steep (K2) anterior and posterior (Kp1, Kp2) keratometry, maximal keratometry (KMax) and anterior chamber depth (ACD) were compared between the Eyestar 900, Pentacam HR and IOLMaster 700. Reliability parameters such as the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated. Pearson's r was determined to assess the correlation between devices. RESULTS A high repeatability (CoV < 1%) and intraclass correlation (ICC > 0.9) was found for all devices, led by AL, TCT, K1 and K2 (CoV 0.01-0.36%; ICC 0.994-1.00). The largest correlation between devices was found for AL (Eyestar vs. IOLMaster, r = 1.0), K1 (Eyestar vs. IOLMaster, r = 0.997) and ACD (Eyestar vs. IOLMaster, r = 0.995; Pentacam vs. IOLMaster, r = 0.987; Eyestar vs. Pentacam, r = 0.983), but there were significant differences in measured values between devices (p < 0.001), whereas the correlation was only slightly lower (r = 0.947 to 0.994) for KMax, CCT, TCT, K2, Kp1 and Kp2. CONCLUSION Keratometric and axial length measurements with the Eyestar 900 were feasible and revealed a high repeatability and a good correlation to the other devices in eyes with keratoconus.
Collapse
Affiliation(s)
- Alexandra Bograd
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.
- Berner Augenklinik, Bern, Switzerland.
- Department of Ophthalmology, Pallas Klinik, Olten, Switzerland.
| | - Isabelle Himmel
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
| | | | - Theo G Seiler
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
- Institut für Refraktive und Ophthalmo-Chirurgie (IROC), Zurich, Switzerland
- Klinik für Augenheilkunde, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
| | - Beatrice E Frueh
- Department of Ophthalmology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
| | - Christoph Tappeiner
- Department of Ophthalmology, Pallas Klinik, Olten, Switzerland
- Department of Ophthalmology, University Hospital Essen, University Duisburg-Essen, Essen, Germany
- Department of Ophthalmology, San Raffaele Scientific Institute, University Vita-Salute, Milan, Italy
- Medical Faculty, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Zheng F, Deng X, Zhang Q, He J, Ye P, Liu S, Li P, Zhou J, Fang X. Advances in swept-source optical coherence tomography and optical coherence tomography angiography. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH 2023; 3:67-79. [PMID: 37846376 PMCID: PMC10577875 DOI: 10.1016/j.aopr.2022.10.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 10/19/2022] [Accepted: 10/31/2022] [Indexed: 10/18/2023]
Abstract
Background The fast development of swept-source optical coherence tomography (SS-OCT) and swept-source optical coherence tomography angiography (SS-OCTA) enables both anterior and posterior imaging of the eye. These techniques have evolved from a research tool to an essential clinical imaging modality. Main text The longer wavelength and faster speed of SS-OCT and SS-OCTA facilitate better visualization of structure and vasculature below pigmented tissue with a larger field of view of the posterior segment and 360-degree visualization of the anterior segment. In the past 10 years, algorithms dealing with OCT and OCTA data also vastly improved the image quality and enabled the automated quantification of OCT- and OCTA-derived metrics. This technology has enriched our current understanding of healthy and diseased eyes. Even though the high cost of the systems currently limited the widespread use of SS-OCT and SS-OCTA at the first beginning, the gap between research and clinic practice got obviously shortened in the past few years. Conclusions SS-OCT and SS-OCTA will continue to evolve rapidly, contributing to a paradigm shift toward more widespread adoption of new imaging technology in clinical practice.
Collapse
Affiliation(s)
- Fang Zheng
- Eye Center, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China
| | - Xiaofeng Deng
- State Key Lab of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Qi Zhang
- Eye Center, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China
| | - Jingliang He
- Eye Center, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China
| | - Panpan Ye
- Eye Center, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China
| | - Shan Liu
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Peng Li
- State Key Lab of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Jian Zhou
- TowardPi (Beijing) Medical Technology Ltd, Shanghai, China
| | - Xiaoyun Fang
- Eye Center, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
3
|
Antunes-Foschini R, Doná H, de Mello PHS, Pereira RB, Marqueis IM, Rocha EM, de Faria-E-Sousa SJ, Perdona GC. Natural history and predictors for progression in pediatric keratoconus. Sci Rep 2023; 13:4940. [PMID: 36973341 PMCID: PMC10042985 DOI: 10.1038/s41598-023-32176-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 03/23/2023] [Indexed: 03/29/2023] Open
Abstract
We studied the demographic and clinical predictors associated with keratoconus progression in a pediatric population. Retrospective cohort study. We evaluated 305 eyes without previous surgeries from 168 patients, 9 to < 18 years old, and with a minimum 36-month follow-up in a hospital corneal ambulatory. We used Kaplan-Meyer survival curves; the dependent variable (main outcome measure) was the interval time (months) until the event, defined as an increase of 1.5 D in the maximum keratometry (Kmax), obtained with Pentacam. We evaluated the predictors: age (< or ≥ 14 years), sex, keratoconus familial history, allergy medical history, and the baseline tomographic parameters: mean keratometry (Km), Kmax (< or ≥ 55 D); and thinnest pachymetry (TP). We used log-rank tests and compared median survival times for right (RE)/left eyes (LE) and better (BE)/worse eyes (WE). A p value < 0.05 was considered significant. The patients' mean ± SD age was 15.1 ± 2.3 years old; 67% were boys, 30% were < 14 years, 15% had keratoconus familial history, and 70% were allergic. The general Kaplan-Meyer curves showed no differences between RE/LE or BE/WE. RE with allergy and LE with Kmax ≥ 55 D had smaller survival times ((95%CI 9.67-32.1), p 0.031 and (95%CI 10.1-44.1), p 0.042, respectively). For BE and WE, Kmax ≥ 55 D had smaller survival times ((95% CI 6.42- ), p 0.031 and (95%CI 8.75-31.8), p 0.043, respectively). Keratoconus progression was similar between RE/LE and BE/WE. Steepest corneas are predictors of faster progression. Allergy is also a predictor of keratoconus progression in RE.
Collapse
Affiliation(s)
- Rosalia Antunes-Foschini
- Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Av. Bandeirantes, 3900, Ribeirão Preto, SP, CEP 14049-900, Brazil.
| | - Henrique Doná
- Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Av. Bandeirantes, 3900, Ribeirão Preto, SP, CEP 14049-900, Brazil
| | - Pedro Henrique Sant'Anna de Mello
- Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Av. Bandeirantes, 3900, Ribeirão Preto, SP, CEP 14049-900, Brazil
| | - Renato Bredariol Pereira
- Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Av. Bandeirantes, 3900, Ribeirão Preto, SP, CEP 14049-900, Brazil
| | - Isadora Mendes Marqueis
- Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Av. Bandeirantes, 3900, Ribeirão Preto, SP, CEP 14049-900, Brazil
| | - Eduardo Melani Rocha
- Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Sidney Julio de Faria-E-Sousa
- Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Gleici Castro Perdona
- Department of Social Medicine, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, SP, Brazil
| |
Collapse
|
4
|
Mirzayev I, Gündüz AK, Aydın Ellialtıoğlu P, Gündüz ÖÖ. Clinical applications of anterior segment swept-source optical coherence tomography: A systematic review. Photodiagnosis Photodyn Ther 2023; 42:103334. [PMID: 36764640 DOI: 10.1016/j.pdpdt.2023.103334] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 01/25/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023]
Abstract
Optical coherence tomography (OCT) is a non-invasive method that provides the opportunity to examine tissues by taking cross-sectional images. OCT is increasingly being used to evaluate anterior segment (AS) pathologies. Swept-source (SS) OCT allows greater penetration and achieves better visualization of the internal configuration of AS tissues due to the longer wavelength employed and high scan speeds. We reviewed the utilization of AS SS-OCT in various conditions including glaucoma, ocular surface pathologies, iris tumors, refractive surgery, cataract surgery, and scleral diseases. A systematic literature search was carried out on PubMed, Scopus, and Web of Science databases between January 1, 2008, and September 1, 2022 using the following keywords: AS SS-OCT; dry eye and SS-OCT; ocular surface and SS-OCT; cornea and SS-OCT; dystrophy and SS-OCT; glaucoma and SS-OCT; ocular surface tumors and SS-OCT; conjunctival tumors and SS-OCT; refractive surgery and SS-OCT; cataract and SS-OCT; biometry and SS-OCT; sclera and SS-OCT; iris and SS-OCT; ciliary body and SS-OCT; artificial intelligence and SS-OCT. A total of 221 studies were included in this review. Review of the existing literature shows that SS-OCT offers several advantages in the diagnosis of AS diseases. Exclusive features of SS-OCT including rapid scanning, deeper tissue penetration, and better image quality help improve our understanding of various AS pathologies.
Collapse
Affiliation(s)
- Ibadulla Mirzayev
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Halil Şıvgın Çubuk State Hospital, Ophthalmology Clinic, Ankara, Turkey
| | - Ahmet Kaan Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey; Private Eye Clinic, Ankara, Turkey.
| | | | - Ömür Özlenen Gündüz
- Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
5
|
Seiler TG, Mueller M, Mendes Baiao T. Repeatability and Comparison of Corneal Tomography in Mild to Severe Keratoconus Between the Anterior Segment OCT MS-39 and Pentacam HR. J Refract Surg 2022; 38:250-255. [PMID: 35412926 DOI: 10.3928/1081597x-20220114-02] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To detect keratoconus progression, accuracy of tomographic measurements is crucial. The impoved axial resolution of optical coherence tomography (OCT) compared to Scheimpflug photography serves as the motivation to investigate and compare the repeatability of the anterior segment OCT MS-39 (CSO) to Pentacam HR (Oculus Optikgeräte GmbH) in patients with keratoconus. METHODS One hundred twenty-three eyes of 123 patients with keratoconus were enrolled and subdivided in four groups by maximum keratometry (Kmax): Kmax < 48.00 diopters (D), Kmax of 48.00 to 53.01 D, Kmax of 53.00 to 58.00 D, and Kmax > 58.00 D. Three consecutive measurements per eye were acquired with the MS-39 and compared to the Pentacam HR. Kmax, thinnest pachymetry, anterior asphericity, and posterior elevation data were compared. Within-subject standard deviation (Sw), coefficient of variation (CoV), test-retest repeatability (TRT), and the intra-class correlation (ICC) were calculated and evaluated. Bland-Altman plots were also analyzed. RESULTS The Pentacam HR measures significantly higher Kmax values than the MS-39, with a more pronounced difference for severe cases of keratoconus (0.57 D for all cases; 1.88 D for cases with Kmax > 58.00 D). Thinnest pachymetry was approximately 5 µm thinner when measured by the Pentacam HR than the MS-39, independently of keratoconus stage. A further progressed keratoconus stage was significantly associated with increased measurement errors and resulted in worse repeatability (Kmax < 48.00 D: Sw = 0.18 D, TRT = 0.50 D, CoV = 0.39%, ICC = 0.989; Kmax > 58.00 D: Sw = 0.53 D, TRT = 1.48 D, CoV = 0.90%, ICC = 0.984). The behavior was similar for other tomographic parameters. CONCLUSIONS The Pentacam HR and the MS-39 have an overall good agreement for keratoconus; however, the Pentacam HR measures steeper and thinner than the MS-39. The association between the magnitude of topographic and tomographic parameters and their measurement errors suggests that the diagnosis of keratoconus disease progression should be based on the stage and the test-retest repeatability rather than on a fixed value (eg, 1.00 D). [J Refract Surg. 2022;38(4):250-255.].
Collapse
|
6
|
Li Y, Gokul A, McGhee C, Ziaei M. Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus. PLoS One 2021; 16:e0248350. [PMID: 34143790 PMCID: PMC8213071 DOI: 10.1371/journal.pone.0248350] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Accepted: 02/24/2021] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To investigate the repeatability in corneal thickness (CT) and epithelial thickness (ET) measurements using spectral domain anterior segment optical coherence tomography (AS-OCT, REVO NX, Optopol) in keratoconus, and examine the effect of corneal crosslinking (CXL) on repeatability. METHODS A cross-sectional study of 259 eyes of 212 patients with keratoconus attending the corneal disease clinic at a university hospital tertiary referral center were enrolled. Two groups were analysed: eyes with no prior history of CXL (Group A) and eyes with prior CXL (Group B). Repeatability of measurements was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV). RESULTS In Group A, central corneal thickness (CCT) was 472.18 ± 45.41μm, and the ET was found to be the thinnest in the inferior-temporal aspect at 51.79 ± 5.97μm and thickest at the superior-nasal aspect at 56.07 ± 5.70μm. In Group B, CCT was 465.11± 42.28μm, and the ET was the thinnest at the inferior-temporal aspect at 50.63 ± 5.52μm and thickest at the superior aspect at 56.80 ± 6.39μm. When evaluating CT measurements, ICC was above 0.86 and 0.83 for Group A and Group B respectively. When evaluating ET measurements, ICC was above 0.82 for both groups. CXL had no statistically significant impact on the repeatability of measurements. CONCLUSIONS AS-OCT provides repeatable CT and ET measurements in the central and peripheral cornea in patients with keratoconus. Repeatability is not affected by a history of CXL.
Collapse
Affiliation(s)
- Ye Li
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Akilesh Gokul
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Charles McGhee
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Mohammed Ziaei
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
7
|
Li Y, Gokul A, McGhee C, Ziaei M. Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus. PLoS One 2021; 16:e0248659. [PMID: 34019547 PMCID: PMC8139453 DOI: 10.1371/journal.pone.0248659] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Accepted: 04/30/2021] [Indexed: 11/25/2022] Open
Abstract
Purpose To compare the repeatability and agreement in biometric measurements using Spectral Domain Anterior Segment OCT (AS-OCT, REVO-NX, Optopol) and Scheimpflug tomography (Pentacam-AXL, Oculus) in keratoconus. Methods Prospective case series at a university hospital tertiary center. Axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and thinnest corneal thickness (TCT) were measured using both devices in patients with keratoconus. Three groups were analyzed: eyes with no prior crosslinking or contact lens wear (Group A), eyes with prior crosslinking (Group B), and eyes with prior contact lens wear (Group C). Repeatability and agreement of measurements were analyzed. Results The study comprised of 214 eyes of 157 subjects. In Group A (n = 95 eyes), Group B (n = 86 eyes), and Group C (n = 33 eyes), intraclass correlation coefficient (ICC) was higher than 0.90 for all examined parameters, except for ACD readings in Group A with the REVO-NX (ICC = 0.83). Differences in ACD, TCT, and CCT were significantly different between the two devices for Groups A, B and C (p<0.05). AL measurements differed significantly in Groups A and B (p<0.05) but not in Group C (p = 0.18). Repeatability did not vary significantly between Groups A, B, or C in any parameter with both devices (p>0.05). There was poor agreement between the two devices across all parameters (p<0.05). Conclusions Both devices demonstrated good repeatability but poor agreement across AL, ACD, CCT and TCT measurements. There was no significant difference in repeatability in virgin eyes compared to eyes with prior crosslinking or contact lens wear, however, the interchangeable use of the two devices is not recommended.
Collapse
Affiliation(s)
- Ye Li
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Akilesh Gokul
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Charles McGhee
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Mohammed Ziaei
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
- * E-mail:
| |
Collapse
|
8
|
Karp CL, Mercado C, Venkateswaran N, Ruggeri M, Galor A, Garcia A, Sivaraman KR, Fernandez MP, Bermudez A, Dubovy SR. Use of High-Resolution Optical Coherence Tomography in the Surgical Management of Ocular Surface Squamous Neoplasia: A Pilot Study. Am J Ophthalmol 2019; 206:17-31. [PMID: 31163136 DOI: 10.1016/j.ajo.2019.05.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Revised: 05/07/2019] [Accepted: 05/28/2019] [Indexed: 12/18/2022]
Abstract
PURPOSE To evaluate whether high-resolution optical coherence tomography (HR-OCT) can detect histologic tumor margins of ocular surface squamous neoplasia (OSSN). METHODS Eight eyes of 8 patients with OSSN undergoing excision were studied prospectively. Immediately before surgery, the tumor was imaged using commercially available HR-OCT to identify the conjunctival margins of the neoplastic lesion. The tumor borders of the lesion determined by HR-OCT were mapped in relation to an anatomic reference point and transferred intraoperatively. The tumor was excised with 4-mm margins from the visible edge of the lesion with a "no-touch" technique. The specimens were sent for pathologic analysis and the histologic tumor margin was compared to the HR-OCT predicted tumor border. RESULTS Mean age of the 8 patients was 67 ± 9.9 years. Seven were male, 7 were white, and, ethnically, 3 were Hispanic. All 8 tumors were bulbar and in the exposure zone. Seven tumors were limbal. Corneal extension was present in 5. Mean tumor area was 17.5 ± 11.1 mm2. Clinically, 2 of the tumors were leukoplakic, 1 papillomatous, and 3 gelatinous. A conjunctival tumor margin identified with the HR-OCT coincided with the pathologically confirmed margin mark in all eyes. CONCLUSIONS HR-OCT has the potential to predict histologic tumor margins in OSSN. Optical identification of tumor margins could potentially decrease the incidence of residual positive margins and minimize healthy tissue removal. Advances in HR-OCT technology and integration into a microscope for "real-time" imaging are needed to further improve this technique. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.
Collapse
Affiliation(s)
- Carol L Karp
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA.
| | - Carolina Mercado
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Nandini Venkateswaran
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Marco Ruggeri
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Anat Galor
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA; Miami Veteran Affairs Medical Center, Miami, Florida, USA
| | - Armando Garcia
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Kavitha R Sivaraman
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Maria Paula Fernandez
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Antonio Bermudez
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Sander R Dubovy
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA; Florida Lions Ocular Pathology Laboratory, Miami, Florida, USA
| |
Collapse
|
9
|
Piccinini AL, Golan O, Torres-Netto EA, Hafezi F, Randleman JB. Corneal higher-order aberrations measurements: Comparison between Scheimpflug and dual Scheimpflug-Placido technology in keratoconic eyes. J Cataract Refract Surg 2019; 45:985-991. [PMID: 31029477 DOI: 10.1016/j.jcrs.2019.02.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 01/30/2019] [Accepted: 02/04/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE To compare the difference and agreement of corneal higher-order aberrations (HOAs) in keratoconic eyes using Scheimpflug and dual Scheimpflug-Placido imaging systems. SETTING Emory University, Atlanta, Georgia, and the University of Southern California, Los Angeles, California, USA. DESIGN Retrospective between-devices reliability and agreement study. METHODS Patients diagnosed with keratoconus were evaluated sequentially by Scheimpflug and dual Scheimpflug-Placido devices. Differences, correlations, and agreement between values for total root mean square (RMS), trefoil, coma, and spherical aberration were analyzed, and Bland-Altman plots were generated. RESULTS Fifty eyes from 50 patients (31 men, 19 women) were evaluated. Trefoil at 30 degrees, spherical aberration, and total RMS were significantly different between groups (P < .05), whereas trefoil at 0 degrees and total coma values were not statistically different. There was a weak positive correlation between devices for trefoil at 0 degrees (r = 0.228), and a moderate positive correlation for trefoil at 30 degrees (r = 0.473), horizontal coma (r = 0.430), and for total corneal RMS (r = 0.637). Vertical coma (r = 0.816) and spherical aberration (r = 0.874) showed a strong positive correlation. The 95% limits of agreement (LoA) for absolute values were 1.963 μm for trefoil at 30 degrees, 2.449 μm for trefoil at 0 degrees, 3.530 μm for horizontal coma, 2.145 μm for vertical coma, 1.242 μm for spherical aberration, and 10.527 μm for RMS. CONCLUSION Significant differences were found between measurements of corneal HOAs generated by Scheimpflug and dual Scheimpflug-Placido devices in patients with keratoconus, with generally limited correlations and wide LoA. HOAs measurements from these devices should not be considered equivalent.
Collapse
Affiliation(s)
- Andre L Piccinini
- Keck School of Medicine of the University of Southern California, Los Angeles, California, USA; Sadalla Amin Ghanem Eye Hospital, Joinville, SC, Brazil
| | - Oren Golan
- Keck School of Medicine of the University of Southern California, Los Angeles, California, USA; Department of Ophthalmology, Tel Aviv Souraski Medical Center, Israel
| | - Emilio A Torres-Netto
- Paulista School of Medicine, Federal University of São Paulo, Brazil; ELZA Institute, Dietikon/Zurich, Switzerland; Ocular Cell Biology Group, University of Zurich, Switzerland
| | - Farhad Hafezi
- Keck School of Medicine of the University of Southern California, Los Angeles, California, USA; USC Roski Eye Institute, Los Angeles, California, USA; ELZA Institute, Dietikon/Zurich, Switzerland; Ocular Cell Biology Group, University of Zurich, Switzerland; University of Wenzhou, China
| | - J Bradley Randleman
- Keck School of Medicine of the University of Southern California, Los Angeles, California, USA; USC Roski Eye Institute, Los Angeles, California, USA.
| |
Collapse
|
10
|
Comparing Change in Anterior Curvature After Corneal Cross-linking Using Scanning-slit and Scheimpflug Technology. Am J Ophthalmol 2018; 191:129-134. [PMID: 29729256 DOI: 10.1016/j.ajo.2018.04.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2018] [Revised: 04/19/2018] [Accepted: 04/20/2018] [Indexed: 10/17/2022]
Abstract
PURPOSE To evaluate the correlation between anterior axial curvature difference maps following corneal cross-linking (CXL) for progressive keratoconus obtained from Scheimpflug-based tomography and Placido-based topography. DESIGN Between-devices reliability analysis of randomized clinical trial data. METHODS Corneal imaging was collected at a single-center institution preoperatively and at 3, 6, and 12 months postoperatively using Scheimpflug-based tomography (Pentacam; Oculus Inc, Lynnwood, Washington, USA) and scanning-slit, Placido-based topography (Orbscan II; Bausch & Lomb, Rochester, New York, USA) in patients with progressive keratoconus receiving standard protocol CXL (3 mW/cm2 for 30 minutes). Regularization index (RI), absolute maximum keratometry (K Max), and change in K Max (ΔK Max) were compared between the 2 devices at each time point. RESULTS Fifty-one eyes from 36 patients were evaluated at all time points. Values were significantly different at all time points (56.01 ± 5.3 diopters [D] Scheimpflug vs 55.04 ± 5.1 D scanning-slit preoperatively [P = .003]; 54.58 ± 5.3 D Scheimpflug vs 53.12 ± 4.9 D scanning-slit at 12 months [P < .0001]) but strongly correlated between devices (r = 0.90-0.93) at all time points. The devices were not significantly different at any time point for either ΔK Max or RI but were poorly correlated at all time points (r = 0.41-0.53 for ΔK Max, r = 0.29-0.48 for RI). At 12 months, 95% limits of agreement were 7.51 D for absolute K Max, 8.61 D for ΔK Max, and 19.86 D for RI. CONCLUSIONS Measurements using Scheimpflug and scanning-slit Placido-based technology are correlated but not interchangeable. Both devices appear reasonable for separately monitoring the cornea's response to CXL; however, caution should be used when comparing results obtained with one measuring technology to the other.
Collapse
|
11
|
Módis L, Németh G, Szalai E, Flaskó Z, Seitz B. Scanning-slit topography in patients with keratoconus. Int J Ophthalmol 2017; 10:1686-1692. [PMID: 29181311 DOI: 10.18240/ijo.2017.11.08] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Accepted: 12/06/2016] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the anterior and posterior corneal surfaces using scanning-slit topography and to determine the diagnostic ability of the measured corneal parameters in keratoconus. METHODS Orbscan II measurements were taken in 39 keratoconic corneas previously diagnosed by corneal topography and in 39 healthy eyes. The central minimum, maximum, and astigmatic simulated keratometry (K) and anterior axial power values were determined. Spherical and cylindrical mean power diopters were obtained at the central and at the steepest point of the cornea both on anterior and on posterior mean power maps. Pachymetry evaluations were taken at the center and paracentrally in the 3 mm zone from the center at a location of every 45 degrees. Receiver operating characteristic (ROC) analysis was used to determine the best cut-off values and to evaluate the utility of the measured parameters in identifying patients with keratoconus. RESULTS The minimum, maximum and astigmatic simulated K readings were 44.80±3.06 D, 47.17±3.67 D and 2.42±1.84 D respectively in keratoconus patients and these values differed significantly (P<0.0001 for all comparisons) from healthy subjects. For all pachymetry measurements and for anterior and posterior mean power values significant differences were found between the two groups. Moreover, anterior central cylindrical power had the best discrimination ability (area under the ROC curve=0.948). CONCLUSION The results suggest that scanning-slit topography and pachymetry are accurate methods both for keratoconus screening and for confirmation of the diagnosis.
Collapse
Affiliation(s)
- László Módis
- Department of Ophthalmology, University of Debrecen, Medical and Health Science Center, Debrecen 4032, Hungary
| | - Gábor Németh
- Borsod-Abaúj-Zemplén County Hospital and University Teaching Hospital, Miskolc 3526, Hungary
| | - Eszter Szalai
- Department of Ophthalmology, University of Debrecen, Medical and Health Science Center, Debrecen 4032, Hungary
| | - Zsuzsa Flaskó
- Department of Ophthalmology, University of Debrecen, Medical and Health Science Center, Debrecen 4032, Hungary
| | - Berthold Seitz
- Department of Ophthalmology, Homburg Keratoconus Center, University of Saarland, Homburg/Saar 66424, Germany
| |
Collapse
|
12
|
Measurements of Corneal Thickness in Eyes with Pseudoexfoliation Syndrome: Comparative Study of Different Image Processing Protocols. JOURNAL OF HEALTHCARE ENGINEERING 2017; 2017:4315238. [PMID: 29081937 PMCID: PMC5610886 DOI: 10.1155/2017/4315238] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 08/07/2017] [Indexed: 11/17/2022]
Abstract
Purpose Comparative analysis of central and peripheral corneal thickness in PEX patients using three different imaging systems: Pentacam-Scheimpflug device, time-domain optical coherence tomography (OCT) Visante, and swept-source OCT Casia. Materials and Methods 128 eyes of 80 patients with diagnosed PEX were examined and compared with 112 normal, non-PEX eyes of 72 cataract patients. The study parameters included 5 measured zones: central and 4 peripheral (superior, inferior, nasal, and temporal). Results The mean CCT in eyes with PEX syndrome measured with all three instruments was thicker than that in normal eyes. Corneal thickness measurements in the PEX group were statistically significantly different between Pentacam and OCT Casia: central corneal thickness (p = 0.04), inferior corneal zone (p = 0.01), and nasal and temporal corneal zones (p < 0.01). Between Pentacam and OCT Visante inferior, nasal and temporal corneal zones were statistically significantly different (p < 0.01). Between OCT Casia and OCT Visante, there were no statistically significant differences in measured parameters values. Conclusion The central corneal thickness in eyes with PEX syndrome measured with three different independent methods is higher than that in the non-PEX group, and despite variable peripheral corneal thickness, this one parameter is still crucial in intraocular pressure measurements.
Collapse
|
13
|
Aghazadeh Amiri M, Hashemi H, Ramin S, Yekta A, Taheri A, Nabovati P, Khabazkhoob M. Corneal thickness measurements with Scheimpflug and slit scanning imaging techniques in keratoconus. J Curr Ophthalmol 2016; 29:23-27. [PMID: 28367522 PMCID: PMC5362393 DOI: 10.1016/j.joco.2016.09.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Revised: 09/14/2016] [Accepted: 09/18/2016] [Indexed: 10/25/2022] Open
Abstract
PURPOSE To determine the repeatability of corneal thickness measurements with Scheimpflug (Pentacam) and slit scanning (Orbscan) imaging techniques in different grades of keratoconus. METHODS This study was conducted as a cross-sectional research. Imaging with Orbscan and Pentacam was performed on patients with different grades of keratoconus. With each device, 3 measurements were taken at 10 min intervals. Repeatability indices in different grades of keratoconus were calculated for each device. RESULTS Seventy-four eyes of 42 keratoconus patients were enrolled. Repeatability index (RI) of central corneal thickness (CCT) measurements in keratoconus grade 1, 2, and 3, were 12.8, 9.9, and 24.2 with Pentacam, and 23.6, 26.3, and 59.3 with Orbscan, respectively. For the thinnest point, these figures were 9.6, 8.0, and 35.7 with Pentacam and 19.5, 16.6, and 26.8 with Orbscan, respectively. The 95% limit of agreement (LOA) between Pentacam and Orbscan in measuring CCT and thinnest point in grade 1 were -25.5-47.7 mic and -33.3-32.8 mic, respectively. These results for grade 2 were -9.8-50.6 mic and -26.2-43.7 mic, respectively. In grade 3, 95% LoA were -20-64.6 mic and -31.4-60.5 mic, respectively. CONCLUSIONS The results of this study showed that although repeated measurements of the CCT with Orbscan and Pentacam are strongly correlated, repeatability values of CCT measurements significantly decrease at more advanced grades of keratoconus. In all keratoconus grades, repeatability of CCT measurements was better with Pentacam than Orbscan. These findings indicate that corneal thickness readings have less validity in patients with advanced keratoconus.
Collapse
Affiliation(s)
- Mohammad Aghazadeh Amiri
- Department of Optometry, Faculty of Rehabilitation Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hassan Hashemi
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran; Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Shahroukh Ramin
- Department of Optometry, Faculty of Rehabilitation Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Abbasali Yekta
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Azadeh Taheri
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| | - Payam Nabovati
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Mehdi Khabazkhoob
- Department of Medical Surgical Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| |
Collapse
|
14
|
Aksoy Y, Kar T, Kaya A. Comment on: Intraocular pressure and anetrior segment anatomy after phacoemulsification surgery. Indian J Ophthalmol 2016; 64:99. [PMID: 26953037 PMCID: PMC4821135 DOI: 10.4103/0301-4738.178157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Yakup Aksoy
- Department of Ophthalmology, Girne Military Hospital, Kyrenia, Cyprus
| | | | | |
Collapse
|