1
|
Pecić S, Vićić M, Belča I, Stojadinović S, Nidžović B, Kurij L, Dević S. Physical wedge as a tool for radiochromic film calibration. Z Med Phys 2023:S0939-3889(23)00077-6. [PMID: 37393128 DOI: 10.1016/j.zemedi.2023.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/17/2023] [Accepted: 05/31/2023] [Indexed: 07/03/2023]
Abstract
Reliable calibration is one of the major challenges in using radiochromic films (RCF) for radiation dosimetry. In this study the feasibility of using dose gradients produced by a physical wedge (PW) for RCF calibration was investigated. The aim was to establish an efficient and reproducible method for calibrating RCF using a PW. Film strips were used to capture the wedge dose profile for five different exposures and the acquired scans were processed to generate corresponding net optical density wedge profiles. The proposed method was compared to the benchmark calibration, following the guidelines for precise calibration using uniform dose fields. The results of the benchmark comparison presented in this paper showed that using a single film strip for measuring wedge dose profile is sufficient for estimating a reliable calibration curve within the recorded dose range. Furthermore, the PW calibration can be extrapolated or extended by using multiple gradients for the optimal coverage of the desired calibration dose range. The method outlined in this paper can be readily replicated using the equipment and expertise commonly found in a radiotherapy center. Once the dose profile and central axis attenuation coefficient of the PW are determined, they can serve as a reference for a variety of calibrations using different types and batches of film. This investigation demonstrated that the calibration curves obtained with the presented PW calibration method are within the bounds of the measurement uncertainty evaluated for the conventional uniform dose field calibration method.
Collapse
Affiliation(s)
- Stevan Pecić
- Faculty of Physics, University of Belgrade, Studentski trg 12-16, Belgrade 11000, Serbia.
| | - Miloš Vićić
- Faculty of Physics, University of Belgrade, Studentski trg 12-16, Belgrade 11000, Serbia
| | - Ivan Belča
- Faculty of Physics, University of Belgrade, Studentski trg 12-16, Belgrade 11000, Serbia
| | - Strahinja Stojadinović
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas 75390, TX, United States
| | - Borko Nidžović
- Institute of Oncology and Radiology of Serbia, Pasterova 14, Belgrade 11000, Serbia
| | - Ljubomir Kurij
- University Clinical Center of Serbia, Center for Neurooncology, Gamma Knife, Koste Todorovića 4, Belgrade 11000, Serbia
| | - Slobodan Dević
- Medical Physics Unit, McGill University, Montreal H4A 3J1, QC, Canada; Department of Radiation Oncology, SMBD Jewish General Hospital, Montreal H3T 1E2, QC, Canada
| |
Collapse
|
2
|
Mahdavi SR, Mahmoudi A, Geraily G, Mostaar A, Esmaili G. Comparison of dosimetric characteristics of physical wedge and enhanced dynamic wedge in inhomogeneous medium using Monte Carlo simulations. ACTA ACUST UNITED AC 2021; 26:59-65. [PMID: 33948303 DOI: 10.5603/rpor.a2021.0012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 12/22/2020] [Indexed: 11/25/2022]
Abstract
Background Widely used physical wedges in clinical radiotherapy lead to beam intensity attenuation as well as the beam hardening effect, which must be considered. Dynamic wedges devised to overcome the physical wedges (PWs) problems result in dosimetry complications due to jaw movement while the beam is on. This study was aimed to investigate the usability of physical wedge data instead of enhanced dynamic wedge due to the enhanced dynamic wedge (EDW) dosimetry measurement hardships of Varian 2100CD in inhomogeneous phantom by Monte Carlo code as a reliable method in radiation dosimetry. Materials and methods A PW and EDW-equipped-linac head was simulated using BEAMnrc code. DOSXYZnrc was used for three-dimensional dosimetry calculation in the CIRS phantom. Results Based on the isodose curves, EDW generated a less scattered as well as lower penumbra width compared to the PW. The depth dose variations of PWs and EDWs were more in soft tissue than the lung tissue. Beam profiles of PW and EDW indicated good coincidence in all points, except for the heel area. Conclusion Results demonstrated that it is possible to apply PW data instead of EDW due to the dosimetry and commissioning hardships caused by EDW in inhomogeneous media.
Collapse
Affiliation(s)
- Seied Rabi Mahdavi
- Department of Medical Physics, Faculty of Medicine, Iran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Atefeh Mahmoudi
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Ghazale Geraily
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran
| | - Ahmad Mostaar
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Islamic Republic of Iran
| | | |
Collapse
|
3
|
Mehnati P, Biglari F, Jomehzadeh A. Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions. JOURNAL OF MEDICAL SIGNALS & SENSORS 2019; 9:117-122. [PMID: 31316905 PMCID: PMC6601223 DOI: 10.4103/jmss.jmss_36_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND The collimator scatter factor (Sc) is one of the most important parameters in monitor unit (MU) calculation. There are several factors that impact Sc values, including head structures, backscatter in dose monitoring chambers, and wedges. The objective of this study was to investigate the variation of Sc with different buildup cap materials, wall thickness of buildup caps, source-to-chamber distances (SCDs), ionization chambers, and wedge angles in 6 MV photon beam. METHODS In this study, copper and Perspex buildup caps were made with two different thicknesses for each buildup cap. Measurements were performed on an Elekta Compact medical linear accelerator (6 MV) using RK dosimeter with a sensitive volume of 0.120 cm3 and Farmer-type ion chamber with a sensitive volume of 0.65 cm3. In all measurements, buildup caps and ionization chambers were positioned such as to stand vertically to the beam central axis. It was also investigated the effect of internal wedge with different angles (30° and 60°) different SCDs on Sc. RESULTS It was found in large field sizes, Sc values in Perspex buildup cap were higher than copper. Different SCDs and type of ion chamber and wall thickness of buildup caps had no significant influence on Sc values. The presence of wedge influenced Sc values significantly. Variation of Sc in wedged fields compared to open fields had a maximum deviation of 0.9% and 6.8% in 30° and 60° wedge angles, respectively. CONCLUSION It was found that the presence of wedges had a significant influence on Sc and increases with wedge angles. As such, it should be taken into account in manual MU calculations.
Collapse
Affiliation(s)
- Parinaz Mehnati
- Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Farideh Biglari
- Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ali Jomehzadeh
- Department of Medical Physics, School of Paramedical, Kerman University of Medical Sciences, Kerman, Iran
| |
Collapse
|
4
|
Majer M, Stolarczyk L, De Saint-Hubert M, Kabat D, Kneževic Ž, Miljanic S, Mojzeszek N, Harrison R. OUT-OF-FIELD DOSE MEASUREMENTS FOR 3D CONFORMAL AND INTENSITY MODULATED RADIOTHERAPY OF A PAEDIATRIC BRAIN TUMOUR. RADIATION PROTECTION DOSIMETRY 2017; 176:331-340. [PMID: 28338841 DOI: 10.1093/rpd/ncx015] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Accepted: 01/29/2017] [Indexed: 05/03/2023]
Abstract
The purpose of this study was to measure out-of-field organ doses in clinical conditions in anthropomorphic paediatric phantoms which received a simulated treatment of a brain tumour with intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy (3D CRT). Organ doses measured with radiophotoluminescent and thermoluminescent dosemeters were on average 1.6 and 3.0 times higher for the 5 y-old than for the 10 y-old phantom for IMRT and 3D CRT, respectively. A larger 5-y to 10-y organ dose ratio for 3D CRT can be explained because the use of a mechanical wedge for the 5-y-old 3D CRT phantom treatment increased out-of-field doses. Due to different configurations of the radiation fields, for both phantoms, the IMRT technique resulted in a higher non-target brain dose and higher eye doses but lower thyroid doses compared to 3D CRT. For 3D CRT (which used a non-coplanar field configuration), eye doses were 3-6% and for IMRT (which used a coplanar field configuration) 27-30% of the treatment dose, respectively. For thyroid and more distant organs, doses were less than 1% of the treatment dose. Comparison of measured doses and doses calculated by the treatment planning system (TPS) showed that the TPS underestimated out-of-field doses both for IMRT and 3D CRT.
Collapse
Affiliation(s)
- Marija Majer
- Ruder Boškovic Institute, Bijenicka cesta 54, 10000 Zagreb, Croatia
| | - Liliana Stolarczyk
- Institute of Nuclear Physics PAN, Radzikowskiego 152, 31-342 Krakow, Poland
| | | | - Damian Kabat
- Centre of Oncology M. Sklodowska-Curie Memorial Institute, Garncarska 11, 31-115 Krakow, Poland
| | - Željka Kneževic
- Ruder Boškovic Institute, Bijenicka cesta 54, 10000 Zagreb, Croatia
| | - Saveta Miljanic
- Ruder Boškovic Institute, Bijenicka cesta 54, 10000 Zagreb, Croatia
| | - Natalia Mojzeszek
- Institute of Nuclear Physics PAN, Radzikowskiego 152, 31-342 Krakow, Poland
| | - Roger Harrison
- University of Newcastle, Faculty of Medical Sciences, Newcastle upon Tyne NE2 4HH, UK
| |
Collapse
|
5
|
Zabihzadeh M, Birgani MJT, Hoseini-Ghahfarokhi M, Arvandi S, Hoseini SM, Fadaei M. Dosimetric Characteristics of 6 MV Modified Beams by Physical Wedges of a Siemens Linear Accelerator. Asian Pac J Cancer Prev 2017; 17:1685-9. [PMID: 27221838 DOI: 10.7314/apjcp.2016.17.4.1685] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Physical wedges still can be used as missing tissue compensators or filters to alter the shape of isodose curves in a target volume to reach an optimal radiotherapy plan without creating a hotspot. The aim of this study was to investigate the dosimetric properties of physical wedges filters such as off-axis photon fluence, photon spectrum, output factor and half value layer. The photon beam quality of a 6 MV Primus Siemens modified by 150 and 450 physical wedges was studied with BEAMnrc Monte Carlo (MC) code. The calculated present depth dose and dose profile curves for open and wedged photon beam were in good agreement with the measurements. Increase of wedge angle increased the beam hardening and this effect was more pronounced at the heal region. Using such an accurate MC model to determine of wedge factors and implementation of it as a calculation algorithm in the future treatment planning systems is recommended.
Collapse
Affiliation(s)
- Mansour Zabihzadeh
- Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran E-mail :
| | | | | | | | | | | |
Collapse
|
6
|
Njeh CF. Enhanced dynamic wedge output factors for Varian 2300CD and the case for a reference database. J Appl Clin Med Phys 2015; 16:271–283. [PMID: 26699307 PMCID: PMC5690176 DOI: 10.1120/jacmp.v16i5.5498] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2014] [Revised: 04/29/2015] [Accepted: 04/20/2015] [Indexed: 11/23/2022] Open
Abstract
Dose inhomogeneity in treatment planning can be compensated using physical wedges. Enhanced dynamic wedges (EDW) were introduced by Varian to overcome some of the shortcomings of physical wedges. The objectives of this study were to measure EDW output factors for 6 MV and 20 MV photon energies for a Varian 2300CD. Secondly, to review the literature in terms of published enhanced dynamic wedge output factors (EDWOF) for different Varian models and thereby add credence to the case of the validity of reference databases. The enhanced dynamic wedge output factors were measured for the Varian 2300CD for both 6MV and 20 MV photon energies. Twelve papers with published EDWOF for different Varian linac models were found in the literature. Comparing our results with the published mean, we found an excellent agreement for 6 MV EDWOF, with the percentage differences ranging from 0.01% to 0.57%, with a mean of 0.03%. The coefficient of variation of published EDWOF ranged from 0.17% to 0.85% and 0.1% to 0.9% for the for 6 MV and 18 MV photon energies, respectively. This paper provides the first published EDWOF for 20 MV photon energy. In addition, we have provided the first compendium of EDWOFs for different Varian linac models. The consistency of value across models and institution provide further support that a standard dataset of basic photon and electron dosimetry could be established as a guide for future commissioning, beam modeling, and quality assurance purposes.
Collapse
|
7
|
Dawod T. Treatment planning validation for symmetric and asymmetric motorized wedged fields. INTERNATIONAL JOURNAL OF CANCER THERAPY AND ONCOLOGY 2015. [DOI: 10.14319/ijcto.0301.18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
8
|
Comparison of CCC and ETAR dose calculation algorithms in pituitary adenoma radiation treatment planning; Monte Carlo evaluation. JOURNAL OF RADIOTHERAPY IN PRACTICE 2014. [DOI: 10.1017/s1460396914000211] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractAimsTo verify the accuracy of two common absorbed dose calculation algorithms in comparison to Monte Carlo (MC) simulation for the planning of the pituitary adenoma radiation treatment.Materials and methodsAfter validation of Linac's head modelling by MC in water phantom, it was verified in Rando phantom as a heterogeneous medium for pituitary gland irradiation. Then, equivalent tissue-air ratio (ETAR) and collapsed cone convolution (CCC) algorithms were compared for a conventional three small non-coplanar field technique. This technique uses 30 degree physical wedge and 18 MV photon beams.ResultsDose distribution findings showed significant difference between ETAR and CCC of delivered dose in pituitary irradiation. The differences between MC and dose calculation algorithms were 6.40 ± 3.44% for CCC and 10.36 ± 4.37% for ETAR. None of the algorithms could predict actual dose in air cavity areas in comparison to the MC method.ConclusionsDifference between calculation and true dose value affects radiation treatment outcome and normal tissue complication probability. It is of prime concern to select appropriate treatment planning system according to our clinical situation. It is further emphasised that MC can be the method of choice for clinical dose calculation algorithms verification.
Collapse
|
9
|
Oh SA, Kim SK, Kang MK, Yea JW, Kim EC. Dosimetric verification of enhanced dynamic wedges by a 2D ion chamber array. JOURNAL OF THE KOREAN PHYSICAL SOCIETY 2013; 63:2215-2219. [DOI: 10.3938/jkps.63.2215] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/03/2023]
|
10
|
Muhammad W, Maqbool M, Shahid M, Hussain A, Tahir S, Matiullah, Rooh G, Ahmad T, Lee SH. Assessment of computerized treatment planning system accuracy in calculating wedge factors of physical wedged fields for 6 MV photon beams. Phys Med 2010; 27:135-43. [PMID: 20655782 DOI: 10.1016/j.ejmp.2010.06.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2009] [Revised: 05/10/2010] [Accepted: 06/25/2010] [Indexed: 10/19/2022] Open
Abstract
Wedge filters are commonly used in external beam radiotherapy to achieve a uniform dose distribution within the target volume. The main objective of this study was to investigate the accuracy of the beam modifier algorithm of Theraplan plus (TPP version 3.8) treatment planning system and to confirm that either the beam hardening, beam softening and attenuation coefficients along with wedge geometry and measured wedge factor at single depth and multiple fields sizes can be the replacement of wedged profile and wedged cross-sectional data or not. In this regard the effect of beam hardening and beam softening was studied with physical wedges for 6 MV photons. The Normalized Wedge Factors (NWFs) were measured experimentally as well as calculated with the Theraplan plus, as a function of depth and field size in a water phantom for 15°, 30°, 45°, and 60° wedge filters. The beam hardening and softening was determined experimentally by deriving the required coefficients for all wedge angles. The TPP version 3.8 requires wedge transmission factor at single depth and multiple field sizes. Without incorporating the hardening and softening coefficients the percent difference between measured and calculated NFWs was as high as 7%. After the introduction of these parameters into the algorithm, the agreement between measured and TPP (V 3.8) calculated NWFs were improved to within 2 percent for various depths. Similar improvement was observed in TPP version 3.8 while calculating NWFs for various field sizes when the required coefficients were adjusted. In conclusion, the dose calculation algorithm of TPP version 3.8 showed good accuracy for a 6 MV photon beam provided beam hardening and softening parameters are taken into account. From the results, it is also concluded that, the beam hardening, beam softening and attenuation coefficients along with wedge geometry and measured wedge factor at single depth and multiple fields sizes can be the replacement of wedged profile and wedged cross-sectional data in the TPS. The study also indicated that by ignoring the beam softening and beam hardening will result in an inaccurate dose to the target volume of the patient.
Collapse
Affiliation(s)
- Wazir Muhammad
- Department of Physics, Kyungpook National University, Daegu 702-701, Republic of Korea.
| | | | | | | | | | | | | | | | | |
Collapse
|