1
|
Alsahhaf A. Efficacy of canal disinfectants Temoporfin, carbon nanoparticles, and Er: YAG laser on martens hardness, smear layer removal, and bond strength of glass fiber posts to canal dentin. Photodiagnosis Photodyn Ther 2025; 52:104490. [PMID: 39827934 DOI: 10.1016/j.pdpdt.2025.104490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2024] [Revised: 01/14/2025] [Accepted: 01/17/2025] [Indexed: 01/22/2025]
Abstract
AIM To investigate the effectiveness of unconventional post space disinfection techniques, specifically Er:YAG laser, Temoporfin, and Carbon Nanoparticles (CNPs), in improving Martens hardness (MH), eliminating the smear layer (SL), and enhancing the push-out bond strength (PBS) of glass fiber posts in canal dentin. METHODS An in vitro study was conducted utilizing 80 single-rooted extracted human teeth, which were decoronated and subjected to standardized root canal preparation. The teeth were equally distributed into four experimental groups: Group 1 (NaOCl + EDTA), Group 2 (Er: YAG laser + EDTA), Group 3 (Temoporfin + EDTA), and Group 4 (CNPs + EDTA). Each group underwent disinfection protocols followed by assessment of Martens hardness (MH) using nanoindentation testing, SL evaluation via scanning electron microscopy, and bond strength testing using a universal testing machine (UTM). Statistical analysis was performed using one-way ANOVA followed by Tukey's post hoc test to determine the level of significance among the groups. A significant level of p<0.05 was established. RESULTS Group 4 (CNPs+17 % EDTA) showed a high MH value of (0.25 ± 0.02 GPa), significantly outperforming Groups 1 (0.13 ± 0.02 GPa) and 3 (0.10 ± 0.03 GPa). Group 2 (Er: YAG laser + 17 % EDTA) demonstrated superior smear layer removal across all sections, particularly in the apical third (1.94 ± 0.38). Push-out bond strength was highest in Group 2 (9.98 ± 0.14 MPa at the cervical level) and Group 4 (10.08 ± 0.21 MPa), while Group 1 showed a decrease in apical bond strength of (5.11 ± 0.19 MPa) CONCLUSION: CNPs and Er:YAG laser treatments, in comparison to Temoporfin and NaOCl, significantly increase dentin hardness and bond strength while reducing SL. This finding suggests that the incorporation of these innovative disinfection methods into endodontic procedures may enhance the durability and success of glass fiber post restorations.
Collapse
Affiliation(s)
- Abdulaziz Alsahhaf
- Department of Prosthetic Dental Sciences, College of Dentistry. King Saud University. Riyadh, PO Box-60169, Saudi Arabia.
| |
Collapse
|
2
|
Alsunbul H, Almutairi B, Aljanakh M, Abduljabbar T. Hybrid ceramic repair strength, surface roughness, and bond failure, using methylene blue-activated low-level laser therapy, Carbon dioxide, and Ti: Al 2O 3 laser. Photodiagnosis Photodyn Ther 2023; 43:103693. [PMID: 37419190 DOI: 10.1016/j.pdpdt.2023.103693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 06/25/2023] [Accepted: 07/05/2023] [Indexed: 07/09/2023]
Abstract
AIMS To evaluate the impact of various pretreatment regimes (LLLT, Ti-sapphire laser, CO2, and HFA-S) on hybrid ceramics, specifically focusing on their ability to enhance repair strength and minimize surface roughness (Ra). MATERIAL AND METHODS Discs were made from hybrid ceramics and after disinfection were randomly divided into four groups based on different surface conditioning techniques. Each group consisted of 15 discs, resulting in a total sample size of 60. dics in group 1 was surface treated with Low-level laser therapy (LLLT) using methylene blue (MB), Discs in group 2 with Ti-sapphire laser, Discs in group 3 with CO2 laser, and discs in group 4 with HFA-S. Five samples from each group were assessed for Ra. The remaining 10 samples from each group underwent repair using a porcelain repair kit in adherence to the planned instructions. The bond strength of each sample in all groups was measured using a universal testing machine. Following the bond strength testing, the specimens from all study groups were analyzed to determine the mode of failure. To evaluate the data, a two-way analysis of variance (ANOVA) was used, followed by post hoc multiple comparisons. RESULTS The highest repair bond strength was observed in group 4 hybrid ceramics pretreated with HFA-S (19.05±0.79 MPa). The lowest repair bond scores were observed in group 1 hybrid ceramics preconditioned with LLLT in the presence of Photosensitizer (13.41±0.36 MPa). The highest Ra scores were exhibited in group 2 surface treated with Ti-sapphire laser (0.0515±0.16 µm) and the lowest Ra scores were observed in Group 4 HFA-S (0.0311±0.79 µm). Predominant bond failure among different investigated groups was cohesive. CONCLUSION The current gold standard for hybrid ceramic conditioning is the use of hydrofluoric acid (HFA) combined with a silane coupling agent. Low-level laser therapy with methylene blue photosensitizer is not recommended for the treatment of hybrid ceramics.
Collapse
Affiliation(s)
- Hanan Alsunbul
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Basil Almutairi
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Mohammad Aljanakh
- Department of Restorative Dentistry, College of Dentistry, University of Ha'il, Hail 55473, Saudi Arabia
| | - Tariq Abduljabbar
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
| |
Collapse
|
3
|
Vohra F, Alsaif R, Alsayed H, AlSaeed MM, Mourad AME. Decontamination of lithium disilicate ceramics using various photosensitizers, herbal and chemical disinfectants, and the effect of surface conditioners on bond strength values. Photodiagnosis Photodyn Ther 2023:103619. [PMID: 37209762 DOI: 10.1016/j.pdpdt.2023.103619] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/11/2023] [Accepted: 05/15/2023] [Indexed: 05/22/2023]
Abstract
AIM To assess and compare the antimicrobial efficacy of disinfectants on lithium disilicate ceramic (LDC) used in dental applications and shear bond strength (SBS) of LDC after using different conditioners hydrofluoric acid (HF), self-etching ceramic primers (SECP) and Neodymium-doped yttrium orthovanadate (Nd: YVO4). MATERIALS AND METHODS One hundred and twenty LDC discs were fabricated by auto-polymerizing acrylic resin using the lost wax technique. S. aureus, S. mutans, and C. albican were inoculated on thirty discs (n=30 each). Each group was further divided into three subgroups based on different disinfecting agents used (n=30) Group 1: Garlic extract, Group 2: Rose Bengal (RB) activated by PDT, and Group 3: Sodium hypochlorite (NaOCl). An assessment of the survival rate of microorganisms was performed. The remaining thirty samples were surface treated using three different LDC surface conditioners (n=10) Group 1: HF + Silane (S), group 2: SECP, and Group 3: Nd: YVO4 laser+S. SBS and failure mode analysis were performed using a universal testing machine and stereomicroscope at 40x magnification, The statistical analysis was conducted using one-way ANOVA and Post Hoc Tukey test. RESULTS Garlic extract, RB, and 2% NaOCl sample displayed comparable outcomes of antimicrobial potency against C. albicans, S aureus, and S. mutans (p>0.05). Furthermore, SBS analysis showed HF+S, SECP, and Nd: YVO4+S exhibited comparable outcomes of bond strength (p>0.05). CONCLUSION Garlic extract and Rose bengal activated by PDT can be contemplated as alternatives to the chemical agent NaOCl used for LDC disinfection. Similarly, SECP and Nd: YVO4 possess the potential to be used for the surface conditioning of LDC to improve the bond integrity with resin cement.
Collapse
Affiliation(s)
- Fahim Vohra
- Prosthetic dental sciences, college of dentistry, King Saud university.
| | - Rawan Alsaif
- Prosthetic dental sciences, college of dentistry, King Saud university.
| | - Hussain Alsayed
- Prosthetic dental sciences, college of dentistry, King Saud university.
| | - Mojahid M AlSaeed
- University Dental Hospital King Saud University P.O Box 60169, Riyadh 11545, Saudi Arabia.
| | | |
Collapse
|
4
|
Souza JCM, Raffaele-Esposito A, Carvalho O, Silva F, Özcan M, Henriques B. Surface modification of zirconia or lithium disilicate-reinforced glass ceramic by laser texturing to increase the adhesion of prosthetic surfaces to resin cements: an integrative review. Clin Oral Investig 2023:10.1007/s00784-023-05016-z. [PMID: 37069409 DOI: 10.1007/s00784-023-05016-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 04/02/2023] [Indexed: 04/19/2023]
Abstract
OBJECTIVE The purpose of this study was to perform an integrative review on laser texturing the inner surface of lithium disilicate-reinforced glass ceramic or zirconia to increase their bond strength to resin-matrix cements. MATERIALS AND METHOD A bibliographic review was performed on PubMed using the following search terms: "zirconia" OR "lithium disilicate" AND "laser" AND "surface" OR "roughness" AND "bond strength" AND "luting agent" OR "resin cement." Studies published in English language until March 15, 2023, were selected regarding the purpose of this study. RESULTS A total of fifty-six studies were identified althoug thirteen studies were selected. The findings revealed that zirconia surfaces were significantly modified after laser irradiation resulting in macro-scale aligned retentive regions with depth values ranging from 50 to 120 µm. Average roughness values of laser-textured zirconia by Er,Cr:YSGG laser (~ 0.83 µm) were quite similar when compared to grit-blasted zirconia surfaces (~ 0.9 µm) although roughness increased up to 2.4 µm depending on the laser type and parameters. Lithium disilicate-reinforced glass ceramics textured with Er:YAG revealed an average roughness of around 3.5 µm while surfaces textured using Nd:YAG laser revealed an average roughness of 2.69 µm; that was quite similar to the roughness values recorded for etched surfaces (2.64 µm). The shear bond strength (SBS) values of zirconia surfaces textured on Nd:YVO4 laser irradiation were slightly higher (~ 33.5 MPa) than those recorded for grit-blasted zirconia surfaces (28 MPa). Laser-textured zirconia surfaces on CO2 laser revealed higher SBS values (18.1 ±0.8 MPa) than those (9.1 ± 0.56 MPa) recorded for untreated zirconia surfaces. On lithium disilicate-reinforced glass ceramics, higher SBS values to resin-matrix cements were recorded for specimens textured with a combination of fractional CO2 laser irradiation and HF acid etching (~ 22-24 MPa) when compared with grit-blasted specimens (12.2 MPa). Another study revealed SBS values at around 27.5 MPa for Er:YAG-textured lithium disilicate-reinforced glass ceramics to resin-matrix cements. CONCLUSIONS The laser irradiation at high power increases the roughness of the inner surface of lithium disilicate-reinforced glass ceramic or zirconia leading to an enhanced bond strength to resin-matrix cements. Thus, the laser type and irradiation parameters can be adjusted to enhance the macro- and micro-scale retention of zirconia and glass ceramic surfaces to resin-matrix cements. CLINICAL RELEVANCE Alternative methods for surface modification of lithium disilicate-reinforced glass ceramic and zirconia surfaces have been assessed to provide proper morphological aspects for enhanced adhesion to resin-matrix cements. An increase in the bond strength of glass ceramics or zirconia to resin-matrix cements can improve the long-term performance of cemented prosthetic structures in the oral cavity.
Collapse
Affiliation(s)
- Júlio C M Souza
- Center for Microelectromechanical Systems (CMEMS), University of Minho, Campus de Azurém, 4800-058, Guimarães, Portugal.
- LABBELS Associate Laboratory, University of Minho, 4710-057, Guimarães, Portugal.
- University Institute of Health Sciences (IUCS), CESPU, Gandra, PRD, 4585-116, Portugal.
| | | | - Oscar Carvalho
- Center for Microelectromechanical Systems (CMEMS), University of Minho, Campus de Azurém, 4800-058, Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4710-057, Guimarães, Portugal
| | - Filipe Silva
- Center for Microelectromechanical Systems (CMEMS), University of Minho, Campus de Azurém, 4800-058, Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4710-057, Guimarães, Portugal
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center of Dental Medicine, Clinic of Reconstructive Dentistry, University of Zurich, 8032, Zurich, Switzerland.
| | - Bruno Henriques
- Center for Microelectromechanical Systems (CMEMS), University of Minho, Campus de Azurém, 4800-058, Guimarães, Portugal
- Ceramic and Composite Materials Research Group (CERMAT), Department of Mechanical Engineering (EMC), Federal University of Santa Catarina (UFSC), Florianópolis, SC, 88040-900, Brazil
| |
Collapse
|
5
|
Ranjzad H, Heidari B, Rad FO, Hendi A, Ghorbani Z. Evaluation of Effect of Zirconia Surface Treatment with CO 2 and Nd:YAG Lasers on Shear Bond Strength between Zirconia Frameworks and Porcelain Veneers. J Contemp Dent Pract 2022; 23:1026-1032. [PMID: 37073917 DOI: 10.5005/jp-journals-10024-3412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
AIM The purpose of this study was to evaluate the effect of zirconia surface treatment with CO2 and Nd:YAG laser on shear bond strength (SBS) between the zirconia framework and porcelain veneering. MATERIALS AND METHODS In this in vitro study, zirconia blocks were converted to 50 cubes and were divided randomly into 5 groups. After sintering (S), porcelain was applied in the control group. The surface treatment of the second to fifth groups included CO2 laser + (S), (S + CO2), Nd:YAG laser + (S), and (S + Nd), respectively. The SBS test was done, and data were analyzed by SPSS16 software. One sample was randomly chosen from each group and the type of failure was examined under scanning electron microscope (SEM). To compare the pairs of means, the least significant difference test was used and the determined significance level was 5% (p < 0.05). RESULTS The SBS of S + Nd group was significantly higher than the other ones, except for S + CO2 group. The least amount of SBS belonged to CO2 + S and the highest to S + Nd group. There were no significant differences between the other groups. CONCLUSION The bond strength of veneering porcelain to zirconia can be altered by surface treatments. It can also be affected by the type and sequence of laser and sintering application. The effect of Nd:YAG laser on the surface of zirconia, in order to create roughness to increase SBS, is better than that of CO2 laser. CLINICAL SIGNIFICANCE Surface treatment of zirconia by certain types of lasers reduces the chipping of the ceramic veneer and increases the success rate of all-ceramic restorations.
Collapse
Affiliation(s)
- Hadi Ranjzad
- Department of Prosthodontics, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | | | - Farzane Ostovar Rad
- Department of Maxillofacial Radiology, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Amirreza Hendi
- Department of Prosthodontics, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Zahra Ghorbani
- Department of Prosthodontics, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran, Phone: +0098 9120248577, +0098 1332119328; e-mail:
| |
Collapse
|
6
|
Abdulla MA, Hasan RH. Shear Bond Strength of Two Repair Systems to Zirconia Ceramic by Different Surface Treatments. J Lasers Med Sci 2022; 13:e31. [PMID: 36743152 PMCID: PMC9841374 DOI: 10.34172/jlms.2022.31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 06/29/2022] [Indexed: 11/22/2022]
Abstract
Introduction: Intraoral repair has been suggested as a treatment option to repair the chipping or fracture of veneered zirconia; the success of the procedure is mainly determined by the bonding between zirconia and composite resin. The present study aimed to investigate and compare the shear bond strength (SBS) of two intraoral repair systems to zirconia ceramic treated with a laser or air-abrasion surface modification. Methods: Ninety tube-shaped samples (diameter of 10 mm and height of 4 mm) were divided into three main groups: Group I (zirconia 100%, n=30); Group II (veneer ceramic 100% n=30); Group III (zirconia with a veneer ceramic n=30). Each main group was subdivided into two subgroups (n=15): Subgroup A: samples repaired with Ceramic Repair N; Subgroup B: samples repaired with the Cimara Repair System. The subgroup samples were further subdivided based on the treated surface (n=5 samples): Control (no surface modification), Er,Cr:YSGG laser surface modification, and air-abrasion surface modification. The SBS was employed using a universal testing machine. The mode of failure was observed using a stereomicroscope. Results: Significant differences were observed in the mean SBS values between the different surface modifications (P˂0.05). Tukey's post hoc test showed that the air-abrasion surface modification of the veneer ceramic repaired with the Ceramic repair N system had the highest mean value (13.74 MPa) among the different groups, while no surface modification of zirconia repaired with the Cimara repair system had the lowest mean value (2.84 MPa). The control group (no surface modification) had the lowest mean value among all the treated groups. Conclusion: The SBS is surface modification-dependent, and higher SBS is obtained by air-abrasion than Er, Cr:YSGG laser surface modifications with the selected parameters. The Ceramic repair N system had significantly higher SBS for all surface-treated substrates than the Cimara repair system.
Collapse
Affiliation(s)
- Mohammed A Abdulla
- Department of Prosthetic Dentistry, College of Dentistry, Mosul University, Mosul, Iraq
| | | |
Collapse
|
7
|
Ali S, Zaki A, Maher R, Harhash T. Effect of Er,Cr: YSGG Laser on Bonding of Laminate Veneers using CAD/CAM (In Vitro Study). Open Access Maced J Med Sci 2022. [DOI: 10.3889/oamjms.2022.9356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIM: This in vitro study was designed to evaluate the shear bond strength after bonding between porcelain laminate veneers and the tooth surface using different etching methods
METHODS: Thirty freshly extracted maxillary premolars were used and prepared for receiving Enamic laminate veneers. Specimens were divided into two groups (n = 15), according to the surface treatment protocol. The specimens were sandblasted with 50 μm Al2O3 for 20 s; 2 bar pressure was maintained for air abrasion. Distribution of groups was as follow G1: Prepared enamel surface treatment of each tooth was according to the manufacturer’s instructions. G2: The prepared enamel surface of each tooth was subjected to Erbium,Chromium-Doped: Yttrium, Scandium, Gallium, and Garnet laser application. Light cured adhesive resin cement was applied to fitting surface of each ceramic specimen. To simulate thermal aging, the samples were subjected to 5000 thermal cycling in a thermocycler. By dividing the failure load (N) by the bonding area (mm2), debonding loads were calculated as shear stress (MPa). Numerical data were presented as mean and standard deviation values. They were explored for normality by checking the data distribution using Shapiro–Wilk test. Data showed parametric distribution and were analyzed using independent t-test. The significance level was set at p ≤ 0.05 within all tests. Statistical analysis was performed with R statistical analysis software version 4.1.2 for Windows.
RESULTS: Group (II) (15.84 ± 3.09) had significantly higher mean value than group (I) (13.69 ± 2.36) (t = 2.15, p = 0.041).
CONCLUSION: Within the limitation of this study, it was revealed that the laser surface treatment for tooth substrate plays a significant role in increasing the shear bond strength of laminate veneers.
Collapse
|
8
|
Abdulsatar AM, Hussein BMA, Mahmood AM. Effects of Different Laser Treatments on Some Properties of the Zirconia-Porcelain Interface. J Lasers Med Sci 2021; 12:e2. [PMID: 34084728 DOI: 10.34172/jlms.2021.02] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: This study was performed to compare the effect of Fractional CO2 laser or Q switched Nd:YAG laser of surface treatment on the shear bond strength of zirconia-porcelain interface. Methods: Fractional CO2 laser at 30 W, 2 ms, time interval 1 ms, distance between spots 0.3 mm, and number of scans is (4) or Q switched Nd:YAG laser at 30 J/mm2 and 10 Hz were used to assess the shear bond strength of zirconia to porcelain. Pre-sintered zirconia specimens were divided into three groups (n = 10) according to the surface treatment technique used: (a) untreated (Control) group; (b) CO2 group; (c) Nd:YAG group. All samples were then sintered and veneered with porcelain according to the manufacturer's instructions. Surface morphology was examined using a light microscope, the surface roughness test was done by the atomic force microscope (AFM), and the shear bond strength (SBS) test was done by a universal testing machine. After debonding following shear bond test, zirconia surfaces were examined under a light microscope to determine their fracture mode. Results: The Results of this study showed that the lowest SBS was recorded in the control group, and the highest SBS recorded in the Fractional CO2 group, followed by the Q switched Nd:YAG laser group, as well as an increase in surface roughness and change in the morphology and mode of failure in the experimental groups. Conclusion: This study shows that Fractional CO2 laser and Q switched Nd:YAG laser treatments significantly increase the bond strength than untreated zirconia.
Collapse
Affiliation(s)
| | - Basima M A Hussein
- Institute of Laser for Postgraduate Studies, University of Baghdad, Baghdad, Iraq
| | - Ali M Mahmood
- Institute of Laser for Postgraduate Studies, University of Baghdad, Baghdad, Iraq
| |
Collapse
|
9
|
Comparison of lithium disilicate-reinforced glass ceramic surface treatment with hydrofluoric acid, Nd:YAG, and CO2 lasers on shear bond strength of metal brackets. Clin Oral Investig 2020; 25:2659-2666. [PMID: 32918122 DOI: 10.1007/s00784-020-03576-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 09/04/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To evaluate and compare the effects of different surface conditioning methods of lithium disilicate-reinforced ceramic on shear bond strength (SBS) of metallic brackets. MATERIALS AND METHODS Thirty-six lithium disilicate ceramic blocks mounted in acrylic resin blocks were assigned to 3 groups (n = 12): 9.6% hydrofluoric acid (HF); neodymium-doped yttrium aluminium garnet (Nd:YAG) laser; and carbon dioxide (CO2) laser. The glass ceramic surfaces were primed with a silane, and the brackets were bonded using a light-cured composite resin. SBS test was carried out in a universal testing machine at 0.5 mm/min crosshead speed until the brackets were debonded. The remaining adhesive was evaluated under a stereomicroscope in terms of the adhesive remnant index (ARI). The surface hardness was determined with a 100-gr force using a microhardness tester. Glass ceramic surface changes were evaluated using the scanning electron microscope. One-way ANOVA and post hoc Tamhane tests were used to compare microhardness values, and Kruskal-Wallis and Mann-Whitney U tests were used to analyze SBS values and ARI. RESULTS The median and interquartile range of SBS values in 3 groups were 6.48 (1.56-15.18), 1.26 (0.83-1.67), and 0.99 MPa (0.70-2.10), respectively. Microhardness analysis revealed significant differences between the CO2 laser and intact porcelain groups (P = 0.003), without significant differences between the other groups. Group 1 exhibited the highest ARI. CONCLUSION Neither CO2 nor Nd:YAG lasers resulted in adequate surface changes for bonding of brackets on ceramics compared with the samples conditioned with HF. CO2 laser decreased the microhardness of ceramics. CLINICAL RELEVANCE Surface conditioning with HF resulted in clinically acceptable SBS values.
Collapse
|
10
|
Alzainal AH, Majud AS, Al-Ani AM, Mageet AO. Orthodontic Bonding: Review of the Literature. Int J Dent 2020; 2020:8874909. [PMID: 32733564 PMCID: PMC7376407 DOI: 10.1155/2020/8874909] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 06/30/2020] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Patients seeking orthodontic treatment are increasing, and clinicians often have to place brackets on various surfaces aside from enamel. It is crucial to know what materials or instruments are required to bond brackets to each surface. OBJECTIVE This study aims to serve as a clinical guideline for the safest and most effective approaches taken to condition various surfaces for bonding to orthodontic brackets and provide background knowledge on the subject. MATERIALS AND METHODS PubMed and EBSCO databases were searched, along with the use of Google Scholar search engine, to obtain relevant articles published in English in peer-reviewed journals, from 1955 to 2020. Keywords used were Shear bond strength; Orthodontic bracket; Base design; Etching; Sandblasting; Laser; Conditioning; Enamel; Ceramic; Porcelain; Gold; Amalgam; Composite. CONCLUSION Even though orthophosphoric acid is the most widely used enamel conditioning agent, laser etching should be considered to avoid enamel decalcification. Hydrofluoric acid is the current standard for ceramic conditioning; however, its use intraorally should be minimized due to its toxicity. Orthophosphoric acid, CoJet-Sand air abrasion, and laser etching are viable alternatives for conditioning ceramic. Monobond Etch & Prime is toxic and should not be used intraorally. Composite can be conditioned by bur roughening, and the use of ceramic brackets is recommended. Amalgam and gold surfaces can be conditioned adequately by air abrasion. Despite the claims of many authors, the maximum shear forces that orthodontic brackets are subjected to are not 6-8 mega pascal (MPa). Further investigation is required in that regard. More in vivo studies need to be performed to confirm the in vitro results.
Collapse
|
11
|
Photosensitization of lithium di-silicate ceramic by Er, Cr: YSGG and fractional carbon dioxide laser bonded to orthodontic bracket. Photodiagnosis Photodyn Ther 2019; 28:273-276. [DOI: 10.1016/j.pdpdt.2019.08.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Revised: 08/05/2019] [Accepted: 08/12/2019] [Indexed: 11/20/2022]
|
12
|
Ahrari F, Boruziniat A, Mohammadipour HS, Alirezaei M. The Effect of Fractional CO2 Laser Irradiation on Shear Bond Strength of Resin Cement to Feldspathic Porcelain. J Lasers Med Sci 2018; 9:101-106. [PMID: 30026894 DOI: 10.15171/jlms.2018.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: This study investigated the effect of fractional CO2 laser on shear bond strength (SBS) of resin cement to feldspathic porcelain. Methods: Sixty blocks of unglazed feldspathic porcelain were randomly divided into 5 groups of 12 by treatment. Group 1 and 2 underwent etching with 9.6% hydrofluoric acid (HF) and air abrasion with alumina particles, respectively. In groups 3 and 4, a fractional CO2 laser was applied for 10 seconds using 20 W/10 mJ (group 3) or 15 W/20 mJ (group 4). The specimens in group 5 were first treated by fractional CO2 laser (15 W/20 mJ) and then etched by HF acid. After silane application, a resin cement (Clearfil SA) was poured into plastic molds over the porcelain surface and light cured. SBS was assessed by a universal testing machine and the type of bond failure was determined. Results: Analysis of variance (ANOVA) indicated a significant difference in SBS among the study groups (P<0.001). Pairwise comparison demonstrated that the application of fractional CO2 laser followed by HF acid yielded SBS that was significantly greater than that of the other groups (P<0.05). The SBS of both laser groups (groups 3 and 4) were comparable to each other and significantly lower than the other groups (P<0.05). No significant difference was found in the distribution of failure modes among the groups (P=0.522) Conclusion: The application of fractional CO2 laser followed by HF acid treatment can improve SBS of resin cement to feldspathic porcelain and could be recommended when demanding extra retention.
Collapse
Affiliation(s)
- Farzaneh Ahrari
- Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Alireza Boruziniat
- Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | | |
Collapse
|