1
|
Kowalski J, Rylska D, Januszewicz B, Konieczny B, Cichomski M, Matinlinna JP, Radwanski M, Sokolowski J, Lukomska-Szymanska M. Corrosion Resistance of Titanium Dental Implant Abutments: Comparative Analysis and Surface Characterization. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6624. [PMID: 37895605 PMCID: PMC10608008 DOI: 10.3390/ma16206624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 10/02/2023] [Accepted: 10/08/2023] [Indexed: 10/29/2023]
Abstract
Metals subjected to the oral environment are prone to corrosion over time and this can be harmful. Metallic restoration components such as dental subgingival implant abutments are exposed to pH changes and different ions while in contact with saliva. The aim of the study was to evaluate the corrosion resistance of titanium dental implant abutments and to compare and contrast the surface characteristics of these alloys before and after corrosion. The corrosion examination (Ecorr, jcorr, OCP, polarization curve) of two implant abutments (TiDesign EV, Astra Tech, Dentsply, York, PA, USA; Individual Titanium Abutment, Apollo Implants Components, Pabianice, Poland) was performed in 0.9% NaCl and 5% HCl. Moreover, specimens were investigated using SEM-EDS before and after the corrosion test. The value of jcorr in NaCl was higher for Astra (34.2 × 10-8 ± 2.5 × 10-8 A/cm2) than for Apollo (8.8 × 10-8 ± 2.5 × 10-8 A/cm2). Whereas, in HCl, the opposite relationship was observed (Astra 2.9 × 10-4 ± 0.8 × 10-4 A/cm2 and Apollo 62.7 × 10-4 ± 9.3 × 10-4 A/cm2). An average reactive anodic current density in NaCl for Astra amounted up to ~0.2 × 10-5-1.5 × 10-5 A/cm2, while for Apollo-up to ~3.3-9.7 × 10-7 A/cm2. The composition of both alloys after corrosion in NaCl demonstrated some changes: a decrease in the Ti, and Al and an increase in oxygen content. Hence, both alloys after corrosion in HCl demonstrated some minor changes in the elemental composition. Based on the results it can be concluded that: 1. Astra and Apollo abutments revealed good corrosion resistance and a passivation layer on the surface. 2. Apollo abutments exhibited better corrosion resistance in a neutral environment, suggesting that Astra abutments were found to be more resistant to corrosion in an acidic medium.
Collapse
Affiliation(s)
- Jakub Kowalski
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
| | - Dorota Rylska
- Institute of Materials Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego St., 90-924 Lodz, Poland; (D.R.); (B.J.)
| | - Bartłomiej Januszewicz
- Institute of Materials Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego St., 90-924 Lodz, Poland; (D.R.); (B.J.)
| | - Bartlomiej Konieczny
- University Laboratory of Materials Research, Medical University of Lodz, 251 Pomorska St., 92-213 Lodz, Poland;
| | - Michal Cichomski
- Department of Material Technology and Chemistry, Faculty of Chemistry, University of Lodz, 163 Pomorska St., 90-236 Lodz, Poland;
| | - Jukka P. Matinlinna
- Biomaterials Science, Division of Dentistry, The University of Manchester, Manchester M13 9PL, UK;
| | - Mateusz Radwanski
- Department of Endodontics, Medical University of Lodz, 92-213 Lodz, Poland;
| | - Jerzy Sokolowski
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
| | | |
Collapse
|
2
|
Navarro P, Olmo A, Giner M, Rodríguez-Albelo M, Rodríguez Á, Torres Y. Electrical Impedance of Surface Modified Porous Titanium Implants with Femtosecond Laser. MATERIALS 2022; 15:ma15020461. [PMID: 35057181 PMCID: PMC8779557 DOI: 10.3390/ma15020461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 12/31/2021] [Accepted: 01/04/2022] [Indexed: 01/25/2023]
Abstract
The chemical composition and surface topography of titanium implants are essential to improve implant osseointegration. The present work studies a non-invasive alternative of electrical impedance spectroscopy for the characterization of the macroporosity inherent to the manufacturing process and the effect of the surface treatment with femtosecond laser of titanium discs. Osteoblasts cell culture growths on the titanium surfaces of the laser-treated discs were also studied with this method. The measurements obtained showed that the femtosecond laser treatment of the samples and cell culture produced a significant increase (around 50%) in the absolute value of the electrical impedance module, which could be characterized in a wide range of frequencies (being more relevant at 500 MHz). Results have revealed the potential of this measurement technique, in terms of advantages, in comparison to tiresome and expensive techniques, allowing semi-quantitatively relating impedance measurements to porosity content, as well as detecting the effect of surface modification, generated by laser treatment and cell culture.
Collapse
Affiliation(s)
- Paula Navarro
- Departamento de Tecnología Electrónica, Escuela Técnica Superior de Ingeniería Informática, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla, Spain;
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior, Calle Virgen de África 7, 41011 Seville, Spain; (M.R.-A.); (Y.T.)
| | - Alberto Olmo
- Departamento de Tecnología Electrónica, Escuela Técnica Superior de Ingeniería Informática, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla, Spain;
- Instituto de Microelectrónica de Sevilla, IMSE-CNM (CSIC, Universidad de Sevilla), Av. Américo Vespucio s/n, 41092 Sevilla, Spain
- Correspondence: ; Tel.: +34-954556835
| | - Mercè Giner
- Departamento de Citología e Histología Normal y Patológica, Universidad de Sevilla, Av. Doctor Fedriani s/n, 41009 Sevilla, Spain;
| | - Marleny Rodríguez-Albelo
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior, Calle Virgen de África 7, 41011 Seville, Spain; (M.R.-A.); (Y.T.)
| | - Ángel Rodríguez
- Escuela Politécnica Superior, Universidad da Coruña, Calle Mendizábal s/n, 15403 Ferrol, Spain;
| | - Yadir Torres
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior, Calle Virgen de África 7, 41011 Seville, Spain; (M.R.-A.); (Y.T.)
| |
Collapse
|