1
|
Namima D, Fujisawa T, Takasaki Y, Tomishima K, Ishii S, Kobara H, Isayama H. A case of successful endoscopic ultrasound/endosonography-guided pancreaticogastrostomy using a novel plastic stent. Endoscopy 2024; 56:E905-E906. [PMID: 39454652 PMCID: PMC11511614 DOI: 10.1055/a-2435-8199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2024]
Affiliation(s)
- Daisuke Namima
- Department of Gastroenterology, Juntendo University, Graduate School of Medicine, Tokyo, Japan
| | - Toshio Fujisawa
- Department of Gastroenterology, Juntendo University, Graduate School of Medicine, Tokyo, Japan
| | - Yusuke Takasaki
- Department of Gastroenterology, Juntendo University, Graduate School of Medicine, Tokyo, Japan
| | - Ko Tomishima
- Department of Gastroenterology, Juntendo University, Graduate School of Medicine, Tokyo, Japan
| | - Shigeto Ishii
- Department of Gastroenterology, Juntendo University, Graduate School of Medicine, Tokyo, Japan
| | - Hideki Kobara
- Department of Gastroenterology and Neurology, Kagawa University, Kagawa, Japan
| | - Hiroyuki Isayama
- Department of Gastroenterology, Juntendo University, Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
2
|
Miutescu B, Dhir V. Training and quality indicators in interventional endoscopic ultrasound. Dig Endosc 2024. [PMID: 39021062 DOI: 10.1111/den.14881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 06/18/2024] [Indexed: 07/20/2024]
Abstract
Endoscopic ultrasound (EUS) has transformed the landscape of minimally invasive gastrointestinal procedures, necessitating specialized training for proficiency in interventional EUS (iEUS). This study evaluates the effectiveness of iEUS training, focusing on learning curves, success rates, and the associated risks in various procedures, aiming to recommend practices for standardizing training and ensuring competency. Key metrics such as procedure type, learning curve for proficiency, success rates, and risk of adverse events were analyzed to establish benchmarks for training programs. Proficiency in pancreatic fluid collection drainage was achieved after 20-30 procedures, with a 100% success rate and a complication rate ranging from 1.5 to 80%. Gallbladder drainage required 19 cases to reach an 86% success rate, with adverse events reported in 19% of cases. Choledocoduodenostomy mastery was observed after approximately 100 cases, with postintervention pancreatitis affecting 5.3-6.6% of all cases. Hepaticogastrostomy showed a 93% success rate after 33 cases, with a 24.8% adverse event rate. Hepaticoenterostomy reached 100% success beyond the 40th patient, with a 20% rate of postsurgical strictures. Pancreatic duct drainage achieved 89% technical and 87% clinical success after 27 cases, with 12-15% adverse events. Gastro-enteric anastomosis required 25 cases for proficiency and approximately 40 cases for mastery, with 5.5% immediate and 1% late adverse events. iEUS training outcomes vary significantly across different procedures, highlighting the importance of structured, procedure-specific training programs to achieve proficiency. These findings provide a foundation for developing universal competency benchmarks in iEUS, facilitating consistent and effective training worldwide.
Collapse
Affiliation(s)
- Bogdan Miutescu
- Department of Gastroenterology and Hepatology, "Victor Babeş" University of Medicine and Pharmacy, Timisoara, Romania
| | - Vinay Dhir
- Institute of Digestive and Liver Care, SL Raheja Hospital, Mumbai, India
| |
Collapse
|
3
|
Yane K, Imagawa T, Yoshida M. Spontaneous migration of a dedicated plastic stent after endoscopic ultrasound-guided hepaticogastrostomy in a patient with surgically altered anatomy: a case report. J Rural Med 2024; 19:196-198. [PMID: 38975036 PMCID: PMC11222626 DOI: 10.2185/jrm.2023-050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 04/08/2024] [Indexed: 07/09/2024] Open
Abstract
Objective: We report a case of spontaneous migration of a dedicated plastic stent after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) in a patient with surgically altered anatomy. Patient: The patient was a male in his 70s. He underwent EUS-HGS with the successful insertion of a dedicated plastic stent and had no obvious postprocedural complications. However, nine days after the procedure, the patient visited our hospital because of abdominal pain, fever, and stent excretion. We performed EUS-HGS with antegrade stenting, after which the patient had no further complications. Conclusion: Stent migration is considered a complication requiring caution when performing EUS-HGS in patients with surgically altered anatomy.
Collapse
Affiliation(s)
- Kei Yane
- Department of Gastroenterology, Tonan Hospital, Japan
| | | | | |
Collapse
|
4
|
Alsakarneh S, Madi MY, Dahiya DS, Jaber F, Kilani Y, Ahmed M, Beran A, Abdallah M, Al Ta’ani O, Mittal A, Numan L, Goyal H, Bilal M, Kiwan W. Is Endoscopic Ultrasound-Guided Hepaticogastrostomy Safe and Effective after Failed Endoscopic Retrograde Cholangiopancreatography?-A Systematic Review and Meta-Analysis. J Clin Med 2024; 13:3883. [PMID: 38999449 PMCID: PMC11242375 DOI: 10.3390/jcm13133883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 06/22/2024] [Accepted: 06/26/2024] [Indexed: 07/14/2024] Open
Abstract
Background/Objectives: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) has emerged as an alternative option for biliary drainage in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). Limited data exist on the safety and efficacy of EUS-HGS. In this comprehensive meta-analysis, we aim to study the safety and efficacy of EUS-HGS in cases of failed conventional ERCP. Methods: Embase, PubMed, and Web of Science databases were searched to include all studies that evaluated the efficacy and safety of EUS-HGS. Using the random effect model, the pooled weight-adjusted event rate estimate for clinical outcomes in each group were calculated with 95% confidence intervals (CIs). The primary outcomes were technical and clinical success rates. Secondary outcomes included overall adverse events (AEs), rates of recurrent biliary obstruction (RBO), and rates or re-intervention. Results: Our analysis included 70 studies, with a total of 3527 patients. The pooled technical and clinical success rates for EUS-HGS were 98.1% ([95% CI, 97.5-98.7]; I2 = 40%) and 98.1% ([95% CI, 97.5-98.7]; I2 = 40%), respectively. The pooled incidence rate of AEs with EUS-HGS was 14.9% (95% CI, 12.7-17.1), with bile leakage being the most common (2.4% [95% CI, 1.7-3.2]). The pooled incidence of RBO was 15.8% [95% CI, 12.2-19.4], with a high success rate for re-intervention (97.5% [95% CI, 94.7-100]). Conclusions: Our analysis showed high technical and clinical success rates of EUS-HGS, making it a feasible and effective alternative to ERCP. The ongoing development of dedicated devices and techniques is expected to make EUS-HGS more accessible and safer for patients in need of biliary drainage.
Collapse
Affiliation(s)
- Saqr Alsakarneh
- Department of Internal Medicine, University of Missouri-Kansas City, Kansas City, MO 64108, USA; (S.A.)
| | - Mahmoud Y. Madi
- Department of Gastroenterology and Hepatology, Saint Louis University, Saint Louis, MO 63103, USA
| | - Dushyant Singh Dahiya
- Division of Gastroenterology, Hepatology & Motility, The University of Kansas School of Medicine, Kansas City, KS 66103, USA
| | - Fouad Jaber
- Department of Internal Medicine, University of Missouri-Kansas City, Kansas City, MO 64108, USA; (S.A.)
| | - Yassine Kilani
- Department of Internal Medicine, Weill Cornell University, New York, NY 10065, USA
| | - Mohamed Ahmed
- Department of Gastroenterology and Hepatology, University of Missouri-Kansas City, Kansas City, MO 64108, USA
| | - Azizullah Beran
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | - Mohamed Abdallah
- Department of Gastroenterology and Hepatology, Cleveland Clinic Foundation, Cleveland, OH 44195, USA
| | - Omar Al Ta’ani
- Department of Internal Medicine, Allegheny General Hospital, Allegheny, PA 15212, USA
| | - Anika Mittal
- Department of Internal Medicine, University of Missouri-Kansas City, Kansas City, MO 64108, USA; (S.A.)
| | - Laith Numan
- Department of Gastroenterology and Hepatology, Saint Louis University, Saint Louis, MO 63103, USA
| | - Hemant Goyal
- Division of Gastroenterology and Hepatology, Borland Groover, Jacksonville, FL 32207, USA
| | - Mohammad Bilal
- Division of Gastroenterology and Hepatology, University of Minnesota, Minneapolis, MN 55455, USA
| | - Wissam Kiwan
- Department of Gastroenterology and Hepatology, Saint Louis University, Saint Louis, MO 63103, USA
| |
Collapse
|
5
|
Canakis A, Tyberg A. Endoscopic Ultrasound-Guided Biliary Drainage (EUS-BD). Gastrointest Endosc Clin N Am 2024; 34:487-500. [PMID: 38796294 DOI: 10.1016/j.giec.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2024]
Abstract
Endoscopic ultrasound (EUS)-guided biliary drainage (BD) is a minimally invasive procedure that allows for biliary access when conventional endoscopic retrograde cholangiopancreatography (ERCP) is unsuccessful. The technique can be divided based on biliary access route: intrahepatic or extrahepatic, as well as on stenting approach: rendezvous approach (EUS-RV), antegrade placement, or transluminal (intra or extra hepatic) placement. There is no clear consensus on which approach is superior. Compared to percutaneous transhepatic biliary drainage, EUS-BD offers lower rates of adverse events without the need for an external drain. Compared to conventional ERCP, EUS-BD shows comparable, and in some cases superior, outcomes related to technical success, clinical success, and adverse events.
Collapse
Affiliation(s)
- Andrew Canakis
- Division of Gastroenterology & Hepatology, University of Maryland School of Medicine, 22 South Greene Street, Baltimore, MD 21201, USA
| | - Amy Tyberg
- Hackensack University Medical Center, Hackensack, NJ, USA.
| |
Collapse
|
6
|
Yane K, Yoshida M, Imagawa T, Morita K, Ihara H, Hanada K, Hirokawa S, Tomita Y, Minagawa T, Okagawa Y, Sumiyoshi T, Hirayama M, Kondo H. Usefulness of endoscopic ultrasound-guided transhepatic biliary drainage with a 22-gauge fine-needle aspiration needle and 0.018-inch guidewire in the procedure's induction phase. DEN OPEN 2024; 4:e297. [PMID: 37822965 PMCID: PMC10564090 DOI: 10.1002/deo2.297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/04/2023] [Accepted: 09/18/2023] [Indexed: 10/13/2023]
Abstract
Endoscopic ultrasound (EUS)-guided transhepatic biliary drainage is usually performed with a 19-gauge fine-needle aspiration (FNA) needle and a 0.025-inch guidewire. The combination of a 22-gauge FNA needle and a 0.018-inch guidewire is reported to be effective as a rescue option when the bile duct diameter is small or technically challenging. Experts in EUS-guided transhepatic biliary drainage have reported that bile duct puncture with a 19-gauge FNA needle is possible in most cases, but is not easy to reproduce by endoscopists with less experience in EUS-guided transhepatic biliary drainage. We investigated the usefulness of EUS-guided transhepatic biliary drainage using a 22-gauge FNA needle and a 0.018-inch guidewire during the procedure's induction phase. Consecutive patients who underwent EUS-guided transhepatic biliary drainage at our institution from March 2021 to May 2023 were evaluated, and 37 were included. Biliary drainage was performed for malignant bile duct stricture in 36 patients and choledocholithiasis in one patient. The median target bile duct diameter was 4.5 mm (2.5-9.4). Biliary access, fistula dilation, and stent placement were successful in the 37 patients (100%). The median procedure time was 35 min (16-125). Adverse events occurred in four (10.8%) patients. EUS-guided transhepatic biliary drainage using a 22-gauge FNA needle and a 0.018-inch guidewire is a useful and promising option for endoscopists with limited experience in EUS-guided transhepatic biliary drainage in the procedure's induction phase.
Collapse
Affiliation(s)
- Kei Yane
- Department of GastroenterologyTonan HospitalSapporoJapan
| | | | | | - Kotaro Morita
- Department of GastroenterologyTonan HospitalSapporoJapan
| | - Hideyuki Ihara
- Department of GastroenterologyTonan HospitalSapporoJapan
| | - Kota Hanada
- Department of GastroenterologyTonan HospitalSapporoJapan
| | - Sota Hirokawa
- Department of GastroenterologyTonan HospitalSapporoJapan
| | - Yusuke Tomita
- Department of GastroenterologyTonan HospitalSapporoJapan
| | | | - Yutaka Okagawa
- Department of GastroenterologyTonan HospitalSapporoJapan
| | | | | | - Hitoshi Kondo
- Department of GastroenterologyTonan HospitalSapporoJapan
| |
Collapse
|
7
|
Caillol F, Godat S, Solovyev A, Harouchi A, Oumrani S, Marx M, Hoibian S, Dahel Y, Ratone JP, Giovannini M. EUS-BD for calibration of benign stenosis of the bile duct in patients with altered anatomy or inaccessible papilla. Endosc Int Open 2024; 12:E377-E384. [PMID: 38464978 PMCID: PMC10919993 DOI: 10.1055/a-2261-2968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Accepted: 02/01/2024] [Indexed: 03/12/2024] Open
Abstract
Background and study aims In cases of inaccessible papilla, EUS-guided biliary drainage (EUS-BD) has been described as an alternative to calibrate benign biliary stenosis. However, few studies are available. Patients and methods This tw-center, retrospective study was designed to evaluate technical success and clinical success at 1 year. All patients who underswent EUS-BD without the rendezvous technique used for calibration of benign biliary stenosis were included from 2016 to 2022. Patients underwent EUS-hepaticogastrostomy (EUS-HGS) during the first session. Then, HGS was used to access the bile duct, allowing calibration of the stenosis: Dilation of the biliary stenosis and placement of double pigtail stents through the stenosis for 1 year. Results Thirty-six patients were included. Technical success was 89% (32/36), with four failures to cross the stenosis but EUS-HGS was performed in 100% of the cases. Nine patients were excluded during calibration because of oncological relapse in six and complex stenosis in three. Three patients had not yet reached 1 year of follow-up. Twenty patients had a calibration for at least 1 year. Clinical success after stent placement was considered in all cases after 1 year of follow-up. Thirteen patients underwent stent removal and no relapse occurred after 435 days of follow-up (SD=568). Global morbidity was 41.7% (15/36) with only one serious complication (needing intensive care), including seven cases of cholangitis due to intrabiliary duct obstruction and five stent migrations. No deaths were reported. Conclusions EUS-BD for calibration in case of benign biliary stenosis is an option. Dedicated materials are needed to decrease morbidity.
Collapse
Affiliation(s)
- Fabrice Caillol
- Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France
| | - Sébastien Godat
- gastroentérologie, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | - Alexey Solovyev
- Statistics Unit, Paoli-Calmettes Institute, Marseille, France
| | - Amina Harouchi
- Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France
| | - Sarra Oumrani
- Gastroenterology and Hepatology, CHUV, Lausanne, Switzerland
| | - Mariola Marx
- Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France
| | - Solene Hoibian
- Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France
| | - Yanis Dahel
- Endoscopy Unit, Paoli-Calmettes Institute, Marseille, France
| | | | | |
Collapse
|
8
|
Kanadani T, Ogura T, Ueno S, Okuda A, Nishioka N, Nakamura J, Yamada M, Uba Y, Tomita M, Hattori N, Sakamoto J, Nishikawa H. Transluminal antegrade drill dilation technique for hepaticojejunostomy stricture with cholangioscopic evaluation (with video). Endosc Int Open 2024; 12:E181-E187. [PMID: 38348332 PMCID: PMC10861321 DOI: 10.1055/a-2218-1538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 09/14/2023] [Indexed: 02/15/2024] Open
Abstract
Background and study aims Balloon dilation and plastic stent deployment have been performed as hepaticojejunostomy stricture (HJS) treatment techniques under endoscopic ultrasound guidance (EUS). Although these techniques have shown favorable clinical results, the treatment period can be long because stent deployment is required. In addition, HJS may recur even after treatment because the scar tissue itself remains. To overcome these challenges, we developed an EUS-guided antegrade drill dilation technique for treating HJS. The aim of this study was to evaluate the technical feasibility and safety of this technique in terms of the pre- and post-cholangioscopic findings. Patients and methods This retrospective study included consecutive patients whose conditions were complicated with symptomatic HJS between November 2022 and February 2023. Transluminal antegrade drill dilation (TAD) using a novel drill dilator was attempted within 14 days after EUS-guided hepaticogastrostomy (HGS). HJS was diagnosed with cholangioscopy before TAD, and resolution was evaluated after TAD using cholangioscopy. Results TAD was attempted at approximately 11 days after EUS-HGS. The cholangioscope was inserted successfully in all patients after this procedure. Cholangioscopy revealed stricture without evidence of malignancy in 19 patients. In the remaining three patients, stricture was not observed and these patients underwent stent exchange rather than TAD. Among the 19 patients, passage of the guidewire across the HJS into the intestine was unsuccessful in four patients, and the technical success rate for this procedure was 78.9%. TAD was successful in all 15 patients in whom passage of the guidewire was achieved. Conclusions In conclusion, TAD appears to be technically feasible and safe.
Collapse
Affiliation(s)
- Takafumi Kanadani
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Takeshi Ogura
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Saori Ueno
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Atsushi Okuda
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Nobu Nishioka
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Junichi Nakamura
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Masanori Yamada
- Endoscopic Center, Osaka Medical and Pharmaceutical University, Takatsuki, Japan
| | - Yuki Uba
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Mitsuki Tomita
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Nobuhiro Hattori
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Jun Sakamoto
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| | - Hiroki Nishikawa
- 2nd Department of Internal Medicine, Osaka Medical College, Takatsuki-shi, Japan
| |
Collapse
|
9
|
Bessho K, Ogura T, Ueno S, Okuda A, Nishioka N, Sakamoto J, Yamamoto Y, Uba Y, Tomita M, Hattori N, Nakamura J, Nishikawa H. Moving scope technique improves technical success rate of device insertion during EUS-guided hepaticogastrostomy (with video). Therap Adv Gastroenterol 2023; 16:17562848231207004. [PMID: 37900005 PMCID: PMC10605674 DOI: 10.1177/17562848231207004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 09/21/2023] [Indexed: 10/31/2023] Open
Abstract
Background Technical tips for device insertion during endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) have not been reported. To improve the technical success rate of device insertion without unnecessary tract dilation, the pushing force should be transmitted directly from the channel of the echoendoscope to the intrahepatic bile duct. Objectives We developed a novel technique, termed the 'moving scope technique', the feasibility of which during EUS-HGS is described. Design Retrospective study. Methods The primary outcome of this study was the technical success rate of dilation device insertion without electrocautery dilation after the moving scope technique. The initial technical success rate of dilation device insertion was defined as successful insertion into the biliary tract. If dilation device insertion failed, the moving scope technique was attempted. Results A total of 143 patients were enrolled in this study. The initial technical success rate for device insertion was 80.4% (115/143). The moving scope technique was therefore attempted in 28 patients. The mean angle between the intrahepatic bile duct and the guidewire was improved to 141.0° and resulted in a technical success rate of 100% (28/28). The area under the ROC curve (AUC) was 0.88, and 120° predicted successful dilation device insertion with sensitivity of 88.0% and specificity of 78.8%. Bile peritonitis (n = 8) and cholangitis (n = 2) were observed as adverse events, but were not severe. Conclusion In conclusion, the moving scope technique may be helpful during EUS-HGS to achieve successful insertion of the dilation device into the biliary tract. These results should be evaluated in a prospective randomized controlled trial.
Collapse
Affiliation(s)
- Kimi Bessho
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Takeshi Ogura
- Endoscopy Center, Osaka Medical and Pharmaceutical University, Osaka, Japan
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, 2-7 Daigakuchou, Takatsukishi, Osaka 569-8686, Japan
| | - Saori Ueno
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Atsushi Okuda
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Nobu Nishioka
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Jun Sakamoto
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Yoshitaro Yamamoto
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Yuki Uba
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Mitsuki Tomita
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Nobuhiro Hattori
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Junichi Nakamura
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| | - Hiroki Nishikawa
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
| |
Collapse
|
10
|
Ramchandani M, Pal P, Costamagna G. Management of Benign Biliary Stricture in Chronic Pancreatitis. Gastrointest Endosc Clin N Am 2023; 33:831-844. [PMID: 37709414 DOI: 10.1016/j.giec.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
Endoscopic therapy is the first line of management for chronic pancreatitis (CP)-related benign biliary strictures. Multiple plastic stents (MPS) exchanged at regular intervals and temporary placement of fully covered self-expanding metal stents (FCSEMS) are preferred modalities of endotherapy. FCSEMS placement is non-inferior to MPS and requires fewer sessions of endoscopic retrograde cholangiopancreatography than MPS placement. The presence of head calcifications, severe CP, and length of stricture are predictors of failure or recurrence after endotherapy. Failure of endotherapy should be considered after 1 year when surgery should be considered.
Collapse
Affiliation(s)
- Mohan Ramchandani
- Department of Medical Gastroenterology, Asian Institute of Gastroenterology, 6-3-661, Somajiguda, Hyderabad, Telangana, India; Interventional Endoscopy, AIG Hospitals, Plot No 2/3/4/5 Survey, 1, Mindspace Road, Gachibowli, Hyderabad, Telangana 500032, India.
| | - Partha Pal
- Department of Medical Gastroenterology, Asian Institute of Gastroenterology, 6-3-661, Somajiguda, Hyderabad, Telangana, India
| | - Guido Costamagna
- Department of Translational Medicine and Surgery, Catholic University, Rome
| |
Collapse
|
11
|
Miwa H, Sugimori K, Matsuoka Y, Endo K, Oishi R, Nishimura M, Tozuka Y, Kaneko T, Numata K, Maeda S. Loop technique for guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy. JGH Open 2023; 7:358-364. [PMID: 37265928 PMCID: PMC10230106 DOI: 10.1002/jgh3.12903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 06/03/2023]
Abstract
Background and Aim Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is widely used in the management of biliary obstructions; however, literature on guidewire manipulation is lacking. This study aimed to assess the utility and optimal conditions of the loop technique for guidewire manipulation during EUS-HGS. Methods Consecutive patients who underwent EUS-HGS between April 2015 and January 2022 were included in this study. Patient characteristics and procedural details were retrospectively analyzed. Guidewire manipulations were classified as conventional technique or loop technique, based on the shape of the guidewire tip. Results A total of 52 patients (Median age: 73 years, 38 male and 14 female) underwent EUS-HGS. The median guidewire insertion time was 49 s and the median overall procedure time was 20.5 min. The initial guidewire direction was toward the peripheral side in 23 patients (44%). Technical success rate of the EUS-HGS was 100%. Twenty patients (38%) underwent the procedure using the loop technique and 32 (62%) with the conventional technique. In the logistic regression analysis, an angle between the bile duct and needle of >70° was independently associated with use of the loop technique (OR 9.84; 95% CI: 2.24-43.13; P <0.01). Conclusion This study revealed the utility of the loop technique in EUS-HGS. This technique is recommended if the bile duct is punctured at an angle >70°.
Collapse
Affiliation(s)
- Haruo Miwa
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Kazuya Sugimori
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Yuto Matsuoka
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Kazuki Endo
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Ritsuko Oishi
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Masaki Nishimura
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Yuichiro Tozuka
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Takashi Kaneko
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Kazushi Numata
- Gastroenterological CenterYokohama City University Medical CenterYokohamaJapan
| | - Shin Maeda
- Division of GastroenterologyYokohama City University Graduate School of MedicineYokohamaJapan
| |
Collapse
|
12
|
Kitagawa K, Mitoro A, Minami R, Nagamatsu S, Ozutsumi T, Fujinaga Y, Nishimura N, Sawada Y, Namisaki T, Akahane T, Kaji K, Tomooka F, Asada S, Kaneko M, Yoshiji H. Efficacy of a dedicated plastic stent in endoscopic ultrasound-guided hepaticogastrostomy during the learning curve: cumulative multi-center experience. Scand J Gastroenterol 2023; 58:296-303. [PMID: 36073949 DOI: 10.1080/00365521.2022.2118557] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND OBJECTIVES Currently, there are no reports on the learning curve of endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) using dedicated plastic stents. Therefore, we evaluated the outcomes of EUS-HGS using dedicated plastic stents at tertiary referral centers during the initial development phase of EUS-HGS. MATERIALS AND METHODS Endoscopic retrograde cholangiopancreatography (ERCP) was strictly prioritized over EUS-HGS. Twenty-three consecutive patients treated using EUS-HGS with a 7-Fr dedicated plastic stent over 4 years beginning in 2018 were analyzed retrospectively. RESULTS The most common primary disease was pancreatic cancer, and the most common reason for difficulty in ERCP was duodenal obstruction, followed by surgically altered anatomy. The overall technical success rate of EUS-HGS was 95.7% (22/23). One failed case was converted to EUS-guided choledochoduodenostomy. The clinical success rate was 90.9% (20/22). Adverse events (AEs) related to the procedure were observed in four (17.4%) patients, including mild biliary peritonitis in three (13.0%) and mild cholangitis in one (4.3%) patient; all patients received conservative therapy. No serious AEs, such as stent migration, bleeding, or gastrointestinal perforation, were observed. Recurrent biliary obstruction (RBO) was observed in eight (34.8%) patients. Of these, HGS stent replacement was performed in four patients, and other treatments were performed in the remaining four patients. Another four (17.4%) patients did not develop RBO but underwent periodic HGS stent replacement. CONCLUSIONS EUS-HGS using a dedicated plastic stent was performed safely even in its initial phase of introduction. The approach using this stent can be useful in case of ERCP failure for biliary decompression because of the high feasibility and low risk of serious adverse events.
Collapse
Affiliation(s)
- Koh Kitagawa
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Akira Mitoro
- Division of Endoscopy, Nara Medical University, Nara, Japan
| | - Ryuki Minami
- Department of Gastroenterology, Tenri Hospital, Nara, Japan
| | - Shinsaku Nagamatsu
- Department of Gastroenterology, Nara Prefecture General Medical Center, Nara, Japan
| | | | - Yukihisa Fujinaga
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | | | - Yasuhiko Sawada
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Tadashi Namisaki
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Takemi Akahane
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Kosuke Kaji
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Fumimasa Tomooka
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Shohei Asada
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Miki Kaneko
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Hitoshi Yoshiji
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| |
Collapse
|
13
|
Tanisaka Y, Mizuide M, Fujita A, Jinushi R, Shiomi R, Shin T, Hirata D, Terada R, Tashima T, Mashimo Y, Ryozawa S. Endoscopic ultrasound‑guided biliary drainage in patients with surgically altered anatomy: a systematic review and Meta‑analysis. Scand J Gastroenterol 2023; 58:107-115. [PMID: 35993426 DOI: 10.1080/00365521.2022.2111228] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND AIMS Endoscopic retrograde cholangiopancreatography is technically challenging to perform in patients with surgically altered anatomy (SAA). For these patients, endoscopic ultrasound-guided biliary drainage (EUS-BD) is one of the good indications. The aim of our systematic review and meta-analysis was to identify and evaluate evidence of the efficacy and safety of EUS-BD in patients with SAA. METHODS A systematic review of the PubMed was conducted through to December 2021 to identify studies performing EUS-BD in patients with SAA. The primary outcome was the pooled technical success proportion in patients with SAA. The pooled clinical success and adverse event proportions in patients with SAA were also analyzed. RESULTS The search identified 1195 possible records, with 18 studies meeting our criteria for analysis, reporting data for 409 patients with SAA who underwent EUS-BD. The pooled technical success, clinical success and adverse event proportions in patients with SAA were 97.8% (95% confidence interval [CI], 95.8-99.7%), 94.9% (95% CI, 91.8-98.1%), and 12.8% (95% CI, 7.4-18.1%), respectively. CONCLUSIONS EUS-BD is effective for patients with SAA. However, adverse events should be considered when performing EUS-BD in these patients.
Collapse
Affiliation(s)
- Yuki Tanisaka
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Masafumi Mizuide
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Akashi Fujita
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Ryuhei Jinushi
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Rie Shiomi
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Takahiro Shin
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Dai Hirata
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Rie Terada
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Tomoaki Tashima
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Yumi Mashimo
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Shomei Ryozawa
- Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
| |
Collapse
|
14
|
Mukai S, Itoi T, Tsuchiya T, Ishii K, Tonozuka R, Nagakawa Y, Kozono S, Takishita C, Osakabe H, Sofuni A. Clinical feasibility of endoscopic ultrasound-guided biliary drainage for preoperative management of malignant biliary obstruction (with videos). JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2022. [PMID: 36458423 DOI: 10.1002/jhbp.1292] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 11/18/2022] [Accepted: 11/26/2022] [Indexed: 12/04/2022]
Abstract
BACKGROUND/PURPOSE EUS-guided biliary drainage (EUS-BD) has recently been reported to be a useful salvage technique after ERCP fail. However, data on EUS-BD used for preoperative biliary drainage (PBD) are limited. The aim of this study was to verify the clinical feasibility of EUS-BD for PBD. METHODS PBD was performed for malignant biliary obstruction in 318 patients at our institution between July 2014 and April 2022. Fifteen (4.7%) of these patients underwent surgical resection after preoperative EUS-BD (HGS 13; HDS 1; AGS with HGS 1) and were retrospectively analyzed. RESULTS The stent was successfully placed in all 15 cases with a median procedure time of 15 min (technical success rate 100%). The median total bilirubin value decreased significantly from 3.7 before drainage to 0.9 after surgery (p < .001) and cholangitis was well managed (clinical success rate 100%). Surgery was performed at a median of 22 days after drainage, and there were no stent-related adverse events or recurrences of biliary obstruction. Severe surgery-related adverse events occurred in three cases, but none were associated with EUS-BD. The stent was removed during surgery in 12 cases. CONCLUSIONS EUS-BD can be a feasible and safe alternative method of PBD for malignant biliary obstruction after ERCP fail.
Collapse
Affiliation(s)
- Shuntaro Mukai
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Takao Itoi
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Takayoshi Tsuchiya
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Kentaro Ishii
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Ryosuke Tonozuka
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Yuichi Nagakawa
- Department of Gastrointestinal and Pediatric Surgery, Tokyo Medical University, Tokyo, Japan
| | - Shingo Kozono
- Department of Gastrointestinal and Pediatric Surgery, Tokyo Medical University, Tokyo, Japan
| | - Chie Takishita
- Department of Gastrointestinal and Pediatric Surgery, Tokyo Medical University, Tokyo, Japan
| | - Hiroaki Osakabe
- Department of Gastrointestinal and Pediatric Surgery, Tokyo Medical University, Tokyo, Japan
| | - Atsushi Sofuni
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| |
Collapse
|
15
|
Endoscopic Ultrasound-Guided Hepaticogastrostomy with Antegrade Stenting Without Dilation Device Application for Malignant Distal Biliary Obstruction in Pancreatic Cancer. Dig Dis Sci 2022; 68:2090-2098. [PMID: 36350476 DOI: 10.1007/s10620-022-07749-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 10/26/2022] [Indexed: 11/10/2022]
Abstract
BACKGROUND Endoscopic ultrasound-guided hepaticogastrostomy with antegrade stenting (EUS-HGAS) is a promising therapeutic option for malignant distal biliary obstruction (MDBO) in the event of transpapillary approach failure. Eliminating the fistula dilation step may further decrease the incidence of adverse events (AE) and simplify the procedure. AIMS This study focused on MDBO associated with pancreatic cancer and aimed to examine the utility of EUS-HGAS without the use of any dilation devices. METHODS This retrospective study investigated consecutive patients in whom the transpapillary approach had failed or was difficult, and who underwent EUS-HGAS without dilation device usage, using a tapered small-diameter catheter, ultrathin delivery system, and tapered dedicated plastic stent. The outcomes of this study included the technical success, clinical success, AE incidence, and recurrent biliary obstruction (RBO) associated with the procedure. RESULTS During the study period, EUS-HGAS without dilation device usage was attempted for 57 patients with MDBO due to pancreatic cancer. The technical and clinical success rates were 91.2% (52/57) each. The median procedural time was 25 min. The rates of early and late AE besides RBO were 3.5% (2/57) and 1.9% (1/52), respectively. The incidence rate of RBO was 30.8% (16/52), and the median time to RBO was 245 days. The rate of successful endoscopic reintervention for RBO via the fistula was 100% (16/16). CONCLUSIONS EUS-HGAS without the use of dilation devices showed good technical feasibility with a low AE rate. It may be a useful option for MDBO associated with pancreatic cancer when the transpapillary approach is difficult.
Collapse
|
16
|
Rana SS. Evaluating the role of endoscopic ultrasound in pancreatitis. Expert Rev Gastroenterol Hepatol 2022; 16:953-965. [PMID: 36263489 DOI: 10.1080/17474124.2022.2138856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Endoscopic ultrasound (EUS) provides high-resolution images of both pancreatic parenchyma and duct and therefore is an integral component of evaluating and treating patients with pancreatitis and its complications. The development of enhanced EUS imaging techniques and newer EUS-specific accessories has expanded the diagnostic and therapeutic role of EUS in patients with acute and chronic pancreatitis (CP). AREAS COVERED This review discusses the current diagnostic and therapeutic role of EUS in acute pancreatitis (AP), CP, and autoimmune pancreatitis (AIP). EXPERT OPINION EUS plays a vital role in patients with AP by confirming the presence of common bile duct (CBD) stones in patients with acute biliary pancreatitis and intermediate probability of CBD stones. It plays an important role in the etiological evaluation of patients with idiopathic acute and recurrent pancreatitis. EUS is also an essential modality for diagnosing and managing pancreatico-biliary as well as gastroduodenal complications associated with CP. EUS-guided FNB using newer generation core biopsy needles has made possible accurate diagnosis of AIP by providing tissue samples with preserved architecture.
Collapse
Affiliation(s)
- Surinder Singh Rana
- Department of Gastroenterology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India
| |
Collapse
|
17
|
van Wanrooij RLJ, Bronswijk M, Kunda R, Everett SM, Lakhtakia S, Rimbas M, Hucl T, Badaoui A, Law R, Arcidiacono PG, Larghi A, Giovannini M, Khashab MA, Binmoeller KF, Barthet M, Pérez-Miranda M, van Hooft JE, van der Merwe SW. Therapeutic endoscopic ultrasound: European Society of Gastrointestinal Endoscopy (ESGE) Technical Review. Endoscopy 2022; 54:310-332. [PMID: 35114696 DOI: 10.1055/a-1738-6780] [Citation(s) in RCA: 77] [Impact Index Per Article: 38.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
1: ESGE recommends a prolonged course of a prophylactic broad-spectrum antibiotic in patients with ascites who are undergoing therapeutic endoscopic ultrasound (EUS) procedures.Strong recommendation, low quality evidence. 2: ESGE recommends placement of partially or fully covered self-expandable metal stents during EUS-guided hepaticogastrostomy for biliary drainage in malignant disease.Strong recommendation, moderate quality evidence. 3: ESGE recommends EUS-guided pancreatic duct (PD) drainage should only be performed in high volume expert centers, owing to the complexity of this technique and the high risk of adverse events.Strong recommendation, low quality evidence. 4: ESGE recommends a stepwise approach to EUS-guided PD drainage in patients with favorable anatomy, starting with rendezvous-assisted endoscopic retrograde pancreatography (RV-ERP), followed by antegrade or transmural drainage only when RV-ERP fails or is not feasible.Strong recommendation, low quality evidence. 5: ESGE suggests performing transduodenal EUS-guided gallbladder drainage with a lumen-apposing metal stent (LAMS), rather than using the transgastric route, as this may reduce the risk of stent dysfunction.Weak recommendation, low quality evidence. 6: ESGE recommends using saline instillation for small-bowel distension during EUS-guided gastroenterostomy.Strong recommendation, low quality evidence. 7: ESGE recommends the use of saline instillation with a 19G needle and an electrocautery-enhanced LAMS for EUS-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) procedures.Strong recommendation, low quality evidence. 8: ESGE recommends the use of either 15- or 20-mm LAMSs for EDGE, with a preference for 20-mm LAMSs when considering a same-session ERCP.Strong recommendation, low quality evidence.
Collapse
Affiliation(s)
- Roy L J van Wanrooij
- Department of Gastroenterology and Hepatology, Amsterdam UMC, Vrije Universiteit Amsterdam, AGEM Institute, Amsterdam, The Netherlands
| | - Michiel Bronswijk
- Department of Gastroenterology and Hepatology, Imelda General Hospital, Bonheiden, Belgium.,Department of Gastroenterology and Hepatology, University Hospitals Leuven, Leuven, Belgium
| | - Rastislav Kunda
- Department of Surgery, Department of Gastroenterology and Hepatology, and Department of Advanced Interventional Endoscopy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Simon M Everett
- Department of Gastroenterology and Hepatology, Leeds Teaching Hospital NHS Trust, Leeds, UK
| | - Sundeep Lakhtakia
- Department of Medical Gastroenterology, Asian Institute of Gastroenterology Hospitals, Gachibowli, Hyderabad, India
| | - Mihai Rimbas
- Gastroenterology Department, Colentina Clinical Hospital, Bucharest, Romania
| | - Tomas Hucl
- Department of Gastroenterology and Hepatology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Abdenor Badaoui
- Department of Gastroenterology and Hepatology, Université catholique de Louvain, CHU UCL Namur, Yvoir, Belgium
| | - Ryan Law
- Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - Paolo Giorgio Arcidiacono
- Pancreatobiliary Endoscopy and Endosonography Division, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Alberto Larghi
- Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, and Center for Endoscopic Research Therapeutics and Training, Catholic University, Rome, Italy
| | - Marc Giovannini
- Paoli-Calmettes Institute, Department of Gastrointestinal Disease, Marseille, France
| | - Mouen A Khashab
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, Maryland, USA
| | - Kenneth F Binmoeller
- Interventional Endoscopy Services, California Pacific Medical Center, San Francisco, California, USA
| | - Marc Barthet
- Department of Gastroenterology, Aix-Marseille Université, APHM, Hôpital Nord, Marseille, France
| | - Manuel Pérez-Miranda
- Gastroenterology Department, Hospital Universitario Rio Hortega, Valladolid, Spain
| | - Jeanin E van Hooft
- Department of Gastroenterology and Hepatology, Leiden University Medical Center, Leiden, The Netherlands
| | - Schalk W van der Merwe
- Department of Gastroenterology and Hepatology, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
18
|
Troubleshooting Difficult Bile Duct Access: Advanced ERCP Cannulation Techniques, Percutaneous Biliary Drainage, or EUS-Guided Rendezvous Technique? GASTROENTEROLOGY INSIGHTS 2021. [DOI: 10.3390/gastroent12040039] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Despite experienced hands and availability of various well-designed catheters and wires, selective bile duct cannulation may still fail in 10–20% of cases during endoscopic retrograde cholangiopancreatography (ERCP). In case standard ERCP cannulation technique fails, salvage options include advanced ERCP cannulation techniques such as double-guidewire technique (DGW) with or without pancreatic stenting and precut papillotomy, percutaneous biliary drainage (PBD), and endoscopic ultrasound-guided Rendezvous (EUS-RV) ERCP. If the pancreatic duct is inadvertently entered during cannulation attempts, DGW technique is a reasonable next step, which can be followed by pancreatic stenting to reduce risks of post-ERCP pancreatitis (PEP). Studies suggest that early precut papillotomy is not associated with a higher risk of PEP, while needle-knife fistulotomy is the preferred method. For patients with critical clinical condition who may not be fit for endoscopy, surgically altered anatomy in which endoscopic biliary drainage is not feasible, and non-communicating multisegmental biliary obstruction, PBD has a unique role to provide successful biliary drainage efficiently in this particular population. As endoscopic ultrasound (EUS)-guided biliary drainage techniques advance, EUS-RV ERCP has been increasingly employed to guide bile duct access and cannulation with satisfactory clinical outcomes and is especially valuable for benign pathology at centres where expertise is available. Endoscopists should become familiar with each technique’s advantages and limitations before deciding the most appropriate treatment that is tailored to patient’s anatomy and clinical needs.
Collapse
|