Niyatiwatchanchai N, Thengchaisri N. Effects of pressure- and volume-controlled ventilation on the work of breathing in cats using a cuffed endotracheal tube.
Vet World 2021;
14:2568-2573. [PMID:
34840479 PMCID:
PMC8613800 DOI:
10.14202/vetworld.2021.2568-2573]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 08/24/2021] [Indexed: 11/21/2022] Open
Abstract
Background and Aim:
Mechanical ventilation is essential for supporting patients’ respiratory function when they are under general anesthesia. For cats with limited lung capacity, the different effects of volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) on respiratory function remain elusive. The objective of the present study was to compare the efficacy of VCV and PCV in cats under general anesthesia using a cuffed endotracheal tube (ETT).
Materials and Methods:
Twelve healthy cats were randomly allocated to either a VCV or PCV group. Five tidal volumes (6, 8, 10, 12, and 14 mL/kg) were randomly applied to assess the efficacy of VCV, and respiratory rates were adjusted to achieve a minute ventilation of 100 mL/kg/min. Peak inspiratory pressures (4, 5, 6, 7, and 8 mmHg) were randomly applied to assess the efficacy of PCV, and respiratory rates were adjusted to achieve a minute ventilation of 100 mL/kg/min. Blood pressure, gas leakages, and end-tidal CO2 were recorded from 60 trials for airway control during the use of VCV or PCV. Data were compared using Fisher’s exact test with a significance level of p<0.05.
Results:
Leakages did not differ between VCV (1/60 events) and PCV (0/60 events; p=0.500). Hypercapnia was identified when using VCV (6/60 events) less frequently than when using PCV (7/60 events; p=0.762), but did not reach statistical significance. Hypotension (mean arterial blood pressure <60 mmHg) occurred less frequently with VCV (0/60 events) than with PCV (9/60 events; p=0.003). Moreover, VCV provided a significantly lower work of breathing (151.10±65.40 cmH2O mL) compared with PCV (187.84±89.72 cmH2O mL; p<0.05).
Conclusion:
VCV in cats using a cuffed ETT causes less hypotension than PCV. It should be noted that VCV provides a more stable tidal volume compared with PCV, resulting in a more stable minute volume. Nonetheless, VCV should not be used in patients with an airway obstruction because higher peak airway pressure may occur and lead to lung injury.
Collapse