1
|
Skočir A, Jevšnik A, Plaskan L, Podbregar M. Functional Magnetic Neuromuscular Stimulation vs. Routine Physiotherapy in the Critically Ill for Prevention of ICU Acquired Muscle Loss: A Randomised Controlled Trial. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1724. [PMID: 39459511 PMCID: PMC11509331 DOI: 10.3390/medicina60101724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Revised: 10/15/2024] [Accepted: 10/18/2024] [Indexed: 10/28/2024]
Abstract
Background and Objectives: Muscle loss is a known complication of ICU admission. The aim of the study was to investigate the effect of neuromuscular functional magnetic stimulation (FMS) on quadriceps muscle thickness in critically ill patients. Materials and Methods: Among ICU patients one quadriceps was randomized to FMS (Tesla Stym, Iskra Medical, Ljubljana, Slovenia) stimulation and the other to control care. Quadriceps thickness was measured by ultrasound (US) in transversal and longitudinal planes at enrolment, Days 3-5, and Days 9-12. The trial stopped early following an interim analysis comparing muscle thickness differences between groups using repeated measures ANOVA. Results: Of 18 patients randomized, 2 died before completing the trial. The final analysis reported included 16 patients (female 38%, age 68 ± 10 years, SOFA 10.8 ± 2.7). Three mild skin thermal injuries were noted initially, which were later avoided with proper positioning of FMS probe. Primary outcome comparison showed that quadriceps thickness in transversal and longitudinal planes decreased in the non-stimulated legs and, but it did not change in FMS legs (-4.1 mm (95%CI: -9.4 to -0.6) vs. -0.7 mm (95%CI: -4.1 to -0.7) (p = 0.03) and -4.4 mm (95%CI: -8.9 to -1.1) vs. -1.5 mm (95%CI: -2.6 to -2.2) (p = 0.02), respectively) (ANOVA difference between groups p = 0.036 and 0.01, respectively). Conclusions: In the critically ill, neuromuscular FMS is feasible and safe with precautions applied to avoid possible skin thermal injury. FMS decreases the loss of quadriceps muscle thickness.
Collapse
Affiliation(s)
- Anej Skočir
- Department for Medical ICU, General and Teaching Hospital Celje, 3000 Celje, Slovenia;
| | - Alja Jevšnik
- Department for Medical Rehabilitation, General and Teaching Hospital Celje, 3000 Celje, Slovenia
| | - Lidija Plaskan
- Department for Medical Rehabilitation, General and Teaching Hospital Celje, 3000 Celje, Slovenia
| | - Matej Podbregar
- Department for Medical ICU, General and Teaching Hospital Celje, 3000 Celje, Slovenia;
- Department for Internal Medicine, Medical Faculty, University of Ljubljana, 1000 Ljubljana, Slovenia
| |
Collapse
|
2
|
Chandrasekaran A, Pal D, Harne R, Patel SJ, Jagadeesh KN, Pachisia AV, Tyagi P, Brar K, Pattajoshi S, Patel PB, Zatakiya R, Govil D. Comparison between Effect of Indirect Calorimetry vs Weight-based Equation (25 kcal/kg/day)-guided Nutrition on Quadriceps Muscle Thickness as Assessed by Bedside Ultrasonography in Medical Intensive Care Unit Patients: A Randomized Clinical Trial. Indian J Crit Care Med 2024; 28:587-594. [PMID: 39130394 PMCID: PMC11310671 DOI: 10.5005/jp-journals-10071-24737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 05/04/2024] [Indexed: 08/13/2024] Open
Abstract
Aim and background Sarcopenia is a substantial contributor to intensive care unit (ICU)-acquired weakness and is associated with significant short- and long-term outcomes. It can, however, be mitigated by providing appropriate nutrition. Indirect calorimetry (IC) is believed to be the gold standard in determining caloric targets in the dynamic environment of critical illness. We conducted this study to compare the effect of IC vs weight-based (25 kcal/kg/day) feeding on quadriceps muscle thickness (QMT) by ultrasound in critically ill patients. Materials and methods A prospective study was conducted on 60 mechanically ventilated patients randomized to two groups [weight-based equation (WBE) group or the IC group] in medical ICU after obtaining institutional ethics committee approval, and fed accordingly. The right QMT measurement using ultrasound and caloric targets were documented on day 1, 3 and 7 and analyzed statistically. The IC readings were obtained from the metabolic cart E-COVX ModuleTM. Results The baseline demographics, APACHE-II, NUTRIC score, and SOFA scores on day 1, 3, and 7 were comparable between the two groups. The resting energy expenditure (REE) obtained in the IC group was significantly less than the WBE energy targets and the former were fed with significantly less calories. A significantly less percent reduction of QMT in the IC group compared with the WBE group was observed from day 1 to day 3, day 3 to day 7, and day 1 to day 7. Conclusion From our study, we conclude that IC-REE-based nutrition is associated with lesser reduction in QMT and lesser calories fed in critically ill mechanically ventilated patients compared from WBE. CTRI registration-CTRI/2023/01/049119. How to cite this article Chandrasekaran A, Pal D, Harne R, Patel SJ, Jagadeesh KN, Pachisia AV, et al. Comparison between Effect of Indirect Calorimetry vs Weight-based Equation (25 kcal/kg/day)-guided Nutrition on Quadriceps Muscle Thickness as Assessed by Bedside Ultrasonography in Medical Intensive Care Unit Patients: A Randomized Clinical Trial. Indian J Crit Care Med 2024;28(6):587-594.
Collapse
Affiliation(s)
- Aravind Chandrasekaran
- Department of Critical Care Medicine, K.K. Patel Super Specialty Hospital, Bhuj, Gujarat, India
| | - Divya Pal
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Rahul Harne
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Sweta J Patel
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - KN Jagadeesh
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Anant V Pachisia
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Pooja Tyagi
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Keerti Brar
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Swagat Pattajoshi
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Parimal B Patel
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Ronak Zatakiya
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| | - Deepak Govil
- Institute of Critical Care and Anaesthesia, Medanta – The Medicity, Gurugram, Haryana, India
| |
Collapse
|
3
|
Lee YH, Bae H, Chun YH, Lee JW, Kim HJ. Ultrasonographic examination of masticatory muscles in patients with TMJ arthralgia and headache attributed to temporomandibular disorders. Sci Rep 2024; 14:8967. [PMID: 38637633 PMCID: PMC11026518 DOI: 10.1038/s41598-024-59316-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 04/09/2024] [Indexed: 04/20/2024] Open
Abstract
This study used ultrasonography to compare the thickness and cross-sectional area of the masticatory muscles in patients with temporomandibular joint arthralgia and investigated the differences according to sex and the co-occurrence of headache attributed to temporomandibular disorders (HATMD). The observational study comprised 100 consecutive patients with TMJ arthralgia (71 females and 29 males; mean age, 40.01 ± 17.67 years) divided into two groups: Group 1, including 86 patients with arthralgia alone (60 females; 41.15 ± 17.65 years); and Group 2, including 14 patients with concurrent arthralgia and HATMD (11 females; 33.00 ± 16.72 years). The diagnosis of TMJ arthralgia was based on the diagnostic criteria for temporomandibular disorders. The parameters of the masticatory muscles examined by ultrasonography were subjected to statistical analysis. The pain area (2.23 ± 1.75 vs. 5.79 ± 2.39, p-value = 0.002) and visual analog scale (VAS) score (3.41 ± 1.82 vs. 5.57 ± 12.14, p-value = 0.002) were significantly higher in Group 2 than in Group 1. Muscle thickness (12.58 ± 4.24 mm) and cross-sectional area (4.46 ± 2.57 cm2) were larger in the masseter muscle than in the other three masticatory muscles (p-value < 0.001). When examining sex-based differences, the thickness and area of the masseter and lower temporalis muscles were significantly larger in males (all p-value < 0.05). The area of the masseter muscle (4.67 ± 2.69 vs. 3.18 ± 0.92, p-value = 0.004) and lower temporalis muscle (3.76 ± 0.95 vs. 3.21 ± 1.02, p-value = 0.049) was significantly smaller in Group 2 than in Group 1. An increase in VAS was significantly negatively correlated with the thickness of the masseter (r = - 0.268) and lower temporalis (r = - 0.215), and the cross-sectional area of the masseter (r = - 0.329) and lower temporalis (r = - 0.293). The masseter and lower temporalis muscles were significantly thinner in females than in males, and their volumes were smaller in patients with TMJ arthralgia and HATMD than in those with TMJ arthralgia alone. HATMD and decreased masseter and lower temporalis muscle volume were associated with increased pain intensity.
Collapse
Affiliation(s)
- Yeon-Hee Lee
- Department of Orofacial Pain and Oral Medicine, Kyung Hee University, Kyung Hee University Dental Hospital, #613 Hoegi-dong, Dongdaemun-gu, Seoul, 02447, South Korea.
| | - Hyungkyu Bae
- Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, Seoul, South Korea
| | - Yang-Hyun Chun
- Department of Orofacial Pain and Oral Medicine, Kyung Hee University, Kyung Hee University Dental Hospital, #613 Hoegi-dong, Dongdaemun-gu, Seoul, 02447, South Korea
| | - Jung-Woo Lee
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, Seoul, 02447, South Korea.
| | - Hee-Jin Kim
- Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, Seoul, South Korea
| |
Collapse
|
4
|
Lima J, Foletto E, Cardoso RCB, Garbelotto C, Frenzel AP, Carneiro JU, Carpes LS, Barbosa-Silva TG, Gonzalez MC, Silva FM. Ultrasound for measurement of skeletal muscle mass quantity and muscle composition/architecture in critically ill patients: A scoping review on studies' aims, methods, and findings. Clin Nutr 2024; 43:95-110. [PMID: 38016244 DOI: 10.1016/j.clnu.2023.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 10/24/2023] [Accepted: 11/06/2023] [Indexed: 11/30/2023]
Abstract
AIMS This scoping review aimed to identify, explore, and map the objectives, methodological aspects, and results of studies that used ultrasound (US) to assess skeletal muscle (SM) in critically ill patients. METHODS A scoping review was conducted according to the Joanna Briggs Institute's methodology. All studies that evaluated SM parameters from the US in patients admitted to the intensive care unit (ICU) were considered eligible. We categorized muscle thickness and cross-sectional area as parameters for assessing SM quantity, while echogenicity, fascicle length, and pennation angle analysis were used to evaluate muscle "quality" (composition/architecture). A literature search was conducted using four databases for articles published until December 2022. Independent reviewers selected the studies and extracted data. Descriptive statistics were calculated to present the results. RESULTS A total of 107 studies were included, the majority of which were prospective cohort studies (59.8 %) conducted in general ICUs (49.5 %). The most frequent objective of the studies was to evaluate SM quantity depletion during the ICU stay (25.2 %), followed by determining whether a specific intervention would modify SM (21.5 %). Most studies performed serial SM evaluations (76.1 %). The rectus femoris muscle thickness was evaluated in most studies (67.9 %), followed by the rectus femoris cross-sectional area (54.3 %) and the vastus intermedius muscle thickness (40.2 %). The studies demonstrated the feasibility and reproducibility of US for SM evaluation, especially related to quantitative parameters. Most studies (70.3 %) reported significant SM quantity depletion during hospitalization. However, the accuracy of the US in measuring SM varied across the studies. CONCLUSIONS The lack of detailed description and standardization in the protocols adopted by the studies included in this scoping review precludes the translation of the evidence related to US for SM assessment into clinical practice.
Collapse
Affiliation(s)
- Júlia Lima
- Nutrition Science Graduate Program, Federal University of Health Sciences of Porto Alegre, Porto Alegre Brazil
| | - Estéfani Foletto
- Nutrition Course, Department, Federal University of Health Sciences of Porto Alegre, Porto Alegre Brazil
| | - Rafaella C B Cardoso
- Nutrition Course, Department, Federal University of Health Sciences of Porto Alegre, Porto Alegre Brazil
| | - Charlles Garbelotto
- Nutrition Course, Department, Federal University of Health Sciences of Porto Alegre, Porto Alegre Brazil
| | - Aline P Frenzel
- Postgraduate Program in Health and Behavior, Catholic University of Pelotas, Pelotas Brazil
| | - Juliana U Carneiro
- Multiprofessional Residency Program: Intensive Care. Federal University of Health Sciences of Porto Alegre, Porto Alegre Brazil
| | - Larissa S Carpes
- Santa Casa de Misericórdia de Porto Alegre Hospital, Porto Alegre Brazil
| | - Thiago G Barbosa-Silva
- Department of General Surgery, Faculty of Medicine, Federal University of Pelotas, Pelotas Brazil
| | | | - Flávia M Silva
- Nutrition Department and Nutrition Science Graduate Program. Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre Brazil.
| |
Collapse
|
5
|
Mechelli F, Bayford R, Garelick H, Stokes M, Agyapong-Badu S. Clinical Utility of Ultrasound Imaging for Measuring Anterior Thigh Thickness after Anterior Cruciate Ligament Injury in an Individual Patient to Assess Postsurgery Outcome. Case Rep Orthop 2023; 2023:6672951. [PMID: 37908634 PMCID: PMC10615585 DOI: 10.1155/2023/6672951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/02/2023] [Accepted: 10/05/2023] [Indexed: 11/02/2023] Open
Abstract
The present study investigated the clinical utility of ultrasound imaging (USI) for assessing changes in an individual's quadriceps muscle and subcutaneous fat (SF) thickness of the anterior thigh and their relative proportions. A patient was studied prior to and after anterior cruciate ligament reconstruction (ACLR) surgery and during rehabilitation. This case study involved an 18-year-old female recreational athlete with a complete tear of the anterior cruciate ligament (ACL). Tissue thickness (SF and quadriceps muscle) was measured from transverse USI of the anterior thigh before surgery, at weekly intervals during 12 weeks of postsurgery, and then every 2 weeks for the following 12 weeks (total of 21 measurement sets). Statistically significant differences presurgery to postrehabilitation were found for muscle thickness (p = 0.04) and SF tissue thickness (p = 0.04) measurements. There was no difference in muscle to fat ratio (p = 0.08). Changes in measurements greater than the reported minimal detectable change (MDC) demonstrate the sensitivity of the USI technique as an objective tool to assess clinically useful changes in an individual's anterior thigh muscle thickness post-ACLR surgery and during rehabilitation.
Collapse
Affiliation(s)
- Filippo Mechelli
- Private practice, Urbino, Italy
- Faculty of Science and Technology, Department of Natural Sciences, Middlesex University, London, UK
| | - Richard Bayford
- Faculty of Science and Technology, Department of Natural Sciences, Middlesex University, London, UK
| | - Hemda Garelick
- Faculty of Science and Technology, Department of Natural Sciences, Middlesex University, London, UK
| | - Maria Stokes
- School of Health Sciences, University of Southampton, Southampton, UK
- Centre for Sport, Exercise and Osteoarthritis versus Arthritis, Southampton, UK
- Southampton NIHR Biomedical Research Centre, UK
| | - Sandra Agyapong-Badu
- School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Edgbaston, Birmingham, UK
| |
Collapse
|
6
|
Deng P, Ozaki H, Natsume T, Ke D, Lu D, Suzuki K, Naito H. Associations of Morphological Changes in Skeletal Muscles of Preschool Children in China Following Physical Activity. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1538. [PMID: 37761499 PMCID: PMC10529834 DOI: 10.3390/children10091538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 08/26/2023] [Accepted: 09/06/2023] [Indexed: 09/29/2023]
Abstract
PURPOSE Physical activity (PA) is likely to be the most important modifiable factor in skeletal muscle development. However, the influence of PA on the skeletal muscle of preschool children has not been thoroughly investigated. The main objective of this study was to quantitatively measure PA, and then, to assess whether associations exist between site-specific muscle changes and PA in relation to sex and weight statuses in preschool children aged 3 to 4 years. METHODS A total of 86 healthy preschool children, aged 3-4 years, were instructed to wear an accelerometer for seven consecutive days. The number of steps taken daily, and minutes spent in moderate-vigorous PA (MVPA) and total PA (TPA) were recorded. Muscle thickness was measured by B-mode ultrasonography using a 5-18 MHz scanning head. Muscle thickness was measured at seven sites: the lateral forearm, upper arm, abdomen, anterior and posterior thigh, and anterior and posterior lower leg. RESULTS There was no significant difference between boys and girls in terms of MVPA and TPA on weekdays and weekends. According to the linear regression models, after adjusting for daylight duration, the muscle of the posterior thigh was significantly positively associated (p < 0.05) with daily steps and MVPA on weekdays for boys and girls, respectively. CONCLUSIONS We found that the muscle thickness of the posterior thigh in preschool children was significantly positively associated with PA, as measured by daily steps and MVPA. We suggest that for the overall health and well-being of preschool children, the levels of PA should be maintained and/or increased, and preferably transformed into a regular part of daily living.
Collapse
Affiliation(s)
- Pengyu Deng
- Graduate School of Health and Sports Science, Juntendo University, Chiba 270-1695, Japan; (K.S.); (H.N.)
- Institute of Health and Sports Science & Medicine, Juntendo University, Chiba 270-1695, Japan; (H.O.); (D.K.)
| | - Hayao Ozaki
- Institute of Health and Sports Science & Medicine, Juntendo University, Chiba 270-1695, Japan; (H.O.); (D.K.)
- School of Sport and Health Science, Tokai Gakuen University, Miyoshi 470-0207, Japan
| | - Toshiharu Natsume
- Department of Human Structure & Function, Tokai University School of Medicine, Isehara 259-1193, Japan;
| | - Dandan Ke
- Institute of Health and Sports Science & Medicine, Juntendo University, Chiba 270-1695, Japan; (H.O.); (D.K.)
- School of Public Health, Fudan University, Shanghai 200433, China
| | - Dajiang Lu
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China;
| | - Koya Suzuki
- Graduate School of Health and Sports Science, Juntendo University, Chiba 270-1695, Japan; (K.S.); (H.N.)
- Institute of Health and Sports Science & Medicine, Juntendo University, Chiba 270-1695, Japan; (H.O.); (D.K.)
| | - Hisashi Naito
- Graduate School of Health and Sports Science, Juntendo University, Chiba 270-1695, Japan; (K.S.); (H.N.)
- Institute of Health and Sports Science & Medicine, Juntendo University, Chiba 270-1695, Japan; (H.O.); (D.K.)
| |
Collapse
|
7
|
Reliability and feasibility of skeletal muscle ultrasound in the acute burn setting. Burns 2023; 49:68-79. [PMID: 35361498 DOI: 10.1016/j.burns.2022.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 02/11/2022] [Accepted: 03/12/2022] [Indexed: 01/06/2023]
Abstract
OBJECTIVES Despite the impact of muscle wasting after burn, tools to quantify muscle wasting are lacking. This multi-centre study examined the utility of ultrasound to measure muscle mass in acute burn patients comparing different methodologies. METHODS B-mode ultrasound was used by two raters to determine feasibility and inter-rater reliability in twenty burned adults following admission. Quadriceps muscle layer thickness (QMLT) and rectus femoris cross-sectional area (RF-CSA) were measured, comparing the use of i) a single versus average measurements, ii) a proximal versus distal location for QMLT, and iii) a maximum- versus no-compression technique for QMLT. RESULTS Analysis of twenty burned adults (50 years [95%CI 42-57], 32%TBSA [95%CI 23-40]) yielded ICCs of> 0.97 for QMLT (for either location and compression technique) and> 0.95 for RF-CSA, using average measurements. Relative minimal detectable changes were smaller using no-compression than maximum-compression (6.5% vs. 15%). Using no-compression to measure QMLT was deemed feasible for both proximal and distal locations (94% and 96% of attempted measurements). In 9.5% of cases maximum-compression was not feasible. 95% of RF-CSA measurements were successfully completed. CONCLUSION Ultrasound provides feasible and reliable values of quadriceps muscle architecture that can be adapted to clinical scenarios commonly encountered in acute burn settings.
Collapse
|
8
|
The Diagnostic Value of Ultrasound of the Rectus Femoris for the diagnosis of Sarcopenia in adults: A systematic review. Injury 2022; 53 Suppl 3:S23-S29. [PMID: 35732560 DOI: 10.1016/j.injury.2022.06.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 05/27/2022] [Accepted: 06/06/2022] [Indexed: 02/02/2023]
Abstract
BACKGROUND & AIM Sarcopenia is defined as a loss of muscle mass and function, which can be caused by normal ageing or factors such as physical inactivity. Severe health consequences caused by sarcopenia highlight the need for early identification. Computed Tomography (CT) imaging, often mentioned as the gold standard due to its accuracy, is costly and not routinely performed in daily clinical care. Ultrasound of the rectus femoris, however, is low in costs and easily accessible. The aim is to present the current and most recent literature regarding the diagnostic value of ultrasound measurements of the rectus femoris for the diagnosis of sarcopenia in adults. METHODS The databases PubMed and Web of Science were used to search for studies comparing ultrasound of the rectus femoris with a reference test to diagnose sarcopenia in adults. The quality of the final eligible studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies, version 2, tool (QUADAS-2). RESULTS Six studies were included in this systematic review. The muscle thickness and cross-sectional area of the rectus femoris were assessed and compared with the reference tests CT, Dual-Energy X-ray Absorptiometry (DXA), and Bioelectrical Impedance Analysis (BIA). Half of the studies had a low risk of bias on all QUADAS-2 domains. Three studies reported statistical significant outcomes and diagnostic values ranging from 60 to 81% sensitivity and 51 to 94% specificity. CONCLUSIONS Ultrasound of the rectus femoris muscle to diagnose sarcopenia has been shown to be a promising method in multiple clinical populations. However, there were some limitations such as a high methodological heterogeneity. Future research should develop standardized protocols and determine clear cut-off values to allow for a better implementation of ultrasound in clinical practice.
Collapse
|
9
|
Pinto-Ramos J, Costa-Santos C, Costa F, Tavares H, Cabral J, Moreira T, Brito R, Barroso J, Sousa-Pinto B. Reliability of point-of-care ultrasound for measuring quadriceps femoris muscle thickness. Eur J Phys Rehabil Med 2022; 58:767-773. [PMID: 36052891 PMCID: PMC10019477 DOI: 10.23736/s1973-9087.22.07432-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Point-of-care ultrasound can be used to assess muscle thickness. However, its reliability has not been fully evaluated. AIM This study aimed to assess the intrarater and inter-rater reliability of point-of-care ultrasound for the estimation of quadriceps and rectus femoris thickness in patients from a rehabilitation setting. DESIGN This is a cross-sectional study. SETTING This study was conducted at the Department of Physical Medicine and Rehabilitation of a tertiary care hospital. POPULATION Twenty-nine inpatients consecutively selected after admission. METHODS Four observers, two trained and two untrained, used point-of-care ultrasound to measure quadriceps femoris and rectus femoris thickness. Each observer performed two measurements followed by a second set of two measurements three hours later. Intraclass correlation coefficients (ICC) were then calculated. RESULTS Both intrarater and inter-rater ICC were higher than 0.888 for both quadriceps and rectus femoris measurements. Reliability was highest when ICC were calculated based on the average of two measurements, with the intrarater ICC being of 0.956 (95% CI: 0.937-0.970) for rectus femoris and of 0.966 (95% CI: 0.951-0.976) for quadriceps femoris; and with the inter-rater ICC being of 0.919 (95% CI: 0.863-0.957) for rectus femoris and 0.945 (95% CI: 0.907- 0.971) for quadriceps femoris. Trained and untrained observers did not have significantly different ICC values. CONCLUSIONS These results suggest that point-of-care ultrasound is a reliable option to measure muscle thickness of knee extensors by the same or different observers. CLINICAL REHABILITATION IMPACT Measuring knee extensors thickness may aid to adequately modulate treatment choices in patients with disability. This study suggests that quadriceps and rectus femoris muscle thickness measured after a short training course, by either an experienced or inexperienced clinician, presents high reliability. Reliability can be increased if the average of two measurements is used. Besides being inexpensive and portable, point-of-care ultrasound is a reliable tool for measuring knee extensors' thickness, rendering it potentially adequate to be used in clinical practice.
Collapse
Affiliation(s)
- João Pinto-Ramos
- Department of Physical Medicine and Rehabilitation, São João University Hospital Center, Porto, Portugal - .,Center for Health Technologies and Services Research - CINTESIS, University of Porto, Porto, Portugal -
| | - Cristina Costa-Santos
- Center for Health Technologies and Services Research - CINTESIS, University of Porto, Porto, Portugal.,Department of Community Medicine, Information and Health Decision Sciences - MEDCIDS, Faculty of Medicine, University of Porto, Porto, Portugal
| | - Frederico Costa
- Department of Physical Medicine and Rehabilitation, São João University Hospital Center, Porto, Portugal
| | - Helena Tavares
- Department of Physical Medicine and Rehabilitation, São João University Hospital Center, Porto, Portugal
| | - João Cabral
- Department of Physical Medicine and Rehabilitation, São João University Hospital Center, Porto, Portugal
| | - Tiago Moreira
- Department of Physical Medicine and Rehabilitation, São João University Hospital Center, Porto, Portugal
| | - Rui Brito
- Department of Physical Medicine and Rehabilitation, Centro Hospitalar do Porto, Porto, Portugal
| | - Joana Barroso
- Department of Physical Medicine and Rehabilitation, São João University Hospital Center, Porto, Portugal.,Department of Biomedicine, Faculty of Medicine, University of Porto, Porto, Portugal.,Institute for Health Research and Innovation - i3s, University of Porto, Porto, Portugal.,Feinberg School of Medicine, Departments of Neuroscience and Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, USA
| | - Bernardo Sousa-Pinto
- Center for Health Technologies and Services Research - CINTESIS, University of Porto, Porto, Portugal.,Department of Community Medicine, Information and Health Decision Sciences - MEDCIDS, Faculty of Medicine, University of Porto, Porto, Portugal
| |
Collapse
|
10
|
Högelin ER, Thulin K, von Walden F, Fornander L, Michno P, Alkner B. Reliability and Validity of an Ultrasound-Based Protocol for Measurement of Quadriceps Muscle Thickness in Children. Front Physiol 2022; 13:830216. [PMID: 35832479 PMCID: PMC9272772 DOI: 10.3389/fphys.2022.830216] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 06/06/2022] [Indexed: 11/15/2022] Open
Abstract
Introduction and aims: Accurate determination of skeletal muscle size is of great importance in multiple settings including resistance exercise, aging, disease, and disuse. Ultrasound (US) measurement of muscle thickness (MT) is a method of relatively high availability and low cost. The present study aims to evaluate a multisite ultrasonographic protocol for measurement of MT with respect to reproducibility and correlation to gold-standard measurements of muscle volume (MV) with magnetic resonance imaging (MRI) in children. Material and methods: 15 children completed the study (11 ± 1 year, 41 ± 8 kg, 137 ± 35 cm). Following 20 min supine rest, two investigators performed US MT measurements of all four heads of the m. quadriceps femoris, at pre-determined sites. Subsequently, MRI scanning was performed and MV was estimated by manual contouring of individual muscle heads. Results: Ultrasound measurement of MT had an intra-rater reliability of ICC = 0.985–0.998 (CI 95% = 0.972–0.998) and inter-rater reliability of ICC = 0.868–0.964 (CI 95% = 0.637–0.983). The US examinations took less than 15 min, per investigator. Muscle thickness of all individual quadriceps muscles correlated significantly with their corresponding MV as measured by MRI (overall r = 0.789, p < 0.001). Conclusion: The results of this study indicate that US measurement of MT using a multisite protocol is a competitive alternative to MRI scanning, especially with respect to availability and time consumption. Therefore, US MT could allow for wider clinical and scientific implementation.
Collapse
Affiliation(s)
- Emil Rydell Högelin
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.,Futurum - Academy for Health and Care, Jönköping, Sweden
| | - Kajsa Thulin
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.,Department of Orthopaedic Surgery, Eksjö, Jönköping, Sweden
| | - Ferdinand von Walden
- Department of Paediatrics, Karolinska University Hospital, Stockholm, Sweden.,Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Lotta Fornander
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.,Department of Orthopedic Surgery, Norrköping, Sweden
| | - Piotr Michno
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.,Department of Orthopaedic Surgery, Jönköping, Sweden
| | - Björn Alkner
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.,Department of Orthopaedic Surgery, Eksjö, Jönköping, Sweden
| |
Collapse
|
11
|
González-Seguel F, Pinto-Concha JJ, Ríos-Castro F, Silva-Gutiérrez A, Camus-Molina A, Mayer KP, Parry SM. Evaluating a Muscle Ultrasound Education Program: Theoretical Knowledge, Hands-on Skills, Reliability, and Satisfaction of Critical Care Physiotherapists. Arch Rehabil Res Clin Transl 2021; 3:100142. [PMID: 34589692 PMCID: PMC8463476 DOI: 10.1016/j.arrct.2021.100142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To evaluate learning results of critical care physiotherapists participating in a muscle ultrasound (MUS) educational program. DESIGN Cross-sectional study. SETTING A custom-made 20-hour MUS course was performed over a 2-week time period, including knobs familiarization, patient positioning, anatomic landmarks, image acquisition, and limb muscle measurements. PARTICIPANTS Nineteen critical care physiotherapists with little to no prior experience in ultrasound (N=19). INTERVENTIONS Not applicable. MAIN OUTCOME MEASURES Theoretical knowledge, hands-on skills acquisition, and satisfaction were assessed. Inter- and intrarater reliability on landmarks, thickness, and pennation angle of quadriceps between participants was evaluated using intraclass correlation coefficients (ICCs). Reliability among instructors measured prior to the course was also reported as a reference. RESULTS The percentage score (mean±SD) of knowledge questionnaires was 69±11 (pre-course), 89±10 (post-course), and 92±9 (hands-on skills). Course satisfaction scores ranged from 90%-100%. Pooled interrater reliability of participants (median ICC [interquartile range]) was good (0.70 [0.59-0.79]) for thickness, moderate (0.47 [0.46-0.92]) for landmarks, and absent (0.00 [0.00-0.05]) for pennation angle and the intrarater reliability was good (0.76 [0.51-0.91]) for thickness and weak (0.35 [0.29-0.52]) for pennation angle. Interrater ICC values for instructors were excellent (0.90) for thickness, good (0.67) for landmarks, and moderate (0.41) for pennation angle and intrarater ICC values were excellent (0.94) for thickness and good (0.75) for pennation angle. CONCLUSIONS Although our sample was quite small and homogeneous, increased theoretical knowledge, high hands-on performance acquisition, and good satisfaction of physiotherapists were observed. Reliability was moderate to excellent for thickness and landmarks and absent to weak for pennation angle. Landmarking and pennation angle remain challenges for physiotherapist training in the application of MUS. Further studies are needed to identify variables that could modify reliability during MUS training.
Collapse
Key Words
- CV, coefficient of variation
- Critical care
- Education
- ICC, intraclass correlation coefficient
- ICU, intensive care unit
- IQR, interquartile range
- Knowledge assessment
- MUS, muscle ultrasound
- Muscular atrophy
- PA, pennation angle
- Physiotherapy
- QC, quadriceps complex
- RF, rectus femoris
- Rehabilitation
- SEM, standard error of measurement
- Ultrasonography
- VI, vastus intermedius
- VL, vastus lateralis
Collapse
Affiliation(s)
- Felipe González-Seguel
- Servicio de Medicina Física y Rehabilitación and Departamento de Paciente Crítico, Facultad de Medicina, Clínica Alemana Universidad del Desarrollo, Santiago, Chile
| | | | - Francisco Ríos-Castro
- Servicio de Medicina Física y Rehabilitación and Departamento de Paciente Crítico, Facultad de Medicina, Clínica Alemana Universidad del Desarrollo, Santiago, Chile
| | | | - Agustín Camus-Molina
- Servicio de Medicina Física y Rehabilitación and Departamento de Paciente Crítico, Facultad de Medicina, Clínica Alemana Universidad del Desarrollo, Santiago, Chile
| | - Kirby P. Mayer
- Department of Physical Therapy, College of Health Sciences, University of Kentucky, Lexington, KY
| | - Selina M. Parry
- Department of Physiotherapy, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
12
|
Takahashi Y, Fujino Y, Miura K, Toida A, Matsuda T, Makita S. Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals. Ultrasound J 2021; 13:21. [PMID: 33856566 PMCID: PMC8050162 DOI: 10.1186/s13089-021-00224-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 01/19/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Ultrasonography (US) is a feasible and accessible method for the measurement of skeletal muscle mass. This technique presents acceptable intra-rater reliability; however, there are a few reports on its inter-rater reliability. Additionally, relative reliability should equally be inspected to determine the presence of systematic errors. Therefore, this study aimed to investigate the intra- and inter-rater reliabilities and absolute reliability of rectus femoris muscle thickness as measured using US. METHODS The participants included in our study comprised 12 healthy young men (26.5 ± 3.9 years. Rectus femoris muscle thickness was measured from the right side of the thigh using US by two trained physical therapists. Inter- and intra-rater reliabilities were determined using the intraclass correlation coefficient (ICC) (1, 1) and ICC (2, 1) methods, respectively. Absolute reliability was evaluated using Bland - Altman analysis. Additionally, we calculated the minimal detectable change at the 95% level of confidence (MDC95). RESULT According to the results of the Bland - Altman analysis, no fixed or proportional errors were present. The ICC (1, 1) was 0.95, and the ICC (2, 1) was 0.70. The MDC95 values of rectus femoris thickness for the intra- and inter-rater reliabilities were 2.0 mm and 4.3 mm, respectively. CONCLUSIONS In our study, intra- and inter-rater reliabilities were measured at "excellent" and "moderate" levels in the healthy individuals based on a previously defined scale. Moreover, we determined the measurement error for quantifying rectus femoris thickness. Therefore, the measurement of rectus femoris thickness using US could be considered applicable in clinical research.
Collapse
Affiliation(s)
- Yosuke Takahashi
- Department of Rehabilitation Center, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Yuji Fujino
- Department of Physical Therapy, Faculty of Health Science, Juntendo University, 3-2-12, Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
| | - Kohei Miura
- Department of Rehabilitation Center, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Ayumi Toida
- Department of Central Examination, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Tadamitsu Matsuda
- Department of Physical Therapy, Faculty of Health Science, Juntendo University, 3-2-12, Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Shigeru Makita
- Department of Cardiac Rehabilitation, Saitama Medical University International Medical Center, Hidaka, Saitama, 1397-1 Yamane350-1298, Japan
| |
Collapse
|
13
|
Mechelli F, Arendt‐Nielsen L, Stokes M, Agyapong‐Badu S. Ultrasound imaging for measuring muscle and subcutaneous fat tissue thickness of the anterior thigh: a 2 year longitudinal study in middle age. JCSM CLINICAL REPORTS 2020. [DOI: 10.1002/crt2.7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Affiliation(s)
- Filippo Mechelli
- Centre of Sensory Motor Interaction, Department of Health Science and Technology, School of Medicine University of Aalborg Aalborg Denmark
- Private Practice Urbino Italy
| | - Lars Arendt‐Nielsen
- Centre of Sensory Motor Interaction, Department of Health Science and Technology, School of Medicine University of Aalborg Aalborg Denmark
| | - Maria Stokes
- School of Health Sciences University of Southampton Southampton UK
- Centre for Sport, Exercise and Osteoarthritis Versus Arthritis Nottingham UK
| | - Sandra Agyapong‐Badu
- School of Sport, Exercise and Rehabilitation Sciences University of Birmingham Birmingham UK
| |
Collapse
|
14
|
Kumar R, Shah TH, Hadda V, Tiwari P, Mittal S, Madan K, Khan MA, Mohan A. Assessment of quadriceps muscle thickness using bedside ultrasonography by nurses and physicians in the intensive care unit: Intra- and inter-operator agreement. World J Crit Care Med 2019; 8:127-134. [PMID: 31853448 PMCID: PMC6918044 DOI: 10.5492/wjccm.v8.i7.127] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 08/29/2019] [Accepted: 10/29/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Data regarding the agreement among multiple operators for measurement of quadriceps muscle thickness by bedside ultrasonography (USG) are sparse.
AIM To statistically assess the agreement among 5 operators for measurement of quadriceps muscle thickness on bedside USG.
METHODS This was a cross-sectional observational study. The 5 operators of varied experience (comprised of 1 critical care consultant, 2 fellows, and 2 nurses) independently measured quadriceps muscle thickness in triplicate for 45 critically ill patients each, using USG. Intra- and interrater agreement rates among the 5 operators were assessed using intraclass correlation coefficient (ICC) and expressed with 95% confidence interval (CI).
RESULTS The 5 operators produced a total of 135 readings and 675 observations for ICC calculations to determine the intraoperator and interoperator variations respectively. For intraoperator agreement, the overall ICC (95%CI) was 0.998 (0.997, 0.999) for operator 1, 0.998 (0.997, 0.999) for operator 2, 0.997 (0.995, 0.999) for operator 3, 0.999 (0.998, 0.999) for operator 4, and 0.998 (0.997, 0.999) for operator 5. For interoperator agreement, the overall ICC (95%CI) was 0.977 (0.965, 0.986; P < 0.001) for reading 1, 0.974 (0.960, 0.984; P < 0.001) for reading 2, and 0.975 (0.961, 0.985; P < 0.001) for reading 3.
CONCLUSION USG measurement of quadriceps muscle thickness was not dependent on clinical experience, supporting training for nurses in it.
Collapse
Affiliation(s)
- Rohit Kumar
- Department of Pulmonary, Critical Care and Sleep Medicine, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Tajamul Hussain Shah
- Department of Pulmonary, Critical Care and Sleep Medicine, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Vijay Hadda
- Department of Pulmonary, Critical Care and Sleep Medicine, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Pawan Tiwari
- Department of Pulmonary, Critical Care and Sleep Medicine, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Saurabh Mittal
- Department of Pulmonary, Critical Care and Sleep Medicine, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Karan Madan
- Department of Pulmonary, Critical Care and Sleep Medicine, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Maroof Ahmad Khan
- Department of Biostatistics, All India Institute of Medical Sciences, New Delhi 110029, India
| | - Anant Mohan
- Department of Pulmonary, Critical Care and Sleep Medicine, All India Institute of Medical Sciences, New Delhi 110029, India
| |
Collapse
|
15
|
Weinel LM, Summers MJ, Chapple LA. Ultrasonography to measure quadriceps muscle in critically ill patients: A literature review of reported methodologies. Anaesth Intensive Care 2019; 47:423-434. [DOI: 10.1177/0310057x19875152] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Muscle wasting in the intensive care unit (ICU) is common and may impair functional recovery. Ultrasonography (US) presents a modern solution to quantify skeletal muscle size and monitor muscle wasting. However, no standardised methodology for the conduct of ultrasound-derived quadriceps muscle layer thickness or cross-sectional area in this population exists. The aim of this study was to compare methodologies reported for the measurement of quadriceps muscle layer thickness (MLT) and cross-sectional area (CSA) using US in critically ill patients. Databases PubMed, Ovid, Embase, and CINAHL were searched for original research publications that reported US-derived quadriceps MLT and/or CSA conducted in critically ill adult patients. Data were extracted from eligible studies on parameters relating to US measurement including anatomical location, patient positioning, operator technique and image analysis. It was identified that there was a clear lack of reported detail and substantial differences in the reported methodology used for all parameters. A standardised protocol and minimum reporting standards for US-derived measurement of quadriceps muscle size in ICU is required to allow for consistent measurement techniques and hence interpretation of results.
Collapse
Affiliation(s)
- Luke M Weinel
- Department of Critical Care Services, Royal Adelaide Hospital, Adelaide, Australia
- Discipline of Acute Care Medicine, University of Adelaide, Adelaide, Australia
| | - Matthew J Summers
- Department of Critical Care Services, Royal Adelaide Hospital, Adelaide, Australia
- Discipline of Acute Care Medicine, University of Adelaide, Adelaide, Australia
| | - Lee-Anne Chapple
- Department of Critical Care Services, Royal Adelaide Hospital, Adelaide, Australia
- Discipline of Acute Care Medicine, University of Adelaide, Adelaide, Australia
| |
Collapse
|
16
|
Carvalho MTX, Ludke E, Cardoso DM, Paiva DN, Soares JC, Albuquerque IMD. Efeitos do exercício passivo precoce em cicloergômetro na espessura muscular do quadríceps femoral de pacientes críticos: estudo-piloto randomizado controlado. FISIOTERAPIA E PESQUISA 2019. [DOI: 10.1590/1809-2950/17025126032019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
RESUMO O objetivo deste estudo foi avaliar os efeitos do exercício passivo precoce em cicloergômetro na espessura muscular (EM) do quadríceps femoral (EMQ) de pacientes críticos admitidos em uma Unidade de Terapia Intensiva (UTI) de um hospital universitário terciário. O método utilizado foi um estudo-piloto randomizado controlado conduzido em uma amostra de 24 pacientes (51±18,11 anos, 16 do sexo masculino), com 24 a 48 horas de ventilação mecânica (VM), aleatoriamente divididos em dois grupos: grupo-controle (n=12), que recebeu a fisioterapia convencional; e grupo-intervenção (n=12), que recebeu o exercício passivo em cicloergômetro, uma vez ao dia, durante o período de sete dias do protocolo, em adição à fisioterapia convencional. A EMQ foi mensurada através da ultrassonografia. A primeira medida ultrassonográfica foi realizada entre as primeiras 48 horas de VM e a segunda ao término do protocolo. Não houve diferenças significativas na EMQ esquerda (27,29±5,86mm vs. 25,95±10,89mm; p=0,558) e direita (24,96±5,59mm vs 25,9±9,21mm; p=0,682) do grupo-controle e na EMQ esquerda (27,2±7,38mm vs 29,57±7,89mm; p=0,299) e direita (26,67±8,16mm vs 28,65±8,04mm; p=0,381) do grupo-intervenção. Na comparação entre os grupos, não houve alterações significativas em relação à EMQ esquerda (3,61±1,07mm; p=0,248) e a EMQ direita (2,75±0,85mm; p=0,738). Os resultados deste estudo-piloto demonstraram que a aplicação precoce do exercício passivo em cicloergômetro não promoveu mudanças significativas na espessura da camada muscular avaliada. No entanto, nossos achados sinalizam que a fisioterapia convencional foi capaz de preservar a EMQ de pacientes críticos admitidos em UTI.
Collapse
|
17
|
Validity of Ultrasound Imaging Versus Magnetic Resonance Imaging for Measuring Anterior Thigh Muscle, Subcutaneous Fat, and Fascia Thickness. Methods Protoc 2019; 2:mps2030058. [PMID: 31295936 PMCID: PMC6789827 DOI: 10.3390/mps2030058] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Revised: 06/19/2019] [Accepted: 07/08/2019] [Indexed: 12/14/2022] Open
Abstract
The aim of the present study was to determine the validity of ultrasound (US) imaging versus magnetic resonance imaging (MRI) for measuring anterior thigh muscle, subcutaneous adipose tissue (SAT), and fascia thickness. Twenty healthy, moderately active participants (aged 49.1 ± 9.74 (36–64) years), underwent imaging of the anterior thigh, using ultrasound and MRI modalities on the same day. Images were analyzed offline to assess the level of agreement between US and MRI measurements. Pearson’s correlation coefficient showed an excellent relationship between US imaging and MRI for measuring muscle (r = 0.99, p < 0.01), SAT (r = 0.99, p < 0.01), and non-contractile tissue (SAT combined with perimuscular fascia) thickness (r = 0.99, p < 0.01). Perimuscular fascia thickness measurement showed a poor correlation between modalities (r = 0.39, p < 0.01). Intra-class correlation coefficients (ICC3,1) also showed excellent correlation of the measurements with ICC = 0.99 for muscle thickness, SAT, and non-contractile tissue, but not for perimuscular fascia, which showed poor agreement ICC = 0.36. Bland and Altman plots demonstrated excellent agreement between US imaging and MRI measurements. Criterion validity was demonstrated for US imaging against MRI, for measuring thickness of muscle and SAT, but not perimuscular fascia alone on the anterior thigh. The US imaging technique is therefore applicable for research and clinical purposes for muscle and SAT.
Collapse
|
18
|
Filippo M, Lars AN, Maria S, Sandra AB. Inter-rater and intra-rater reliability of ultrasound imaging for measuring quadriceps muscle and non-contractile tissue thickness of the anterior thigh. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/ab102f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
19
|
|
20
|
Pardo E, El Behi H, Boizeau P, Verdonk F, Alberti C, Lescot T. Reliability of ultrasound measurements of quadriceps muscle thickness in critically ill patients. BMC Anesthesiol 2018; 18:205. [PMID: 30591032 PMCID: PMC6309087 DOI: 10.1186/s12871-018-0647-9] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Accepted: 11/22/2018] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Muscle wasting in critically ill patients is associated with negative clinical outcomes. Ultrasound quadriceps femoris muscle assessment may constitute a convenient tool to evaluate muscle wasting. Nevertheless, its reliability remains uncertain. Our primary aim was to study the intra- and inter-observer reliability of this technique. Our secondary aim was to assess the evolution of the quadriceps muscle during the first 3 weeks after ICU admission and its possible association with nutritional intake. METHODS This observational study included patients expected to stay more than 7 days in the ICU. Ultrasound quadriceps muscle thickness was measured with a 12 MHz linear transducer, by two trained physicians, on D1, D3, D5, D7 and D21. Two measurements sites were evaluated: on the midpoint or on the two-thirds of the length between the anterior superior iliac spine and the upper border of the patella. Intra and inter-observer reliability was assessed by calculating the intra-class correlation coefficient (ICC). RESULTS A total of 280 ultrasound quadriceps thickness measurements were performed on 29 critically ill patients. Intra-observer reliability's ICC was 0.74 [95% CI 0.63; 0.84] at the "midpoint" site and 0.83 [95% CI 0.75; 0.9] at the "two-thirds" site. Inter-observer reliability's ICC was 0.76 [95% CI, 0.66; 0.86] at the "midpoint" site and 0.81 [95% CI, 0.7; 0.9] at the "two-thirds" site. Quadriceps femoris muscle thickness decreased over 16% within the first week after ICU admission. No correlation was found between muscle loss and caloric (p = 0.96) or protein (p = 0.80) debt over the first week. CONCLUSION The assessment by ultrasonography of the quadriceps muscle thickness reveals good intra- and inter-observer reliability and may constitute a promising tool to evaluate the effect of nutritional-based interventions on muscle wasting in critically ill patients. TRIAL REGISTRATION "Committee for the Protection of Human Subjects in Biomedical Research" - Paris Ile de France VI Pitié-Salpêtrière - 10/07/2014. French Data Protection Committee ("Commission Nationale Informatique et Libertés") - #1771144.
Collapse
Affiliation(s)
- Emmanuel Pardo
- Anesthesiology and Critical Care Department, Saint-Antoine Hospital, Assistance publique-hôpitaux de Paris, Paris, France
| | - Hanen El Behi
- Anesthesiology and Critical Care Department, Saint-Antoine Hospital, Assistance publique-hôpitaux de Paris, Paris, France
| | - Priscilla Boizeau
- AP-HP, Inserm, Université de Paris Diderot, Sorbonne Paris Cité, Hôpital Robert Debré, Unité d’épidémiologie clinique, CIC-EC 1426, Paris, France
| | - Franck Verdonk
- Anesthesiology and Critical Care Department, Saint-Antoine Hospital, Assistance publique-hôpitaux de Paris, Paris, France
- Sorbonne Universités, UPMC Université de Paris 06, Paris, France
| | - Corinne Alberti
- AP-HP, Inserm, Université de Paris Diderot, Sorbonne Paris Cité, Hôpital Robert Debré, Unité d’épidémiologie clinique, CIC-EC 1426, Paris, France
| | - Thomas Lescot
- Anesthesiology and Critical Care Department, Saint-Antoine Hospital, Assistance publique-hôpitaux de Paris, Paris, France
- Sorbonne Universités, UPMC Université de Paris 06, Paris, France
| |
Collapse
|
21
|
Hobson-Webb LD, Zwelling PJ, Pifer AN, Killelea CM, Faherty MS, Sell TC, Pastva AM. Point of Care Quantitative Assessment of Muscle Health in Older Individuals: An Investigation of Quantitative Muscle Ultrasound and Electrical Impedance Myography Techniques. Geriatrics (Basel) 2018; 3:geriatrics3040092. [PMID: 31011127 PMCID: PMC6371147 DOI: 10.3390/geriatrics3040092] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/08/2018] [Accepted: 12/13/2018] [Indexed: 12/13/2022] Open
Abstract
Background: Muscle health is recognized for its critical role in the functionality and well-being of older adults. Readily accessible, reliable, and inexpensive methods of measuring muscle health are needed to advance research and clinical care. Methods: In this prospective, blinded study, 27 patients underwent quantitative muscle ultrasound (QMUS), standard electrical impedance myography (sEIM), and handheld electrical impedance myography (hEIM) of the anterior thigh musculature by two independent examiners. Subjects also had dual-energy X-ray absorptiometry (DEXA) scans and standardized tests of physical function and strength. Data were analyzed for intra- and inter-rater reliability, along with correlations with DEXA and physical measures. Results: Measures of intra- and inter-rater reliability were excellent (>0.90) for all QMUS, sEIM, and hEIM parameters except intra-rater reliability of rectus femoris echointensity (0.87–0.89). There were moderate, inverse correlations between QMUS, sEIM, and hEIM parameters and measures of knee extensor strength. Moderate to strong correlations (0.57–0.81) were noted between investigational measures and DEXA-measured fat mass. Conclusions: QMUS, sEIM and hEIM were highly reliable in a controlled, same-day testing protocol. Multiple correlations with measures of strength and body composition were noted for each method. Point-of-care technologies may provide an alternative means of measuring health.
Collapse
Affiliation(s)
- Lisa D Hobson-Webb
- Duke University Department of Neurology/Neuromuscular Division, Durham, NC 27710, USA.
| | - Paul J Zwelling
- Duke University Department of Neurology/Neuromuscular Division, Durham, NC 27710, USA.
| | - Ashley N Pifer
- Duke University Department of Neurology/Neuromuscular Division, Durham, NC 27710, USA.
| | - Carrie M Killelea
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Michael W. Krzyzewski Human Performance Laboratory, Durham, NC 27710, USA.
| | - Mallory S Faherty
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Michael W. Krzyzewski Human Performance Laboratory, Durham, NC 27710, USA.
| | - Timothy C Sell
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Michael W. Krzyzewski Human Performance Laboratory, Durham, NC 27710, USA.
| | - Amy M Pastva
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Duke University Claude D. Pepper Older American Independence Center Durham, NC 27710, USA.
| |
Collapse
|
22
|
Hadda V, Kumar R, Khilnani GC, Kalaivani M, Madan K, Tiwari P, Mittal S, Mohan A, Bhalla AS, Guleria R. Trends of loss of peripheral muscle thickness on ultrasonography and its relationship with outcomes among patients with sepsis. J Intensive Care 2018; 6:81. [PMID: 30564367 PMCID: PMC6292013 DOI: 10.1186/s40560-018-0350-4] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 11/23/2018] [Indexed: 02/06/2023] Open
Abstract
Background and aims Data regarding trends of muscle loss on ultrasonography (USG) and its relationship with various outcomes among critically ill patients is limited. This study aimed to describe the trends of loss of muscle thickness of the arm and thigh (assessed using USG) and to determine the relationship between loss of muscle thickness and in-hospital and post-discharge outcomes. Methods Muscle thickness of 70 patients with sepsis was measured at the level of the mid-arm and mid-thigh using bedside USG on days 1, 3, 5, 7, 10 and 14 and then weekly till discharge or death. Patients were followed up for 90 days after discharge. Results The muscle thickness (mean ± SD) at the level of the mid-arm and mid-thigh on day 1 was 23.13 ± 4.83 mm and 31.21 ± 8.56 mm, respectively. The percentage muscle thickness [median (min, max)] decline at the mid-arm and mid-thigh was 7.61 (- 1.51, 32.05)% and 10.62 (- 1.48, 32.06)%, respectively on day 7 as compared to baseline (p < 0.001). The decline in muscle thickness at the mid-arm and mid-thigh were higher among non-survivors compared to survivors at all time points. Also, the decline in muscle thickness was significantly higher among patients with worse outcome at day 90. Patients with ICU-acquired weakness also had significantly higher decline in muscle thickness (p < 0.05). Early decline (from day 1 to day 3) in muscle thickness was associated with in-hospital mortality. The probability of death by day 14 was higher for patients who had early decline (from day 1 to day 3) in muscle thickness of ≥ 6.59% and ≥ 5.20% at the mid-arm [HR 7.3 (95% CI 1.5, 34.2)] and the mid-thigh [HR 8.1 (95% CI 1.7, 37.9)], respectively. Decline in thickness from day 1 to day 3 was a good predictor of in-hospital mortality with area under the curve (AUC) of 0.81 and 0.86 for arm and thigh muscles, respectively. Conclusions Critically ill patients with sepsis exhibit a gradual decline in muscle thickness of both the arm and thigh. Decline in muscle thickness was associated with in-hospital mortality. USG has a potential to identify patients at risk of worse in-hospital and post-discharge outcomes.
Collapse
Affiliation(s)
- Vijay Hadda
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Rohit Kumar
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Gopi Chand Khilnani
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Mani Kalaivani
- 2Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, India
| | - Karan Madan
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Pawan Tiwari
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Saurabh Mittal
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Anant Mohan
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Ashu Seith Bhalla
- 3Department of Radio-diagnosis, All India Institute of Medical Sciences, New Delhi, India
| | - Randeep Guleria
- 1Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
23
|
Hadda V, Kumar R, Hussain T, Khan MA, Madan K, Mohan A, Khilnani GC, Guleria R. Reliability of ultrasonographic arm muscle thickness measurement by various levels of health care providers in ICU. Clin Nutr ESPEN 2018; 24:78-81. [PMID: 29576368 DOI: 10.1016/j.clnesp.2018.01.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 12/18/2017] [Accepted: 01/17/2018] [Indexed: 01/05/2023]
Abstract
PURPOSE Reliability of arm muscle thickness measurement using ultrasonography (USG) by operators of varied experience is unknown. Hence, we planned this study to determine the reliability of arm muscle thickness measured using USG by 5 observers with variable experience. MATERIALS AND METHOD This was a cross-sectional observational study which included critically ill patients with sepsis. Arm muscle thickness was measured in triplicate on Siemens ACUSON X300™ USG machine by each of 5 observers. Intra-class correlation coefficient (ICC) was computed to assess intra-observer and inter-observer variability of multiple observations. RESULTS This study included 45 (30 - male) patients. Mean (±SD) age, APACHE and SAPS score of the participants were 54.95 (±15.97) years, 14.66 (±4.57) and 2.6 (±1.37), respectively. There were 135 observations by each observer. ICC (95%CI) for intra-observer reliability study for observer 1, 2, 3, 4, and 5 were 0.997 (0.995-0.998), 0.996 (0.993-0.998), 0.997 (0.996-0.998), 0.997 (0.994-0.998) and 0.998 (0.986-0.999), respectively. ICC (95%CI) for inter-observer reliability study for 1st, 2nd and 3rd reading were 0.963 (0.943-0.977), 0.992 (0.988-0.995) and 0.992 (0.988-0.995), respectively. CONCLUSIONS There was an excellent intra- and inter-observer agreement among 5 observers for measurement of arm muscle thickness using bedside USG among patients with sepsis.
Collapse
Affiliation(s)
- Vijay Hadda
- Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India.
| | - Rohit Kumar
- Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Tajamul Hussain
- Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Maroof Ahmad Khan
- Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, India
| | - Karan Madan
- Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Anant Mohan
- Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Gopi C Khilnani
- Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Randeep Guleria
- Department of Pulmonary Medicine and Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|