1
|
Favaloro EJ, Mohammed S, Vong R, Chapman K, Kershaw G, Just S, Connelly L, Ryan M, Zebeljan D, Brighton T, Pasalic L. Harmonizing platelet function analyzer testing and reporting in a large laboratory network. Int J Lab Hematol 2022; 44:934-944. [PMID: 35754202 PMCID: PMC9545980 DOI: 10.1111/ijlh.13907] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 05/30/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The platelet function analyzer (PFA) is a popular platelet function screening instrument, highly sensitive to von Willebrand disease (VWD) and to aspirin therapy, with moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. There are two models, the original PFA-100 and the contemporary PFA-200. Normal reference ranges (NRRs) provided by the manufacturer are the same for both models, instead being based on the type of test cartridge, for which there are two main ones: collagen/epinephrine (C/Epi) and collagen/adenosine diphosphate (C/ADP). METHODS Comparative evaluations of PFA testing and reporting in six different sites of a large pathology network, aiming to harmonize NRRs and test reporting across all network sites. A separate comparative study of testing a range of samples (n > 150) on a PFA-100 versus that on a PFA-200. Review of contemporary literature. RESULTS Each site was identified to have a different reporting NRR, which after consolidating data permitted establishment of an agreed harmonized NRR for use across the network (C/Epi: 90-160; C/ADP: 70-124; based on n > 180). Similarly, each site reported and interpreted results in different ways, and after discussion and consolidation, a harmonized approach to interpretation and reporting was achieved. The separate comparative study of PFA-100 versus PFA-200 testing confirmed instrument equivalence. CONCLUSION We achieved harmonized NRRs and reporting for PFA testing across a large pathology network. Our approach may be useful for other laboratory networks wishing to harmonize PFA testing.
Collapse
Affiliation(s)
- Emmanuel J Favaloro
- Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, New South Wales, Australia.,Sydney Centres for Thrombosis and Haemostasis, Westmead, New South Wales, Australia.,Faculty of Science and Health, Charles Sturt University, Wagga Wagga, New South Wales, Australia
| | - Soma Mohammed
- Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, New South Wales, Australia
| | - Ronny Vong
- Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, New South Wales, Australia
| | - Kent Chapman
- Haematology, NSW Health Pathology, John Hunter Hospital, Newcastle, New South Wales, Australia
| | - Geoffrey Kershaw
- Haematology, NSW Health Pathology, Prince Alfred Hospital, Camperdown, New South Wales, Australia
| | - Sarah Just
- Haematology, NSW Health Pathology, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| | - Lynne Connelly
- Haematology, NSW Health Pathology, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| | - Michael Ryan
- Haematology, NSW Health Pathology, Wollongong Hospital, Wollongong, New South Wales, Australia
| | - Diane Zebeljan
- Haematology, NSW Health Pathology, Liverpool Hospital, Liverpool, New South Wales, Australia
| | - Timothy Brighton
- Haematology, NSW Health Pathology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Leonardo Pasalic
- Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, New South Wales, Australia.,Sydney Centres for Thrombosis and Haemostasis, Westmead, New South Wales, Australia.,Westmead Clinical School, University of Sydney, Westmead, New South Wales, Australia
| |
Collapse
|