Ghazy ES, Altonbary GY, Gebreel A, El-Daker MA, Hegazy SA. Evaluation and comparison of retention and patient satisfaction with milled polyetheretherketone versus metal maxillary obturators.
J Prosthet Dent 2023:S0022-3913(23)00547-4. [PMID:
37838571 DOI:
10.1016/j.prosdent.2023.07.037]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 07/26/2023] [Accepted: 07/27/2023] [Indexed: 10/16/2023]
Abstract
STATEMENT OF PROBLEM
Metal and polyetheretherketone (PEEK) have been used to rehabilitate maxillary defects with obturators, each having advantages and disadvantages. However, patient satisfaction with the obturator retention of each material is unclear.
PURPOSE
The purpose of this crossover clinical study was to compare retention and patient satisfaction between a milled cobalt chromium and a milled PEEK framework, each with a hollow bulb extension in polymethyl methacrylate (PMMA).
MATERIAL AND METHODS
Twenty patients who had received unilateral total maxillectomy and were treated in the prosthodontic department's maxillofacial clinic were enrolled in this crossover study. Each participant wore 2 different types of obturators for 6 months after insertion. Type CoCr received a milled cobalt chromium framework with a hollow bulb extension in PMMA first, and type Pk received a milled modified PEEK (BioHPP) framework with a hollow bulb extension in PMMA first. Patient satisfaction and retention force were measured immediately, at 3 months, and at 6 months after obturator insertions. The Fischer exact, chi-squared, and Monte Carlo tests were used to compare qualitative data. One-way ANOVA with the post hoc Tukey test was used for pair-wise comparison, and repeated measures ANOVA was used to compare before and after treatment at 3 and 6 months.
RESULTS
No significant difference was found between types in obturator insertion (P>.999), appearance of the upper lip (P>.999), mouth feeling (P=.301), pronunciation of words (P=.217), and talking in public (P=.589). A significant difference between types was found in speech after 6 months of obturator insertion (P=.016), swallowing liquids and food (P=.04), masticating foods (P=.007), appearance of clasps on anterior teeth (P=.002), satisfaction with appearance (P=.005), or avoidance of family events (P=.014) after 6 months of insertion. Types of obturators showed a statistically significant decrease in retention force with time (P<.001).
CONCLUSIONS
Although the retention force was less with PEEK than with Co-Cr clasps engaging the same undercuts, this retention force was adequate for retaining removable partial dentures. Co-Cr clasps can be considered better than PEEK clasps because they engage the same undercuts regarding loss of retention with time. Quality of life in patients after maxillary resection could be improved by using maxillary obturators. Type Pk was better than type CoCr in terms of esthetics, but the retention of the PEEK obturator after 6 months decreased because of wear, leading to difficulty swallowing food or liquids, mastication, and speech.
Collapse