1
|
Nakano H, Kawahara D, Tanabe S, Utsunomiya S, Takizawa T, Sakai M, Nakano T, Ohta A, Kaidu M, Ishikawa H. Calculated relative biological effectiveness (RBE) for initial DNA double-strand breaks (DSB) from flattening filter and flattening filter-free 6 MV X-ray fields. BJR Open 2021; 3:20200072. [PMID: 34286177 PMCID: PMC8256801 DOI: 10.1259/bjro.20200072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/25/2021] [Indexed: 12/14/2022] Open
Abstract
Objectives We evaluated the radiobiological effectiveness based on the yields of DNA double-strand breaks (DSBs) of field induction with flattening filter (FF) and FF-free (FFF) photon beams. Methods We used the particle and heavy ion transport system (PHITS) and a water equivalent phantom (30 × 30 × 30 cm3) to calculate the physical qualities of the dose-mean lineal energy (yD) with 6 MV FF and FFF. The relative biological effectiveness based on the yields of DNA-DSBs (RBEDSB) was calculated for standard radiation such as 220 kVp X-rays by using the estimating yields of SSBs and DSBs. The measurement points used to calculate the in-field yD and RBEDSB were located at a depth of 3, 5, and 10 cm in the water equivalent phantom on the central axis. Measurement points at 6, 8, and 10 cm in the lateral direction of each of the three depths from the central axis were set to calculate the out-of-field yD and RBEDSB. Results The RBEDSB of FFF in-field was 1.7% higher than FF at each measurement depth. The RBEDSB of FFF out-of-field was 1.9 to 6.4% higher than FF at each depth measurement point. As the distance to out-of-field increased, the RBEDSB of FFF rose higher than those of FF. FFF has a larger RBEDSB than FF based on the yields of DNA-DSBs as the distance to out-of-field increased. Conclusions The out-of-field radiobiological effect of FFF could thus be greater than that of FF since the spreading of the radiation dose out-of-field with FFF could be a concern compared to the FF. Advances in knowledge The RBEDSB of FFF of out-of-field might be larger than FF.
Collapse
Affiliation(s)
- Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Daisuke Kawahara
- Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima-shi, Hiroshima, Japan
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | | | - Madoka Sakai
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Toshimichi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Atsushi Ohta
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Motoki Kaidu
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, Niigata, 3057 Yamada, Nishi-ku, Niigata, Japan
| | - Hiroyuki Ishikawa
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, Niigata, 3057 Yamada, Nishi-ku, Niigata, Japan
| |
Collapse
|
2
|
Mishra B, Mishra S, Selvam TP, Chavan ST, Pethe SN. Comparison of Measured and Monte Carlo Calculated Dose Distributions from Indigenously Developed 6 MV Flattening Filter Free Medical Linear Accelerator. J Med Phys 2018; 43:162-167. [PMID: 30305773 PMCID: PMC6172861 DOI: 10.4103/jmp.jmp_58_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Purpose: Monte Carlo simulation was carried out for a 6 MV flattening filter-free (FFF) indigenously developed linear accelerator (linac) using the BEAMnrc user-code of the EGSnrc code system. The model was benchmarked against the measurements. A Gaussian distributed electron beam of kinetic energy 6.2 MeV with full-width half maximum of 1 mm was used in this study. Methods: The simulation of indigenously developed linac unit has been carried out by using the Monte Carlo-based BEAMnrc user-code of the EGSnrc code system. Using the simulated model, depth and lateral dose profiles were studied using the DOSXYZnrc user-code. The calculated dose data were compared against the measurements using an RFA dosimertic system made by PTW, Germany (water tank MP3-M and 0.125 cm3 ion chamber). Results: The BEAMDP code was used to analyze photon fluence spectra, mean energy distribution, and electron contamination fluence spectra. Percentage depth dose (PDD) and beam profiles (along both X and Y directions) were calculated for the field sizes 5 cm × 5 cm - 25 cm × 25 cm. The dose difference between the calculated and measured PDD and profile values were under 1%, except for the penumbra region where the maximum deviation was found to be around 3%. Conclusions: A Monte Carlo model of indigenous FFF linac (6 MV) has been developed and benchmarked against the measured data.
Collapse
Affiliation(s)
- Bibekananda Mishra
- Radiological Safety Division, Atomic Energy Regulatory Board, Mumbai, Maharashtra, India.,Homi Bhabha National Institute, Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India
| | - Subhalaxmi Mishra
- Homi Bhabha National Institute, Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.,Radiological Physics and Advisory Division, Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India
| | - T Palani Selvam
- Homi Bhabha National Institute, Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.,Radiological Physics and Advisory Division, Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India
| | - S T Chavan
- Medical Electronics Division-1, Society for Applied Microwave Electronics Engineering and Research, Mumbai, Maharashtra, India
| | - S N Pethe
- Medical Electronics Division-1, Society for Applied Microwave Electronics Engineering and Research, Mumbai, Maharashtra, India
| |
Collapse
|