1
|
Lee KH, Hung YT, Chang CY, Wang JC, Tsai SW, Chen CF, Wu PK, Chen WM. The cementless taper wedge vs. fit-and-fill stem in primary total hip arthroplasty: risk of stem-related complication differs across Dorr types. Arch Orthop Trauma Surg 2024; 144:2839-2847. [PMID: 38739153 DOI: 10.1007/s00402-024-05361-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Accepted: 05/02/2024] [Indexed: 05/14/2024]
Abstract
INTRODUCTION The choice between a cementless taper wedge stem and a fit-and-fill stem in total Hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly evaluated. This study aimed to compare the risk of stem-related complications between these two stem types in Dorr type A, B, and C femurs. MATERIALS AND METHODS From January 2015 through April 2021, we retrospectively reviewed 1995 cementless THA procedures. We stratified all procedures into three groups: Dorr type A (N = 360, 18.0%), B (N = 1489, 74.7%) and C (N = 146, 7.3%). The primary outcome domain was stem-related complications, including stem subsidence ≥ 3 mm, intraoperative fracture, periprosthetic fracture and aseptic stem loosening. We performed multivariate regression analysis to compare the risk of stem-related complication between the two stem types. Other factors included age, sex, body mass index, diagnosis, age-adjusted Charlson comorbidity index, stem alignment and canal fill ratio. RESULTS The incidence of stem-related complications in the taper wedge and fit-and-fill stem groups was 4.4% (N = 15) and 6.5% (N = 107), respectively. Fit-and-fill stems showed an increased risk of stem-related complications (aOR: 9.903, 95% CI: 1.567-62.597) only in Dorr type C femurs. No significant difference in risk was observed in Dorr type A and B femurs. Furthermore, the canal fill ratio at the lesser trochanter, 2 cm and 7 cm below the lesser trochanter, did not exhibit an association with stem-related complications in any Dorr type. CONCLUSIONS Concerning the risk of stem-related complications, the taper wedge stem was a better choice in Dorr type C femurs. However, there was no difference in risk between the taper wedge stem and fit-and-fill stem in Dorr type A and B femurs.
Collapse
Affiliation(s)
- Kun-Han Lee
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Yueh-Ting Hung
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Cheng-Yang Chang
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Jui-Chien Wang
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Shang-Wen Tsai
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan.
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
| | - Cheng-Fong Chen
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Po-Kuei Wu
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Wei-Ming Chen
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| |
Collapse
|
2
|
Lee CY, Jin SY, Choi JH, Yoon TR, Park KS. Comparison of Short Curved Stems and Standard-length Single Wedged Stems for Cementless Total Hip Arthroplasty. Hip Pelvis 2024; 36:120-128. [PMID: 38825821 PMCID: PMC11162871 DOI: 10.5371/hp.2024.36.2.120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 10/29/2023] [Accepted: 10/30/2023] [Indexed: 06/04/2024] Open
Abstract
Purpose The purpose of this study was to compare the clinical and radiographic outcomes with use of short-curved stems versus standard-length single wedged stems over a minimum follow-up period of five years. Materials and Methods A retrospective study of primary total hip arthroplasties performed using the Fitmore® stem (127 hips, 122 patients) and the M/L taper® stem (195 hips, 187 patients) between October 2012 and June 2014 was conducted. The clinical and radiographic outcomes were obtained for evaluation over a minimum follow-up period of five years. Results In both the Fitmore® and M/L taper® groups, the mean Harris hip score improved from 52.4 and 48.9 preoperatively to 93.3 and 94.5 at the final follow-up, respectively (P=0.980). The mean Western Ontario and McMaster Universities Osteoarthritis Index scores also improved from 73.3 and 76.8 preoperatively to 22.9 and 25.6 at the final follow-up, respectively (P=0.465). Fifteen hips (Fitmore®: 14 hips; M/L taper®: one hip, P<0.001) developed intraoperative cracks and were treated simultaneously with cerclage wiring. Radiography showed a radiolucent line in 24 hips in the Fitmore® group and 12 hips in the M/L taper® group (P=0.125). Cortical hypertrophy was detected in 29 hips (Fitmore® group: 28 hips; M/L taper® group: one hip, P<0.001). Conclusion Similarly favorable clinical and radiographic outcomes were achieved with use of both short-curved stems and standard-length single wedged stems. However, higher cortical hypertrophy and a higher rate of femoral crack were observed with use of Fitmore® stems.
Collapse
Affiliation(s)
- Chan Young Lee
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hwasun Hospital, Hwasun, Korea
| | - Sheng-Yu Jin
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hwasun Hospital, Hwasun, Korea
| | - Ji Hoon Choi
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hwasun Hospital, Hwasun, Korea
| | - Taek-Rim Yoon
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hwasun Hospital, Hwasun, Korea
| | - Kyung-Soon Park
- Department of Orthopedic Surgery, Chonnam National University Medical School and Hwasun Hospital, Hwasun, Korea
| |
Collapse
|
3
|
Li M, Zeng Y, Nie Y, Liao K, Pei F, Yang J, Xie H, Shen B. A high risk of postoperative periprosthetic femoral fracture in Dorr type C femurs: a retrospective cohort study with 10-year follow-up data and a preliminary monochromatic image analysis. Int J Surg 2024; 110:296-305. [PMID: 37830949 PMCID: PMC10793812 DOI: 10.1097/js9.0000000000000810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 09/18/2023] [Indexed: 10/14/2023]
Abstract
BACKGROUND The authors applied Anatomique Benoist Girard II (ABG II) stems for total hip arthroplasty in some Dorr type C femurs as early attempts. Here, the authors compared the long-term follow-up results between ABG II stems and the 'well-performing' Corail stems and their monochromatic images. METHODS Among 3214 primary total hip arthroplasty records, 43 short ABG II stems and 67 standard-length Corail stems implanted in Dorr type C femurs were eligible and enrolled in this retrospective cohort study, with a mean follow-up of 10.3 years. Revision rates, Harris hip scores, and radiologic signs were compared. Spectral CT scans from a representative sample were obtained, and monochromatic images were reconstructed. A quantitative method was developed to measure the volume of the gap around stems. Patient-specific finite element analysis was conducted to investigate the strains. RESULTS The revision rate of ABG II stems was significantly higher than that of Corail stems (21 vs. 3%, P <0.05). In the monochromatic images, fewer spot-weld signs (2.2 vs. 3.4, P <0.05) and wider gaps around stems (1.64 cm 3 vs. 0.13 cm 3 , P <0.05) were observed on average in the ABG II group. The mean maximum principal strains of the proximal femurs in the ABG II group were close to the yield strains and significantly larger than those in the Corail group (0.0052 vs. 0.0011, P <0.05). CONCLUSIONS There was a high risk of postoperative periprosthetic femoral fracture for ABG II stems in Dorr type C femurs. Monochromatic images provided some insight into the failure mechanism. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Mingyang Li
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital
| | - Yi Zeng
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital
| | - Yong Nie
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital
| | - Kai Liao
- Department of Radiology, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan Province, People’s Republic of China
| | - Fuxing Pei
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital
| | - Jing Yang
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital
| | - Huiqi Xie
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital
| | - Bin Shen
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital
| |
Collapse
|
4
|
Kinoshita S, Kinoshita K, Sakamoto T, Seo H, Suzuki M, Yamamoto T. Sequential Intraoperative Evaluation of Rotational Stability of Cementless Stem in Total Hip Arthroplasty: A Broach-Based Study. J Clin Med 2023; 12:5444. [PMID: 37685511 PMCID: PMC10487492 DOI: 10.3390/jcm12175444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/05/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023] Open
Abstract
In cementless total hip arthroplasty, the rotational stability of the stem is generally confirmed in a one-time manual evaluation by the surgeon. This study was performed to evaluate the sequential intraoperative changes in rotational stability using a torque wrench. Primary total hip arthroplasty was performed on 52 consecutive hips using a single wedge stem design. Intraoperative evaluation of rotational stability was uniformly performed using a torque wrench. Evaluations were performed immediately after broach insertion and immediately before the final insertion of the stem (after placement of the acetabular cup). Immediately after the insertion of the broach, rotational stability was checked and confirmed to be fully stabilized using a torque wrench in all cases, and the stability was maintained in 17 of 52 (33%) hips immediately before the final insertion of the stem. Among the hips showing instability, 11 of 35 (31%) broaches were upsized, while the remaining 24 hips achieved stabilization through deeper insertion of the broach. In conclusion, the rotational stability achieved immediately after the insertion of the broach was not necessarily maintained during surgery, indicating that rotational stability may need to be checked at multiple time points intraoperatively.
Collapse
Affiliation(s)
| | | | | | | | | | - Takuaki Yamamoto
- Department of Orthopaedic Surgery, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan; (S.K.); (K.K.); (T.S.); (H.S.); (M.S.)
| |
Collapse
|
5
|
Ferreño Márquez DM, Dauder Gallego C, Bebea Zamorano FNG, Sebastián Pérez V, Montejo Sancho J, Martínez Martín J. Long-Term Outcomes of 496 Anatomical Cementless Modular Femoral Stems: Eleven to Twenty Years of Follow-Up. J Arthroplasty 2021; 36:2087-2099. [PMID: 33610406 DOI: 10.1016/j.arth.2021.01.057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 01/16/2021] [Accepted: 01/19/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The aim of the study is to assess the long-term outcomes of this specific stem (anatomical cementless modular stem ESOP), to review the survivorship, complication rate, and radiographic and clinical outcomes. METHODS Descriptive and analytical retrospective longitudinal observational study of patients was operated on total hip arthroplasty between 1998 and 2007. Four hundred ninety-six prostheses corresponding to 447 patients were reviewed, mean age was 65.8 years (standard deviation [SD] ±11.6 years), and median follow-up time was 13.4 years (range 1-20). The most used cups were cementless (75.8%). The most frequent friction pairs were metal-polyethylene (53.1%) and ceramic-polyethylene (24.2%). Main variables analyzed were stem survival, subsidence, coronal orientation, osteolysis, reintervention, and Oxford Hip Score. RESULTS From 496 implants, there were 22 lost to follow-up (4.4%). Stem revision was performed in 51 patients: 26 periprosthetic joint infections (2-stage revision), 16 periprosthetic fractures, and 8 one-stage revisions (6 real aseptic loosening with negative culture after revision). The stem survivorship at more than 15 years for any reason was 89.2% and for aseptic loosening 97.97%. No specific complications were found due to modularity. The mean subsidence and orientation was 2.06 mm (SD ±5.11 mm) and 0.41° varus (SD ±2.20°) respectively. Subsidence >5 mm or varus >5° was associated with a higher revision rate. Osteolysis was found in 110 patients (zone I = 79, VII = 57), associated with zirconium-polyethylene, without relationship to the stem revision rate or Oxford Hip Score. CONCLUSION To our knowledge, this study represents the largest series of this stem, revealing an excellent survival rate and long-term clinical outcomes similar to the best results of classical cementless stems published in the literature.
Collapse
Affiliation(s)
| | | | | | | | - Jorge Montejo Sancho
- Department of Orthopaedic Surgery, Hospital Universitario Fundación Alcorcón, Madrid, Spain
| | - Javier Martínez Martín
- Department of Orthopaedic Surgery, Hospital Universitario Fundación Alcorcón, Madrid, Spain
| |
Collapse
|
6
|
Alsaleem MK, Alalwan HA, Alkhars AM, Al Huwaiyshil AH, Alamri WM. Intraoperative Periprosthetic Fractures in Total Hip Arthroplasty in Patients With Sickle Cell Disease at King Fahad Hospital Hofuf: A Cross-Sectional Study. Cureus 2020; 12:e11390. [PMID: 33312790 PMCID: PMC7725205 DOI: 10.7759/cureus.11390] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Background Patients with avascular necrosis related to sickle cell disease (SCD) can be severely disabled by the severe degenerative changes of their hip. Total hip arthroplasty (THA) remains the only surgical option for some of these patients. Total hip arthroplasty can be a challenging procedure, and SCD patients demonstrate high percentages of medical, intraoperative, and postoperative complications and implant failure. Furthermore, the need for THA following avascular necrosis in the Eastern Province of Saudi Arabia is high, and the subsequent risk of periprosthetic fracture is prevalent. Therefore, it is crucial to conduct such a study. Aim of the study This cross-sectional retrospective study aimed to assess the prevalence and associated risk factors for periprosthetic fractures during total hip arthroplasty in sickle cell disease patients at King Fahad Hospital Hofuf, Saudi Arabia. Methods We collected the data of all SCD patients who had undergone THA during the study period, January 2015 to September 2020. Forty-nine SCD patients who had undergone THA during the study period were included. Patients who had undergone hip hemiarthroplasty, postoperative fractures, or had an indication of THA other than avascular necrosis were excluded. Surgeon factors, assistant factors, and surgical technique were also excluded. We then analyzed the data according to gender, age, BMI, American Society of Anesthesiologists classification, implant fixation type, avascular necrosis stage, proximal femoral morphology, Vancouver classification type, sickle cell type, preoperative hemoglobin (Hb) level, and the risk of periprosthetic fractures. Descriptive statistics were presented using frequency and percentages for categorical variables, and continuous variables were summarized using means ± standard deviations. Independent t-tests and chi-square tests were used to test for associations between categorical variables. At 0.05, the significance level was set. Results Of the patients, 32.7% were male and 67.3% were female. 32.7% of the patients had advanced degenerative changes due to avascular necrosis. Among the patients, 20.4% had an intraoperative periprosthetic femoral fracture, 90% had a Vancouver classification class A, and 10% had a Vancouver classification class B1. According to Dorr classification, 75.5% were classified as Dorr A and 24.5% as Dorr B. Of the patients, 48 had an uncemented implant, and only 1 had cemented. The mean perioperative Hb was 9.02 + 2.02, with a minimum of 6 and a maximum of 14. No significant associations were found between the incidence of intraoperative femoral fracture and the demographic variables and the operative profile characteristics. However, a significantly higher rate of fracture was observed in patients operated on the right side compared to patients operated on the left side. Conclusion The prevalence of periprosthetic intraoperative fracture among SCD patients at King Fahad Hospital Hofuf was 20.4% during the study period. Even with adequate perioperative management, orthopedic surgeons must be prepared to deal with high rates of intraoperative fracture. No significant association was found between the incidence of intraoperative femoral fracture in SCD patients and the demographic variables and the operative profiles. However, a significantly higher rate of fracture was observed in patients operated on the right side compared to patients operated on the left side.
Collapse
|
7
|
Kim JT, Kim HS, Lee YK, Ha YC, Koo KH. Total Hip Arthroplasty With Trochanteric Ostectomy for Patients With Angular Deformity of the Proximal Femur. J Arthroplasty 2020; 35:2911-2918. [PMID: 32473769 DOI: 10.1016/j.arth.2020.04.099] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 04/28/2020] [Accepted: 04/30/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) of patients with a proximal femoral deformity is technically demanding. This deformity poses the risk of femoral fracture or perforation; stem malposition; and failed stem fixation. To insert a femoral stem in neutral position with a good fit, we removed the greater trochanter in case of a varus deformity, and the lesser trochanter in case of valgus deformity, while performing THA. We aimed to evaluate stem position, implant stability, clinical results, and radiological changes after THAs using this technique. METHODS Fifteen patients (17 hips; 11 varus hips and 6 valgus hips) underwent cementless THA using the trochanteric osteotomy technique in one institution. We evaluated procedure-specific complications: intraoperative femoral fracture, stem malposition, weakness of the abductor power and limp. Modified Harris Hip Score, radiological changes, and the stability of stems were assessed at a mean of 7.1 years of follow-up (range 2.0-15.5). RESULTS Femoral fracture occurred during the insertion of the stem in 4 hips. All stems were aligned in neutral position. At the latest follow-up, the mean power of the abductor was 4.3 (range 3-5). Eleven patients had slight limp and 4 patients had moderate limp. All stems had bone-ingrown stability and no stem was revised. The mean modified Harris Hip Score improved from 50 points at the preoperative evaluation to 81 points at the final follow-up. CONCLUSION The trochanteric excision enabled neutral insertion of cementless stem in patients with varus/valgus deformity of the proximal femur, and THA using this technique rendered favorable results.
Collapse
Affiliation(s)
- Jung-Taek Kim
- Department of Orthopedic Surgery, Ajou University School of Medicine, Ajou University Medical Center, Suwon, South Korea
| | - Hong Seok Kim
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea; Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| |
Collapse
|