1
|
Ficke JB, Watson NL, Stocker DJ, Schlegel KE, Sahajwalla MC, Adams CC. Simulated Fewer-Angle SPECT/CT Imaging Protocol for Parathyroid Adenoma. J Nucl Med Technol 2024; 52:132-136. [PMID: 37963782 PMCID: PMC11149588 DOI: 10.2967/jnmt.122.264649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 10/04/2023] [Indexed: 11/16/2023] Open
Abstract
A new SPECT/CT protocol for parathyroid imaging detailing fewer image-angle acquisitions (fewer-angle SPECT/CT [FASpecT/CT]) was evaluated for identification of parathyroid adenoma. The motivation for validating this protocol was to be able to use it in the future to decrease patient imaging time in our clinic. Methods: This was a retrospective review of existing data performed as a simulated case control study evaluating 50 parathyroid SPECT/CT scans acquired using the standard 60-stop protocol and the tested 15-stop FASpecT protocol acquired using angular sampling software. Agreement on the final interpretations between imaging methods was evaluated using the McNemar test and the Cohen κ. Interrater reliability among the 3 readers was described for each method using the Fleiss κ interpreted as in the strength-of-agreement guidelines by Landis and Koch. Results: Of the 50 evaluated images, 45 (90%) had concordant final image interpretations between imaging methods. The sensitivity of FASpecT/CT relative to SPECT/CT was 17 of 19 (89.5%; 95% CI, 66.9%-98.7%), and the specificity was 28 of 31 (90.3%; 95% CI, 74.2%-98.0%). Additionally, there was statistically significant substantial agreement between protocols and among readers for each protocol. Conclusion: Adequate diagnostic-quality SPECT/CT images can be acquired using significantly fewer imaging stops given advances in camera quality and processing algorithms such as iterative reconstruction.
Collapse
Affiliation(s)
- Jennifer B Ficke
- Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland;
| | - Nora L Watson
- Department of Research Programs, Walter Reed National Military Medical Center, Bethesda, Maryland; and
| | - Derek J Stocker
- Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland
| | - Kevin E Schlegel
- Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland
| | - Maya C Sahajwalla
- Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland
| | - Chad C Adams
- Department of Radiology, Eisenhower Army Medical Center, Augusta, Georgia
| |
Collapse
|
2
|
Rep S, Jensterle L, Zdešar U, Zaletel K, Tomše P, Ležaič L. Contribution of CT scan to patient's radiation exposure in parathyroid SPECT/CT scintigraphy. Radiography (Lond) 2024; 30:995-1000. [PMID: 38688163 DOI: 10.1016/j.radi.2024.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 04/11/2024] [Accepted: 04/11/2024] [Indexed: 05/02/2024]
Abstract
INTRODUCTION Dual phase technetium-99mTc-methoxy isobutyl isonitrile (MIBI) single-photon emission computed tomography with computed tomography (SPECT/CT) may be the most accurate conventional imaging approach for localization of enlarged parathyroid gland (EPG). The imaging is based on the radiopharmaceutical (RP) retention in EPG compared to washout from normal thyroid and normal parathyroid glands. This study aimed to estimate and optimize the contribution of computed tomography (CT) scan and scan range to effective dose (ED) in dual-phase MIBI SPECT/CT parathyroid scintigraphy. METHODS The study included seventy-four patients; thirty-seven with reduced and thirty-seven with extended CT scan range. The ED caused by the CT scan was calculated using Dose Length Product (DLP) data and estimated using the Imaging Performance Assessment of CT scanners (ImPACT) calculator. RESULTS For all patients, the contribution of CT to the ED in a combined SPECT/CT examination was 2.62 ± 0.29 mSv (48%). The contribution of CT to the total ED was 1.8 ± 0.18 mSv (33%) when using reduced and 3.44 ± 0.23 mSv (64%) when using extended scan range. The DLP and ED were statistically significantly different between the reduced and extended CT scan range (p < 0.001) in the first and second phases. The individual organ dose was reduced from 8% to 94%. CONCLUSION The hybrid SPECT/CT improves the interpretation of nuclear medicine images and also increases the radiation dose to the patient. An adequately defined CT scan range on SPECT/CT imaging, can significantly reduce a patient's ED. IMPLICATIONS FOR PRACTICE The research findings showed that knowledge of anatomy, pathology and technology can provide optimising diagnostic procedures and reduce patient ED after SPECT/CT scans.
Collapse
Affiliation(s)
- S Rep
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia; University of Ljubljana, Faculty of Health Sciences, Slovenia.
| | - L Jensterle
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia
| | - U Zdešar
- Institute of Occupational Safety, Ljubljana, Slovenia
| | - K Zaletel
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia; Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - P Tomše
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia
| | - L Ležaič
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia; Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
3
|
de Jong MC, Jamal K, Morley S, Beale T, Chung T, Jawad S, Hurel S, Simpson H, Srirangalingam U, Baldeweg SE, Rozalén García V, Otero S, Shawky M, Abdel-Aziz TE, Kurzawinski TR. The use of computed tomography as a first-line imaging modality in patients with primary hyperparathyroidism. Hormones (Athens) 2021; 20:499-506. [PMID: 32405929 DOI: 10.1007/s42000-020-00205-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Accepted: 04/26/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND The success of minimally invasive parathyroidectomy (MIP) relies on accurate localization of the abnormal parathyroid glands. Concordant findings on ultrasound (US) and 99mTc-scintigraphy (sestamibi) are currently considered the 'gold standard'. Computed tomography (CT) has also recently been used in preoperative planning. We sought to assess the accuracy of CT for localization of abnormal parathyroid glands in such patients. METHODS An audit of 75 patients with primary hyperparathyroidism (PHPT) who underwent neck US and CT between 2017 and 2019 at our center as their first-line imaging. RESULTS All 75 patients underwent US and CT and 54 (72.0%) also had sestamibi. CT alone identified a potential target in all patients, of which the location was correct in 63 (84.0%). The overall combined sensitivity of US and CT was 88% (95% CI 78-94) and was higher than the combined sensitivity of US and sestamibi (65% [95% CI 53-76]; p < 0.001). Twenty-one patients (28.0%) had an ectopic gland, and the sensitivity of US and CT was 86% (95% CI 64-96) versus US and sestamibi (57% [95% CI 34-77]; p = 0.016). For adenomas < 1.0 g (n = 36; 48%), the accuracy of CT was 81% (95% CI 64-91) compared with 62% (95% CI 44-77) for US and sestamibi (p = 0.04). The correct preoperative diagnosis of multiglandular disease (n = 9; 12%) seemed to be the most difficult, with similar accuracy for US and sestamibi (40% [95% CI 14-73]) and US and CT (50% [95% CI 20-80]) (p > 0.99). CONCLUSION The combination of US and CT was able to correctly identify the location of the abnormal parathyroid in 88% of patients and, in comparison with US and sestamibi, had better diagnostic accuracy, especially for smaller and ectopic adenomas. This finding suggests that US and CT could be considered as a first-line imaging modality in patients with PHPT considered for MIP.
Collapse
Affiliation(s)
- Mechteld C de Jong
- Centre for Endocrine Surgery, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK.
| | - K Jamal
- Centre for Endocrine Surgery, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - S Morley
- Department of Radiology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - T Beale
- Department of Radiology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - T Chung
- Department of Endocrinology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - S Jawad
- Department of Radiology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - S Hurel
- Department of Endocrinology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - H Simpson
- Department of Endocrinology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - U Srirangalingam
- Department of Endocrinology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - S E Baldeweg
- Department of Endocrinology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - V Rozalén García
- Centre for Endocrine Surgery, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - S Otero
- Department of Radiology, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - M Shawky
- Centre for Endocrine Surgery, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - T E Abdel-Aziz
- Centre for Endocrine Surgery, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| | - T R Kurzawinski
- Centre for Endocrine Surgery, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| |
Collapse
|